Emerson UltraTech Variable-Speed Motor

Similar documents
, User s Manual

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Digi-Motor Installation Guide

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

ECM. Service Guide.

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Fan Coil EC Motor Control

Gas Oven Repair Guide

HEAT SIPHON ANSWERBOOK

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

ECM SERVICE GUIDE. A Regal Brand Regal-Beloit Corporation

UV100A Ultraviolet Air Treatment System

*.ppt 11/2/ :48 PM 1

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

INSTALLATION & SERVICE MANUAL. Display Panel

ABS/VDC WHEEL SPEED SENSOR DIAGNOSIS

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Pro Logic Version Diagnostics Manual

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Seven function digital multimeter

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Class 5 to 7 Truck and Bus Hydraulic Brake System

PUSH BUTTON START INSTALLATION MANUAL

AutoRanging Digital MultiMeter

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

TROUBLESHOOTING ABS DIAGNOSTIC CODES L20293, Rev. 1/13

National- Spencer Inc.

CARING FOR YOUR WATER HEATER

Medium voltage VCP-W MR2 (integral racking)

Installation, Operation and Maintenance Manual

3 WATT LED SPOTLIGHT Model No. SLM

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

6. Diagnostics for A/C System Malfunction

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

G670 Intermittent Pilot Ignition Controls

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Quickie Rhapsody Service Manual

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Model 1756 Test Lead Kit

Operator: Save these instructions for future use!

SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N &

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Meritor WABCO Pneumatic Antilock Braking System (ABS) 42.22

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

12-Volt 10-Amp Regulated Power Supply

Manual Ranging MultiMeter

Technical Information

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

AIR CONDITIONING SYSTEMS

UPGRADING AND SERVICING GUIDE

TROUBLESHOOTING GUIDE



ABS Flash Code (Blink Code) Instructions

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Introduction. Motor Types

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

POWER TO GET THE JOB DONE

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

15GAL STEEL OIL DRAIN WITH 110V PUMP

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

User Guide. Model Insulation Tester / Megohmmeter

Operating Precautions: User configuration options:

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

=============================== WARNING

AC-DC Converter Application Guidelines

Yoke harness color code: Horizontal: Red & Blue. Vertical: Yellow & Brown, or Yellow & Green, or Violet and Brown.

How To Control A Thermostat

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

601 International Ave. Washington, Missouri (636) (636) (FAX) M REV C

Owner s Manual. ULTRA-POWER II ACCU-POWER & ACCU-POWER ONBOARD Solid State Fully Automatic Chargers. Manual Number Edition Code 0493B0101A

A/C-HEATER SYSTEM - AUTOMATIC

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV


Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

UV100E Ultraviolet System

Integrated Metering Systems, Inc.

GENUINE PARTS INSTALLATION INSTRUCTIONS

E2 Series Electric Furnaces

ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L

MCR1900 Media Converter 19-Slot Chassis

INSTALLATION INSTRUCTIONS

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ECM Blower Motor Replacement Controls Programming Process

Single Phase Soft Starter

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

ENERGY SMART TROUBLESHOOTING GUIDE TABLE OF CONTENTS:

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Square D Clipsal C-Bus Network Analyzer

Transcription:

Generation I Generation II Emerson UltraTech Variable-Speed Motor Troubleshooting Manual 1 HP, ¾ HP, ½ HP, and ⅓ HP

Table of Contents About the Emerson UltraTech Variable-Speed Motor... 2 Safety Tips... 4 Getting Started... 5 Motor isn t Spinning or Runs Abnormally... 5 Motor Rattles or Makes Excessive Noise... 5 Motor and Control Unit Diagnostics... 6 Check I: Diagnosis with Ultracheck-EZ Diagnostic Tool... 7 Check II: Electrical Troubleshooting... 11 Check III: Control Unit Verification... 14 Check IV: Motor Verification... 18 Final Checks... 21 This manual is intended as a guide to identifying and diagnosing problems related to the Emerson UltraTech variable-speed motor. It is not intended to provide instructions concerning diagnosis of related system components nor the service or replacement of the blower motor. This manual provides troubleshooting instructions for both Generation I and Generation II of the UltraTech variable-speed motor. 1

