Hazardous location controls and apparatus. Getting you closer. ACE series explosionproof variable frequency drives



Similar documents
Explosion-Proof Electric Unit Heaters

Specifying a Variable Frequency Drive s

Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure

EDS / EFS Series Control Stations

PSR The compact range Description

Phone: Fax: Web: info@clrwtr.com

EDS / EFS Series Control Stations

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

8146/5 Series Breaker Panelboards

GUE, GUB Junction Boxes

Magnum Mobile Generator MMG55 Specifications

Champ VMV Series. 3,000 to 25,000 lumen LED high bay luminaires. LED luminaires for hazardous areas

B-Series Temperature Switches

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

GE Energy Industrial Solutions. New. AF-6 Series Drives. Built-in features Built-in simplicity. GE imagination at work

Panorama. Softstarters The complete range

Screw Plug Immersion Heaters

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

We will discuss common industrial applications with guides for the proper use of electric motors on these.

SmartVFD HVAC and BYPASS

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

Scraper Passage Indicator. Electrical Indicator. Features

Commercial Gas Furnace Upflow

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

Rotary Screw Compressors UP-Series 4 & 5.5 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

STB Series Enclosures

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

DuroSite LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

Controlled Start transmission

Compact pressure switch Flameproof enclosure Ex d Model PCA

Efficient and reliable fans, compressors and blowers

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

Product Brochure. Certified Mining Motors

Rotary screw compressors kw 5,5 7, , bar MODULO

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Hazardous area LED lighting Vaporgard LED Luminaires. Vaporgard LED. Low profi le incandescent replacement

B a l d o r V S 1 A C M i c r o d r i v e s C o m p a c t. C o s t E f f i c i e n t. R e l i a b l e.

Product Brochure. Controlled start transmission

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

, User s Manual

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

T7079A,B Solid State Remote Temperature Controllers

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Plugs and Receptacles

Energy Saving ECM Motors and Fans Ventilation Catalogue

Sigma Frequency Control

HOSHIZAKI AMERICA, INC.

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

Diesel Engine Driven Generators Page 1 of 6

Variable Speed Drives

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

32VFD Variable Frequency Drives for Centrifugal Chillers

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

HVAC DRIVE H300 HVAC Drive for Building Automation

Softstarters Type PSR

Electronic, Digital and Mechanical Vibration Switches

Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN

Desiccant Air Dryers Heatless, Heated and Heated Blower

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION

The Silencer. Silencer Outdoor Air Blower, The Name That Says It All. Quality Product. Call for more information

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

Adsorption air dryers ADS 1 215

Laminar Flow Cabinets

Medical Air Systems: Scroll

CE6500 Energy Recovery Ventilator

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

ADDENDUM #1(BID PACKAGE # 3)

IV. Rear Mount System

For Multi-Parameter Meters see mvx

Electronic Flow Switches

Commercial Portable Air Conditioners

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Clinic Washer-Disinfectors. Washer-Disinfector Line

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

FLB Series Circuit Breakers and Enclosures

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Number 1 in efficiency

REFRIGERATED COMPRESSED AIR DRYERS

Vacuum drying oven for non-flammable solvents

Microcor Wireless Transmitter (MWT)

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

Cooking at the Speed of light!

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Softstarters. Index. 5 - Softstarters. Phone: Fax: Web: info@clrwtr.com.

API Flanged Safety Relief Valves Series 526 CATALOG

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

In-Line Electronic Flow Switches

PAINT BOOTH LIGHTING

Cooktop Low-Profile Ventilation Hoods

Integrated Automation Solutions

Transcription:

Hazardous location controls and apparatus Getting you closer ACE series explosionproof variable frequency drives

