Air Bari User Manual

Similar documents
Operation Manual FOR & 14030

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Record Cleaning Machine

Dual Cushion User Manual. Specialist Suppliers to the Healthcare Industry

Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Meaco 30L and Meaco 40L dehumidifier instruction manual

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

- 2 - IMPORTANT SAFETY REMINDERS

Portable Air Conditioner

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

4.3-inch Back-Up Camera

Anti-decubitus Mattress 418E 516E - 820Z User's manual

FT-100 Fire Training Fog Machine User Manual English

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Drayton Digistat +2RF/+3RF

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Replacing the vacuum tube

IMPORTANT SAFETY RULES TO FOLLOW

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

San josé OWNER S MANUAL

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

DENTAL CHAIR AND UNIT SP- CIELA IMPORTANT

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Model 43AP Pneumatic Controller, Style B

Bubble King. User Manual

Operations Manual Blast Chiller

SunMaxx Solar Filling Station Operating Instructions

BUNK BED. Model No.: DA3797E - Espresso DA3797P- Pine. UPC CODE: (Espresso) (Pine) NOTE: Lot number: Date of purchase:

OPL BASIC. Dosing System for Professional Laundry machines. Contents

User s Manual Before using the inverter, you need to read and save the safety instructions.

How To Use A Power Supply On A Powerline 2.2 (Ai)

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

Product and functional description

Operating instructions. SCORP 220 Plus SCORP 360. Pipe Cutter. Code Machine-no.:

AerAtron. Ceiling fans

ATS Overhead Table Shelf System INSTRUCTION MANUAL

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

19 LED Tube Controller ORDERCODE 41003

Manual. Solar Fountain Mobile Phone Charger

AerAtron. Ceiling fans

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

Manual Ranging MultiMeter

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Luna/200. Luna/275. Ceiling hoist. User instruction. Important - warning. This manual must be read before the Luna is used

National- Spencer Inc.

LED MOTION ACTIVATED FLOOD LIGHT

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

BeoLab 7-1 BeoLab 7-2. Guide

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

USER S MANUAL HSC-24A

SMD Rework Station TABLE OF CONTENTS

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

AutoRanging Digital MultiMeter

INSTALLATION INSTRUCTIONS

DMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd Dream Swing - 1 -

TIG INVERTER INSTRUCTION MANUAL

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Tablet 30W Tablet 92W

24 Wide Screen LED Monitor with HDMI

Stove Guard Kit User Manual

FG MOISTURE MONITOR Installation & Operation Manual

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Chelsea Loft Bed WARNING:

Original Assembly Guide

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

HP SATA/SAS hard drive and Solid State Drive installation

HERZ-Thermal Actuators

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

LUCCI AIRFUSION QUEST II CEILING FAN

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

CARING FOR YOUR WATER HEATER

2-SLICE COOL TOUCH TOASTER

15GAL STEEL OIL DRAIN WITH 110V PUMP

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Dehumidifier Users manual. For Models: DH45S DH65S

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

2KW CERAMIC HEATER DHCER20. User Manual

HYLA NST Cleaning System

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Transcription:

Air Bari User Manual Alternating pressure mattress for prophylaxis and treatment of pressure sores Indications for use The Air Bari has been developed as a "state of the art" pressure relieving system for Very high-risk patients and for prevention and management of all grades of pressure sores. Contra indications As with all alternating mattress systems, the Air Bari is contra indicated for use where patients have unstable fractures or spinal injuries. CONTENTS 1. HOW THE PRODUCT WORKS... 2 2. INSTALLATION... 2 3. START UP... 4 4. MAINTENANCE PROCEDURES... 7 5. TECHNICAL DATA... 8 6. SUPPLIER ADDRESS... 9 ISSUE 1 PAGE 1 OF 9

1. How the Product works 1.1. Introduction The objective of the product is to relieve the pressure created under a patient when lying on a bed so that blood flow is maintained and tissue oxygenation achieved. It does this by intermittently removing the pressure from the patient by sequentially deflating the supporting air cells of the mattress. The Power Unit provides the source of energy to achieve this and also the necessary monitoring and control systems for efficient and safe operation. In simple terms the air compressor delivers air to the solenoid valves controlling the flow of air into and out of the mattress air cells. The pressure of the air within the mattress is continuously monitored by the solid-state pressure sensor enabling the inflation pressure to be directly controlled and varied to achieve the desired comfort level. The software based control system operates the solenoid valves to enable air to flow into, or out of, the air cells as required according to the operating mode selected. It also maintains the air pressure within the air cells at the required level and controls the action of the alarm system in the event of mains supply failure or over or under inflation pressures occurring. 2. Installation 2.1. Installation of the Mattress Remove the hospital mattress and make sure that the slatted base frame is free of pointed or sharp objects to avoid damaging the Mattress. Place the Air Bari Mattress on the bed. Ensure that the removable cover is on top and that the umbilical hose is at the foot end of the bed. Fasten the Mattress to the bed frame using the straps on the base of the Mattress. The straps should not be too tight and should not interfere with the operation of the bed. They should be checked regularly. Cover the Mattress with a loose fitting sheet. 2.2. Installation of the Power Unit Hang the Power Unit onto the footboard. The mounting hooks swivel to suit the thickness of the footboard or rail. The hooks also adjust vertically with click-stop locations at 20mm intervals. The Power Unit should be supported until the correct position has been achieved and the black clamping screws firmly tightened (for convenience the clamping screw orientation can be changed by depressing the orange button and freely rotating the clamp screw arms to an optimum position) 2.3. Connecting the Umbilical Connect the Umbilical hose to the Power Unit by inserting the 4 male probes into the female quick-connect valves. The end probe is inserted into the top valve and the other three probes are then aligned with their corresponding valves. The Head Cell/Former supply probe is physically non-interchangeable with the other 3 probes to prevent cross coupling. When they are correctly connected an audible click will be heard. ISSUE 1 PAGE 2 OF 9