About the Emerson UltraTech Variable-Speed Motor The Emerson UltraTech variable-speed motor is a 4-wire electronically controlled motor developed by Emerson Climate Technologies. Its two-way communication provides automatic configuration and checking of system settings to ensure the customer better comfort, efficiency, and higher reliability. The UltraTech motor provides efficient soft start-and-stop and automatically adjusts its speed to precisely match humidity and temperature needs. The end result for homeowners is enhanced energy efficiency and home comfort. About Emerson Emerson, based in St. Louis, is a global leader in bringing technology and engineering together to provide innovative solutions to customers through its network power, process management, industrial automation, climate technologies, and appliance and tools businesses. For more information, visit Emerson.com. About Emerson Climate Technologies Emerson Climate Technologies, a business of Emerson, is the world s leading provider of heating, ventilation, air conditioning and refrigeration solutions for residential, industrial and commercial applications. The group combines bestin-class technology with proven engineering, design, distribution, educational and monitoring services to provide customized, integrated climate-control solutions for customers worldwide. Emerson Climate Technologies innovative solutions, which include industry-leading brands such as Copeland Scroll compressors and White-Rodgers instruments, improve human comfort, safeguard food and protect the environment. For more information, visit EmersonClimate.com. 2

UltraTech Variable-Speed Motor Assembly Motor Control Generation I Generation II 3

Safety Tips WARNING SHOCK HAZARD! Do not expose the motor or control unit to rain or moisture. DO NOT separate the motor and control unit while the motor is in operation. CAUTION Motor and control unit are assembled and calibrated as a set. Mismatching the motor or control unit with other unsuitable parts will drastically affect performance tolerance. To prevent permanent damage to the unit DO NOT apply 240Vac to the motor with the jumper positions 1 and 2. NOTICE The motor and control unit connectors are keyed to prevent misconnecting. DO NOT force the connectors together. To service the motor, disconnect power cable and wait 30 seconds before handling the power cord. This allows the bus capacitor to fully discharge. 4

Getting Started This troubleshooting guide provides field technicians a step by step process for accurately diagnosing and troubleshooting certain problems experienced by Emerson UltraTech motors. It does not override or replace instructions suggested by the manufacturer of the HVAC system. To prevent misdiagnosis and unneeded repairs, operators should try the steps listed in the Basic Troubleshooting section first. If the problem still exists or does not resolve the ongoing issue, go to the Motor and Control Unit Diagnostic section on page 6. Basic Troubleshooting Motor isn t spinning or runs abnormally. Verify thermostat is issuing call for activity. Check circuit breaker for trips or accidental shutoff. Verify communication cable and power cord are securely connected to control unit connectors. Inspect for shorts, detached wiring, or loose connections. Inspect control unit for broken or loose connectors, moisture, excessive dirt or other damage. Motor rattles or makes excessive noise. Inspect motor and blower for accumulated dirt, internal debris or other signs of damage. Inspect blower fan for bent or missing blades, misaligned shaft, or unsecured mounting to shaft. Inspect motor shaft for damaged bearings. Inspect blower housing for cracks, dents, or corrosion. Inspect blower housing for secure mounting to system chassis. Verify motor shaft spins freely without effort, by hand, in both directions. 5

Motor And Control Unit Diagnostics WARNING Only trained and qualified professionals familiar with UltraTech motors should service the motor and control unit. Before connecting or disconnecting cables or other electrical connections, verify power is shut off to the system. Failure to comply may cause serious damage to the motor, HVAC system or injury to personnel. Because of the risk of electric shock, only individuals thoroughly trained in the use of multimeters should conduct voltage tests. Never touch the metal contacts on the multimeter during a test. Always check testing equipment for proper operation before use. Do not operate the motor without blower wheel attached. Without the blower wheel, the motor will run continuously to a maximum speed and then stop. Voltage symbols vary among different multimeters and may be displayed as: VAC, AC, V, or a V beneath a wavy line. Select the correct symbol and set the multimeter to the voltage closest to the voltage that is being measured. 6

