Electromagnetic Compatibility Test Report Test results of Floww equipment



Similar documents
TEST REPORT EN (1997) +A1 (2001)

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

Light armature failure investigation report

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

TEST REPORT FROM RFI GLOBAL SERVICES LTD

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

EMC TEST REPORT For. Webcam. Model Number: CAM67U

Test Report #: Date: April 8, 2005

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

EMC Test for Compliance with EU EMC Directive 2004/108/EU

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Waveguide Access Point WGA631. Product Guide

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

RAPPORTO DI PROVA / TEST REPORT

30 In Compliance October

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

Declaration of Conformity.

Electronic Communication Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

Partial GSM TEST - REPORT

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC File reference No:

Design and Certification of ASH Radio Systems for Japan

The effects on trees of pulsed digitally modulated high-frequency electromagnetic fields produced by EM transmitters

EC-Declaration of Conformity Annex

Declaration of Conformity.

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

Declaration of Conformity.

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

Declaration of Conformity.

Declaration of Conformity.

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

RX-AM4SF Receiver. Pin-out. Connections

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

Declaration of Conformity.

Dual Chamber Temporary External Pacemaker

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

Telephone- and leased line modem for industrial applications TD-36

Foxboro Evo Process Automation System

UK Radio Licence Interface Requirement 2036 For Mobile Asset Tracking Services

EMC Expert System for Architecture Design

Rack mounted telephone- and leased line modem for industrial applications

47000 SERIES - ELECTRONIC TRANSFORMERS

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

EMC Standards: Standards of good EMC engineering

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

Regulatory requirements - USA

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

ETSI EN V2.1.1 ( ) Harmonized European Standard (Telecommunications series)

STRATO LED Drivers 70W, Single output

Application Note AN001

A RF18 Remote control receiver MODULE

T200, PTP/IEEE 1588 Grandmaster Clock and

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

Federal Ministry for Transport, Innovation and Technology (Austria)

USB/RS485 converter cable, complete

R&S SMZ Frequency Multiplier Specifications

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

认 证 之 家

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

Dear Customer! Thank you for choosing our product.

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS

EMC for test engineers by. Laplace Instruments Ltd. An introduction to the world of EMC compliance testing for engineers new to the topic.

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

40 Years of experience in EMC testing

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Draft ETSI EN V1.2.1 ( )

ETSI EN V1.1.1 ( )

7.5 Watt AC-DC Switch Power Supply

Correlation between OATS, Fully Anechoic Room and GTEM Radiated Emissions

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

Operating Manual UWAPS-TINY Series

The EMI-Receiver according to CISPR

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

FM TRANSMITTER & RECEIVER HYBRID MODULES. FM-RRFQ SERIES. Transmitter. Receiver. Applications

Transcription:

Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww (Small) pocketfloww (medium) heatingfloww electrofloww aquafloww biofloww (Home) geofloww (Home) biofloww (Office) geofloww (Office) : production series Serial number Date of receipt : 2010 June, 18 Date of test : 2010 June, 18 Date of test report : 2010 July, 15 This publication may be entirely reproduced and/or made public. Separate parts of this publication may not be reproduced and/or published by print, photo print, microfilm or any other means without the previous written consent of D.A.R.E!! Consultancy. All rights and obligations of contracting parties are subject to either the Standard Conditions of D.A.R.E!! Consultancy or the relevant agreement concluded between the contracting parties.

Manufacturer : The Floww Company Peperstraat 17 5211 KM DEN BOSCH Tests carried out on behalf of : The Floww Company Peperstraat 17 5211 KM DEN BOSCH Applicant's representative : Mr. M. Schechtl In the capacity of : Manufacturer Tests carried out by : D.A.R.E!! Consultancy Test engineer : E. Bloem Test engineer Author : A.S. Diks Senior Test engineer Released : D. van der Vlugt Director Reference number: 10C00357RPT01.doc Page 2 of 18

Contents 1 Introduction... 4 2 EUT details... 5 3 Operating conditions during test... 6 3.1 Test considerations... 6 3.2 Mode(s) of operation... 6 3.3 Acceptance criteria... 6 3.4 Test configuration... 6 4 Possible test case verdicts... 6 5 Explanation Status Report... 7 6 Standards and test plan... 7 6.1 Test plan deviations... 7 7 Test results... 8 7.1 Emission tests... 8 7.1.1 Radiated emission... 8 8 Evaluation... 14 9 Conclusion... 16 9.1 Remarks... 16 10 Appendix A: General performance criteria... 17 11 Appendix B: Pictures of EUT... 18 Reference number: 10C00357RPT01.doc Page 3 of 18

