Similar documents
X2Y Solution for Decoupling Printed Circuit Boards

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout

G019.A (4/99) UNDERSTANDING COMMON MODE NOISE

Conducted EMI filter design for SMPS

Lecture 24. Inductance and Switching Power Supplies (how your solar charger voltage converter works)

Current Ripple Factor of a Buck Converter

AN-837 APPLICATION NOTE

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

EMI and t Layout Fundamentals for Switched-Mode Circuits

Module 11: Conducted Emissions

Inductors & Inductance. Electronic Components

AN48. Application Note DESIGNNOTESFORA2-POLEFILTERWITH DIFFERENTIAL INPUT. by Steven Green. 1. Introduction AIN- AIN+ C2

WHITE PAPER. Preventing and Attacking Measurement Noise Problems. White Paper Code: 2 Revision: 1. Copyright (C) 2001 Campbell Scientific, Inc.

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

Coupled Inductors. Introducing Coupled Inductors

Balanced vs. Unbalanced Audio Interconnections

ILB, ILBB Ferrite Beads

Transmission Line Transformers

AND9015. A Solution for Peak EMI Reduction with Spread Spectrum Clock Generators APPLICATION NOTE. Prepared by: Apps Team, BIDC ON Semiconductor

Pulsed Power Engineering Diagnostics

Understanding SMD Power Inductors. Application Note. July 2011

Chapter 11. Inductors ISU EE. C.Y. Lee

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

ES250: Electrical Science. HW7: Energy Storage Elements

AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE

Measuring Impedance and Frequency Response of Guitar Pickups

Mutual Inductance and Transformers F3 3. r L = ω o

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

Capacitor Self-Resonance

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011

DC-DC Converter Basics

Since any real component also has loss due to the resistive component, the average power dissipated is 2 2R

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

11: AUDIO AMPLIFIER I. INTRODUCTION

Line Reactors and AC Drives

POWER LINE FILTERS FOR SWITCHING POWER SUPPLIES

EE 1202 Experiment #4 Capacitors, Inductors, and Transient Circuits

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

= V peak 2 = 0.707V peak

Signal Types and Terminations

Which is the best PFC stage for a 1kW application?

Critical thin-film processes such as deposition and etching take place in a vacuum

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Crosstalk effects of shielded twisted pairs

Design Challenges for PoDL Coupling Circuit in 100BASE-T1 and 1000BASE-T1

Application Note, Rev.1.0, September 2008 TLE8366. Application Information. Automotive Power

MEASUREMENT SET-UP FOR TRAPS

Printed Circuit Boards. Bypassing, Decoupling, Power, Grounding Building Printed Circuit Boards CAD Tools

Eðlisfræði 2, vor 2007

Edmund Li. Where is defined as the mutual inductance between and and has the SI units of Henries (H).

Inductors in AC Circuits

Output Filter Design for EMI Rejection of the AAT5101 Class D Audio Amplifier

AND8326/D. PCB Design Guidelines for Dual Power Supply Voltage Translators

5. MINIMIZATION OF CONDUCTED EMI. Chapter Five. switch-mode power supply decrease approximately linearly with the increase of the switching

Electronic Circuits Workshop Snap Circuits

Broadband Slotted Coaxial Broadcast Antenna Technology

Inrush Current. Although the concepts stated are universal, this application note was written specifically for Interpoint products.

This application note is written for a reader that is familiar with Ethernet hardware design.

Tag Tuning/RFID. Application Note. Tag Tuning. Introduction. Antenna Equivalent Circuit

Physics 2102 Lecture 19. Physics 2102

A Practical Guide to Free Energy Devices


Current Probes, More Useful Than You Think

PS25202 EPIC Ultra High Impedance ECG Sensor Advance Information

An equivalent circuit of a loop antenna.

AC Generators. Basic Generator

Measurement setup for differential-mode and common-mode channels

Diodes have an arrow showing the direction of the flow.

ELECTRON SPIN RESONANCE Last Revised: July 2007

BIASING OF CONSTANT CURRENT MMIC AMPLIFIERS (e.g., ERA SERIES) (AN )

LAB 12: ACTIVE FILTERS

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

Capacitors in Circuits

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

RS485 & RS422 Basics

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Design and Applications of HCPL-3020 and HCPL-0302 Gate Drive Optocouplers

Application Note. So You Need to Measure Some Inductors?

