REA 10_ 1MRS 750929-MBG

Similar documents
Arc Protection Relay REA 10_. Product Guide

REA 101 Arc protection relay. Operator s manual

Voltage Regulator SPAU 341 C. Product Guide

Arc Protection Relay REA 101. Operator s Manual

Capacitor Protection Relay SPAJ 160 C. Product Guide

Disturbance Recoder SPCR 8C27. Product Guide

Waveguide Access Point WGA631. Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide

Trip circuit supervision relay. Type RXTCS

Current and voltage measuring relays

Combined overcurrent & earth-fault relay. Type SPAJ 140 C

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Three-phase monitoring relay CM-PFE

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

RM4TG20 three-phase network control relay RM4-T - range V

Analog signal converters CC-E I/I Current / current isolators

80 Series - Modular timers 16 A. Features

38 Series - Relay interface modules A

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Arc Terminator Active Arc-Resistant Switchgear

Circulating Current Relay. Type IRXm

MasterINTERFACE 39 Series - Relay interface modules

38 Series - Relay interface modules A

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

80 Series - Modular timers 16 A. Features

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Catalog. Arc Guard System TM TVOC-2

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

MasterINTERFACE 39 Series - Relay interface modules

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Electronic overload relay EF19 and EF45

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Thermistor motor protection

Electronic overload relay EF65, EF96 and EF146

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Power Meter Series 700

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Safety technique. Emergency stop module BO 5988 safemaster

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Telephone- and leased line modem for industrial applications TD-36

15 Series - Electronic step relay and dimmer. Features SERIE

Drayton Digistat +2RF/+3RF

UFES Active protection for switchgear

Auxiliary Relay. Type P8n, PQ8n, PN8n

SINEAX U553 Transducer for AC Voltage

49 Series - Relay interface modules A. Features

MHCO MHCO-RI. Transmitter The Transmitter, connected to the system, acquires the inputs and througth a fiber optic transmits it to the receiver.

Permissible ambient temperature Operation Storage, transport

STRATO LED Drivers 70W, Single output

ABB i-bus KNX SA/S Switch Actuators Product Manual

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850

Rack mounted telephone- and leased line modem for industrial applications

Relion 605 series. Feeder protection and control / Feeder protection REF601 / REJ601 Product Guide

T Substation Maintenance and Commissioning Test Equipment

Digital Pressure Measuring Instrument MDR480

ST Series POWER SUPPLIES USER INSTRUCTIONS

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

48 SERIES Relay interface modules 10 A

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Control Devices Catalogue. Control Devices. Preferred and Standard Products

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Quick Connect. quick - simple - efficient.

Features. Picture. Specifications

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pluggable interface relays CR-P Pcb relays

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Manual motor starter MS116

Medium voltage arc flash eliminator units VAM 3ED,

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Pilot-wire differential relay for lines with two or more terminals

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Relés e Contatores de Estado Sólido SIRIUS

FREJA 300 Relay Testing System

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Transcription:

Arc protection relay REA 10_ Issued: May 1999 Status: Updated Version: C/05.07.2002 Data subject to change without notice Features Loop-type sensor fibre, radial sensor fibre or lens-type sensor for arc detection Two high-speed semiconductor outputs for tripping Tripping from light only or secured with fast, adjustable three-phase overcurrent condition Total operate time <2.5 ms Wide area automatic or manual backlight compensation Two RJ45 ports for chaining the extension units Two opto-connectors for fast ON/OFF signal transfer between central units Circuit-breaker failure protection, i.e. delayed output for higher-level circuit breaker Self-supervision unit for monitoring the sensor fibre, operating voltages and cabling between central units and extension units Application Consequences of an arcing short circuit fault within a low/medium voltage switchgear can be very serious. An arc can destroy costly equipment, and cause prolonged and expensive downtime. Furthermore, an arc can cause serious injuries to personnel. Sources of arcing can be e.g. failure of insulation, mal-operation of a device, improper bus or cable joints, overvoltage, corrosion, pollution, moisture, ferro-resonance (instrument transformers) and even ageing under electrical stress. Most of these could be prevented by sufficient maintenance. But in spite of all precautions, human errors by personnel can also lead to arc faults. Time is critical when it comes to detecting and minimising the effects of an arc. An arc fault lasting 500 ms may cause severe damage to the installation. If the arc lasts less than 100 ms the damage is often smaller, but if the arc is eliminated in less than 35 ms the damage is almost unnoticed. Normally applied bus bar protection relaying arrangements may be too slow to ensure safe fault clearance times at arc faults. E.g. operation time of the overcurrent relay controlling the incoming CB may have to be delayed hundreds of milliseconds for selectivity reasons. This delay can be avoided using REA 10_ arc protection system: Total fault clearance time can be reduced to max 2.5 ms plus circuit breaker s action time. Furthermore, autoreclosures at cable compartment faults can be eliminated with arc protection. The arc protection relay REA 101 and the extension units REA 103, REA 105 and REA 107 are designed to be used for the protection of medium and low-voltage air-insulated switchgear. The central unit type REA 101 operates independently or together with the extension units REA 103, REA 105 and REA 107. These extension units allow the number of sensor fibres and/or lens sensors to be increased, thus extending the area to be pro- 1

