Ambient Temperature Sensor TEMPSENSOR-AMBIENT



Similar documents
Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Accessories SUNNY REMOTE CONTROL

SUNNY BEAM USB Driver Installing the Sunny Beam USB Driver. 1 Sunny Beam USB Driver. Version: 1.4

System Monitoring SMA Safety and Password Concept for Password-protected PV Plants with Bluetooth Wireless Technology

Communication interface for SMA inverters SMA WEBCONNECT DATA MODULE

Sunny Boy Accessories SMA POWER BALANCER

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Firmware Update with SD Card SUNNY BOY WINDY BOY SUNNY TRIPOWER

Operating Instructions

Communication Interface for SMA Inverters SMA SPEEDWIRE/WEBCONNECT DATA MODULE

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Monitor Simply and Securely

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Simple and secure monitoring

Addendum to the Operating Instructions

Unpacking, Installation, and Customization

3M Wrist Strap and Footwear Tester 740. User s Guide

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

Operating Manual POWER PLANT CONTROLLER

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Infrarot-Bewegungsmelder IP44

Advantium 2 Plus Alarm

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

MIC-WKT and MIC-WKT-IR

UniStream CPU-for-Panel

Installation Manual SMA CLUSTER CONTROLLER

HP 16/18-Port Cable Management Kit Installation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

KNX R. Rain Sensor. Installation and Adjustment

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Modular I/O System Analog and Digital Interface Modules

RAY-MAX Integrated Solar Power Strip

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

SDX Submersible Depth Transmitter User Manual

804 Ti Stand. Manual EN

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd.

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Terminal Boxes Series 8146

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

AM/FM ANTENNA KIT (TOUR-PAK MOUNT)

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

AutoDome Easy II. VEZ Series. Mounting Manual

SunMaxx Solar Filling Station Operating Instructions

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

CUSTOM AUXILIARY FORWARD LIGHTING KIT

T0118 T2118 T3118. Instruction Manual

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

AMERBRITE UNDERWATER WHITE LED POOL LAMP

MCR1900 Media Converter 19-Slot Chassis

Solar Inverter Sunny Boy 5000US, 6000US, 7000US

HP UPS R1500 Generation 3

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

aseries A13B Mini Bullet Camera User Manual

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

AMPSEAL* Automotive Plug Connector and Header Assembly

SmartLogger1000. Quick Installation Guide. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD.

Waterproof Connectors for Outdoor Use

16/32 Channel 1U Rack Mount CCTV Power Supply

Device for Plant Monitoring SUNNY WEBBOX

AM/FM ANTENNA RELOCATION KIT

Subminiature Load Cell Model 8417

Your safety and the safety of others are very important.

How To Set Up An Inverter

39HQ Airovision Air Handling Units

Architect/Contractor Information Package

Wireless LAN Outdoor Bridge Solution

Generator Transfer Switch Model # HTS15-AUTO

Manual Ranging MultiMeter

Operating Manual SUNNY ISLAND 3.0M / 4.4M / 6.0H / 8.0H SUNNY REMOTE CONTROL

User Manual SUNNY VIEW

Structural Holding System

G670 Intermittent Pilot Ignition Controls

Machine needle shut-off nozzle type HP

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

AIR CONDITIONER INSTALLATION MANUAL

Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Elektromotoren und Gerätebau Barleben GmbH

H45 LED - Direct and indirect pendant

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.7

MOUNTING AND OPERATING INSTRUCTIONS

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

Installation and Maintenance Manual for SPANCO Freestanding Modular Bridge Cranes & Monorails

AMF112 Instruction Manual

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Installation Instructions

4RU High Density Shelf Installation Instructions

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Transcription:

Ambient Temperature Sensor TEMPSENSOR-AMBIENT Installation Guide TempsensorAmb-IEN110610 98-0042210 Version 1.0 EN

SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Guide............................... 4 1.1 Area of Validity...................................... 4 1.2 Target Group....................................... 4 1.3 Symbols Used....................................... 4 2 Safety.......................................... 5 2.1 Appropriate usage................................... 5 2.2 Safety Precautions.................................... 5 3 Scope of Supply.................................. 6 4 Assembly........................................ 7 4.1 Selecting the Mounting Location......................... 7 4.2 Assembling the Ambient Temperature Sensor............... 7 5 Electrical Connection.............................. 8 5.1 Connecting Cables to the Ambient Temperature Sensor...... 9 5.2 Connecting the Ambient Temperature Sensor to the Sunny SensorBox................................... 10 6 Decommissioning................................ 12 6.1 Disassembling the Ambient Temperature Sensor........... 12 6.2 Disposing of the Ambient Temperature Sensor............. 12 7 Technical Data.................................. 13 8 Contact........................................ 14 Installation Guide TempsensorAmb-IEN110610 3

Notes on this Guide SMA Solar Technology AG 1 Notes on this Guide This guide describes the installation and commissioning of the Ambient Temperature Sensor. Store this guide where it will be accessible at all times. 1.1 Area of Validity This guide applies to the TEMPSENSOR-AMBIENT upgrade kit. 1.2 Target Group This guide is for electrically skilled persons. 1.3 Symbols Used The following types of safety precautions and general information appear in this document: DANGER! "DANGER" indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING! "WARNING" indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION! "CAUTION" indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE! "NOTICE" indicates a situation that can result in property damage, if not avoided. Information Information provides tips that are valuable for the optimal installation and operation of your product. 4 TempsensorAmb-IEN110610 Installation Guide

SMA Solar Technology AG Safety 2 Safety 2.1 Appropriate usage The TEMPSENSOR-AMBIENT Ambient Temperature Sensor consists of a PT100 measuring resistor that is accommodated in an lp65 plastic enclosure. The TEMPSENSOR-AMBIENT Ambient Temperature Sensor enables measurements in a 4-wire system. The measurement range of the Ambient Temperature Sensor is between 30 C and +80 C. Connect the sensor to Sunny SensorBox for further processing of the ambient data. The Ambient Temperature Sensor is suitable for use only with original SMA accessories or with accessories recommended by SMA Solar Technology AG. Appropriate usage also includes observing all further documentation relating to this device and its components. 2.2 Safety Precautions NOTICE! Destruction of the PV plant by a lightning strike. All devices installed on a rooftop must be integrated into the existing lightning protection of the PV plant. Installation Guide TempsensorAmb-IEN110610 5

Scope of Supply SMA Solar Technology AG 3 Scope of Supply Position Quantity Description A 1 TEMPSENSOR-AMBIENT (Ambient Temperature Sensor) B 2 Screw C 2 Screw anchor 6 TempsensorAmb-IEN110610 Installation Guide

SMA Solar Technology AG Assembly 4 Assembly 4.1 Selecting the Mounting Location The Ambient Temperature Sensor must be assembled with the cable gland pointing downwards in order to prevent water from accumulating on the cable gland. Protect the Ambient Temperature Sensor from severe contamination and spray. See adjacent image for recommended alignment of the Ambient Temperature Sensor. Select an installation location which is in shade throughout the entire day. Make sure that heat cannot accumulate at the installation site. Please observe the maximum cable length of 30 m. 4.2 Assembling the Ambient Temperature Sensor 1. Undo four bolts on the Ambient Temperature Sensor enclosure and remove the lid. 2. Determine the mounting location and mark it. In the process, observe the mounting area (see image). 3. Fasten the Ambient Temperature Sensor enclosure using the screws supplied. The Ambient Temperature Sensor has been assembled. Installation Guide TempsensorAmb-IEN110610 7