2.4. Electrical Supply cable Remove the mains cable from its storage housing in the base of the Power Unit by rotating the two retaining arms so that the cable is no longer restrained and plug into a suitable 230v mains socket. Any surplus cable can be rewound and stored within the Power Unit. 2.5. Switch On Switch on the Power Unit using the mains on/off switch. The message Please Wait Setting Pressure appears on the display and remains until the Mattress is fully inflated. The green Ready LED is illuminated showing that the System is now available for use. ISSUE 1 PAGE 3 OF 9

3. Start Up When the Power Unit is switched on the display shows the message Please wait Adjusting Pressure. The Pressure Sensor monitors the pressure in the Former/Head Cell supply line and when the inflation pressure reaches 50mmHg the system is switched into its operating mode and the green Ready LED is illuminated. 3.1. Dynamic Mode This mode of operation and the Firm comfort setting are automatically selected at the end of the initial inflation phase. The Display message shown is Dynamic Comfort: Firm. 3.2. Static Mode This mode is selected by pressing the Mode switch on the membrane panel. The Display message shown is: Static Comfort: Firm (or other setting selected, see 3.1.5). The Mode is automatically limited to a maximum time of 2 hours, after which, for reasons of clinical safety, the System switches into the Dynamic Mode. 3.3. Comfort Settings The air pressure within the Cells can be varied to provide varying degrees of comfort to suit patient or clinical needs. Three settings; Firm, Medium and Soft are provided equating to nominal inflation pressures of 50,40 and 30mmHg. Pressing the Comfort switch cycles the System through the three settings in turn. The setting selected is displayed on the message panel e.g. Comfort: Medium. If the setting selected equates to a higher pressure than that already in the Cells the System switches into the inflation phase until the pressure selected is reached. If the existing pressure is too high the System switches into the deflation phase until the required pressure reduction is achieved. The Comfort setting is independent of the Dynamic and Static settings 3.4. Maximum Inflation This is a variant of the Static mode in which the Cell pressure is increased to a nominal value of 60mmHg (65mmHg in High Pressure option) in order to provide a rigid, stable surface when physiotherapy and other nursing procedures are being carried out. This mode is limited to a maximum of 20 minutes although it can be extended for a further 20 minutes by pressing the Maximum Inflation switch at any point during this period. The initial display message reads: Max. Pressure 20 min. Remain. The time counts down 20, 19, 18, etc, until at the end of 20 minutes the System automatically ISSUE 1 PAGE 4 OF 9

switches to Dynamic cycling at the previously selected Comfort setting. The Maximum Inflation mode can also be ended, at any time, by pressing the Mode switch. 3.5. Deflation In this mode, selected by pressing the Alarm Cancel and Deflate switches simultaneously, the Cells are emptied of air. The initial display message reads: Deflate 20mins Remain. The time counts down 20, 19, 18, etc, until at the end of 20 minutes the System automatically switches off, the Valves are de-energised and the Compressor ceases to run. The display message changes to: Deflate Complete. 3.6. Head Cell Deflation The Head Cells normally remain constantly inflated (together with the Formers) at the pressure selected Comfort switch. by the Clinically it may be necessary to nurse patients in a prone position i.e. face down. To facilitate this it is desirable to deflate the Head Cells to create a void in front of the patient s face. This is achieved by reversing the settings of the two On/Off taps fitted in the Head Cell tubing circuit. Access is gained via a small zip located at the left hand side of the head end. To deflate the Head Cell first close the on/off tap fitted to the supply tube, which runs along the side of the mattress. This isolates the Head Cells from the Formers. Then open the on/off tap at the free end of the tubing (situated at the end of the mattress). This opens the Head Cells to the atmosphere and the Cells deflate. Note: The Formers must remain inflated at the Comfort setting selected as they now act as the sole reservoir monitored by the System s pressure sensor. If the pressure in the Formers is allowed to fall significantly as a result of opening the on/ff taps in the wrong sequence the Low Pressure Alarm would be activated. To re-inflate the Head Cells, first close the end on/off tap and then open the supply line tap. ISSUE 1 PAGE 5 OF 9