1 Introduction D.A.R.E!! Consultancy has been asked by The Floww Company to carry out EMC emission and immunity tests on the Floww equipment. This report is only to be used for this purpose. At the request of The Floww Company, the EMC tests are carried out in order to find out whether the product complies with the emission limits and immunity test levels as described in chapter 6 of this report. The tests are carried out at our facilities located in Woerden,. The test results presented in this report relate only to the product tested. In this report, the product tested will be referred to as Equipment Under Test (EUT). This report is in conformity with ISO 17025. Opinions or interpretations mentioned in this report are excluded from accreditation. All tests as described in the applied standard(s) are carried out, unless otherwise specified in this report. The reported expanded uncertainty of measurement is based on a standard uncertainty of measurement multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%, but excluding the contribution of the EUT. The expanded uncertainty of measurement has been determined in accordance with UKAS publication LAB34. Reference number: 10C00357RPT01.doc Page 4 of 18

2 EUT details The details for the Floww equipment supplied for test were as follows. EUT details Name: Floww equipment Description: The EUT is a complete closed stainless steel tube. In the tube are electrical components placed like coils, resistors and capacitors. The EUT contains also a reservoir with a liquid. In one module is a EPROM place. The electronic and electrical parts are placed in several different size tubes. Brand: Floww Model number: mobilefloww screenfloww pocketfloww (Small) pocketfloww (medium) heatingfloww electrofloww aquafloww biofloww (Home) geofloww (Home) biofloww (Office) geofloww (Office) Serial number: production series Power supply: No power supply Rated Power: -- Dimensions (L*W*H [m]): mobilefloww 10mm screenfloww 110 mm pocketfloww (Small) 70mm(L) pocketfloww (medium) 70mm (L) heatingfloww 108mm electrofloww 165 mm aquafloww 225 mm biofloww (Home) 495mm geofloww (Home) 580mm biofloww (Office) 495mm geofloww (Office) 580mm Software release: -- Hardware release: Production type Environment to be used: Buildings like office and domestic System description (if ): -- Cable connections to EUT and peripheral equipment None Reference number: 10C00357RPT01.doc Page 5 of 18

The condition of the EUT during reception was undamaged and fully functional. 3 Operating conditions during test 3.1 Test considerations The EUT is not a piece of electronics with a measureable output. So no performance can be checked. Therefore are no immunity tests. 3.2 Mode(s) of operation The test mode(s) during testing were defined as: Mode 1: The EUT tries to receive Electro Magnetic Fields and absorbs the energy and converts it to thermo energy Mode 2: -- Mode 3: -- Mode 4: -- 3.3 Acceptance criteria The criteria for recording a malfunction of operating during the immunity tests are shown in the table below. Acceptance criterion Mode 1: Acceptance criterion Mode 2: Acceptance criterion Mode 3: Acceptance criterion Mode 4: Not Not Not Not The applicant's representative was present to witness the testing. 3.4 Test configuration The EUT is tested as Table top equipment. The Appendixes of this report show pictures of the test configuration during the tests. 4 Possible test case verdicts NA or not : test does not apply to the EUT P(ass) : EUT does meet the requirement Reference number: 10C00357RPT01.doc Page 6 of 18

F(ail) : EUT does not meet the requirement U(ndetermined) : Pass or Fail could not be established NR or not requested : test is not requested by customer Pass or fail statements exclude the measurement uncertainty. 5 Explanation Status Report Final : Formally signed report, with a final conclusion. Changes in the report will lead to a new report with a new report number. Preliminary : Intermediate unsigned report, with a temporary conclusion. Changes in the report will lead to a new report with a new report number. 6 Standards and test plan The EUT is assessed against the following requirements: Emission : EN 61000-6-3 (2007) Immunity : EN 61000-6-1 (2007) If available, a test plan is used as a supplement. 6.1 Test plan deviations There was no test plan available. Reference number: 10C00357RPT01.doc Page 7 of 18

