Tungsten Filament Emissivity Behavior

Similar documents
Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Apples & Pears, a CELMA guiding paper: Why standardisation of performance criteria for LED luminaires is important

THE NATURE OF LIGHT AND COLOR

Experiment #3, Ohm s Law

Color Accurate Digital Photography of Artworks

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Examples of Data Representation using Tables, Graphs and Charts

The Electrical Properties of Materials: Resistivity

WHITE PAPER. Source Modeling for Illumination Design. Zemax A Radiant Zemax Company

Halogen Lamps. Lamp Construction

7. What is the current in a circuit if 15 coulombs of electric charge move past a given point in 3 seconds? (1) 5 A (3) 18 A (2) 12 A (4) 45 A

Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light

Solutions to Bulb questions

LIGHTING and LIGHTING SYSTEMS

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

Principle of Thermal Imaging

E/M Experiment: Electrons in a Magnetic Field.

Infrared Thermometry. Introduction, History, and Applications. Optical Pyrometry. Jason Mershon, Advanced Energy Industries, Inc

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Project 2B Building a Solar Cell (2): Solar Cell Performance

Illuminating Light Bulbs

Blackbody Radiation References INTRODUCTION

Physical Quantities and Units

Welcome to this presentation on Thermal Characteristics of LEDs, part of OSRAM Opto Semiconductors LED Fundamentals series.

Interested in conducting your own webinar?

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

Using Photometric Data to Derive an HR Diagram for a Star Cluster

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

LED Retro Fit the next generation in energy efficiency. Converting existing 12v systems to LED

ARTIFICIAL LIGHTING lecture notes

Characterizing Digital Cameras with the Photon Transfer Curve

Light Analysis in lighting technology

Take away concepts. What is Energy? Solar Energy. EM Radiation. Properties of waves. Solar Radiation Emission and Absorption

DSM155 Digital LED Light Meter User s Manual DSM155

Radiation Transfer in Environmental Science

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.

Resistance, Ohm s Law, and the Temperature of a Light Bulb Filament

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Better Vision with LED lights

Calculation of Liquefied Natural Gas (LNG) Burning Rates

Experiment #5: Qualitative Absorption Spectroscopy

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Solar Power Analysis Based On Light Intensity

What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)

Lab E1: Introduction to Circuits

Three Key Paper Properties

1 Laboratory #5: Grating Spectrometer

THERMAL RADIATION (THERM)

Forms of Energy: Multiple Transformations : Teacher Notes

Temperature Scales. The metric system that we are now using includes a unit that is specific for the representation of measured temperatures.

CALIBRATION OF A THERMISTOR THERMOMETER (version = fall 2001)

6/2016 E&M forces-1/8 ELECTRIC AND MAGNETIC FORCES. PURPOSE: To study the deflection of a beam of electrons by electric and magnetic fields.

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

AP1 Electricity. 1. A student wearing shoes stands on a tile floor. The students shoes do not fall into the tile floor due to

Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs

T5 LongLast. GE Lighting DATA SHEET

Lab 3 - DC Circuits and Ohm s Law

Vaporization of Liquid Nitrogen

Discontinued. LUXEON V Portable. power light source. Introduction

Building your own Spectroscope

measurements at varying irradiance spectrum, intensity and module temperature

Spectra of Lights: An Interactive Demonstration with Diffraction Gratings

2 Absorbing Solar Energy

RMS Power. The Meaning of Average

Flicker happens. But does it have to?

Calibration of a High Dynamic Range, Low Light Level Visible Source

HOW ACCURATE ARE THOSE THERMOCOUPLES?

EXPERIMENT 7 OHM S LAW, RESISTORS IN SERIES AND PARALLEL

CHM-27 COB Arrays White LED

HLMP-1600, HLMP-1601, HLMP-1620, HLMP-1621 HLMP-1640, HLMP-1641, HLMP-3600, HLMP-3601 HLMP-3650, HLMP-3651, HLMP-3680, HLMP-3681

Chapter 1 An Introduction to Chemistry

Using the Spectrophotometer

Frequently Asked Questions About OHP Lamps

Agilent T-1 3 / 4 (5 mm), T-1 (3 mm), 5 Volt, 12 Volt, Integrated Resistor LED Lamps Data Sheet

The Atmosphere. Introduction Greenhouse Effect/Climate Change/Global Warming

Analytical Test Method Validation Report Template

Blackbody radiation derivation of Planck s radiation low

Curing Lights HALOGEN CURING LIGHTS 5.2 L.E.D. CURING LIGHTS 5.3 LIGHT GUIDES 5.5 RADIOMETERS 5.6 ACCESSORIES FOR CURING LIGHTS 5.

