3. Technical Description of Redesign

Similar documents
Android based Alcohol detection system using Bluetooth technology

WAITER: A Wearable Personal Healthcare and Emergency Aid System

Copyright is owned by the Author of the thesis. Permission is given for a copy to be downloaded by an individual for the purpose of research and

Hand Gestures Remote Controlled Robotic Arm

Final Design Report 19 April Project Name: utouch

How To Understand The Performance Of A Smart Rock

Electrocardiogram (ECG) Monitoring System using Bluetooth technology

Undergraduate Research Projects for Engineering Technology Students

Wireless Device for Patient Monitoring

Surveillance System Using Wireless Sensor Networks

Implementation of Knock Based Security System

Wireless Multimedia Technologies for Assisted Living

Sensors & Transducers 2015 by IFSA Publishing, S. L.

Cell Phone Based Liquid Inventory Management Using Wireless System

Logging of RF Power Measurements

ANDROID LEVERED DATA MONITORING ROBOT

Design, implementation and characterization of a radio link in ISM band at 2.4Ghz

Application Note IMU Visualization Software

Design and Implementation of an Accidental Fall Detection System for Elderly

Intelligent Home Automation and Security System

ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE

Design of a Wireless Medical Monitoring System * Chavabathina Lavanya 1 G.Manikumar 2

The SA601: The First System-On-Chip for Guitar Effects By Thomas Irrgang, Analog Devices, Inc. & Roger K. Smith, Source Audio LLC

FEEDBACK ICANE FOR STROKE PATIENT

MEDICAL ALERT SYSTEM FOR REMOTE HEALTH MONITORING USING SENSORS AND CLOUD COMPUTING

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

A LOW-COST WIRELESS HEALTHCARE MONITORING SYSTEM AND COMMUNICATION TO A CLINICAL ALARM STATION

ASL Fingerspelling Translator Glove

oncaring onall tech

GSM Alarm System User Manual

Interfacing with Manufacturing Systems in Education and Small Industry Using Microcontrollers through the World Wide Web

WIRELESS BLACK BOX USING MEMS ACCELEROMETER AND GPS TRACKING FOR ACCIDENTAL MONITORING OF VEHICLES

Wireless Medical Telemetry Laboratory

Decoding an Accelerometer Specification. What Sensor Manufacturer s Don t Tell You! David Lally VP Engineering PCB Piezotronics, Inc.

INFRARED PARTS MANUAL

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

3. Identification of water pumps through RFID technology. 4. Wireless control of remote water pump using RF technology.

US-Key New generation of High performances Ultrasonic device

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

The Study and Design Of a Wireless ECG Monitoring System

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]

Tire pressure monitoring

Sign Language to Speech Translation System Using PIC Microcontroller

AC : DEVELOPING AN INDUSTRY-DRIVEN GRADUATE CERTIFICATE IN TEST ENGINEERING FOR ELECTRICAL ENGINEERING TECHNOLOGISTS

Gage Applied Technologies

Address for Correspondence

Smart Thermostat page 1

Self-Balancing Robot Project Proposal Abstract. Strategy. Physical Construction. Spencer Burdette March 9, 2007

Lab 2 Sensor Modeling Introduction to the Wiimote and the Wiimote LABVIEW Interface

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2012/35

DT3: RF On/Off Remote Control Technology. Rodney Singleton Joe Larsen Luis Garcia Rafael Ocampo Mike Moulton Eric Hatch

MICROCONTROLLER BASED SMART HOME WITH SECURITY USING GSM TECHNOLOGY

DIGITAL-TO-ANALOGUE AND ANALOGUE-TO-DIGITAL CONVERSION

ASSESSMENT OF DERMAL ETHANOL EMISSION SENSORS: EXPERIMENTAL DESIGN

STMicroelectronics is pleased to present the. SENSational. Attend a FREE One-Day Technical Seminar Near YOU!

Wireless Patient Health Monitoring System

detection of any abnormality it immediately sends an SMS to care takers and doctor through GSM it will helps to provide immediate action.