7 Test results 7.1 Emission tests According the information of the customer, the class of emission is B. 7.1.1 Radiated emission The radiated emission tests are carried out in a Semi Anechoic Room (SAR). First, pre-tests are carried out in the SAR. Finally, quasi peak tests are carried out at the highest peak values. The test results are recorded with a Spectrum Analyser / Measuring Receiver. The tests are carried out in accordance with the standard EN 61000-6-3 (2007) and the basic standard EN 55022 (2006) + A1 (2007), where the first standard takes precedence. Measurement uncertainty SAR 30 MHz 1000 MHz: + 5.4 db Reference number: 10C00357RPT01.doc Page 8 of 18

Result Radiated Emission SAR 30.000 MHz to 1000.000 MHz Vertical PIN number: Description: 10C00357 7) RE SAR (ID1494) EN 55022 (2006) vert. 30-1000 MHz Pre-scan SA 3m No turn table, Antenna Tower 60 RE EN55022 class B QP at 3m RBW: 120 khz, Vertical Max Peak 55 50 45 40 Emission (dbµv/m) 35 30 25 20 15 10 5 0 30 M 50 M 100 M 200 M 300 M 500 M 1000 M Frequency (Hz) Test environment Mode of operation: Remarks: All products on the table Pre scan Settings RBW: 120 khz VBW: 1000 khz Antenna distance: 3 m Reference number: 10C00357RPT01.doc Page 9 of 18

Result Radiated Emission SAR 30.000 MHz to 1000.000 MHz Vertical PIN number: Description: 10C00357 8) RE SAR (ID1494) EN 55022 (2006) vert. 30-1000 MHz class B SA 3m 60 RE EN55022 class B QP at 3m RBW: 120 khz, Vertical Max Peak 55 50 45 Emission (dbµv/m) 40 35 30 25 1 20 15 2 10 5 0 30 M 50 M 100 M 200 M 300 M 500 M 1000 M Frequency (Hz) Detected Peaks Nr Frequency Peak Angle Height 1 990.393 MHz 37.754 dbµv/m 182 Degree 4 m 2 230.000 MHz 15.015 dbµv/m 181 Degree 3 m Test environment Mode of operation: Remarks: All products on the table Pass Settings RBW: 120 khz VBW: 1000 khz Antenna distance: 3 m Reference number: 10C00357RPT01.doc Page 10 of 18

Result Radiated Emission SAR 30.000 MHz to 1000.000 MHz Horizontal PIN number: Description: 10C00357 9) RE SAR (ID1494) EN 55022 (2006) hor. 30-1000 MHz Pre-scan SA 3m 60 RE EN55022 class B QP at 3m RBW: 120 khz, Horizontal Max Peak 55 50 45 40 Emission (dbµv/m) 35 30 25 20 15 10 5 0 30 M 50 M 100 M 200 M 300 M 500 M 1000 M Frequency (Hz) Test environment Mode of operation: Remarks: All products on the table Pre scan Settings RBW: 120 khz VBW: 1000 khz Antenna distance: 3 m Reference number: 10C00357RPT01.doc Page 11 of 18

Result Radiated Emission SAR 30.000 MHz to 1000.000 MHz Horizontal PIN number: Description: 10C00357 10) RE SAR (ID1494) EN 55022 (2006) hor. 30-1000 MHz class B SA 3m 60 RE EN55022 class B QP at 3m RBW: 120 khz, Horizontal Max Peak 55 50 45 40 1 Emission (dbµv/m) 35 30 25 20 15 2 10 5 0 30 M 50 M 100 M 200 M 300 M 500 M 1000 M Frequency (Hz) Detected Peaks Nr Frequency Peak Angle Height 1 964.036 MHz 37.262 dbµv/m 0 Degree 4 m 2 230.000 MHz 14.985 dbµv/m 179 Degree 3 m Test environment Mode of operation: Remarks: All products on the table Pass Settings RBW: 120 khz VBW: 1000 khz Antenna distance: 3 m Reference number: 10C00357RPT01.doc Page 12 of 18