Check I: Diagnosis with Ultracheck-EZ Diagnostic Tool If the Ultracheck-EZ diagnostic tool is not available, please proceed to page 13 and complete Checks II through IV in order. NOTE Only trained and qualified professionals familiar with UltraTech motors should service the motor and control unit. Connecting the Ultracheck - EZ Diagnostic Tool 1. Disconnect or turn off AC power to the furnace, air handler, or equipment being serviced. 2. Disconnect the four wire communication cable from the control unit connector [Figure 1]. Generation I Generation II power communication Figure 1 7

3. Connect the four wire connector of the Ultracheck-EZ diagnostic tool [Figure 2] to the control unit communication connector [Figure 1]. Figure 2 4. Attach one of the alligator clips of the Ultracheck-EZ diagnostic tool [Figure 3] to a proper ground source. Figure 3 5. Attach the other alligator clip [Figure 3] to a proper 24VAC source. NOTE There is no polarity on the alligator clips. The UltraCheck-EZ diagnostic tool is equipped with a nonreplaceable fuse. DO NOT connect the UltraCheck-EZ diagnostic tool to a power supply over 24Vac. Applying more than 24Vac will make the UltraCheck-EZ diagnostic tool inoperable. Green LED Orange Power Button Figure 4 6. Reestablish power to the furnace, air handler or system being serviced. 8

NOTE The orange button on the UltraCheck-EZ diagnostic tool sends a signal to the UltraTech motor to rotate when pressed. There may be a five second delay between the time the button is pushed and the motor begins to rotate. If the orange button doesn t illuminate when pressed, the UltraCheck-EZ diagnostic tool is not connected to a 24Vac supply or is inoperable. The green LED is an indicating signal that the UltraTech motor is communicating with the UltraCheck-EZ diagnostic tool. If the green LED doesn t blink, the control unit should be replaced. 7. Use the scenarios below to determine needed action. Complete steps 8-11 before proceeding to the next check. Press the orange button [Figure 4] on the Ultracheck-EZ diagnostic tool and wait five seconds for the blower to spin. Orange Power Button Green LED Motor Blower Comments Not Lit Not Lit If button does not illuminate when power button diagnostic tool is inoperable. Not is depressed, verify 24Vac is available at alligator Rotating clips. If 24Vac is verified, the UltraCheck-EZ Lit Blinking Rotating Motor and control unit are functioning properly. Lit Not Lit Rotating Control unit should be replaced. Lit Blinking Not Further investigation required. Proceed to Check Rotating IV to verify motor operation. Lit Not Lit Not Rotating Control unit should be replaced, proceed to Check IV to verify the motor is still operational. 8. Press the orange button [Figure 4] again to stop the blower and turn off the Ultracheck-EZ diagnostic tool. 9. Disconnect or turn off AC power to the furnace, air handler, or system being serviced. 9

10. Remove both alligator clips [Figure 3] from the 24Vac and ground connections. 11. Reconnect the four wire communication connector to the control unit connector [Figure 1, page 7]. 12. Reestablish power to the furnace, air handler or system being serviced. 10

Check II: Electrical Troubleshooting 1. Disconnect or turn off power to the furnace, air handler, or system being serviced and wait 5 minutes. This allows the capacitors in the control unit to fully discharge. 2. Check the rotation and speed of the blower fan. Determine if blower fan can spin freely manually, without effort or assisted means. If binding occurs, the motor needs to be replaced. 3. Determine if HVAC system is wired for 120VAC power or 240 VAC power. If system is wired for 120VAC power, verify a jumper wire is installed between positions 1 and 2 of the power cord connector. On systems wired for 240 VAC, the jumper wire should be removed [Figure 5]. CAUTION Operating the motor at 240VAC with jumper wire installed will cause significant damage to the motor. Figure5 11

