Motor protection plugs



Similar documents
Phone: Fax: Web: info@clrwtr.com

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

8146/5 Series Breaker Panelboards

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

*.ppt 11/2/ :48 PM 1

Motor circuit-breakers

Technical catalogue. Modular DIN rail components Installation contactors

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

WE-350 Series ¼ Turn Electric Actuator

COOL Shelf Quick Connect

ASSEMBLED SOCKET-COMBINATIONS

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

PSR The compact range Description

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Circuit Breakers. NRC Series. NRC Series

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Failure code manual. content

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Product Information Sheet UH28CS-12kV Hi Pot Tester

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

Emergency lighting units EM powerled

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

SMS 4 / SMS 5 safety mat Product information

Number 1 in efficiency

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Cable Plug acc. to DIN EN , Form A

Labotek Reservedelside

, User s Manual

ACS-30-EU-EMDR-10-MOD

Thermal-Magnetic Circuit Breaker M1-..

CRN A-F-G-E-HQQE 3x400D 50 HZ

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Circuit Breakers. Next Generation of Protection Capabilities

Control Panels. Single-phase electric panels for submersible pumps QSM - QPC - QPCS - QSC - QSCS

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

THERMAL RELAYS, MOTORSTARTERS

LC/LCD ranges level controllers

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

E2 Series Electric Furnaces

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Liquid Level Limit Switch liquiphant T FTL 20

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

User s Manual Before using the inverter, you need to read and save the safety instructions.

Series 8146/5-V37 and Series 8150/5-V37

ST Series POWER SUPPLIES USER INSTRUCTIONS

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

IEC 309 INTERLOCKS NORTH AMERICAN

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Reversing starter circuit for single phase induction motors Updated 1 st September 2008

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Heating, air-conditioning, cooling

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

ENERGY-SAVINg DRIVE PACKAGE DE ES FR IT. Overview

Electronic overload relay EF19 and EF45

Duct Humidity Transmitter

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

ELECTROMAGNETIC DISC BRAKES

Catalog. Modular DIN rail components Installation contactors

Installation and maintenance instructions. Danfoss Vent

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

ESB and EN installation contactors Application handbook

IntesisBox KNX Mitsubishi Heavy Industries AC

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Pressure transmitter For general industrial applications Model A-10

Products and solutions for machine builders (OEM) 100% electricity

Plug and Socket Devices CES 63 A Series 8579

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

N8LED Large Area Lighting

Series description: Wilo-Drain TC 40

Phone: Fax: Web: info@clrwtr.com

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Manual. Solar Fountain Mobile Phone Charger

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

PS1800 Centrifugal Pumping Systems

GSM HOME SECURITY SYSTEM

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Stroom voor elke toepassing

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

HARTING Ethernet Cabling 4-poles Overview

Transcription:

Motor protection plugs

Motor protection plugs Results without motor protection plugs: Do you know the problem of >>...a destroyed engine? >>...a defective arrangement? >>...a burnt through winding by overloading? >>...mechanical damage on account of wrong rotation direction? >>...secondary damage such as flooding? Field of Applications >> Pumps Submerged pumps, mobile pumping plants, pumps for construction sites, water pumps,... >> Agitators Mobile machines for mixing (building site machines) >> Blowers Ventilators, space ventilation,... >> Compressors Breathing air compressors, mobile compressors,... >> Conveyors Rolling and chain conveyors, band-conveyors,... >> Industrial motors >> Construction machines Circular saws, hand tools,... >> Extractions mobile laboratory ventilation, smoke extraction,... 159