An industry first... Explosionproof VFDs Deliver installation savings, conserve energy & improve performance. The Class I Dilemma Until now, a VFD couldn t be used inside a classified enclosure in Class I, Division 1 or 2 locations. The heat generated by the VFD inside the classified enclosure caused it to fail. To overcome this problem, VFDs had to be stationed in control rooms outside of the hazardous area, resulting in expensive and impractical installation costs. But what if you could station VFDs exactly where you want them, literally mounting the drives next to motors inside Class I areas? This would provide: A significant reduction of construction and installation costs The elimination of logistical and engineering problems An increase in uptime Crouse-Hinds has developed just such a solution the ACE Series Explosionproof Variable Frequency Drive. It is the only explosionproof enclosure to safely and reliably house a VFD. This revolutionary new product features a NEMA 7 enclosure with patent pending active cooling technology, allowing a traditional VFD to be housed inside the classified enclosure without the risk of overheating. The ACE Explosionproof VFD is rated Class I, Divisions 1 and 2 for use in the most extreme hazardous environments, and it is designed to match the high requirements of pumps, compressors, fans, separators, and mixers in the following process industries: Oil and gas/refineries OEM skid builders Petrochemical Water/waste water Pharmaceutical Food & beverage manufacturing The Solution that Drives Benefits ACE Explosionproof VFDs are the optimal choice for motor control in Class I, Division 1 and 2 locations for a number of reasons. Simple and Cost Effective Installations ACE Explosionproof VFDs can be installed inside hazardous areas right next to the operation, eliminating expensive, complicated installations. There is no need to run long lines of conduit and motor cable, navigate around obstacles and hazards, or build off-site control rooms in non-hazardous areas to house VFD clusters. Reduced Energy Usage ACE Explosionproof VFDs allow you to adjust the motor s level of power to exactly what is needed for optimal performance, significantly lowering energy consumption. Reduced Downtime Builtin diagnostics monitor equipment information and operating conditions, bringing visibility to potential issues before they become problems. Maintenance can be proactively scheduled during non-production hours. Lower Maintenance Costs The ACE Explosionproof VFDs ability to lower system speeds and loads, as well as its soft start and stop capabilities, helps eliminate water hammer effects, increase life on bearings and seals and reduce stress on the overall electrical system. 2 EATON'S CROUSE-HINDS Hazardous location controls & apparatus

big savings, optimized performance Installation and Energy Savings Application An oil refinery utilizes thousands of pumps throughout the facility, many of them in hazardous areas. in an effort to improve their bottom line, the owners would like to control the pumps with VFDs and capture the energy savings they provide. Problem There is no space in the non-classified control room for VFDs. Also, the cost to engineer and install conduit and motor cable from the non-classified area to the pumps in the hazardous area is prohibitive. Solution Install Crouse-Hinds ACE Series Explosionproof VFDs right next to the motor and pump, tapping into an existing 480V supply. Benefit By using a VFD to optimize pump flow, significant energy savings are realized. Additionally, by installing the VFD next to the pump and motor, installation costs are greatly reduced. protect systems and motors Reduced Maintenance Application A waste water treatment plant wants to reduce maintenance costs by installing VFDs on their pumps to eliminate the effects of water hammer in their pipes, which causes damage to the pipe system and its appendages. Problem The cost to run motor cable and conduit, coupled with the added cost of filters to mitigate the effects of Reflected Wave Syndrome (due to long cable lengths), makes installing the VFDs in a nonclassified area impractical. Solution Install Crouse-Hinds ACE Series Explosionproof VFD in the classified area, thereby eliminating costly installations and protecting against the possibility of reflected wave syndrome by keeping motor cable runs short. Additionally, the VFDs soft start and stop capabilities eliminate water hammer. Benefit Total cost of ownership is reduced by protecting both the piping system and the motor itself with a classified solution that is easy to install. proactively schedule maintenance Downtime Reduction Application A petrochemical plant is experiencing an unacceptable amount of downtime in critical processes, costing the facility tens of thousands of dollars per hour. The plant manager has been tasked with determining the problem and proposing a solution. Problem The motors throughout the facility are controlled by basic "acrossthe-line" motor starters and unexpected motor failure is the biggest reason for unscheduled down time. Solution Installing Crouse-Hinds ACE Series Explosionproof VFDs throughout the facility will provide access to real-time equipment and process data. Employees can monitor rises in average motor current, accurately predicting imminent bearing failure. Benefit Using a VFD to access and analyze real-time equipment data significantly reduces plant downtime, as the plant manager is now able to proactively schedule motor change out maintenance during non-production hours. EATON'S CROUSE-HINDS Hazardous location controls & apparatus 3

1.5 to 60 HP Variable Frequency Drive (VFD) in explosionproof enclosure allows installation in classified area, providing significant installation savings. Fused disconnect. Internal and external grounding lugs. 4 EATON'S CROUSE-HINDS Hazardous location controls & apparatus

Shroud* covering top filters maintains NEMA 4X rating. Stainless steel, captive, triple lead quick release spring loaded bolts install faster and provide clear indication that the cover bolts are fully retracted from the body. Stainless steel hinges provide convenient and easy access to enclosure interior. Explosionproof window allows for viewing of the VFD interface module LCD screen. Explosionproof pilot lights provide run, stop, and alarm indication. Explosionproof keypad allows operation of VFD interface module without opening the enclosure door. Heavy duty blower* creates airflow through the enclosure, allowing VFD to operate in ambient temperatures up to 50ºC. Filters* in top and bottom of enclosure allow airflow into and out of the enclosure, cooling the VFD and eliminating risk of overheating. Pre-filter screens* (not shown) eliminate clogging of the primary filters, ensuring reliable and consistent airflow. Pre-filter screens can be easily removed and cleaned without shutting down operations. Enclosure epoxy painted for superior corrosion resistance. * Heavy duty blower, shroud, filters, and pre-filter screens not included with units containing 1.5 to 5.0 horsepower VFDs. EATON'S CROUSE-HINDS Hazardous location controls & apparatus 5