Common Mode Filter Inductor Analysis

Balun Parameter Definitions & Measurement May 2004

Issues and Solutions for Dealing With a Highly Capacitive Transmission Cable

Application Note 58 Crystal Considerations with Dallas Real Time Clocks

GenTech Practice Questions

1 pc Charge Injection, 100 pa Leakage CMOS 5 V/5 V/3 V 4-Channel Multiplexer ADG604

Design of Bidirectional Coupling Circuit for Broadband Power-Line Communications

EMI in Electric Vehicles

Outline. Systems and Signals 214 / 244 & Energy Systems 244 / 344. Ideal Inductor. Ideal Inductor (cont... )

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants

Nexus Technology Review -- Exhibit A

Introduction to the Smith Chart for the MSA Sam Wetterlin 10/12/09 Z +

Yaesu FT MHz PA output and filter simulations Marc Vlemmings, PA1O - Eindhoven, The Netherlands

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

Chapter 4: Passive Analog Signal Processing

Transcription:

Summary Introduction This application note gives a practical explanation of differential mode and common mode noise along with the traditional filtering approaches. In addition, an alternative method of filtering is shown using X2Y components. In an ideal circuit, the signal from the source and load would require no filtering. Figure 1 represents the ideal circuit s current path. The signal current, I S, flows on the positive conductor and signal s return current, I r, flows on the negative conductor. The relationship between the current on the two conductors is I s = -I r. I s and I r have the same magnitude, but different polarity. Differential Mode Noise Current Figure 1. The desired circuit s current path. Noise current that flows in the same directions as I s and I r is called differential mode noise or I d, see Figure 2. The total current on the positive conductor is I t_pos = I s + I d. Conversely, the total current on the negative conductor is I t_neg = I r + I d. The relationship between I t_pos and I t_neg follows the same relationship, I t_pos = -I t_neg. The relationship between the current on the two conductors is I s = -I r. I s and I r have the same magnitude, but different polarity. Figure 2. The effects of differential mode current in a circuit. DISCLAIMER: Information and suggestions furnished in this document by X2Y Attenuators, LLC are believed to be reliable and accurate. X2Y Attenuators, LLC assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. X2Y is a registered trademark. All other brand or product names mentioned in this document are trademark or registered trademarks of their respective holders. These notes are subject to change without notice. Copyright X2Y Attenuators, LLC all rights reserved. Note# 2001, v4.0, 4/20/05 Page 1 of 10

To attenuate differential mode current in a circuit, a standard capacitor is used in an x-cap configuration, Figure 3. The value of the capacitor is chosen by matching the frequency of I d with the self-resonant frequency of the capacitor. At self-resonant frequency, the capacitor is at minimum impedance and provides an alternative return path to the source. By filtering out I d, the load receives only the desired signal generated by the source. Common Mode Noise Current Figure 3. x-cap configuration to minimize differential mode current. Noise current that flows in the same directions on both the positive and negative conductors, as shown in Figure 4, is called common mode noise or I c. The total current on the positive conductor is I t_pos = I s + I c. Conversely, the total current on the negative conductor is I t_neg = I r I c. The relationship between I t_pos and I t_neg is no longer an equal magnitude with different polarities. The circuit has become unbalanced; the source and load impedance are no longer equivalent with respect to ground. 1 Figure 4. The effects of common mode current in a circuit. Note I t_neg and I t_pos do not have the same magnitude. One approach to attenuate common mode current in a circuit is to use two standard capacitors in a y-cap configuration, Figure 5. Once again, the value of the capacitor is chosen by matching the frequency of I c with the self-resonant frequency of the capacitor. Note# 2001, v4.0, 4/20/05 Page 2 of 10

Figure 5. y-cap configuration to reduce common mode noise current. Special care must be taken to ensure that the capacitors are as tightly matched as possible. For example, the goal of the y-cap configuration is to filter out I c and match the magnitudes of I s and I r. If two capacitors are used that have a capacitance tolerance of ±10%, a 20% discrepancy can exist in the amount of attenuation performed between the two conductors. A second approach to attenuate common mode current in a circuit is to use feedthrough capacitors, see Figure 6. Feedthrough capacitors are able to work at higher frequencies and are more broadband than standard capacitors. The disadvantage of feedthrough capacitors are higher cost and added impedance to the circuit of 0.2 to 0.6 ohms. In low voltage applications this could be an important consideration. Figure 6. Common mode filtering using feedthrough capacitors. A third approach to attenuate common mode current on a single conductor is to use an inductor, see Figure 7. An inductor in series acts like a short at DC and low frequencies. At high frequencies an inductor acts like an open. The voltage across an inductor is related to current by the rate of change in current. di V = L dt Note# 2001, v4.0, 4/20/05 Page 3 of 10