Electrical Connection SMA Solar Technology AG 5 Electrical Connection 4-wire system To offset measuring errors that occur due to cable resistance, connect the temperature sensor via a 4-wire system. This type of connection ensures the current feed and voltage measurement are performed by separate pair cables. The length of the cable must not exceed 30 m. Cabling Recommendations NOTICE Damage to Ambient Temperature Sensor due to ingress of fluids Use only cables with a minimum diameter of 4.5 mm 2 to connect the Ambient Temperature Sensor. This prevents the Ambient Temperature Sensor from being damaged by any ingress of fluids (e.g. by rain or snow). The cable length and quality have an effect on the signal quality. To achieve a good quality signal, observe the following instructions regarding cabling: Outdoors For the outdoors, use a cable with the following key properties: Cross-section: at minimum 4 x 0.25 mm 2, at minimum 4 x AWG 24 Outer cable diameter: at minimum 4.5 mm, at maximum 7 mm UV-resistant SMA Solar Technology AG recommends the following cable types: Lappkabel: UNITRONIC S-LifY11Y 4 x 0.34 mm 2 Lappkabel UL-listed: UNITRONIC S-LifY11Y 4 x 0.34 mm 2 Indoors It is permitted to use non-uv-resistant cables outdoors that are protected by a UV-resistant cable channel if the cables comply with aforementioned specifications. SMA Solar Technology AG recommends the following cable types: Lappkabel: Unitronic LiYY 4 x 0.5 mm 2 Lappkabel UL-listed: UNITRONIC LiYY UL/CSA 4 x AWG22/7 Helukabel: TRONIC LiYY 4 x 0.5 mm 2 8 TempsensorAmb-IEN110610 Installation Guide

SMA Solar Technology AG Electrical Connection 5.1 Connecting Cables to the Ambient Temperature Sensor 1. Undo the screws on the Ambient Temperature Sensor enclosure and remove the lid. 2. Remove the cable glands on the Ambient Temperature Sensor. 3. Remove the small interior protection plates. Make sure that the interior seal does not fall out. 4. Screw the cable gland halfway onto the enclosure. 5. Introduce the cables through the cable glands of the Ambient Temperature Sensor. 6. Connect wires to the screw terminals in 4-wire technology, see image on the right. 7. Note the color of the wires: I+ V+ V- I- 8. Fasten the cable gland of the Ambient Temperature Sensor to the Ambient Temperature Sensor enclosure by hand (torque: 0.8 Nm). 9. Connect the plug from the lid of the Ambient Temperature Sensor with the screw terminals, see image on the right. The polarity of the cables is userdefined. 10. Fasten the lid of the Ambient Temperature Sensor to the enclosures using the screws. The cable is connected to the Ambient Temperature Sensor. Installation Guide TempsensorAmb-IEN110610 9

Electrical Connection SMA Solar Technology AG 5.2 Connecting the Ambient Temperature Sensor to the Sunny SensorBox The Ambient Temperature Sensor is connected to the "F6: TmpAmp" terminal of the Sunny SensorBox. Proceed as follows: NOTICE! Damage to the Sunny SensorBox due to ingress of fluids When working outdoors, make sure that no fluids (e.g. rain or snow) enter the open Sunny SensorBox. When inserting and removing the cable through the cable gland, make sure that the grommet fits correctly into the cable gland. NOTICE! Damage to the Sunny SensorBox due to porous rubber seals The rubber seal in the Sunny SensorBox lid becomes porous over the course of time, and will no longer provide a tight seal if the Sunny SensorBox is then opened. If you open the Sunny SensorBox after an operating lifetime of more than 5 years, e.g. for upgrading the device, the rubber seal in the Sunny SensorBox lid must be replaced with a new one. In this event, order a replacement seal prior to maintenance work. 1. Open the lateral flaps of the Sunny SensorBox using the recesses. 2. Undo the screws in the corners of the Sunny SensorBox and open the enclosure lid towards the left. The lid is connected to the lower shell by hooks. 3. Unscrew the cable gland sleeve nut on the bottom center of the Sunny SensorBox and remove the filler-plugs. 4. Route the Ambient Temperature Sensor cable through the sleeve nut and fasten the cable glands of the Sunny SensorBox. 10 TempsensorAmb-IEN110610 Installation Guide

SMA Solar Technology AG Electrical Connection 5. Remove resistance and bridge at the "F6: TmpAmb" terminal in the Sunny SensorBox. 6. Connect the Ambient Temperature Sensor to the "F6: TmpAmb" terminal of the Sunny SensorBox. Please note the indicated wire colors (see page 9). 7. Check that the cable gland grommet is correctly in place. 8. Fasten the lock nut onto the cable gland manually to affix the cable (torque: 0.8 Nm). 9. Lay the cable using suitable fixing material. 10. Place the Sunny SensorBox enclosure lid on the lower enclosure shell. 11. Fasten screws manually (torque: 1 Nm) into the lower enclosure shell. The Ambient Temperature Sensor has been connected to the Sunny SensorBox. Installation Guide TempsensorAmb-IEN110610 11