Early Evaluation Center

1. Learn about the 555 timer integrated circuit and applications 2. Apply the 555 timer to build an infrared (IR) transmitter and receiver

Wireless In-Ear Audio Monitor

SECURITY SYSTEM WITH AUTHENTICATION CODE AND ADAPTIVE PHOTO LOG

Original Research Articles

A Study of Speed Control of PMDC Motor Using Auto-tuning of PID Controller through LabVIEW

Various Technics of Liquids and Solids Level Measurements. (Part 3)

REMOTE ELECTROCARDIOGRAM MONITORING BASED ON THE INTERNET

Increase System Efficiency with Condition Monitoring. Embedded Control and Monitoring Summit National Instruments

Recognition of Day Night Activity Using Accelerometer Principals with Aurdino Development Board

Design and Development of a Wireless Remote POC Patient Monitoring System Using Zigbee

SOLUTION BRIEF. Motorola FSA4000. How to Achieve Near 100% Fire Station Alerting Reliability

Project Plan. Project Plan. May Logging DC Wattmeter. Team Member: Advisor : Ailing Mei. Collin Christy. Andrew Kom. Client: Chongli Cai

Patient Health Monitoring Using Wireless Body Area Network

10-3. SYSTEM TESTING AND DOCUMENTATION


Gsm Based Controlled Switching Circuit Between Supply Mains and Captive Power Plant

Fetal monitoring on the move, from a hospital to in-home setting

Ubiquitous Computing Applications: Healthcare & Smart Homes. Emmanuel Agu

Bluetooth Stereo Network

Design and Development of SMS Based Wireless Home Appliance Control and Security System

Report of Research Results

Adding Heart to Your Technology

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

Three Axis TB6560 CNC Driver Users Manual

Automation and Control Engineering Laboratory: Students Perspectives

TRANSMISSION OF ARM BASED REAL TIME ECG FOR MONITORING REMOTELY LOCATED PATIENT

Industry Ap plications

A Review of Security System for Smart Home Applications

Application Note Receiving HF Signals with a USRP Device Ettus Research

GRF-3300 RF Training Kits

Example #1: Controller for Frequency Modulated Spectroscopy

ANDROID BASED PORTABLE ECG MONITOR

Instruction Manual Service Program ULTRA-PROG-IR

POCKET SCOPE 2. The idea 2. Design criteria 3

HOME ALARM MONITORING NETWORK GOH SWEE TIAN

Psychology equipment

Design of Wireless Home automation and security system using PIC Microcontroller

RESEARCH OF IOT CONCEPT IN MONITORING THE ACTIVITIES OF THE ELDERLY PERSON

Social Innovation through Utilization of Big Data

A versatile telemetric system based on mixed Internet and wireless transmission

Artificially Intelligent Home Automation System Based on Arduino as the Master Controller

Transcription:

NEA Final Report Title: Assessment of Autonomous Multi-y Intervention Device to Detect and Manage Nighttime Pruritus among Children with Atopic Dermatitis August 12, 2014 1. Purpose of Study The purpose of this pilot study is to test the effectiveness of a biomedical device called the Portable Autonomous Multi-Sensory Intervention Device (PAMID) to automatically detect the onset of anxiety and scratching in a child with Atopic Dermatitis (AD). This device was also intended to deliver multiy stimuli intended to distract and mitigate the agitation that results in nighttime pruritus, and alert the family caregiver of the child s distress. 2. Project Details In April 2013, this project was granted a 1 year no- cost extension by the NEA in order that a redesign of the device could be completed as well as obtain IRB approval in order to proceed to the recruitment and testing phases of the project. The redesign consisted of a modification of the heart rate and instillation of a that detected scratching movement that was situated in a hand glove (see below technical description and expenditures). As per the human subject guidelines, a new IRB application was submitted to the Oakland University IRB August, 2013 that outlined the modifications that were made to the heart rate as well as the motion in the hand glove. September 5, 2013, the Oakland University IRB informed the investigators that they did not approve our application as it was felt that the investigators did not address all the possible risks to subjects in the study due to the use of the hand glove. The investigators made the required modifications suggested by the IRB to consent forms and other documents and resubmitted the revised application September 17, 2013. Unfortunately, this application was also rejected by the IRB October 2, 2013, requiring minor modifications to the application form, parental consent form and parent observation form. These were made by the investigators October 5, 2013 and resubmitted again for approval. In December 2013 investigators received yet another rejection of the application by the IRB. Many modifications that the IRB were asking for were ones that were corrected in the the September resubmission, and at this time a meeting with the chair of the IRB was requested by the PI to discuss the failure of obtaining IRB approval. It was revealed that because the device was intended for use in pediatric subjects, FDA approval would also be needed. This was estimated to take an additional 6 months, which meant that investigators were unable to recruit subjects for testing and data collection until final approval by both IRB and FDA was granted. The research team met to discuss the feasibility of finishing this project in February 2013 with the knowledge that the extension was only given to April 2013. Due to the prolonged delay in obtaining IRB approval as well as final FDA approval, the team decided that this project could not be completed in the time extended to them by the NEA. 3. Technical Description of Redesign Background Prior to this project, the PIs had been collaborating in development and application of the PAMID device for senior patient monitoring and interference. The device had been tested in a pilot study on dementia patients in a nursing house in Michigan. In this project, PAMID device were modified for monitoring activities and providing possible intervention to children with eczema, particularly in nighttime when itch was more severe and skin damages by involuntary scratching could occur. However, after consulting with pediatric demonologists, it became apparent that the original PAMID, which was

designed to sense heart rate, skin impedance and body temperature, might not be directly used for children s night time monitoring. The original physiological parameters to be detected certainly can reflect the anxiety of the eczema children prior to possible scratching activities. However, the time between the presences, detection of physiological changes and children s damaging scratching actions could be too short for parent s caregiving and scratching stopping. It s necessary to further reduce the time between the detection of children s anxiety, movement and parent s awareness and corresponding preventing actions. Device Design To shorten the awareness and actions lagging behind children s anxiety and scratching, and effectively prevent possible skin damages, the PAMID was greatly modified to accommodate instant scratching detection as an additional function. Other considerations include the method of attachment of the device to a glove worn by the child subject; the reduction of system size due to the wearability of the device. Considering the distance between rooms in a regular house, Bluetooth communication protocol was used in the system. A laptop equipped with Bluetooth receiver and interface software was employed as data hub to manage the data, inform parent for caregiving, and command the intervention unit to soothe the patient. The system diagram of the demonstrated PAMID is shown in Fig. 1. 3-axis motion Sensing unit Data hub Heart rate unit Temperature Local amplifier and ADC Caregiver s alarm device Other intervention devices GSR sweating Microcontroller Receiver Aromatherapy device Wireless transmitter Microcontroller Audio player Intervention unit DAC and driving circuit Blinking LEDs Figure 1. Illustrative system block diagram of the demonstrated PAMID. In the sensing unit, in addition to the heart rate, skin impedance and temperature s, an Analog Device three-axis accelerometer ADXL345BC was added for instant scratching motion detection. In addition to its low working voltage, the accelerometer has a bandwidth of 0.1-2.1 khz, which is suitable for human motion. A micro controller with memory for signal logging, storage and processing was the core of on-board data management. In application, the system was attached to the hand back of a glove worn by the kid with eczema. To avoid any faulty motion detection, the motion was mounted to either index, middle or ring glove fingers at the middle phalanx location. The selection of the glove was under recommendation by pediatric dermatologists. Data of each axis motion collected in 8- hour duration in the night was analyzed and correlations among the three axes were extracted as characteristic motion of scratching. Real scratching motion signal is extracted through a reliable algorithm with signals of 3-axis motion of the patient s fingers as inputs. With the scratching signal detected, the