tected. In an arc situation, the fault place is quickly localized by inspecting the area covered by the sensor that detected the arc. The design of the extension units REA 103 and REA 105 is nearly the same. The main difference between the units is that the REA 105 is provided with two fast trip outputs capable of opening, for example, the bus coupler or both circuit breakers of a duplex feeder. Thus selective tripping is achieved. The REA 107 is also used for the extension of the protection area. It has inputs for eight lens-type sensors. The arc protection relay REA 101 is provided with two output ports, to each of which a maximum of five extension units can be chained. Design Arc protection relay REA 101 Current indication unit The three phase currents are measured via transformers. An overcurrent signal is activated once the current on one phase exceeds the reference level. The SG1/1-4 switches are used for selecting the reference level. Available current level settings are 0.5, 1.0, 1.5, 2.5, 3.0, 5.0 and 6.0 times the rated current (I n = 1.0 A or 5.0 A). Light detection unit The switch SG1/6 is used for activating the sensor. Automatic or manual backlight compensation reference level is selected with the switch SG1/5. The light captured by the sensor is amplified and compared to pre-selected reference level. Once the light exceeds the set reference level, a light signal is activated. When an automatic reference level has been selected, the unit forms the reference level based on the backlight intensity measured by the sensor. When a manual reference level has been selected, the unit forms the reference level based on the value set by the potentiometer (Light Ref. Level Adj.) on the front panel. The condition of the sensor fibre is monitored by sending a test pulse through the fibre. Unless the test pulse is received at regular intervals at the other end of the loop, the sensor fault LED (Sensor Fault) and the selfsupervision LED (IRF) are activated and the IRF relay resets. If the sensor-monitoring feature is not needed, it can be deactivated by means of switch SG3/4. Then no test pulse will be sent and a radial, i.e. terminating sensor fibre can be used. Trip output The trip output is provided with two galvanically isolated, high-speed IGBT semiconductor outputs, HSO1 and HSO2, and a relay output TRIP3. These outputs can be used in DC and AC circuits. The control signal of the outputs is activated if the overcurrent signal and the light signal, but not the operating voltage fault signal, are active at the same time. If tripping is to be activated by an arc alone, the overcurrent signal can be set to be constantly active by means of the key switch Trip Condition located on the front panel. When a trip signal is delivered, the trip outputs are locked in the activated state. The Reset pushbutton on the front panel or a reset signal applied to the RESET input can be used to reset the outputs. Ports A and B for the connection of extension units Ports A and B are activated using the switches SG1/7-8. The extension units connect to the ports via connection cables. The extension unit receives its operating voltages and operation signals over the port. The ports are protected against short circuit and cable breaks. If the connection cable from a port breaks, the concerned chain is disconnected and the fault LED (Port A Fault or Port B Fault) of the port and the IRF indicator on the central unit activated, and the IRF relay resets. A maximum of 5 extension units can be connected to one port. If an extension unit included in the chain connected to the port is damaged, then the fault LED of the port starts flashing, the IRF indicator is lit and the IRF relay resets. Communication REA101/REA101 (optolink) The REA 101 relay contains two communication links: Optolink 1 and Optolink 2. The SG2/1-8 switches are used to select the links to be used and the messages to be communicated between them. Each link can be programmed either as a transmitter or as a receiver. The purpose of the communication link is to communicate ON/OFF type messages between the central units, over the signal transfer fibre. The message can be light, overcurrent or trip signals. Only one type of mes- 2