4. Disconnect power cord from connector on control unit. Inspect power cord for bent, damaged, or recessed wires and terminals [Figure 1, page 7]. Contact HVAC manufacturer if power cord contains bent, damaged, or recessed wires and terminals. 5. Disconnect four wire communication cable from connector on control unit. Inspect cable for bent, damaged, or recessed wires and terminals [Figure 1, page 7]. Contact HVAC manufacturer if communication cable contains bent, damaged, or recessed wires and terminals. 6. Reconnect or turn on power to the furnace, air handler, or system being serviced. 7. Check the voltage between positions 4 and 5 of the power cord connector [Figure 6]. Contact HVAC manufacturer if system is rated for 120VAC power, and the measured voltage between positions 4 and 5 is not 120VAC. Contact HVAC manufacturer if system is rated for 240VAC power, and the measured voltage between positions 4 and 5 is not 240VAC. If the measured voltages are correct between positions 4 and 5 for the 120VAC or 240 VAC system, go to step 8. Figure 6 8. Check the voltage between positions 1 and 4 of the communication cable connector [Figure 5]. Contact HVAC manufacturer if the measured voltage between positions 1 and 4 is not 9-15VDC. If the measured voltage between positions 1 and 4 is 9-15VDC, go to step 9. If all electrical checks are ok, go to step 9. 12

9. Disconnect or turn off AC power to the furnace, air handler, or system being serviced. Wait 5 minutes to allow the capacitors to fully discharge. 10. Proceed to Check III. 13

Check III: Control Unit Verification Generation I 1. Disconnect or turn off AC power to the furnace, air handler, or system being serviced. Wait 5 minutes to allow the capacitors to fully discharge. Removing Control Unit 2. Loosen two screws securing the motor and control unit together. Twist the control unit and pull away from motor until both units are separated [Figure 7a]. Generation II 1. Disconnect or turn off AC power to the furnace, air handler, or system being serviced. Wait 5 minutes to allow the capacitors to fully discharge. Removing Control Unit 2. Remove three screws securing the motor and control unit together. Grasp the control unit and pull away from motor until both units are separated [Figure 7b]. screw screw screw Figure 7a Figure 7b 14

3. Disconnect the four-wire motorto-control harness from the motor end [Figure 8a] and remove control unit [Figure 7a]. Inspect for bent, damaged, or recessed wires and terminals inside of connector. Replace control unit if four-wire harness contains bent, damaged or recessed wires and terminals. 3. Disconnect the three-wire motorto-control harness from the control [Figure 8b] and remove control unit [Figure 7b]. Inspect for bent, damaged, or recessed wires and terminals inside of connector. Replace control unit if the three pin connector contains bent damaged or recessed terminals. 3 Wire Motor-to-Control Harness 3 Pin Connector Figure 8a 4. Inspect the NTC thermistor inside of control unit for any cracks or breakage [Figure 9a]. Replace control unit if NTC thermistor is cracked or broken. Figure 8b 4. Inspect the NTC thermistor inside of control unit for any cracks or breakage [Figure 9b]. Replace control unit if NTC thermistor is cracked or broken. NTC Thermistor Figure 9a 15 Figure 9b

5. Inspect capacitors inside of control unit for bulging or swelling caps [Figure 10a]. Replace control unit if capacitors are bulging or swollen. 5. Inspect capacitors inside of control unit for bulging or swelling caps [Figure 10b]. Replace control unit if capacitors are bulging or swollen. Figure 10a 6. Check phase to phase resistance between each of the three phase wires (red, blue, and yellow) in the harness connector [Figure 11a]. Resistance levels between any two wires should be greater than 100K. Do not check the green wire during this test. If multimeter indicates resistance levels greater than 100K, the control unit is functioning properly. Next, to verify motor functionality, proceed to Check IV. Replace control unit if multimeter indicates resistance levels lower than 100K. Figure 10b 6. Check phase to phase resistance between each of the three phase pins in the harness connector [Figure 11b]. Resistance levels between any two wires should be greater than 100K. If multimeter indicates resistance levels greater than 100K, the control unit is functioning properly. Next, to verify motor functionality, proceed to Check IV. Replace control unit if multimeter indicates resistance levels lower than 100K. 16

