Contents Which Tank? A brief description of the tank types available Page 2 About our Custom-Made Tanks Page 3 How to Order Custom-Made Tanks Page 4

Similar documents
Waste Oil Handling, Spill Containment & Lighting

H41 Electrical Stage Aft Air Conditioner Unit Installation

Master Catalogue I August 2011

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *

Fuel Pickup Kit Installation Guide

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

All Marine Solutions

Plugging Home Drains to Prevent Sewage Backup

AIR LINE VALVES AND GAUGES

NFPA31FuelOilPiping 1 Revised

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

lifting stations motralec

Plumbing for retail food businesses

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Isotemp Basic, Slim/B & Slim Square

2010 Residential Water Heater Replacement Check List

Pole Lathe and Shave Horse Design

DIY Poly Digester. What is Supplied in the Kit. Sketch of Arrangement

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Light Duty Commercial Electric Water Heater

Fuel. What you will learn. Things you need before you start. Materials. Tools. When you have finished this module, you should be able to:

FUEL SYSTEM FUEL SYSTEM MERCURY OUTBOARDS FUEL FILTERS & SCREENS EMEA Parts Guide FUEL FILTER INLINE FUEL FILTER INLINE FUEL FILTER

The most advanced Undersink Sullage System with inbuilt controls and alarms.

Reserve Systems, Inc. Automatic Oil Level Systems

Oil Fill, Breather, and PCV Information For PML Small Block Chevrolet Center Bolt Valve Covers

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Operators manual Basic water heater

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Walbro 255lph Inline Fuel Pump Install Procedure

External Visual Inspection Form

LIMITED LIFETIME WARRANTY

SF15K SF05KSS, SF10KSS

Finding and Fixing Oil leaks on the LT5 Engine Marc Haibeck

E. Fowler & Sons Ltd.

All content including text and photographs are protected by law - Copyright 2010 by

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

6 Crankcase Ventilation

B150 Series Commercial Brewer. Direct Plumb Kit

Air Eliminators and Combination Air Eliminators Strainers

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

TRUDESIGN prijslijst update oktober 2015

Blowdown vessels Meeting the requirements of HSE PM60

FILLING AND PURGING THE SYSTEM

TITAN Fuel Tanks. Extended Capacity Replacement Tank for Diesel Chevrolet / GMC Trucks

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

ENVIRONMENTAL HEALTH FACT SHEET NO. 500

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

Revised April (May) 2015

Domestic heating Fuel storage tanks

Water Supply (Water Fittings) Regulations 1999

Section 8 Storage Tanks & Equipment

COOLING SYSTEM Section Page

Civil Engineering Sector Labour-Management Health and Safety Committee

FLASH TANK ECONOMIZER PRODUCT GUIDE

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

Installation Instructions

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

1300 MAXTRAK SPECIFICATION

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

G R O U P. ISO 9001:2008 Certified

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

Installation Instructions S

Waste Oil Collection / Storage

INSTALLATION MANUAL MODEL RP-150

GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.

Spouts and Flow Regulators

Reference in RID/ADR (restructured) to published standards and standards in preparation at CEN TC 23/256/261/268/286/296

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

MARINE SUPPLY SOLUTIONS

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

1 DESCRIPTION OF THE APPLIANCE

CHAPTER 11 HEATING, VENTILATION AND AIR CONDITIONING. Section Title Page

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

SHORELINE SANITATION

Line to Refrigerator Ice/Water Dispenser

INSTALLATION INSTRUCTIONS FOR VW MK5

British Standard Underground Hydrant Range

Guidelines for Precast Concrete Grease Interceptors

innovation quality reliability

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

pvc well casing & drop pipe

MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder

GEET Fuel Processor Plans

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

MFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions

Arapahoe County Residential Water Heater Installation and Inspection Guide

Transcription:

Front Cover

IFC - Blank

Contents Which Tank? A brief description of the tank types available Page 2 About our Custom-Made Tanks Page 3 How to Order Custom-Made Tanks Page 4 About our Standard Size Tanks Page 6 How to Order Standard Size Tanks Page 8 Standard Size Tank Plans Page 10-58 About Diesel Fuel Tanks Page 59 Diesel Fuel Tanks for Marine Survey Page 60-67 Gauges and Tank Sensors Page 68 Fitting Size and Plumbing Guide for Recreational Vehicles Page 70 Fitting Size and Plumbing Guide for Boats Page 72 Frequently used terms Glossary Page 74 Page 1