sage per optolink is allowed to be transmitted between the central units. The data to be communicated depends on the system design. To monitor the connection, a test pulse is sent through the signal transfer fibre at regular intervals. Should the test pulse not be received at the specified time, the optolink fault LED (Optolink 1 Fault, Optolink 2 Fault) and the IRF indicator of the central unit will be lit, and the IRF relay resets. Circuit-breaker failure protection (CBFP) The circuit-breaker failure protection has been implemented by delaying either the HSO2 output or the TRIP3 output, or when required, both outputs. The switches SG3/1-3 are used for selecting the desired alternative. If both outputs are used, it should be noted that the delay time is the same, but the pickup time of the relay (5 15 ms) has been added to the TRIP3 relay. The selected delay time, i.e. 100 ms or 150 ms, starts running once the HSO1 is activated. Delayed tripping does not take place if the overcurrent signal disappears before the specified time delay elapses. When the circuit-breaker failure protection is out of use, all the trip outputs operate in parallel. Self-supervision unit (IRF) In addition to that mentioned above, the selfsupervision unit monitors the operating voltage of the relay. Should a fault be detected in the operating voltages, the self-supervision unit will prevent the relay from operating. In addition, the IRF indicator is lit and the IRF relay resets. Extension unit REA 103 The REA 103 is an extension unit designed to be used together with the arc protection relay REA 101. The function of the unit is to detect light and to provide the REA 101 relay with information about this. The use of the extension unit allows the protection area to be extended and the object to be divided into smaller areas. The REA 103 arc protection unit has the following features: two sensor fibres for arc detection, loop or radial arrangement two signal relays for each sensor fibre relays activated by light detected by the sensor fibre two RJ45 ports for the connection of REA 101 relay and extension units self-supervision unit monitoring operating voltages and sensor fibre loops Extension unit REA 105 The REA 105 is an extension unit designed to be used together with the arc protection relay REA 101. The function of the unit is to detect light and to carry out tripping, if the REA 101 relay provides an overcurrent signal at the same time, or delivers a trip command. The use of the extension unit allows the protection area to be extended and the protected object to be divided into smaller areas. Thus a more selective system is obtained. The REA 105 arc extension unit has the following features: loop-type or radial sensor fibre for arc protection two high-speed semiconductor outputs for tripping signal relay activated by light detected by the sensor fibre three RJ45 ports for the connection of REA 101 and extension units; additional RJ45 port allows REA 105 to be used as a link between two REA 101 relays circuit-breaker failure protection. Delayed light signal to REA 101, which opens the higher-level circuit breaker self-supervision unit monitoring operating voltages and the sensor fibre loop Extension unit REA 107 The REA 107 is an extension unit designed to be used together with the arc protection relay REA 101. The function of the unit is to detect light and to provide the REA 101 relay with information about this. The use of the extension unit allows the protection area to be extended and the object to be divided into smaller areas. The REA 107 arc extension unit has the following features: eight lens-type sensors for arc detection two signal relays two RJ45 ports for the connection to the host REA 101 or other extension units self-supervision of operating voltages LED indicators for each sensor 3

Technical data 7DEOH&XUUHQWLQSXW Rated current Continuous load current Momentary current for 1 s Dynamic current withstand, half-wave value Input impedance Rated frequency 7DEOH2XWSXWV 1 A / 5 A 4 A / 20 A 100 A / 500 A 250 A / 1250 A <100 mω / <20 mω 50 or 60 Hz Trip contacts HSO1 and HSO2 Max system voltage 250 V dc/ac Continuous carry 1.5 A Continuous carry (REA 105) 1.0 A Make and carry for 0.5 s 30 A Make and carry for 3 s 15 A Breaking capacity for dc, when the control circuit time constant L/R < 40 ms, at 48/110/220 V dc 5 A / 3 A / 1 A Trip contact TRIP3 Max system voltage 250 V dc/ac Continuous carry 5 A Make and carry for 0.5 s 30 A Make and carry for 3 s 15 A Breaking capacity for dc, when the control circuit time constant L/R < 40 ms, at 48/110/220 V dc 5 A / 3 A / 1 A Signal contacts IRF Max system voltage 250 V dc/ac Continuous carry 5 A Make and carry for 0.5 s 10 A Make and carry for 3 s 8 A Breaking capacity for dc, when the control circuit time constant L/R < 40 ms, at 48/110/220 V dc 1 A / 0.25 A / 0.15 A 7DEOH5(6(7LQSXW Control voltages Control current Minimum pulse length Rated voltages and operating ranges not active, when control voltage U n = 24/48/60/110/220 V dc 18...265 V dc U n = 110/120/220/240 V ac 18...265 V ac <9 V dc, 6 V ac 1.5 20 ma >0.6 s 7DEOH&LUFXLWEUHDNHUIDLOXUHSURWHFWLRQ&%)3 Selectable operate time delays 150 ms / 100 ms Operate time accuracy HSO2 ±5% of setting value TRIP3 ±5% of setting value +5 15 ms 7DEOH3RZHUVXSSO\ Relay type 1MRS090416-AAA Relay type 1MRS090416-CAA U n = 110/120/220/240 V ac 85 110% of U n ac U n = 110/125/220 V dc 80 120% of U n dc U n = 24/48/60 V dc 80 120% of U n dc 4