75 HP Variable Frequency Drive (VFD) in explosionproof enclosure allows installation in classified area, providing significant installation savings. Fused disconnect. Internal and external grounding lugs. 6 EATON'S CROUSE-HINDS Hazardous location controls & apparatus

Shroud covering top filters maintains NEMA 4X rating. Stainless steel, captive, triple lead quick release spring loaded bolts install faster and provide clear indication that the cover bolts are fully retracted from the body. Stainless steel hinges provide convenient and easy access to enclosure interior. Explosionproof window allows for viewing of the VFD interface module LCD screen. Heavy duty blower creates airflow through the enclosure, allowing VFD to operate in ambient temperatures up to 50ºC. Filters in top and bottom of enclosure allow airflow into and out of the enclosure, cooling the VFD and eliminating risk of overheating. Pre-filter screens eliminate clogging of the primary filters, ensuring reliable and consistent airflow. Pre-filter screens can be easily removed and cleaned without shutting down operations. Enclosure epoxy painted for superior corrosion resistance. Explosionproof pilot lights provide run, stop, and alarm indication. EATON'S CROUSE-HINDS Hazardous location controls & apparatus 7

Specifi cations Applications For speed control of pumps, compressors, fans, conveyors, separators, mixers, and other process equipment. Designed to meet the high reliability and safety requirements of process industries such as oil and gas, chemical and mining. ACE Series System Benefits ACE Explosionproof VFDs are installed on-machine inside the hazardous areas, eliminating expensive, complicated installations. There is no need to run long lines of conduit and motor cable, dig up roadways and sidewalks, navigate around obstacles and hazards or build off-site control rooms in nonhazardous areas to house VFD clusters. Reflected Wave Syndrome is eliminated due to short motor cable runs. Certifications & Compliances UL Classified Class I, Divisions 1 and 2, Groups B, C, D cul Classified Class I, Divisions 1 and 2, Groups B*, C, D * 5HP and below listed for Group B Standards UL1203 Environmental Ratings NEMA 3, 4X, 7BCD Raintight Wet Locations Operating Temperature Range -10ºC to 50ºC (14ºF to 122ºF) Standard Materials & Finishes Body and Cover Copperfree aluminum, epoxy powder coated Operating Handle Copperfree aluminum, epoxy painted Window Tempered soda lime glass Blower Aluminum, natural Filters Stainless steel, natural Pre-filters Stainless steel, natural Disconnect Stainless steel, natural Shroud Copper-free aluminum, epoxy painted Cover Hinges, Bolts, Washers and Springs Stainless Steel, natural Internal Brackets Stainless steel, natural Manifold and Intake EPDM rubber, natural VFD System Specifications ABB low voltage, compact AC drives - ABB ACS850 Series (1-60 HP) - ABB ACS800 Series (75 HP) Horsepower Ratings Available from 1.5 to 75HP 8 EATON'S CROUSE-HINDS Hazardous location controls & apparatus

Part number confi guration and replacement parts Horse Power Rating Base Part Number Nominal HP (KW) Max Disconnect Rating (Amps) Disconnect Fuse Type Enclosure Size Input Ratings (Amps) Max Output Rating (Amps)* Power Loss (Watts) Temp. Rating ACE10 1 1.5 (1.1) 30 J 1 2.3 3.0 106 T6 ACE10 2 2.0 (1.5) 30 J 1 3.6 3.6 112 T6 ACE10 3 3.0 (2.2) 30 J 1 4.0 4.8 132 T6 ACE10 5 5.0 (3.0) 30 J 1 6.6 8.0 178 T6 ACE10 7 7.5 (5.5) 30 J 1 12.0 12.2 606 T4A ACE10 10 10.0 (7.5) 30 J 1 16.0 15.6 674 T4A ACE10 15 15.0 (11.0) 60 J 2 20.0 23.0 737 T4A ACE10 20 20.0 (15.0) 60 J 2 26.0 30.0 737 T4A ACE10 25 25.0 (18.5) 60 J 2 30.0 35.0 847 T4A ACE10 30 30.0 (22.0) 60 J 2 36.0 44.0 903 T4A ACE10 40 40.0 (30.0) 100 J 2 55.0 58.0 1217 T4A ACE10 50 50.0 (37.0) 100 J 2 65.0 72.0 1397 T4A ACE10 60 60.0 (45.0) 100 J 2 82.0 81.0 1577 T4A ACE10 75 75.0 (55.0) 200 J 3 94.0 96.0 1845 T4A *All models ACE10 1 through ACE10 60 use ABB ACS850 VFD. ACE10 75 uses ABB ACS800 VFD. Please refer to instruction sheet for information on potential de-rating for elevated ambient, elevation or low motor noise Catalog Number Example Horse Power Rating Options Current Rating ACE10 60 CE PT FJ90 Current Rating for Bussmann Fuses FJ Fuse Type J Current Rating NOTE: Add 5 amps to your requirements to account for cooling system blower and round up to the nearest increment of 5 ABB ACS850 VFD with 60 HP Rating Options Ethernet Communications Potentiometer Fuse (81A requirement + 5A for blower, rounded up to 90) Communication Modules Part Number Suffix Description Potentiometer Part Number Suffix Description CP Profibus PT AB 800H-UP24 CD Devicenet CC CAN Open CM Modbus CE Ethernet Replacement Part Kits Part Number Suffix ACE KIT 1 ACE KIT 2 ACE KIT 3 ACE KIT 4 Description Pre-filter and hardware (1 piece) Filter assembly (1 piece) Blower, manifold and hardware (1 piece) Push button operator, finger and hardware (1 piece) EATON'S CROUSE-HINDS Hazardous location controls & apparatus 9