Which Tank? Atlas Tanks offers two tank options 1. The first is what we call Custom-Made sometimes referred to as fabricated tanks. Custom-made tanks are made to your specifications. You specify the tank dimensions and fitting locations and sizes. These are no compromise tanks, you get exactly what you need. 2. The second option is Standard Size tanks. With standard tanks the size is fixed, however you can have fittings (inlets, outlets & breathers) wherever you need them on the tank. Both tank types are ideal for Freshwater, Greywater, Blackwater and Diesel applications. So which tank should you use? First see if a standard size tank will suit your needs, if so, this is the most economical option. If you can t get a standard size tank close to your ideal, or you need a tank to your exact specifications, a custom-made tank is the solution. See How to order Custom-Made Tanks Page 4 See How to order Standard size Tanks Page 8 Page 2

About Our Custom-Made Tanks Custom-made tanks can be made to just about any shape and size, fittings can be placed at any location on the tank. Custom-made tanks are perfectly suited for use in freshwater, greywater and blackwater installations. Our custom-made tanks are fabricated from 6 & 10 mm thick, food grade polypropylene. We use polypropylene (PP) because it is very strong, highly impact resistant, food grade, corrosion free, light weight and has good working characteristics. Generally custom-made tanks will have baffles at about 350-450 mm centres. Tanks can be as small as 25 litres up to over 4,000 litres to most shapes and sizes. Custom-made tanks are made from flat sheets and are folded and welded to form the required shapes. When completed every tank is pressure tested to 21 kpa, this allows us to check that the tank has no leaks, as well as testing tank integrity. See How to order Custom Made Tanks Page 4 Page 3

How to Order Custom-Made Tanks or get a quote fast Once you have the shape, size, fittings and their locations you need to send us a drawing which we will be able to work from. The following is an overall guide. 1. Draw the basic shape of your tank in relative proportion 2. On your drawing detail all measurements paying particular attention to anything which is critical 3. Indicate on your drawing the location of your fittings and their sizes 4. Double check your dimensions and fittings are correct 5. Mark what application the tank is for ie: fresh/grey/blackwater tank for a boat/motorhome etc 6. On the same page put your contact details, include name, phone, email, delivery & postal address 7. Send your drawing and details to Atlas Tanks; Fax: (07) 5438 2318 Email: atlas@atlastanks.com.au Post: Atlas Tanks 18 Allen Street Moffat Beach QLD 4551 Page 4

375 mm Illustration of how to order custom-made tanks Sample Drawing Only 600 mm 1 1/2 Pick-up (on top) 1150 mm 1 Breathers (on top) 1 1/2 Outlet (on end) 450 mm 1 Inlet (on top) Harry Bloggs Phone 07 5555 Fax 07 5555 Delivery Address; 10 Harrybloggs Road Bloggsville State 1234 Postal Address; PO Box 10 Bloggsville State 1234 Blackwater holding tank for yacht Page 5

About Our Standard Size Tanks Our range of standard tanks are one piece moulded. Standard tanks are extremely strong and light weight, typically the wall thickness is between 6-8mm. Standard tanks are moulded from food grade Polyethylene and are ideal for freshwater, greywater and blackwater applications. Fittings Inlets, outlets, breather and other fittings are supplied as BSPT female threaded ports. Fittings are applied to the tank after moulding and can be located just about anywhere on the tank. Sizes 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2 and 2. Custom-Moulded Tanks O.E.M. Where you have a need for a specific size or shape tank which you use regularly (about 10 per year) we offer our O.E.M. service of custom-made moulded tanks. Custom-made moulded tanks represent outstanding value and convenience. Page 6

Tank Orientation Any tank from our standard range can sit on either tank side or end. Laying Flat On side On End Page 7

How to Order Standard Size Tanks 1. Photocopy the page with the tank you require. 2. On the photocopied tank drawing, clearly mark the locations and sizes of your inlets, outlets and breathers. If exact locations are required, indicate in millimetres the centres of fittings. 3. On the same photocopied page put your contact details, include name, phone, fax, delivery & postal address. 4. Send your drawing and details to Atlas Tanks; Fax: (07) 5438 2318 Email: atlas@atlastanks.com.au Post: Atlas Tanks 18 Allen Street Moffat Beach QLD 4551 Page 8