7DEOH3RZHUFRQVXPSWLRQ REA 101 REA 103 (operating voltage over the port of REA 101) REA 105 (operating voltage over the port of REA 101) REA 107 (operating voltage over the port of REA 101) Power consumption of relay under quiescent/operating conditions Max. port output power Max. number of extension units/port Max. power consumption with 10 extension units connected Power consumption of relay under quiescent/operating conditions Power consumption of relay under quiescent/operating conditions Power consumption of relay under quiescent/operating conditions ~9 W / ~12 W ~19 W 5 <50 W ~1.6 W / ~3.3 W ~2.7 W / ~3.7 W ~1.7 W / ~2.7 W 7DEOH6HQVRUILEUH Maximum length without splices or one splice Maximum length with two splices Maximum length with three splices Service temperature range Smallest permissible bending radius 60 m 50 m 40 m -35 +80 C 50 mm 7DEOH&RQQHFWLRQFDEOH Total length of the connection chain 40 m 7DEOH2SWROLQNFRPPXQLFDWLRQ Max. length of signal transfer plastic fibre Max. length of signal transfer glass fibre 40 m 2000 m 7DEOH6HWWLQJUDQJH Current setting steps I n x 0.5, 1.0, 1.5, 2.5, 3.0, 5.0, 6.0 Operation accuracy ±5% of the setting value 7DEOH7RWDORSHUDWHWLPH HSO1 and HSO2 TRIP3 2.5 ms <15 ms 7DEOH(QYLURQPHQWDOWHVWV Specified service temperature range -10 +55 C Transport and storage temperature range -40 +70 C Operation in dry heat conditions Acc. to IEC 60068-2-2 (BS 2011:Part 2.1 B) Operation in dry cold conditions Acc. to IEC 60068-2-1 (BS 2011:Part 2.1 A) Damp heat test cyclic Acc. to IEC 60068-2-30 (BS 2011:Part 2.1 Db) r.h. >95%, t=20 55 C Storage temperature test Acc. to IEC 60068-2-48 5

Technical data (cont d) 7DEOH(QFDSVXODWLRQ REA 101 Degree of protection, IEC 60529 IP 20 Weight about 4.6 kg REA 103 Degree of protection, IEC 60529 IP 20 Weight about 1.1 kg REA 105 Degree of protection, IEC 60529 IP 20 Weight about 1.1 kg REA 107 Degree of protection, IEC 60529 IP 20 Weight about 1.0 kg 7DEOH,QVXODWLRQWHVWV Dielectric tests acc. to IEC 60255-5 Impulse voltage test acc. to IEC 60255-5 Insulation resistance acc. to IEC 60255-5 2 kv, 50 Hz, 1 min. 5 kv, 1.2/50 µs, 0.5 J >100 MΩ, 500 V dc 7DEOH0HFKDQLFDOWHVWV Vibration tests (sinusoidal) acc. to IEC 60255-21-1 class 1 Shock and bump test acc. to IEC 60255-21-2 class 1 Seismic test acc. to IEC 60255-21-3 class 2 7DEOH(OHFWURPDJQHWLFFRPSDWLELOLW\ 1 MHz burst disturbance test, common mode acc. to IEC 60255-22-1, class III differential mode Electrostatic discharge test, contact discharge acc. to IEC 61000-4-2, class III air discharge Radio-frequency electromagnetic frequency f field disturbance test acc. to field strength E IEC 61000-4-3 Radio frequency disturbance test, (conducted, common mode) acc. to IEC 61000-4-6 Fast transient disturbance tests acc. to IEC 255-22-4 and IEC 61000-4-4 Surge immunity test acc. to common mode IEC 61000-4-5: aux. voltage input, differential mode current inputs, trip outputs (REA 101) Surge immunity test acc. to IEC 61000-4-5: trip outputs (REA 105) Surge immunity test acc. to IEC 61000-4-5: signal contacts (IRF), RESET input (REA 101) Surge immunity test acc. to IEC 61000-4-5: signal output contacts (REA 103, REA 105 and REA 107) Electromagnetic emissions tests acc. to EN 55011 and EN 50081-2 common mode differential mode common mode differential mode common mode differential mode conducted RF emission (mains terminal), REA 101 radiated RF emission 2.5 kv 1 kv 6 kv 8 kv 80 1000 MHz 10 V/m (rms) 10 V, 150 khz 80 MHz 4 kv 4 kv 2 kv 4 kv 2 kv 2 kv 1 kv 2 kv 1 kv EN 55011, class A EN 55011, class A 7DEOH&(DSSURYDO Complies with the EMC directive 89/336/EEC and the LV directive 73/23/EEC 6