3 Pin Harness Connector Figure 11a Figure 11b 17

Check IV: Motor Verification 1 Disconnect or turn off AC power to the furnace, air handler, or system being serviced. Wait 5 minutes to allow the capacitors to fully discharge. 2 Make sure the motor shaft spins freely without effort manually in both directions [Figure 12]. If motor shaft spins freely, go to step 3. Replace motor if the shaft does not spin freely without effort manually. Figure 12 18

Removing Control Unit (if still mounted to the motor) Generation I 3. Loosen two screws securing the motor and control unit together. Twist the control unit and pull away from motor until both units are separated [Figure 13a]. Removing Control Unit (if still mounted to the motor) Generation II 3. Remove three screws securing the motor and control unit together. Grasp the control unit and pull away from motor until both units are separated [Figure 13b]. screw screw screw Figure 13a 4. Disconnect the four-wire motorto-control harness from the motor end [Figure 14a] and remove control unit [Figure 13a]. Inspect for bent, damaged, or recessed wires and terminals inside of connector. Replace control unit if four-wire harness contains bent, damaged or recessed wires and terminals. Figure 13b 4. Disconnect the three-wire motorto-control harness from the control [Figure 14b] and remove control unit [Figure 13b]. Inspect for bent, damaged, or recessed wires and terminals inside of connector. Replace control unit if the three pin connector contains bent damaged or recessed terminals 3 Wire Motor-to-Control Harness 3 Pin Connector Figure 14a 19 Figure 14b

5 Inspect connector on back side of motor for bent, damaged, or recessed wires and terminals [Figure 15]. Replace motor if connector contains bent, damaged, or recessed wires and terminals. 5 Inspect connector on back side of motor for bent, damaged, or recessed wires and terminals [Figure 15]. Replace motor if connector contains bent, damaged, or recessed wires and terminals. Motor Connector Figure 15 6. Check phase to phase resistance between each of the three phase terminals in the motor connector. Do not check the ground terminal during this test [Figure 15]. Resistance levels between any two contacts should be equal. If resistance levels are equal the motor is functioning properly. Replace motor if the resistance levels are not equal. Replace motor is the resistance levels are open circuited or short circuited. If both motor and control unit appear to be functioning cor rectly, reassemble motor and control unit and contact HVAC system manufacturer. Figure 15 6. Check phase to phase resistance between each of the three phase terminals in the motor connector Resistance levels between any two contacts should be equal. If resistance levels are equal the motor is functioning properly. Replace motor if the resistance levels are not equal. Replace motor is the resistance levels are open circuited or short circuited. If both motor and control unit appear to be functioning cor rectly, reassemble motor and control unit and contact HVAC system manufacturer. 20

Final Checks Check mounting and fastening of motor and control unit. Make sure control unit and motor are securely attached together and mounted tightly in HVAC system. Check control unit connectors. Inspect for shorts, detached wiring, or loose connections. Check power cord and communication cable connections. Make sure both are securely connected to control unit connectors. Check blower motor and verify wheel rotation. Make sure it spins freely manually without effort or assisted means in both directions. Check circuit breaker. 21

*RP875* RP875 2008EM-70 (10/09) Emerson, Copeland Scroll, White-Rodgers, UltraTech and UltraCheck-EZ are trademarks of Emerson Electric Co. or one of its af liated companies. @2008 Emerson Climate Technologies, Inc. All rights reserved. Printed in the USA.