Illustration of how to order standard tanks Freshwater tank for Motorhome - 400mm - 3/8 Breather (on end) Sample Drawing Only - 500mm - - 1000mm - 50 50 1 Inlet (on end) 1/2 Outlet (on end) 1/2 Drain (on side) 1/2 Connector (on end) Tank: 1000 x 500 x 400 Harry Bloggs Phone 07 5555 Fax 07 5555 Delivery Address; 10 Harrybloggs Road Bloggsville State 1234 Postal Address; PO Box 10 Bloggsville State 1234 approximately 200 litres Page 9

- 345mm - Tank: 1950 x 345 x 160-1950mm - - 160-2 ribs top and bottom approximately 90 litres Page 10

- 900mm - Tank: 1500 x 900 x 300 This tank has internal moulded baffles - 1500mm - - 300mm - approximately 380 litres Page 11

750 Tank: 1400 x 650 x 750 650 1400 SIDE VIEW BAFFLE CONFIGURATION approximately 600 litres Page 12

Tank: 1400 x 650 x 750 WALL STRENGTHENING BAFFLES ON TOP, SIDES AND ENDS. INTERNALLY MOULDED BAFFLES X 2 approximately 600 litres Page 13

- 640mm - plan view Tank: 1400 x 700>640>350 x 335-700mm - - 335mm - - 350mm - - 1400mm - approximately 250 litres Page 14

Tank: 1350 x 450 x 270>385-1350mm - - 450mm - - 385mm - - 270mm - approximately 180 litres Page 15

(tapered side at back) Tank: 1300 x 810>630 x 335-630mm - plan view - 810mm - - 335mm - - 1300mm - approximately 300 litres Page 16

- 560mm - Tank: 1280 x 560 x 170-1280mm - - 170mm - approximately 110 litres Page 17

Caravan Pillow Tank Tank: 1215 x 480 x 190 approximately 100 litres Page 18

- 750mm - Tank: 1200 x 750 x 200-1200mm - - 200mm - approximately 165 litres Page 19

- 540mm - - 470mm - - 1200mm - Tank: 1200 x 470>540 x 390-390mm - approximately 225 litres Page 20

- 400mm - - 1200mm - Tank: 1200 x 400 x 400-400mm - approximately 180 litres Page 21

- 380mm - Tank: 1200 x 380 x 290-1200mm - - 290mm - approximately 120 litres Page 22

- 345mm - Tank: 1200 x 345 x 200-1200mm - - 200mm - approximately 80 litres Page 23

- 345mm - Tank: 1200 x 345 x 150-1200mm - - 150mm - approximately 55 litres Page 24

- 600mm - Tank: 1100 x 600 x 230-1100mm - - 230mm - approximately 140 litres Page 25

- 490mm - Tank: 1070 x 370>490 x 300-1070mm - - 300mm - - 370mm - *even taper both sides Page 26 approximately 110 litres

- 500mm - - 1000mm - Tank: 1000 x 500 x 400-400mm - approximately 185 litres Page 27

- 270mm - Tank: 1000 x 270 x 150-1000mm - - 150mm - approximately 35 litres Page 28

- 650mm - - 950mm - Tank: 950 x 650 x 260-260mm - approximately 150 litres Page 29

- 500mm - - 700mm - - 900mm - Tank: 900 x 500>700 x 500-500mm - approximately 235 litres Page 30

- 900mm - Tank: 900 x 530 x 320-320mm - - 530mm - approximately 145 litres Page 31

- 900mm - Tank: 900 x 450 x 250-250mm - - 450mm - approximately 95 litres Page 32

- 390mm - - 900mm - Tank: 900 x 390 x 300-300mm - approximately 95 litres Page 33

- 650mm - - 850mm - Tank: 850 x 650 x 550-550mm - approximately 285 litres Page 34

- 520mm - - 850mm - Tank: 850 x 520 x 450-450mm - approximately 185 litres Page 35

Caravan Pillow Tank Tank: 845 x 475 x 185 approximately 60 litres 8mm wall thickness Page 36

- 450mm - - 800mm - Tank: 800 x 450 x 350-350mm - approximately 120 litres Page 37

Tank: 800 x 280 x 230-800mm - - 280mm - - 230mm - approximately 45 litres Page 38