Block diagram X1 1 2 3 4 5 6 7 8 9 HSO1 HSO2 TRIP3 IRF Uaux RESET X3 1 2 34 5 6 8 9 10 X2 1 2 9 10 SG1/1 SG1/2 SG1/3 SG1/4 Current setting + ~ - X6 SENSOR X7 X4 PORT A X5 PORT B SG1/6 SG1/5 Light detection and testing SG1/7 Cable connection block SG1/8 Cable connection block SG3/4 I> I> light light light I> trip I> SG3/1 SG3/2 SG3/3 & Circuitbreaker failure protection trip I> light SG2/2 SG2/3 SG2/4 SG2/6 SG2/7 SG2/8 SG2/1 master - master communication SG2/5 master - master communication X8 X9 Optolink 1 X10 Optolink 2 X11 mlohko Fig. 1 Block diagram of REA 101 X1 8 9 10 4 5 6 IN sensor 1 SG1/ 3 Light detection and testing SG1/ 5 Light1 Light2 OUT SG1/ 4 SG1/ 2 IN sensor 2 Light detection and testing OUT SG1/ 1 PORT IN PORT OUT X2 X3 Cable connection block light Power lohko3 Fig. 2 Block diagram of REA 103 7

HSO2 HSO1 X4 1 2 3 6 7 9 10 IN sensor 1 OUT SG1/ 4 SG1/ 3 Light detection and testing SG1/ 8 light SG1/ 7 SG1/ 6 Circuitbreaker failure protection SG1/ 1 SG1/ 5 & ³1 PORT IN 1 PORT OUT 1 X1 X2 Cable connection block SG1/ 2 trip I> ³1 Power PORT IN 2 X3 Cable connection block I> trip ³1 loh5a Fig. 3 Block diagram of REA 105 Fig. 4 Block diagram of REA 107 8

135,2±1 Arc protection relay REA 10_ Dimensions Dimension drawings 130,8 ABB 265,9 255,8 148,8 190 204,1 235 245,1 Without protective cover With protective cover dim1_3 482.6 Fig. 5 Dimensions of REA 101 Mounting alternatives >20 254,3±1 ABB ~15 Measure D: 218.5 mm without protective cover 228,6 mm with protective cover 16,5 D 4-10 flush1_3 Measure D: 128,5 mm without protective cover 138.6 mm with protectivecover 106,5 D semifl1_3 Fig. 6 Flush mounting and semi-flush mounting of REA 101 M6x12 TORX A M4x6 TORX Wall C M5x8 TORX B wallmoun. Fig. 7 Surface mounting of REA 101 9

ø 5.0 170.3 203.3 160.5 182.6 Fig. 8 Dimensions of REA 103 dim103 44.6 ø 5.0 170.3 203.3 160.5 182.6 Fig. 9 Dimensions of REA 105 dim105 49.6 Fig. 10 Dimensions of REA 107 10

Ordering :KHQRUGHULQJSOHDVHVSHFLI\ Ordering information Ordering example 1. Type designation and quantity REA 101, 5 pieces 2. Order number 1MRS 090416-AAA 3. Auxiliary voltage U aux =110 V dc 4. Accessories Connection cables 5m, 1MRS 120511.005, 5 pieces Pre-manufactured fibre sensors 10 m, 1MRS 120512.010, 13 pieces Pre-manufactured lens sensors 7 m, 1MRS 120534-7.0, 16 pieces 5. Number of REA 103 units 3 6. Number of REA 105 units 2 7. Number of REA 107 units 2 2UGHUQXPEHUV Arc protection relay REA 101 U n = 110 240 V ac U n = 110 220 V dc Arc protection relay REA 101 U n = 24 60 V dc Arc protection relay REA 101 with optolink connectors for glass fibre U n = 110 240 V ac U n = 110 220 V dc Arc protection relay REA 101 with optolink connectors for glass fibre U n = 24 60 V dc 1MRS 090416-AAA *) 1MRS 090416-CAA *) 1MRS 090416-AAAG *) 1MRS 090416-CAAG *) Rear plate protective cover 1MRS 060196 Mounting kit for semi-flush mounting 1MRS 050254 Mounting kit for surface mounting 1MRS 050240 Mounting kit for connecting cases together 1MRS 050241 Mounting kit for 19 rack 1MRS 050258 Extension unit REA 103 1MRS 090417-AA Extension unit REA 105 1MRS 090418-AA Extension unit REA 107 REA 107-AA *) Includes mounting kit 1MRS 050209 for flush mounting 3UHPDQXIDFWXUHGILEUHVHQVRUV Length Order number 5 m ±3% 1MRS 120512.005 10 m ±3% 1MRS 120512.010 15 m ±3% 1MRS 120512.015 20 m ±3% 1MRS 120512.020 25 m ±3% 1MRS 120512.025 30 m ±3% 1MRS 120512.030 40 m ±3% 1MRS 120512.040 50 m ±3% 1MRS 120512.050 60 m ±3% 1MRS 120512.060 $FFHVVRULHVIRUPDQXIDFWXULQJILEUHVHQVRUV Sensor fibre 100 m 1MSC 380018.100 Sensor fibre 300 m 1MSC 380018.300 Sensor fibre 500 m 1MSC 380018.500 ST connector SYJ-ZBC 1A1 ST splice adapter SYJ-ZBC 1A2 ST fibre termination kit 1MSC 990016 11

3UHPDQXIDFWXUHGOHQVVHQVRUVIRU5($ 1,5 m ±3% 1MRS 120534-1.5 3 m ±3% 1MRS 120534-3.0 5 m ±3% 1MRS 120534-5.0 7 m ±3% 1MRS 120534-7.0 10 m ±3% 1MRS 120534-10 15 m ±3% 1MRS 120534-15 20 m ±3% 1MRS 120534-20 25 m ±3% 1MRS 120534-25 30 m ±3% 1MRS 120534-30 3UHPDQXIDFWXUHGOHQVVHQVRUVIRU5($5($DQG5($ 2 m ±3% 1MRS 120536-2 3 m ±3% 1MRS 120536-3 5 m ±3% 1MRS 120536-5 10 m ±3% 1MRS 120536-10 6SDUHSDUWVIRUOHQVVHQVRUV Light collecting lens 1MRS060743 &DEOHVIRUFRQQHFWLQJ5($WRDQH[WHQVLRQXQLWRUH[WHQVLRQXQLWVWRHDFK DQRWKHU 1 m ±3% 1MRS 120511.001 3 m ±3% 1MRS 120511.003 5 m ±3% 1MRS 120511.005 10 m ±3% 1MRS 120511.010 15 m ±3% 1MRS 120511.015 20 m ±3% 1MRS 120511.020 30 m ±3% 1MRS 120511.030 40 m ±3% 1MRS 120511.040 3ODVWLFILEUHRSWROLQNIRUVLJQDOWUDQVIHUEHWZHHQFHQWUDOXQLWV 1 m ±3% SPA-ZF AA 1 2 m ±3% SPA-ZF AA 2 3 m ±3% SPA-ZF AA 3 5 m ±3% SPA-ZF AA 5 10 m ±3% SPA-ZF AA 10 20 m ±3% SPA-ZF AA 20 30 m ±3% SPA-ZF AA 30 40 m ±3% 1MRS 120517 *ODVVILEUHRSWROLQNIRUVLJQDOWUDQVIHUEHWZHHQFHQWUDOXQLWV 50 m ±3% SPA-ZF1MM50 60 m ±3% SPA-ZF1MM60 70 m ±3% SPA-ZF1MM70 80 m ±3% SPA-ZF1MM80 90 m ±3% SPA-ZF1MM90 100 m ±3% *) SPA-ZF1MM100 *) Note! Lengths over 100 m on request, max. length 2000 m 12

References $GGLWLRQDOLQIRUPDWLRQ REA 101 Operator s Manual REA 103 Operator s Manual REA 105 Operator s Manual REA 107 Operator s Manual 1MRS 751003-MUM EN 1MRS 751004-MUM EN 1MRS 751005-MUM EN 1MRS 752135-MUM EN 13

ABB Oy Substation Automation P.O. Box 699 FIN-65101 Vaasa, Finland Tel +358 10 22 11 Fax +358 10 224 1094 www.abb.com/substationautomation