When current flows through the inductor magnetic flux is created. If the change in current is from a positive value, I +, to a negative value, I -, then the magnetic field will collapse and form magnetic flux in the opposite direction (use right-hand rule). At high frequencies the magnetic field cannot form because the rate of current change is too fast. Figure 7. Common mode filtering using inductors. A fourth approach to attenuate common mode current is to use a common mode choke, see Figure 8. Common mode chokes works like an inductor with an added feature. The common mode current creates a flux. Since the flux created by each conductor is in the same direction it adds. This field causes a large impedance thus choking the throughput of the common mode current on the conductors 2. I S and I R are differential signals and the mutual inductance of each cancels with the inductance of the choke resulting in I S and I R passing through the choke onto the load. Figure 8. Common mode filtering using a common mode choke. The fifth type of filter uses ferrite material that provides high impedance at the frequencies of the unwanted noise. The ferromagnetic material absorbs the noise and dissipates it as heat, due to a time varying magnetic field, see Figure 9. Note# 2001, v4.0, 4/20/05 Page 4 of 10

Common Mode and Differential Mode Current Figure 9. Common mode filtering using ferrites. To filter both common mode and differential mode noise current in a circuit, a combination of previous solutions can be used. Figure 10 - Figure 13 shows common filter configurations for both differential and common mode current. Figure 10. x-cap and y-cap configuration for common mode and differential mode noise filtering. Figure 11. Feedthrough capacitors and an x-cap configuration for common mode and differential mode noise filtering. Note# 2001, v4.0, 4/20/05 Page 5 of 10

Figure 12. x-cap, y-cap, and inductors for common mode and differential mode noise filtering. The inductors broaden the common mode filtering range. Figure 13. x-cap, y-cap, and common mode choke for common mode and differential mode noise filtering. The common mode choke broadens the common mode filtering range. Figure 14. x-cap and ferrites for common mode and differential mode noise filtering. Note# 2001, v4.0, 4/20/05 Page 6 of 10

New Technology in Noise Filtering Typical filters for common mode and differential mode noise usually consist of 3-7 standard discrete components. This section introduces a new technology in noise filtering. An X2Y component is a single component that performs the same function that the multiple traditional components do, Figure 15. Figure 15. X2Y can easily replace 3-7 discrete components when used as a filter. X2Y outperforms discrete components because of its unique internal structure. The X2Y design is similar to a dual rectangular coaxial structure that was studied and modeled by the National Bureau of Standards 3. The internal Faraday cage forms a shielded container for each conductor inside the capacitor. At high frequency, the circuit noise in each capacitor will choose the low impedance path of the shield and opposing noise currents will cancel. Figure 16. X2Y compared to a dual rectangular coaxial structure. X2Y is a circuit inside a capacitor that can operate simultaneously in multimodes. The unique internal electrode arrangement creates two tightly balanced capacitors. Typical capacitance tolerance is 1-3 %, when each capacitor is measured from A to G1 and B to G2. Note# 2001, v4.0, 4/20/05 Page 7 of 10

Figure 17. Side view of dual Transverse Electromagnetic (TEM) model. Figure 18 depicts a measurement sequence of X2Y versus a discrete x-cap and two y-capacitor configurations. Figure 19 plots the comparison data of the different measurements. Figure 18. Depiction of measurement sequence. Note# 2001, v4.0, 4/20/05 Page 8 of 10

Figure 19. Comparison data, X2Y vs. discrete x-cap and 2 y-cap configurations. As shown in Figure 19, X2Y has a 34dB improvement in insertion loss for differential mode at low frequency and 18dB at high frequency. Common mode has a 5 db insertion loss improvement at high frequency. Conclusion X2Y provides an alternative to standard components used to filter common mode and differential mode noise voltage. The advantages of a single X2Y component are: Replaces 3-7 standard discrete components. Large improvement in attenuation. Reduction of PC board space. Application Note#1003 - Internal Model of X2Y Chip Technology will further explain how the X2Y accomplishes the dramatic improvement in circuit performance. For this and other test results go to www.x2y.com. Note: Performance results reported in this and other application notes can only be achieved with patented X2Y components sourced from X2Y licensed manufacturers or their authorized distribution channels. References 1 Ott, Henry, Noise Reduction Techniques in Electronic Systems, 2 nd edition. Page 116, John Wiley & Sons, 1988. Note# 2001, v4.0, 4/20/05 Page 9 of 10

2 Paul, Clayton R. Introduction to Electromagnetic Compatibility, pages 301-304, John Wiley & Sons, 1992. 3 Theoretical and Experimental Analysis of Coupling Characteristics of Dual TEM Cells by P.F. Wilson, D.C. Chang, Department of Electrical Engineering, University of Colorado & M.T.Ma, M.L. Crawford, Electromagnetic Fields Division, National Bureau of Standards, Boulder, CO 80303 1983 IEEE. Contact Information Direct inquiries and questions about this application note or X2Y products to x2y@x2y.com or telephone: X2Y Attenuators, LLC 2730B West 21 st Street Erie, PA 16506-2972 Phone: 814.835.8180 Fax: 814.835.9047 To visit us on the web, go to http://www.x2y.com. Note# 2001, v4.0, 4/20/05 Page 10 of 10