Can be mounted under floor & fastened through flange Tank: 770>820 x 200 x 330-820mm - - 200mm - 10 5 flange detail - 330mm - 25mm - 770mm - approximately 45 litres Page 39

- 750mm - Tank: 750 x 750 x 550-750mm - - 550mm - approximately 300 litres Page 40

- 430mm - Suits Toyota Coaster Tank: 720 x 430 x 250-720mm - - 250mm - approximately 70 litres Page 41

Tank: 700 x 100>350 x 100>425 700 350 100 350 (end view) 425 425 100 approximately 70 litres Page 42

- 500mm - Tank: 700 x 500 x 375-700mm - - 375mm - approximately 120 litres Page 43

- 700mm - Tank: 700 x 490 x 290>370-490mm - - 290mm - - 370mm - Page 44-300mm - approximately 100 litres

- 400mm - Tank: 700 x 400 x 300-700mm - - 300mm - approximately 80 litres Page 45

- 400mm - Tank: 700 x 400 x 190-700mm - - 190mm - approximately 45 litres Page 46

Can be mounted under floor & fastened through flange Tank: 650>850 x 450 x 270-850mm - - 450mm - 10 5 flange detail - 270mm - 25mm - 150mm - - 650mm - approximately 85 litres Page 47

Can be mounted under floor & fastened through flange Tank: 650>700 x 450 x 330-700mm - - 450mm - 10 5 flange detail - 330mm - 25mm - 650mm - approximately 90 litres Page 48

- 430mm - Suits Toyota Coaster Tank: 650 x 430 x 250-650mm - - 250mm - approximately 65 litres Page 49

- 350mm - Suits Toyota Coaster Tank: 650 x 350 x 250-650mm - - 250mm - approximately 50 litres Page 50

- 580mm - Tank: 600 x 580 x 280-600mm - - 280mm - approximately 90 litres Page 51

- 400mm - Tank: 600 x 400 x 200-600mm - - 200mm - approximately 45 litres Page 52

Tank: 560 x 400 x 210>320-400mm - - 560mm - - 210mm - - 320mm - *bottom falls from one end to other approximately 50 litres Page 53

- 470mm - Tank: 550 x 470 x 440-550mm - - 440mm - Page 54 approximately 110 litres

- 470mm - Tank: 550 x 470 x 300-550mm - - 300mm - approximately 75 litres Page 55

- 400mm - Tank: 500 x 400 x 300-500mm - - 300mm - approximately 55 litres Page 56

- 400mm - Tank: 500 x 400 x 280-500mm - - 280mm - approximately 50 litres Page 57

- 200mm - Tank: 350 x 200 x 150-350mm - - 150mm - approximately 10 litres Page 58

About Diesel Fuel Tanks We can mould any of the standard size range as a diesel tank. Our diesel fuel tanks are one piece moulded and the material used is specifically formulated for use in diesel tank applications. Typically the wall thickness is 10mm. Fittings Each tank includes an 1-1/2 inlet, 1/2 or 3/8 outlet, 1/2 or 3/8 fuel return, 5/8 breather/vent and an 1-1/4 threaded port for tank sensor. The sensor itself is not included in the cost. Hosetails and pickup straw are included with diesel fuel tanks. Custom-Moulded Tanks O.E.M. Where you have a need for a specific size or shape tank which you use regularly (about 10 per year) we offer our O.E.M. service of custom-made moulded tanks. Custom-made moulded tanks represent outstanding value and convenience. Page 59

Diesel Tank Certified For Marine Survey Tank: 600 x 400 x 200 Included with the tank 1 x 1-1/2 Filler Hosetail 1 x 5/8 Breather Hosetail 1 x 1/2 Pick-Up Hosetail 1 x 1/2 Return Hosetail 1 x 1-1/4 Sensor Port Optional 3/8 Pick-Up Hosetail 3/8 Return Hosetail approximately 40 litres Page 60

Diesel Tank Certified For Marine Survey Tank: 600 x 200 x 400 Included with the tank 1 x 1-1/2 Filler Hosetail 1 x 5/8 Breather Hosetail 1 x 1/2 Pick-Up Hosetail 1 x 1/2 Return Hosetail 1 x 1-1/4 Sensor Port Optional 3/8 Pick-Up Hosetail 3/8 Return Hosetail approximately 40 litres Page 61

