Exterior 410, Balanced White 6500K Standard (Without Diffuser) (19 ) Photometric Report Martin R&D Optics Laboratory, 19-Jan-2011 Data sheet conforms to American National Standard E1.9-2001 Product Exterior 410. Balanced white 6500K. Catalog number 90545003 Lens Option Standard Spread N/A IES file Exterior410_Standard_20110119-1341.ies Procedure Test lamp Model Rated life The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type C photometry in 15 increments in the horizontal plane (rotational) and 3 increments in the vertical plane (radial). CREE XLamp MC-E LEDs 50000 hours Test conditions Ambient temperature 25 ± 5 ºC Consumed power 136 W AC supply 230 V/50Hz Lamp age 100 hours Ballast Type Electronic Ballast factor 1.000 Output Total One-tenth peak Half-peak Efficacy 5600 lumens 4800 lumens 2800 lumens 41.1 lumens per watt Illuminance Cutoff angle 53 One-tenth-peak angle 38 Half-peak angle 19 Cutoff diameter 0.997 x distance One-tenth-peak diam. 0.689 x distance Half-peak diam. 0.335 x distance Intended throw Luminous intensity Luminaire type 2-20 meters 41000 candela Far field
100%=410 lux at 10m (distance from origin)=(throw distance) X (throw distance multiplier)
Exterior 410, Balanced White 6500K Standard (Narrow Diffuser) (22 ) Photometric Report Martin R&D Optics Laboratory, 13-Jan-2011 Data sheet conforms to American National Standard E1.9-2001 Product Exterior 410 Catalog number 90545003 Lens Option Standard Spread N/A IES file Exterior410_Standard_20110113-1347.ies Procedure Test lamp Model Rated life The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type C photometry in 15 increments in the horizontal plane (rotational) and 3 increments in the vertical plane (radial). CREE XLamp MC-E LEDs 50000 hours Test conditions Ambient temperature 25 ± 5 ºC Consumed power 136 W AC supply 230 V/50Hz Lamp age 4 hours Ballast Type Electronic Ballast factor 1.000 Output Total One-tenth peak Half-peak Efficacy 5200 lumens 4500 lumens 2200 lumens 37.9 lumens per watt Illuminance Cutoff angle 61 One-tenth-peak angle 45 Half-peak angle 22 Cutoff diameter 1.178 x distance One-tenth-peak diam. 0.828 x distance Half-peak diam. 0.389 x distance Intended throw Luminous intensity Luminaire type 2-20 meters 27000 candela Far field
100%=270 lux at 10m (distance from origin)=(throw distance) X (throw distance multiplier)
Exterior 410, Balanced White 6500K Standard (Medium Diffuser) (36 ) Photometric Report Martin R&D Optics Laboratory, 28-Jan-2011 Data sheet conforms to American National Standard E1.9-2001 Product Exterior 410 Catalog number 90545003 Lens Option Standard Spread N/A IES file Exterior410_Standard_20110128-1432.ies Procedure Test lamp Model Rated life The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type C photometry in 45 increments in the horizontal plane (rotational) and 3 increments in the vertical plane (radial). CREE XLamp MC-E LEDs 50000 hours Test conditions Ambient temperature 25 ± 5 ºC Consumed power 136 W AC supply 230 V/50Hz Lamp age 100 hours Ballast Type Electronic Ballast factor 1.000 Output Total One-tenth peak Half-peak Efficacy 4900 lumens 4400 lumens 2300 lumens 36 lumens per watt Illuminance Cutoff angle 94 One-tenth-peak angle 70 Half-peak angle 36 Cutoff diameter 2.145 x distance One-tenth-peak diam. 1.400 x distance Half-peak diam. 0.650 x distance Intended throw Luminous intensity Luminaire type 2-20 meters 11000 candela Far field
100%=110 lux at 10m (distance from origin)=(throw distance) X (throw distance multiplier)
Exterior 410, Balanced White 6500K Standard (Wide Diffuser) (65 ) Photometric Report Martin R&D Optics Laboratory, 31-Jan-2011 Data sheet conforms to American National Standard E1.9-2001 Product Exterior 410 Catalog number 90545003 Lens Option Standard Spread N/A IES file Exterior410_Standard_20110131-0859.ies Procedure Test lamp Model Rated life The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type C photometry in 15 increments in the horizontal plane (rotational) and 3 increments in the vertical plane (radial). CREE XLamp MC-E LEDs 50000 hours Test conditions Ambient temperature 25 ± 5 ºC Consumed power 136 W AC supply 230 V/50Hz Lamp age 100 hours Ballast Type Electronic Ballast factor 1.000 Output Total One-tenth peak Half-peak Efficacy 5100 lumens 4800 lumens 2800 lumens 37.6 lumens per watt Illuminance Cutoff angle 138 One-tenth-peak angle 116 Half-peak angle 65 Cutoff diameter 5.210 x distance One-tenth-peak diam. 3.201 x distance Half-peak diam. 1.274 x distance Intended throw Luminous intensity Luminaire type 2-20 meters 4000 candela Far field
100%=40 lux at 10m (distance from origin)=(throw distance) X (throw distance multiplier)