3.7. CPR Deflation The CPR Valve consists of a manually operated rotary action Valve incorporating 4 individual, large bore, spring loaded, dump valves which, when opened, connect all the Cells and Formers to atmosphere achieving rapid Mattress deflation. For convenience and accessibility the Valve is mounted in the umbilical between the Mattress and Power Unit. Turning the red operating knob clockwise to the CPR position activates the Valve. As the Mattress deflates the Low Pressure alarm will be activated and should be cancelled by pressing the Alarm Reset button and switching the Power Unit off. Warning: Close the CPR Valve by rotating the red knob anti-clockwise to the Normal position before switching the Power Unit on again. 3.8. Transportation To change the location of the bed, switch the system to Static and allow all the cells to fully inflate. Switch off the Power Unit using the on/off switch and disconnect the electrical supply cable from the mains socket. The bed can now be moved to a new location where it must immediately be reconnected to the mains electrical supply and the system switched back on. Once the mattress has been refilled, the system will automatically switch into the Dynamic mode at the Firm comfort setting. Other settings may then be selected as required. To move the patient and mattress, e.g. by trolley, switch the system to Static and allow all the cells to fully inflate. Then switch off the Power Unit and disconnect the umbilical hose by depressing the metal actuator buttons on the four quick-connect valves at the side of the Power Unit and withdrawing the probes. The mattress can now be moved independently and will remain inflated for several hours. It should be reconnected with the power unit and mains electrical supply as soon as practicable. Warning: The mattress will not alternate when disconnected from the power unit and/or the mains electrical supply and hence not provide optimal pressure relief. ISSUE 1 PAGE 6 OF 9

4. Maintenance Procedures 4.1. Safety Only qualified electricians trained or formally approved by Rober Ltd. in the operation and maintenance of Rober products may carry out maintenance, modification or repair work on Rober Power Units. Unqualified personnel attempting to work on Rober Power Units risk serious injury to themselves and others, and possibly death by electrocution. 4.2. Cleaning Procedures WARNING: Before cleaning the System make sure that the Power Unit is disconnected from the mains electricity supply. Do not immerse the Power Unit in water or other fluids. Do not autoclave, nor use Phenol for cleaning. Do wash hands before commencing the cleaning process. Don appropriate protective clothing such as gloves, apron and a mask. Ensure all work surfaces are cleaned before and after contact with the mattress. 4.3. Cleaning the Mattress 1. With cover left on the Mattress disconnect the Mattress from the Power Unit. 2. Clean the surface of the wash down table with Hypochlorite solution or equivalent disinfectant. 3. Wash Mattress top using hot water (60 degrees C) containing detergent dry with paper towel. 4. Fold Mattress in half, from head to foot end, clean table and the exposed bottom half of Mattress. Dry with paper towel 5. Invert folded mattress to top half of table, clean table and the exposed half of Mattress. Dry with paper towel. 6. Repeat 3 to 5 using Hypochlorite solution 1,000 parts per million available chlorine. 7. Using suitable brush, hot water, detergent and Hypochlorite solution, clean Umbilical and CPR Valve. Dry with paper towel. 8. If required, the Mattress Cover may be removed and machine-washed at a temperature of 90 degrees C, for not less than 10 minutes. The individual Air Cells can be wiped down with established disinfectants. 9. The Mattress Cover may be sterilised using ETO or Draeger processes. 4.4. Cleaning the Power Unit The Power Unit can be cleaned by wiping with a cloth dampened with a detergent solution, Hypochlorite solution. ISSUE 1 PAGE 7 OF 9

5. Technical Data Air Bari complies with EN 60601-1: 1990 + A1: 1993 5.1. Power Unit Serial Number On rear Label Electrical Supply 230 volt, 50 Hz Power Consumption Max 100 watts Fuses 2 x 1 amp (internal) Compressor Rating 24 litres/minute at 0.01 MPa Protection against shock Class II Class of Equipment Class B Noise Level Approx. 30 db (A) Dimensions 480 x 225 x 130 Weight 6.8 kg Service Interval 12 months 5.2. Mattress Serial Number Internal, at foot end Number of Air Cells 18 Dimensions 1900 x 870 x 250 (Nominal) Weight 8.2 kg ISSUE 1 PAGE 8 OF 9

6. Supplier Address Direct Healthcare Services Limited Unit 8, Withey Court Western Industrial Estate CF83 1BF United Kingdom Tel: 0845 459 9831 Fax: 0845 459 9832 Dyna-Form is a registered trade mark of Direct Healthcare Ltd. Products undergo continuous further development. We therefore reserve the right to change the specifications of the product and the warranty conditions without prior notice. Issue 1, 16/04/10 Manufactured in the UK ISSUE 1 PAGE 9 OF 9