Diesel Tank Certified For Marine Survey Tank: 500 x 400 x 300 Included with the tank 1 x 1-1/2 Filler Hosetail 1 x 5/8 Breather Hosetail 1 x 1/2 Pick-Up Hosetail 1 x 1/2 Return Hosetail 1 x 1-1/4 Sensor Port Optional 3/8 Pick-Up Hosetail 3/8 Return Hosetail approximately 52 litres Page 62

Diesel Tank Certified For Marine Survey Tank: 500 x 300 x 400 Included with the tank 1 x 1-1/2 Filler Hosetail 1 x 5/8 Breather Hosetail 1 x 1/2 Pick-Up Hosetail 1 x 1/2 Return Hosetail 1 x 1-1/4 Sensor Port Optional 3/8 Pick-Up Hosetail 3/8 Return Hosetail approximately 52 litres Page 63

Diesel Tank Certified For Marine Survey Tank: 900 x 400 x 300 Included with the tank 1 x 1-1/2 Filler Hosetail 1 x 5/8 Breather Hosetail 1 x 1/2 Pick-Up Hosetail 1 x 1/2 Return Hosetail 1 x 1-1/4 Sensor Port Optional 3/8 Pick-Up Hosetail 3/8 Return Hosetail approximately 100 litres Page 64

Diesel Tank Certified For Marine Survey Tank: 900 x 300 x 400 Included with the tank 1 x 1-1/2 Filler Hosetail 1 x 5/8 Breather Hosetail 1 x 1/2 Pick-Up Hosetail 1 x 1/2 Return Hosetail 1 x 1-1/4 Sensor Port Optional 3/8 Pick-Up Hosetail 3/8 Return Hosetail approximately 100 litres Page 65

Diesel Tank Certified For Marine Survey Tank: 1000 x 500 x 400 Included with the tank 1 x 1-1/2 Filler Hosetail 1 x 5/8 Breather Hosetail 1 x 1/2 Pick-Up Hosetail 1 x 1/2 Return Hosetail 1 x 1-1/4 Sensor Port Optional 3/8 Pick-Up Hosetail 3/8 Return Hosetail approximately 185 litres Page 66

Diesel Tank Certified For Marine Survey Tank: 1000 x 400 x 500 Included with the tank 1 x 1-1/2 Filler Hosetail 1 x 5/8 Breather Hosetail 1 x 1/2 Pick-Up Hosetail 1 x 1/2 Return Hosetail 1 x 1-1/4 Sensor Port Optional 3/8 Pick-Up Hosetail 3/8 Return Hosetail approximately 185 litres Page 67

Gauges and Tank Sensors Atlas Tanks offers the option of a quality gauge and tank sensor for use with fresh/grey & blackwater tanks. These units work just like the fuel tank gauge in your car or motorhome. While power is provided you will have a continuous reading between empty and full. Sensors are fitted through the tank top and reach to the bottom. Sensors for blackwater are a special type with the float unit inside a perforated cover to prevent blockage and malfunction. E ISC F Gauges can be mounted anywhere you need in the vehicle. Gauges are available for Fresh, Grey, Blackwater and fuel tanks. Page 68 Sensor shown is not to scale

E Black Water F E Fuel F E Water F E Grey Water F ISC ISC ISC ISC Water Tank Gauge Grey Water Gauge Black Water Gauge Fuel Tank Gauge Tank Monitor Selector Hold Tank Sensor 1 Segment Hold Tank Sensor 2 Segment Hold Tank Sensor 3 Segment Hold Tank Sensor 4 Segment Hold Tank Sensor 5 Segment Hold Tank Sensor 6 Segment Tank Gauges and Sensors Water Tank Sensor 150mm Water Tank Sensor 200mm Water Tank Sensor 250mm Water Tank Sensor 300mm Water Tank Sensor 350mm Water Tank Sensor 400mm Water Tank Sensor 500mm Water Tank Sensor 600mm Water Tank Sensor 700mm Water Tank Sensor 800mm E ISC F Fresh Grey Water Water Black OFF Water ISC Tank Monitor Tank Monitor Selector Page 69

Fittings Size Guide for Recreational Vehicles Freshwater Plumbing Filling, generally the filler fitting size on your tank will be dictated by the type of filler point you install. Most through body fillers use a 1 fitting. Alternatively you can fill the tank with a cap on the tank itself. Breather, all tanks must have a breather to let air in and out as you fill and drain the tank. Most standard through body fillers have a built in breather connection of 1/2. Outlet, in almost all installations water going to a pump and from the pump to appliances within the vehicle will use a 1/2. Greywater Plumbing Inlets, most appliances drain with a 40 mm fitting (old 1 1/2 ) and this is good practise. Any plumbing less than 40 mm will cause slow draining and ponding in shower units. Breather, a breather of at least 1 is recommended, anything smaller will result in slow discharging of the tank. Page 70 This information is a general overview and is provided as a guide only and does not reflect state regulations or requirements.

Fittings Size Guide for Recreational Vehicles continued Greywater Plumbing Outlet, often the installation will dictate what size of outlet you will have to use. Generally it is ideal to drain the tank with an 1 1/2 outlet, but 1 is also very common. On larger tanks consider the use of a 3 knife valve system with a coupling lay flat hose. The hose can also be used with a knife valve on a blackwater tank. Blackwater Plumbing Inlet, to your blackwater tank will be dictated by the type of toilet that you are using, consult your toilet specifications. We strongly recommend the use of macerating toilets (marine type). Breather, in order to keep odour from your holding tank under control your breather or vent should be as large as possible. Ideally use a 1 1/2 breather. Outlet, it is most common to use an 1 1/2 outlet for blackwater. Another method is to use a knife valve system. A knife valve is mounted to the side or underside of the tank. The knife valve has a bayonet fitting which allows for the attachment of a hose connection which is run to the drain/sewer. Once the hose is in position, open the knife valve and drain away. This information is a general overview and is provided as a guide only and does not reflect state regulations or requirements. Page 71

Fittings Size Guide for Boats Freshwater Plumbing Filling, most commonly boats are filled via a 1 1/2 deck filler, some commercial and/or larger boats with very large capacity tanks use 2. Breather, through hull or through wall breather types are most common and are usually 1/2. Outlet, in almost all installations water going to a pump and from the pump to appliances will be 1/2 plumbing, large vessels sometimes plumb with 3/4. Check your pump specifications. Greywater Plumbing Inlets, generally boats don t have a separate greywater tank where you are plumbing appliances which generate greywater we recommend 1 1/2 but you should also check the outlet sizes on any appliances. Breather, a breather of at least 1 is recommended, anything smaller will result in slow discharging of the tank. Page 72 This information is a general overview and is provided as a guide only and does not reflect state regulations or requirements.

Fittings Size Guide for Boats continued Greywater Plumbing Outlet, as most boats generally use the blackwater or holding tank, see blackwater plumbing. If you are having a greywater tank use at least a 1 1/2 outlet. Blackwater Plumbing Inlet, to your blackwater tank will be dictated by the type of toilet that you are using, consult your toilet specifications. We strongly recommend the use of macerating toilets (marine type). Most macerating toilets and pumps have an outlet size of 1. Most hand pump toilets have an outlet size of 1 1/2. Breather, in order to keep odour from your holding tank under control your breather or vent should be as large as possible. The Australian Standard for holding tanks onboard pleasure boats call for a 1 1/2 breather, while this is ideal it is not always possible. Fit the largest breather your installation allows, if you can only fit 1/2 then consider fitting 2 breathers. Outlet, going to a deck fitting for pump out at a marina will be universally 1 1/2. Outlet going to a macerating pump then through the hull overboard will be 1 1/2 to the pump. Hand pump to pump overboard will usually be 1 1/2, check pump specifications. This information is a general overview and is provided as a guide only and does not reflect state regulations or requirements. Page 73

Frequently Used Terms Freshwater = Drinking water Greywater = Water from sinks, showers Blackwater = Waste from toilet Holding Tank = Blackwater tank Potable water = Drinking water Macerator/ing = Change from solid to sludge Pick-up = Outlet on top of tank Straw = Outlet on top of tank Breather = Fitting to allow air in and out Vent = Fitting to allow air in and out Hosetail = Fitting used between tank and hose Knife Valve = Outlet fitting on blackwater tank Gate Valve = Outlet fitting on blackwater tank Slide Valve = Outlet fitting on blackwater tank Weight = 1 litre equals 1 kilogram Threaded Port = A hole in tank with female thread BSPT = British Standard Plumbing Tapered Gauge = Method of indicating tank contents amount Sensor = Device used to measure tank contents Sight Gauge = Clear tube to show contents amount Inspection Port = Used to gain access to the inside of tank Page 74

IBC - Blank