Decommissioning SMA Solar Technology AG 6 Decommissioning 6.1 Disassembling the Ambient Temperature Sensor 1. Remove the Ambient Temperature Sensor cable from the Sunny SensorBox. 2. Insert resistance (100 Ohm) and the bridge to terminal "F6: TmpAmb" in the Sunny SensorBox. 3. Undo screws on the Ambient Temperature Sensor enclosure and remove the lid. 4. Remove the enclosure from the wall. The Ambient Temperature Sensor has been disassembled. 6.2 Disposing of the Ambient Temperature Sensor At the end of its life cycle, dispose of the Ambient Temperature Sensor in accordance with the applicable disposal regulations for electronic waste at the installation location at the time. Alternatively, return it labeled as "ZUR ENTSORGUNG" ("for disposal") to SMA Solar Technology AG, at your own expense. 12 TempsensorAmb-IEN110610 Installation Guide

SMA Solar Technology AG Technical Data 7 Technical Data General Data Width x height x depth Measuring shunt Mounting location 100 mm x 52 mm x 67 mm PT100 outdoors Environmental Conditions Ambient temperature 30 C +80 C Protection rating IP65 Connection cable *) Maximum cable length 30 m Measurement Range and Tolerances Tolerance at maximum ± 0.7 C (class B) Measurement range 30 C +80 C *) not included in SMA scope of supply. Installation Guide TempsensorAmb-IEN110610 13

Contact SMA Solar Technology AG 8 Contact If you have technical problems concerning our products, contact the SMA Serviceline. We need the following information in order to provide you with the necessary assistance: Ambient temperature sensor model Sunny SensorBox firmware version Sunny WebBox firmware version Measured values of the Ambient Temperature Sensor SMA Solar Technology AG Sonnenallee 1 D-34266 Niestetal www.sma.de SMA Serviceline Inverters: +49 (0)561 9522 1499 Communication: +49 (0)561 9522 2499 Fax: +49 (0)561 9522 4699 E-mail: Serviceline@SMA.de 14 TempsensorAmb-IEN110610 Installation Guide

SMA Solar Technology AG Legal Restrictions The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission. Exclusion of liability The general terms and conditions of delivery of SMA Solar Technology AG shall apply. The content of these documents is continually checked and amended, where necessary. However, discrepancies cannot be excluded. No guarantee is made for the completeness of these documents. The latest version is available online at www.sma.de or from the usual sales channels. Guarantee or liability claims for damages of any kind are excluded if they are caused by one or more of the following: Damages during transportation Improper or inappropriate use of the product Operating the product in an unintended environment Operating the product whilst ignoring relevant, statutory safety regulations in the deployment location Ignoring safety warnings and instructions contained in all documents relevant to the product Operating the product under incorrect safety or protection conditions Altering the product or supplied software without authority The product malfunctions due to operating attached or neighboring devices beyond statutory limit values In case of unforeseen calamity or force majeure The use of supplied software produced by SMA Solar Technology AG is subject to the following conditions: SMA Solar Technology AG rejects any liability for direct or indirect damages arising from the use of software developed by SMA Solar Technology AG. This also applies to the provision or non-provision of support activities. Supplied software not developed by SMA Solar Technology AG is subject to the respective licensing and liability agreements of the manufacturer. SMA Factory Warranty The current guarantee conditions come enclosed with your device. These are also available online at www.sma.de and can be downloaded or are available on paper from the usual sales channels if required. Trademarks All trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by SMA Solar Technology AG is under license. SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel. +49 561 9522-0 Fax +49 561 9522-100 www.sma.de E-Mail: info@sma.de 2004 to 2011 SMA Solar Technology AG. All rights reserved Installation Guide TempsensorAmb-IEN110610 15