SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals



Similar documents
IEI 232e Standalone TM Keypad Installation/ Programming Manual

FEATURES AND PROGRAMMING GUIDE COMMANDANDCONTROLSERIES

Advantium 2 Plus Alarm

VARIO PROX CARD READER INSTALLATION MANUAL

Secure Keypads for access control

Model 201 Wiegand Touchpad Reader Installation Guide

PROXIMITY CARD READERS C-10, C-20, C60, C70

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Single Station Remote Alarm

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

AR-721U/721K/661U User s Guide

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

e-ask electronic Access Security Keyless-entry

Digital Keypad Use s Manual

CHAPTER 1. GETTING STARTED... 1

Model SRMD Setra Remote Monitoring Display

GV- RK1352 Card Reader

P10 - Standalone Access Controller and Reader

Installation Instructions

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

INSTALLATION GUIDE. APPLICATION LENGTH MODEL YR PART # Bestop PART #

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION INSTRUCTIONS

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

VK-250 WARRANTY REGISTRATION FORM

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

Digital Fingerprint safe

User Manual. Before installation and use, please read the user manual carefully.

Installation and Operation Guide PD4600 Series Converter Replacement

Owner s Manual & Safety Instructions

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

LCD5500Z / PKP-LCD v3.x Installation Instructions

Auto Dialer. Manual E-921APQ E-921GPQ

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

Trilogy DL2700 Programming Instructions OI209A 2/04

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

TAC1 Telephone Entry System Installation and Programming Manual

CRYPTOPAY QUICK START GUIDE

Installation and Operating Manual

INSTALLER S & OWNER S MANUAL

BroadBand PowerShield. User Manual

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

INSTALLATION AND OPERATIONS GUIDE. Qt SOUND MASKING PAGING MUSIC

User Manual. Humidity-Temperature Chart Recorder. Model RH520

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Automatic Phone-Out Home Monitoring Systems

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

9452/9453 Installation and User Guide

ADDING and/or DELETING PIN NUMBERS (Plus other simple programming commands) in My DK-16 or DK-26 DIGITAL KEYPAD

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

12 Volt 30 Amp Digital Solar Charge Controller

8-Ohm Ceiling Speakers For Music and Home Theater

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

CA-125 Owner's Manual

25 Code GTO Digital Keypad

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

HotLok Pass Through Blanking Panel

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

T-Extender E-Extender

INSTALLATION GUIDE. FCC ID NOTICE

TerraWave Solutions MIMO Site Survey Battery Pack (Part # TW-SSBP-007) Instructions For Use

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

for DNE-K07 Reference and Installation Manual

Alliance System Ordering Guide

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

3M Wrist Strap and Footwear Tester 740. User s Guide

1 x TS0861 Magnetic Swipe Card Reader. 1 x Installation Guide (this document).

Control Box Wiring For PRSstandard Tool

TAC2C & TAC2D TAC1 RETROFIT KIT FOR CROWN JEWEL & DOORKING 1812 SYSTEMS

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Adaptability to Enhanced Security

CONTROL SWITCHER User s Manual (Preliminary)

VEHICLE SECURITY SYSTEM G25/G20

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

InHome Water Leak Detection Package

Adaptability to Enhanced Security

Dome Security Camera with IR night vision

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Leak Detection System

ROTOR LOADER OWNER S MANUAL

Crow Limited Warranty. Print Version 017

Quick Start Guide. Rev. 1.0

Comfort Control Relay Panel (CCRP)

How To Program An Autodialer

Applied Electronics. Commercial Dimming System UPDATE NOTICE

SingleNet Single Cable Control System

Residential Gateway (RG) Battery Backup REV B

Installation Instructions

Operation and Installation Manual

Transcription:

SSW-iLM Keypad Note: This product is designed to be installed and serviced by security and lock industry professionals Specifications Case dimensions: 6 1/2 L x 1 3/4 W x 1 1/8 D Electrical: 5-12VDC Only Current draw: 5VDC: 28mA typical; 60mA max 12VDC: 27mA typical; 77mA max Features: Vandal Resistant Case Sealed For Indoor or Outdoor Applications LED s For Relay Status Indication Bell Output Surface mount Illuminated hardened keys Rated at greater than one million key cycles Bell relay: (form A) 1amp @ 30VDC 500ma @ 125VAC Environmental: -20º F to 130º F Applications: Low-Medium/Heavy Traffic Use Rough Service Environments Mullion Frame Mounting For use with the following: Most Wiegand electronic access control panels. Wire Harness Configuration Any IEI Secured Series door control module (DCM). IEI Stand Alone Access Control. Functionality: Combining elegant looks and mullion mount design in a rugged vandal resistant case, IEI s new Door-Gard Series Mullion keypad can be utilized for most any application. Designed to perform in medium-high traffic and rough duty environments, the IEI Door-Gard Series Mullion has hardened backlit keys. Encapsulated electronics makes the Door-Gard Series Mullion keypad suitable for indoor or outdoor installations. The keypad is activated by entering any 1-6 digit programmed code followed by the star * key. IEI offers the Door-Gard Series Mullion keypad as model SSW-iLM, a keypad only version for use with an IEI controller or in Wiegand applications. Packing List: (SSW-iLM) IEI Door-Gard Mullion keypad (1) Eight conductor wire harness (1) 8 x 1 1/4 Panhead Machine screws (2) 8 x 1 1/4 Panhead wood/sheet metal screws (2) 5/64 Allen wrench (1) Anti Oxidant Grease (1) Instruction manual w/template (1) Wire Requirements: Maximum distance with stranded shielded : 18 AWG - 1000 20 AWG - 500 22 AWG - 250 1 of 8 1 3 5 7 Pin Wire color Signal name 1 Red V in (+) 2 Black V in (-) 3 White/Black Data 0 4 White/Yellow Data 1 5 Blue LED 1 6 Brown LED 2 (not used) 7 White Bell Relay Contact (A) 8 White Bell Relay Contact (B) 2 4 6 8

To Install: Step 1: Step 2: Step 3: Drill through the back plate using a 11/64 bit. Use the template provided to accurately mark the holes needed for mounting. Drill the mounting holes with a 9/64 drill bit, also drill the hole for the wire run (size determined by number of wires used). Be sure to strip back the insulator from the wire run, and tape the shield to the jacket. Connect the eight conductor harness supplied with the SSW-iLM keypad to the five conductor wire run for Wiegand connection or four conductor for an IEI Hub DCM as shown in the diagrams below. Apply Anti Oxidant grease (supplied) to the keypad connector. Place the Door-Gard Series Keypad on the wall or back box, and secure with the provided screws. DO NOT OVER TIGHTEN. (Damage may occur) Wiring the Door-Gard Mullion Keypad to an IEI Hub DCM Electrical Tape Electrical Tape The following connections are to be made at the Front End connection on the Hub DCM. Keypad 48 WHITE\YELLOW BLACK/WHITE RED BLACK Insulator Wiring the SSW-iLM to an IEI Hub DCM requires a four conductor, stranded and shielded cable to be wired between the two units. Maximum lengths are as follows: 22 AWG stranded : 250 feet 20 AWG stranded : 500 feet 18 AWG stranded : 1000 feet The drain wire from the wire run must be attached to ground. Ground is the FT1 tab loacted on the HubMax/Minimax backplane. At the mullion keypad, the drain wire and foil shield should be cut back with the insulator and taped with electrical tape. The eight conductor harness connects into the eight pin connector on the SSW-iLM keypad. You may use two keypads to one Hub DCM for in/out operation. Parallel both readers on the same wire run from the Hub DCM. Note: If two keypads are desired the extra keypad # is SSW-iLM. Drain Wire * Brown & Blue wires are not used when using an IEI controller WHITE\YELLOW WHITE\BLACK RED BLACK Wiring the Door-Gard Series Mullion Keypad to a Wiegand Panel Hub DMC Electrical Tape Electrical Tape Brown wire not used 48 Blue Keypad WHITE/YELLOW BLACK/WHITE BLACK RED Insulator Drain Wire LED 1 DATA 1 DATA 0 - GND + 5-12 VDC 2 of 8

Wiring the bell output to a speaker With the SSW-iLM you can use the bell button to trigger an external device such as a door bell or like devices that require a momentary closer to operate. This is easily accomplished by either using the dry contact provided or you can run up to 24VDC or 120VAC through one leg of the bell output (A) and connecting the other leg (B) to the power in on your device. Then connect the negative connection on your device to the negative on your power supply (as shown below). SSW-iLM wire harness To IEI controller Positive Negative Speaker To separate power supply System Defaults: The Door-Gard Keypad is designed for easy installation in a minimum amount of time. The following default values have been factory programmed. Front End Designation HFE (Hub Front End) Mullion Keypad Program Code 6789 Audible Key Press Feedback On Visual Key Press Feedback On Log Event Recording IN Keypad illumination Enabled Keypad Dimming Enabled Door bell select Enabled Door bell duration Continuous To Exit program mode (until the yellow led stops blinking) * Wiegand Defaults Red LED Enabled Interpulse spacing 640 Usecs Red LED State Low Pulse width 160 Usecs Green LED Enabled Group ID 0 Green LED State High Side ID 0 Format 26 Bit If it is necessary to change any of these defaults, please refer to the Programming Options Chart after you have familiarized yourself with the programming section. Self Test: While the unit is powered up, enter the following on the Mullion keypad: 7890#123456 *. If all 12 key presses have been verified, the keypad will enter self test mode. The LED s will alternate three times and the sounder will beep three times followed by a flickering yellow LED. Press any key to return to normal operation. 3 of 8

Replacing the IEI KP500wm mullion keypad (discontinued) with an IEI SSWiLM POS NEG DI DO Hub DCM KP500WM SSW-iLM RED POS RED BLACK NEG BLACK WHITE/YELLOW DO D1 (DATA OUT) (WHITE/YELLOW) WHITE/BLACK D1 DO (DATA IN) (WHITE/BLACK) 4 of 8

Programming The Door-Gard Mullion Keypad All programming is controlled by a unique Master Programming Code. Components Requiring Programming: Door-Gard Mullion Keypad (default SSW-ILw keypad program code- 6789): IEI or Wiegand format, Door-Gard Keypad Programming Code. IEI Stand Alone Controller or IEI Hub DCM (default Master Code 1234): All PIN number additions, deletions, access to control functions. Wiegand Panel/Controller: Program as if card number (up to 6 digits in length) into the Vendors panel via the Vendors software. Door-Gard Mullion Program Options Chart To Enter Door-Gard Mullion Keypad program mode: 099 # program code * (Default program code 6789) The keypads yellow LED will flash twice rapidly indicating that you are in program mode. Change Program Code Press 90 # 0 # 0 # new code * repeat code * Visual Key-press feedback on Press 91 # 0 # 1 # ** Visual Key-press feedback off Press 91 # 0 # 0 # ** Audible Key-press feedback on Press 91 # 1 # 1 # ** Audible key-press feedback off Press 91 # 1 # 0 # ** Output Selection - Wiegand Press 91 # 3 # 1 # ** Output Selection IEI Secured Series Press 91 # 3 # 0 # ** Secured Series Recording status OUT Press 91 # 4 # 1 # ** Secured Series Recording Status IN Press 91 # 4 # 0 # ** Wiegand Red led enable Press 91 # 5 # 1 # ** Wiegand Red led disable Press 91 # 5 # 0 # ** Wiegand Red led state High Press 91 # 6 # 1 # ** Wiegand Red led state Low Press 91 # 6 # 0 # ** Wiegand Green led enable Press 91 # 7 # 1 # ** Wiegand Green led disable Press 91 # 7 # 0 # ** Wiegand Green led state High Press 91 # 8 # 1 # ** Wiegand Green led state Low Press 91 # 8 # 0 # ** Enable keypad illumination Press 91 # 11 # 1 # * * Disable keypad illumination Press 91 # 11 # 0 # * * Enable keypad dimming Press 91 # 12 # 1 # * * Disable keypad dimming Press 91 # 12 # 0 # * * Default Mullion keypad to IEI Controller mode 96 # 0 # 0 # ** Default Mullion keypad to 26 bit Wiegand mode 96 # 1 # 1 # ** Programming the Bell output To enable the door bell feature Press 91 # 13 # 1 # * * To disable the door bell feature Press 91 # 13 # 0 # * * To set door bell duration Press 92 # 4 # 01-99 # **(time must be set in a two digit format) To set door bell to continuous Press 90 # 4 # 0 # ** 5 of 8

If there is a need to change your Wiegand format from 26 Bit, use the chart below 92 # Option # Value # * * 1 -Wiegand Format 1 thru 8 (defaults to 1 = 26 bit) -see below 2 -Inter-pulse spacing 1 thru (defaults to 32 = 640usecs 3 -Pulse Width 1 thru (defaults to 8 = 160 usecs) 93 # ID Type # ID Value # * * 0 -Site ID 1 -Group ID 0 thru 999 (defaults to 0) 0 thru 999 (defaults to 0) Wiegand Formats Format 1 2 3 4 5 6 7 8 Frame Size 26 bits 28 bits 29 bits 30 bits 31 bits 32 bits 36 bits 29 bit Largest PIN Value Largest Site Value Largest Group Value 65535 32767 524287 65535 15 65535 31 8191 2047 63 1048575 524287 6 of 8

System Defaulting the SSW-ilm Mullion via wiring If the four data wires are shorted in one of the two configurations shown below on power up, the option will be set. Remove power after you hear the 3 beeps then reconnect the data lines to their proper working configuration. Defaults SSW-iLM and sets it in Hub Front End mode Red Black Wht/Blk Wht/Yel Blue Brown +12VDC - GND (DAO) (DA1) (LED1) (Not Used) Defaults SSW-iLM and sets it in Wiegand 26 bit mode Red +12VDC Black - GND Wht/Blk (DAO) Wht/Yel (DA1) Blue (LED 1) Brown (Not Used) If the local program code is lost or forgotten, power down the system, connect the wire harness as shown below then power the system up. Change your local program code then power down the system and restore the wire harness to its original configuration and power back up. Red Black Wht/Blk Wht/Yel Blue Brown - +12VDC - GND - No connection If this product does not seem to operate properly, please call our Technical Support Department toll free at 1-800-343-9502 (781-821-5566). We understand your time is valuable, and we know that calling our Technical Support Department will ensure that you ll make the most profit possible with your IEI product. Thank you for your purchase. We appreciate your business. International Electronics,Inc.(IEI) warrants its products to be free from defects in material and workmanship, when they have been installed in accordance with the manufacturer s instructions, and have not been modified or tampered with. IEI does not assume any responsibility for damage or injury to person or property due to improper care, storage handling, abuse, misuse, normal wear and tear, or an act of God. IEI s sole responsibility is limited to the repair (at IEI s option)or the replacement of the defective product or part when sent to IEI s facility (freight and insurance charges prepaid), after obtaining IEI s Return Merchandise Authorization. IEI will not be liable to the purchaser or any one else for incidental or consequential damages arising from any defect in, or malfunction of, its products. This warranty shall expire two years after shipping date. Except as stated above, IEI makes no warranties, either express or implied, as to any matter whatsoever, including, without limitation to, the condition of its products, their merchantability, or fitness for any particular. 427 TURNPIKE STREET, CANTON, MA 02021 U.S.A. 800-343-9502, 781-821-5566 781-821-4443 (FAX) FAX ON DEMAND 781-821-0734 (FROM YOUR FAX MACHINE) Visit our website for Access Control & Glassbreak information, New Products, Specifications, Applications, Seminars, and Partners @ www.ieib.com 7 of 8

Mounting Template for ilm 1 7/16 6 1/4 3 3/8 1 7/16 Diameter of the mounting holes -11/64 Diameter of the wiring hole -7/8 This product is designed as a surface mountable product. The access hole for the wires is determined by the size of the connector. You must drill a 7/8 hole to allow the connector to fit into the mounting surface so the keypad will fit flat on the surface. 8 of 8