unit communicates with the command unit and triggers the alarm to parents. Meanwhile, the command unit remotely turns on the intervention unit in which parent s voices or other soothing voices are recorded. The recorded audio will be played to distract, comfort the child with eczema prior to the arrival and caregiving of the parent. Electronics in the intervention unit was packed in a plush doll toy that was selected for the curiosity of the child. Arduino, an open-source electronics platform based on easy-to-use hardware and software, was used for microcontroller programming in data management. PAMID Implementation The modified PAMID was prototyped and preliminary tests were carried out on the developers, as planned in the proposal. No clinical tests were conducted due to the IRB issues we had experienced in the project period. The major functions of the system had been demonstrated on an experimental board before printed circuit board (PCB) design was designed and fabricated by commercial manufacturer. Figure 2 shows the tested PAMID device and fabricated PCB board that processes and transmits the measured motion signals. In the test, the motion is attached to the back of the index finger of a cotton glove; and the PCB board, measured 2 x 4, is wrapped and hidden on palm back of the glove. The PCB was designed at the co-p.i. s research laboratory and was fabricated through a commercial PCB manufacturing service. 3-axis motion Processing and transmitting board Figure 2. A testing PAMID device attached to a small adult glove. Data Collected The functions for heart rate, skin impedance and temperature measurements were verified by quick system checkup. Functions of data communication and alarm emitting of the command unit was tested using heart rate threshold as input signal. Figure 3 shows typical adult responses including heart rate, skin impedance (μs) and body temperature changes during an agitation period. A Labview graphic user interface (GUI) managing and on-screen visualizing system alarm to parents is also shown. System initialization and scratching motion detection has been demonstrated. Fig. 4 shows a measured time domain data set of response in 3 axes when only 1g of acceleration in z-axis was applied to the motion in a period of 30 minutes. This was performed for system initialization purpose. Data in the first three minutes were dropped because of the noise in system initialization. The amplitude in z- axis was much stronger than in the other directions. Responses in other two directions were also tested. The measurements demonstrated good rejections of signals from other two orthogonal directions when

T (ºC) μs Beat/min. 120 110 100 90 80 6 heart beat rate normalized EDR value 4 2 0 36 34 body temperature 32 t (s) (a) (b) Figure 3. Heart rate, skin impedance and body temperature response and Labview GUI for data management and alarm. motion in one direction was measured. Fig. 5 shows a frequency domain response in y-direction. A 3 Hz scratching signal is clearly detection in y-direction, while response in x-axis is flat, indicating the effectiveness of the detection. The detection pattern was also valid in other two directions. Once the scratching pattern was recognized by the algorithm pre-programed in the microcontroller in the unit, the unit will trigger the alarm signal to the parents and energize the intervention unit which is placed close to the subject. At the time the project was terminated, algorithm on scratching pattern recognition was under development. Figure 4. Initial characterization of the accelerometer with 1g of acceleration being applied to z- axis. Sensor responses in other two axes were minimal.

(a) (b) Figure 5. A 3 Hz scratching motion was detected in y-axis, while no x-axis motion was present in the measurement. 4. List of Project Expenditures Parts, electrical components and shipping: $3372.25 + $105.58 + $25.93 + $49.00 + $234.67 + $3381.01 = $7168.44 The list includes parts for two round to circuit finalization, which is very typical in electronics prototyping. Manufacturing of PCB boards and component assembling for the finalized design is another chunk of expenditure. Student support: $2130+ $5120 = $7250 The project supported tuition and stipend for a graduate student in Fall 2011 semester, which totaled $5120. An undergraduate student was hired in Summer 2012 semester for circuit assembling and test, which totaled $2130 of hourly pay. Conclusion Although we were unable to implement clinical testing of this device on children with eczema, the research in the development of the device and information discovered about research testing procedures with a pediatric population was valuable information gained through this research. The team plans to disseminate some of the preliminary findings from this research through professional publication and presentation noting the sponsorship of the NEA. As per our contract, NEA will be reimbursed for any unused funds. Thank you for the support you have given us for this project. Principal Investigator: Cheryl Riley-Doucet, PhD, RN Associate Professor School of Nursing, Oakland University Co-Investigator: Hongwei Qu, PhD Associate Professor School of Engineering and Computer Sciences Research Assistant: Sathish Rajasekaran, PhD (candidate)