Dimensions Enclosure Size 1 (1.5 to 5.0 Horsepower VFDs) 25.08 [637.0] 15.08 [383.0] 21.83 [554.5] 31.98 [812.2] 17.25 [438.2] 9.38 [238.2] 4.40 [111.7] 9.22 [234.2] 6.16 [156.6] 5.00 [127.0] 5/8" BOLT (4 PLACES) 6.75 [171.3].50 [12.7] 3.50 [88.9] 3.70 [94.0] 8.00 [203.2] 1" NPT 1-1/2" NPT (2 PLACES) Dimensions Enclosure Size 1 (7.5 to 10.0 Horsepower VFDs) 632 24.88 399.8 15.74 555.6 21.88 856.1 33.71 438.2 17.25 238.2 9.38 230.9 9.09 111.7 4.40 127.1 5.00 234.2 9.22 101.5 4.00 5/8" BOLT (4 PLACES) 171.5 6.75 12.7.50 387.4 15.25 106.6 4.20 215.8 8.50 1" NPT 1-1/2" NPT (2 PLACES) 10 EATON'S CROUSE-HINDS Hazardous location controls & apparatus

Dimensions Enclosure Size 2 (15 to 60 Horsepower VFDs) 638.8 25.15 399.8 15.74 555.6 21.88 1176.3 46.31 717.6 28.25 559.4 22.02 432.9 17.04 281.5 11.08 5/8" BOLT (4 PLACES) 414.1 16.30 240.8 9.48 112.2 4.42 148.7 5.85 88.8 3.50 203.2 8.00 12.7.50 93.9 3.70 228.5 9.00 1" NPT 2" NPT (2 PLACES) Dimensions Enclosure Size 3 (75 Horsepower VFD) 778.5 30.65 381 15.00 7/8" BOLT (4 PLACES) 1797.1 70.75 1727.2 68.00 698.6 27.50 396.9 15.63 2" NPT (2 PLACES) 571.5 22.50 673.1 26.50 224.4 8.84 1" NPT 211.7 8.34 201.1 7.92 126.6 4.98 473.2 18.63 266.7 10.50 165.1 6.50 EATON'S CROUSE-HINDS Hazardous location controls & apparatus 11

U.S. (global headquarters): Eaton's Crouse-Hinds business 1201 Wolf Street Syracuse, NY 13208 (866) 764-5454 FAX: (315) 477-5179 FAX Orders Only: (866) 653-0640 crouse.customerctr@ Canada Toll Free: 800-265-0502 FAX: (800) 263-9504 FAX Orders only: (866) 653-0645 Mexico/Latin America/Caribbean 52-555-804-4000 FAX: 52-555-804-4020 Middle East (Dubai) 971 4 4272500 FAX: 971 4 4298521 sales.cch.me@ Singapore 65-6645-9888 FAX: 65-6297-4819 Korea 82-2-3484-6783 82-2-3484-6778 CCHK-sales@ Australia 61-2-8787-2777 FAX: 61-2-9609-2342 For more information: mxmercadotecnia@ chsi-sales@ CEASales@ If further assistance is required, please contact an authorized Eaton Distributor, Sales Office, or Customer Service Department. Europe (Germany) 49 (0) 6271 806-500 49 (0) 6271 806-476 sales.cch.de@ China 86-21-2899-3600 FAX: 86-21-2899-4055 cchsales@ India 91-124-4683888 FAX: 91-124-4683899 cchindia@ Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2015 Eaton All Rights Reserved Printed in USA Publication No. 5106-0815 August 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners.