SafeEnergy MCC. Safest power distribution system with maximum mechanical design and constructive accidental arc fault protection.

Similar documents
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

MNS is Switchgear System Technical Overview

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Nothing s BetterThan the Original MODAN Power Distribution Systems

Unified requirements for systems with voltages above 1 kv up to 15 kv

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

SIVACON The Versatile Low-Voltage Switchboard

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

The Intelligent AX1 Switchgear for Medium Voltage

Enhancing Personnel Safety with Arc Resistant Equipment

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

UFES Active protection for switchgear

Automation Products. Low Voltage Switchgear MNS System Overview

Low Voltage Switchboards The Best Technical Solution for Your Ship

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D MOOSBURG TEL FAX

SIVACON Low Voltage Switchboard

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Comparative study for cables and busbars

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

The power distribution board that sets new standards

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

TriLine ASSEMBLY System PowerModules

FAQs-Main switchboard design criteria

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

R.C.C.B. s two-pole LEXIC

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Photovoltaic Solar Energy Unit EESFB

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

3K Load-Break Switches The Program for Safety and Performance. sentric

low voltage switchgear

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors

P System Cubicles. Certified for more safety

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Sample - No Commercial Use

Medium voltage arc flash eliminator units VAM 3ED,

Secondary Unit Substations

IEC & 2 standard. The reference for safe and reliable LV switchboards

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Permissible ambient temperature Operation Storage, transport

Infrarot-Bewegungsmelder IP44

Insulation resistance

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

5SV Residual Current Protective Devices

Securing your electrical installations Prisma,

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

ADM1TE 5/30A DIN rail single phase two wire energy meter

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

Safety automation solutions

HERZ-Thermal Actuators

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Catalog. Arc Guard System TM TVOC-2

Choosing for tranquility

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Safe and secure distribution of medium voltage with AX1

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Series 8146/5-V37 and Series 8150/5-V37

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

ST Series POWER SUPPLIES USER INSTRUCTIONS

Electrical and mechanical interface requirements for separable HR, LR and LRM voltage detecting systems

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

The Low-Voltage Switchboard that Sets New Standards

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Plug and Socket Devices CES 63 A Series 8579

MNS Low Voltage Switchgear System Guide

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Low Voltage Switchgear MNS is with MSpeed

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

Electronic overload relay EF19 and EF45

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Ground-Breaking Power Distribution Boards up to 7000 A

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

SENTRON Switching and Protection Devices Air Circuit Breakers

Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150

GE Power Controls. MiniFORM Switchboards

Extend the Life of Existing Switchgear

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

Advantages of Fixed Circuit Breaker Switchgear

The following components are common to most cubicles; this example is an ABB HK cubicle.

Material test chamber with mechanical convection

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

SURGE PROTECTIVE DEVICES

Transcription:

SafeEnergy MCC Safest power distribution system with maximum mechanical design and constructive accidental arc fault protection.

The safest power distribution worldwide! ModuCon is the only low-voltage switchgear system worldwide which has passed accidental arc testing under strict conditions and with an open cable terminal compartment. The control indicators in the neighbours function and equipment installation rooms did not ignite during testing. ModuCon has been designed to the highest customer standards. Our highest priority was the safety aspect. Our customer DuPont, one of the world's largest chemical corporations and a pioneer when it comes to personal and occupational safety, was involved in the innovative development of the modular safety motor control center from the beginning. ModuCon is a type-tested switchgear combination with the highest operating and operator safety. Compared to conventional low-voltage distribution boards, ModuCon offers substantial improvements in regards to the safety of people. This results in high-availability for your permanent productivity. 2 3

First class energy distribution SAFE. ModuCon has exceeded the highest test requirements according to customers and the new standard IEC/DIN 61439-2 and IEC/DIN 60439-1 part 2. In the highest safety version, ModuCon limits the effects of an accidental arc to the compartment in which it originated. This ensures maximum personal protection. By guiding the accidental arc through special pressure release ducts (with automatically closing pressure relief dampers), ModuCon prevents the accidental arc from affecting or jumping over to adjacent functional compartments. ModuCon has a withdrawable unit design equipped with a dual-movable contacting system and a special operating key. This excludes any accidents due to human error while inserting the withdrawable unit into the plant. UPGRADE. TOR - the innovative Thermo Observation via RFID monitors the load condition of power distribution systems caused by heat stress. It facilitates main-tenance measures and is designed to be retrofitted. PART - the new KÖHL arc fault protection system short-circuits the busbar if it is activated by the Multimaster detection and analysis unit. This is achieved by the light sensor technology and shortens the arc life to a few milliseconds. FLEXIBEL. ModuCon offers flexibly equipped functional units and is designed for internal separation up to form 4b. ModuCon can designed completely arc-base free. Thanks to its modular design, ModuCon can be equipped according to individual customer demands. The individual sections are available in degrees of protection IP 31-41 and can be combined in any way required. ModuCon can be extended to the right and left side and individual sections can be replaced without major cost or effort at any time. USER-FRIENDLY. ModuCon convinces through its operator and operating safety. Inspection work and cleaning can be easily carried out.

Safety inside ModuCon systems are produced in optimized production processes and run through precise quality control - performed by our own experts and external testers. Production of the patented ModuCon system also fulfils certification according to DIN EN ISO 9001:2008. The ModuCon system is based on 20 years of active experience in the production of motor control centers and power distribution systems along with a strong customer service culture. Motivated engineering teams design customised systems to meet requirements set by customers. Thanks to the modular structure of the ModuCon, there are no limits to what can be achieved. Our KÖHL service includes, of course, the complete project management: From advice, development, project planning and documentation to production with functional testing through to construction site supervision, connection on site (SCC**), start-up and after sales services. Use of ModuCon has been successfully tried and tested by our customers, such as, ExxonMobil, JT International Boehringer Ingelheim, Bitburger Brauerei, Arcelor, Dillinger Hütte and RWE. Join them and start your future with the safest power distribution. 4 5

Power cabinet > Safe equipment installation room > Power circuit breaker additionally shield > Cable terminal compartment with blazing filter > Cable terminal compartment SAFETY High personal protection directly in front of the plant and during operations in the cable terminal compartment TESTING Tests (heating, short-circuit, accidental arc ) performed by independent accredited institutes (IPH-Berlin, AIT-Wien and I2PS-Bonn) have been successfully completed and passed even with substantially increased test requirements. FUNCTIONAL COMPARTMENTS With the internal separations to up form 4b and with further compartmentalisation mechanisms in the highest possible safety version, the accidental arc is limited to the compartment in which it originates if a fault occurs.

Withdrawable cabinet > Pressure relief dampers > Shutter made out of strong fiber glass > Earthing withdrawable unit rated current Icw: 35kA/1s bzw. 50kA/150ms > Busbar with special W-profile AVAILABILITY Fast emergency operation thanks to a modular system and an insertion of the arc-tested bridge Shutdown of the outgoing load feeders of a section (in the event of a fault or modification measures) by fast dismantling of the multiterminal busbar connection. Personal protection continues to exist in this case. Modular design of the withdrawable sections means different withdrawable part sizes can be implemented. Thanks to the favourable constructive and design position of the busbar at the top, switchgear extensions can be quickly added to the left or right. The main busbar - package remains as an independent functional unit. > Terminal cable compartment. Control plug cover screwed from metal. Coverage for free matal slots 6 7

Fuse block cabinet FUSE BLOCK SECTION Defined assembly specification through unalterable forced ventilation louvred plate adapter MECHANICAL SYSTEM High stability in the mechanical components Door hinges, withdrawable part fasteners as well as CNC milled components made from specially selected metals Grease-free mechanical function COMPONENTS Component selection independent from manufacturer Different switchgear manufacturers' are used during tests Type verifications are availbale in different component configurations MAINTENANCE Low-maintenance system (recommended maintenance cycles according to BGV A3 DA 5 Abs. 1 Nr. 2) Visual inspections performed on main busbars, also possible with wall installations since busbars are located at the top of the plant

Withdrawable parts WITHDRAWABLE PARTS (identical in construction to ModuPro and interchangeable in both systems) User-friendly and smooth to handle Degree of protection maintained even during tests and in disconnected position Solid latch locking with two handles Mechanical coding options Control and main contacts can be moved separately or jointly 8 9

UPGRADE YOUR SAFETY: with the new safety systems designed by the specialist for arc fault protection! The innovative Thermo Observation via RFID monitors and supervises the load condition of the plant caused by heat stress. Furthermore, it facilitates maintenance measures, is designed to be retrofitted and essentially represents the most advanced solution for energy efficiency. TOR has been successfully developed in cooperation with the Institute Fraunhofer IPMS. Designed as a TAG and equipped with an integrated high-performance chip as well as an appropriate reader and DiPol antenna/aerial TOR sends accurate information regarding thermal energy and potential error sources occurring within the plant to the operator. This information can then be conveniently retrieved with the help of the KÖHL App by using a cell phone, for example. TOR was created in successful cooperation with: The new arc protection system PART short-circuits the busbar of a low-voltage distribution board if activated by the Multimaster detection and analysis unit. This is achieved by means of light sensor technology when the arc flash is created. Paired with the rapid current increase in the shortcircuit case, the two parameters are rounded off and signalled to the short-circuiters. The ARCON arc fault extinction system or the DEHNshort K short circuiter especially developed by KÖHL shorten the arc life to a few milliseconds and as a result increase personal and plant protection.

An overview of the technology GENERAL Standards and requirements IEC/DIN EN 60439-1:1999+A1:2004 IEC/DIN EN 60439-1:1997, Supplement 2 IEC/DIN EN 60439-1:2009, Supplement 2 IEC/DIN EN 61439-1:2009 IEC/DIN EN 61439-2:2009 Rated operational voltage U e 690 V AC Rated insulation voltage U i 1000 V Rated surge voltage resistance U imp 8 kv Degree of contamination 3 Overvoltage category III Protection type (in acc. w. IEC/EN 60529) IP 31/41 Internal subdivision up to 4b FAULT ARC TEST Test voltage Unaffected short circuit Configured test duration U p 725 V AC I cp 65 ka t i 300 ms MAIN BUS BAR Max. rated operating current main bus bar Max. rated continuous current at 35 C with 24h median Rated short-term current resistance main bus bar Rated surge voltage resistance main bus bar Rated frequency I e 2500 A I u 2500 A I cw 80 ka/1s I pk 176 ka 50 Hz DISTRIBUTION BAR INSERT FIELD Rated continuous current at 35 C with 24h median Rated short-term current resistance Rated frequency I u 1500 A I cw 80 ka/1s 50 Hz DISTRIBUTOR BAR FUSE TERMINAL FIELD Rated continuous current at 35 C with 24h median Rated short-term current resistance Rated frequency I u 1700 A I cw 80 ka/1s 50 Hz 10 11

INFO CONTACT KÖHL Group 17, Am Scheerleck 6868 Wecker Luxembourg Tel.: +352 71 99 71-5000 Fax: +352 71 99 71-5009 sales@koehl.eu www.koehl.eu Additional information 4-2013-MODUCON-600-GB