LED Luminaires. White paper. Evaluating performance of. LED based. luminaires

Solid State Lighting Definitions for Functional and Decorative Applications

Physical Properties of a Pure Substance, Water

Ambient Light Sensor DIP 5mm T-1 3/4 EAALST05RDMA0

The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

3.0mm (1.2") 8 8 Hyper Red Dot Matrix LED Displays Technical Data Sheet. Model No.: KWM-30881XVB

3.0*3.0mm (1.2") 8 8 Super Yellow Dot Matrix LED Displays Technical Data Sheet. Model No.: KWM-R30881XUYB

Asteroid Compositions: Spectra S. K. Croft

LED Lighting - Error Consideration for Illuminance Measurement

Map Patterns and Finding the Strike and Dip from a Mapped Outcrop of a Planar Surface

Electromagnetic Radiation (EMR) and Remote Sensing

University of California at Santa Cruz Electrical Engineering Department EE-145L: Properties of Materials Laboratory

Luckylight. 3.0mm (1.2") 8 8 Super Yellow Dot Matrix LED Displays Technical Data Sheet. Model No.: KWM-30881XUYB

Melting Point, Boiling Point, and Index of Refraction

EVERLIGHT ELECTRONICS CO.,LTD. Technical Data Sheet High Power LED 1W (Preliminary)

Objectives 200 CHAPTER 4 RESISTANCE

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

Transcription:

Tungsten Filament Emissivity Behavior The emissivity of tungsten wire filaments in incandescent lamps is widely known to change with wavelength. It is not so widely known that lamps initially exhibiting this behavior can change to greybody behavior during their lifetime. This complicates both predicting lamp behavior and measuring filament temperature. Tungsten wire is arguably the key component of the incandescent lamp business. The emissivity of tungsten wire is therefore important in several ways. First of all, the higher the emissivity of the filament, the better the lamp performs: there is a direct correlation between emissivity and illumination. Second, the life of the filament depends strongly on the burning temperature. The emissivity is key in measuring the filament temperature, since pyrometry is the only practical non-destructive means to make this measurement. Unfortunately, the emissivity of tungsten is problematic, as can be seen in Figure 1. Figure 1. Emissivity of tungsten from Thermophysical Properties of Matter, Vol. 7 Thermal Radiative Properties, IFI/Plenum, New York, 1970 Each numbered curve refers to a series of measurements that may vary from the others by any or all of the following parameters: sample, temperature, surface preparation, atmosphere, and purity. These measurements show that the emissivity of tungsten metal has quite a range. Additionally, it is seen to change with wavelength. The behavior for a particular sample would be difficult to predict from this graph. The problem grows

worse if temperature measurement is the issue, since the emissivity displays temperature dependence. Temperature dependence of tungsten in the spectral region important to pyrometry is shown in Figure 2. These data are taken from the CRC Handbook of Chemistry and Physics, and are unattributed. Emissivity 0.48 0.46 0.44 0.42 0.4 2000K 2200K 2400K 2600K 2800K 0.38 0.36 500 600 700 800 900 1000 1100 Wavelength Figure 2. Data taken from CRC Handbook of Chemistry and Physics, 60 th Ed., pp. E-381 The uncertainty in the emissivity of tungsten has already been established. Consider now the practice of the lamp industry of coiling, and sometimes re-coiling, the filament to enhance the illumination properties of the lamp by making the resultant assembly operate at a higher temperature than it otherwise would. Another positive effect is to make many small quasi-blackbody cavities so the lamp is more efficient; i.e., so that its emissivity is higher. This adds one more variable to those already ensuring the emissivity of the tungsten filament is impossible to predict. Fortunately, while it may be impossible to predict the emissivity of a tungsten filament, it is in fact possible to measure it. More precisely, the FAR SpectroPyrometer, an expertsystem multi-wavelength pyrometer, has routinely been successful in measuring the temperature of the filament regardless of the behavior of the emissivity. Once the temperature is known, the emissivity may be calculated as a function of wavelength from the temperature and the retained thermal spectrum. Figure 3 shows the result of such a calculation of emissivity taken from data collected on a new 100 Watt, 12 Volt coiled filament (C6) projection lamp that shall here be designated Type A. Color temperature of these lamps is specified to be 3350 Kelvins, and their lifetime 500 hours. The FAR emissivity result was normalized to the 2600 K CRC tungsten emissivity data of Figure 2 at 750 nm. This was done because the filament of the Type A lamp did not fill the instrument s field of view. (Failure to fill the field of view results in the 2