Equipment List 30 MHz to 1000 MHz Device Type Brand Type ID Antenna EMCO 3142 1168 Cable antenna -> preamp D.A.R.E!! Development Sucoflex 1478 Turn table D.A.R.E!! Development RadiTurn 1367 Spectrum analyzer Rohde & Schwarz ESU 26 Input 2 1465 Antenna tower D.A.R.E!! Instruments RTW1004B 1496 Reference number: 10C00357RPT01.doc Page 13 of 18

8 Evaluation The following table displays the results of the tests, which are carried out to the EUT. Test results summary Test sequence Phenomenon Basic standard EUT Modified during test Result EN 55016-2-1 (2009) & EN 55022 -- Not -- Conducted emission, test with a LISN -- Conducted emission, test with a Voltage Probe (2006) + A1 (2007) EN 55016-2-1 (2009) & EN 55022 (2006) + A1 (2007) -- Not 1 Radiated emission, EN 55016-2-3 (2007) No Pass -- Harmonics EN 61000-3-2 (2006) -- Not -- Flicker EN 61000-3-3 (1995) + A1 (2001) + A2 (2005) -- Not -- ESD EN 61000-4-2 (1995) + A1 (1998) + A2 (2001) -- Not -- Radiated Immunity (limited to 1 GHz) EN 61000-4-3 (2006) + A1 (2008) -- Not -- EFT EN 61000-4-4 (2004) -- Not -- Surge EN 61000-4-5 (2007) -- Not -- Conducted Immunity EN 61000-4-6 (2009) -- Not -- Power Frequency Magnetic Field 1 EN 61000-4-8 (1993) + A1 (2001) -- Not -- Voltage Dips and Interruptions 1 EN 61000-4-11 (1994) + A1 (2001) -- Not 1 Tests are excluded from accreditation. Pass or fail statements exclude the measurement uncertainty. Reference number: 10C00357RPT01.doc Page 14 of 18

Explanation if test is not Phenomenon Comment Conducted emission, mains The EUT is not AC supplied. terminals, continue (LISN) Conducted emission, The EUT doesn't have multi-user telecommunications / network ports such as telecommunications/network ISDN or Ethernet. port (Current Probe) Conducted emission, load EUT doesn t have load or additional terminals. and additional terminals, continue (VP) Radiated emission above 1 The highest frequency of the internal sources of the EUT is less than 108MHz. GHz (FAR) Radiated emission The EUT doesn t have cables connected. (Absorber clamp) Harmonics The EUT is not AC supplied. Flicker The EUT is not AC supplied. ESD No performance check possible Radiated Immunity The EUT does not contain electronic control circuitry. EFT The EUT is not AC supplied. The EUT doesn t have I/O cables longer than 3 m. Surge The EUT is not AC supplied. The EUT doesn t have I/O cables longer than 30 m. Conducted Immunity The EUT doesn t have I/O cables longer than 3 m. The EUT does not contain electronic control circuitry. Power Frequency Magnetic The EUT doesn t contain components which are sensitive to magnetic fields Field Voltage Dips and Voltage Variations (e. g. Hall sensors). The EUT is not AC supplied. Reference number: 10C00357RPT01.doc Page 15 of 18

9 Conclusion The Floww equipment meets the class B emission levels as described in EN 61000-6-3 (2007). Thus the Floww equipment is in compliance with the harmonised standards under the EMC directive 2004/108/EC, as mentioned above. 9.1 Remarks It is the responsibility of the manufacturer to make certain all subsequent products are identical to the measured sample and as such ensure all manufactured Floww equipments are in compliance with the harmonised standards under the EMC directive 2004/108/EC, as mentioned above. Furthermore, in order to fulfill the European CE-legislation it is the responsibility of the manufacturer of the equipment to draw up a declaration of conformity and to have technical file documentation containing information to demonstrate the conformity of the product to the requirements. At the same time every unit brought to the market or put into service has to be marked with the CE-mark. Reference number: 10C00357RPT01.doc Page 16 of 18

10 Appendix A: General performance criteria Performance criterion A: The apparatus shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. Performance criterion B: The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended. Performance criterion C: Temporary loss of function is allowed, provided the loss of function is self-recoverable or can restored by the operation of the controls. Reference number: 10C00357RPT01.doc Page 17 of 18

11 Appendix B: Pictures of EUT Photo 1: Radiated emission 30 1000 MHz Photo 2: radiated emission 30 1000 MHz Reference number: 10C00357RPT01.doc Page 18 of 18