SpectroPyrometer reporting a uniform fraction of the emissivity; it does not affect the measured temperature.) As can be seen, the agreement between the slopes of emissivity vs. wavelength is quite good; the emissivity decreases about 17% over the spectral range. 0.500 0.475 CRC W Emissivity @ 2600K Measured by FAR at 2668K Emissivity 0.450 0.425 0.400 0.375 0.350 500 550 600 650 700 750 800 850 900 950 Wavelength Figure 3. Emissivity as measured by a FAR SpectroPyrometer on a new Type A tungsten halogen projection lamp graphed on the same axes with one of the traces of Figure 2. FAR data normalized to CRC data at 750 nm. However, this does not mean that the emissivity of a tungsten filament will always exhibit both this spectral dependence and agreement with published data. In fact, a Type A lamp was again measured with a FAR SpectroPyrometer after years of intermittent service. The emissivity was found to be uniform to better than 1.5% across the spectrum, exhibiting graybody behavior. These data are plotted in Figure 4. 3

0.500 0.475 Emissivity 0.450 0.425 0.400 0.375 0.350 550 600 650 700 750 800 850 900 950 1000 Wavelength, nanometers Figure 4. This Type A lamp had years of service; contrast this spectral emissivity plot with that of Figure 3. Interestingly, the lamp characteristic curves of temperature as a function of current, Figure 5, remained quite similar, even though the emissivity was very different. 3100 2900 Temperature, deg C 2700 2500 2300 2100 1900 emissivity w ith spectral dependence emissivity flat w ith w avelength, 'gray' 1700 1500 3.50 4.50 5.50 6.50 7.50 8.50 Current, Amperes Figure 5. Temperature vs. current for Type A projection lamps. The one exhibiting spectral dependence was relatively new; the other lamp which exhibited greybody behavior had been in intermittent service for several years. This can be explained by noting that the electrical characteristics are determined by the bulk of the material, specifically the cross-sectional area and length of the wire, while the emissivity is a surface phenomenon. 4

If we extrapolate the data of Figure 5 to the design current, 8.33 Amperes, we find the temperature is approximately 3250 Kelvins. The color temperature for this lamp, 3350 Kelvins, converts to an actual temperature of 3236 K. Clearly 3250 K determined above is in excellent agreement with the 3236 Kelvins specified. There is no obvious visual difference between the new and used filaments that would give an indication of which emissivity behavior to expect. The filaments are shown below in Figure 6 and Figure 7. Figure 6. New lamp of Type A. Grid is ¼ inch square. Figure 7. Lamp of Type A after years of intermittent service. Greybody behavior has been observed in some coiled filament lamps as received. There does not seem to be a way to predict the emissivity behavior before measurement, except that it appears to be consistent within a particular lamp type. The filaments of the lamps that exhibited spectral dependence of emissivity were not very different visibly (other than length) from those that were gray. The filament of a lamp whose emissivity was measured to be gray as received, here designated Type B, is shown below in Figure 8. This filament is also specified as C6. Figure 8. Filament of Type B lamp on a ¼ inch grid. These have been seen to behave as graybodies on first use. 5

Summary Because it governs the amount and color of the light given off, the emissivity of the tungsten filament is the most important parameter in a lamp. We ve seen that it is difficult to predict the emissivity s value, and that filaments of the same specifications can have very different emissivity behavior. Some exhibit emissivity changing with wavelength, while others are gray. Some change behavior during their lifetime. This uncertainty makes the illumination behavior of the lamp hard to predict, and the burning temperature unknown to conventional pyrometry. Fortunately, the FAR SpectroPyrometer has been successful in measuring both the true temperature and the spectral emissivity of the filament no matter which behavior is manifested. 2006 FAR Associates. All rights reserved 6