Motorprotection plugs 16A 230V 1,5-8,0A Motorprotection with schuko plug 16A 230V for all one-phase motors Technical datas: Enclosure material: PC/ABS Protection degree: IK standard acc. EN50102: IK09 Temperature range: -5 C to +40 C large connection area 90 55 68 110 138 Designs: with rocker switch ON/OFF (I-0) or HAND ORATION/ AUTOMATIC (H-A) for the use of a float switch* with rocker switch HAND ORATION/OFF/AUTOMATIC (I - 0 - II) change between continuous duty, Off and Automatic for the use of a float switch* circuit breaker with external reset switch currents: 1,5A, 3A, 4A, 5A, 6,5A, 8A cable entry: 1,5-8,0A: 2xM16 cable glands (ø 5-10mm) 1x marking for break through enlargement up to ø 20mm [ min ] [ sec ] 10`000 Rated current / Nennstrom The motor protection plug 16A 230V provides reliable protection for overload. It is used mainly for switching and the protection of one-phase AC motors on pumps, circular saws and industrial motors. 60 30 20 2`000 1`000 < 6,5 A 6,5 A Ambient temp. / Umgebungstemp. +23 ϒC 10 5 500 200 -X1 16A 3p L1 N -X1 L1 N 16A 3p 1 100 50 20 Hand / EIN -F1 xxa -S1 -F1 Hand / EIN xxa AUS -S1 10 5 Automatik oder AUS Automatik Tripping time / Auslösezeit 2 1 0,5 0,3 0,2 0,1 1,05 1,35 Multiple of rated current Nennstrom-Vielfaches 2 3 4 5 8 10 [xin ] -X2 L N S1 S2 X1.. Schutzkontaktstecker 16A 3p X2.. Klemmleiste - 2,5mm² S1/S2.. Schwimmerschalter (optional) -X2 L N S1 S1/S2.. Schwimmerschalter (optional) S2 X1.. Schutzkontaktstecker 16A 3p X2.. Klemmleiste - 2,5mm² Motor protection plug 16A 230V Hand operation - Automatic or On - Off Motor protection plug 16A 230V Hand operation - Off - Automatic setting range cable gland 1,5A 2xM16 5-10mm 56101500 3,0A 2xM16 5-10mm 56103000 4,0A 2xM16 5-10mm 56104000 5,0A 2xM16 5-10mm 56105000 6,5A 2xM16 5-10mm 56106000 8,0A 2xM16 5-10mm 56108000 setting range cable gland 3,0A 2xM16 5-10mm 56103001 4,0A 2xM16 5-10mm 56104001 160 * Float switch see page 167

Motorprotection plugs 16A 230V 10-16A Motorprotection with schuko plug 16A 230V for all one-phase motors Technical datas: Enclosure material: PC/ABS Protection degree: IK standard acc. EN50102: IK09 Temperature range: -5 C to +40 C large connection area Designs: with rocker switch ON/OFF which lights green when switched on change between continuous duty, Off and Automatic for the use of a float switch* currents: 10A, 12A, 14A, 15A, 16A cable entry: 10-16A: 1xM16 cable glands (ø 5-10mm) 1x marking for break through enlargement up to ø 16mm 90 55 68 110 138 [ min ] [ sec ] 10'000 60 Type R ated cu rrent TA35 <3 A (TC-1) 1, 2 pole 30 20 2`000 1`000 3 pole Ambient temp. +23 C 10 5 500 200 -X1 16A3p L1 N 100 1 50 20 10 ON OFF -S1 xxa P1 5 2 1 4 L 0,5 Tripping time 0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 10 X1..plug 16A3p X2..terminal- 2,5mm² Multiple of rated current [xin ] -X2 L N S1 S2 Motor protection plug 16A 230V Hand operation - Automatic or On - Off setting range cable gland 10A 1xM16 5-10mm 56110004 12A 1xM16 5-10mm 56112004 14A 1xM16 5-10mm 56114004 15A 1xM16 5-10mm 56115004 16A 1xM16 5-10mm 56116004 Cat.No. 161

CEE-plugs with switch CEE-ON/OFF-Switch ML0-Plug ON/OFF switch: AC22A, 10kA cable gland: 4p M25, 5p M25 without operating display 54014530 54015530 with operating display 540145301 540155301 CEE-ON/OFF-Switch ML0-Plug ON/OFF switch: AC22A, 10kA cable gland: 4p M25, 5p M32 without operating display 54024530 54025530 with operating display 540245301 540255301 CEE-ON/OFF-Switch ML0-Plug with phase inverter ON/OFF switch: AC22A, 10kA cable gland: 4p M25, 5p M32 without display 54714530 54715530 with operating display 547145301 547155301 with rotating field check 547145303 547155303 CEE-ON/OFF-Switch ML0-Plug with phase inverter ON/OFF switch: AC22A, 10kA cable gland: 4p M25, 5p M32 without display 54724530 54725530 with operating display 547245301 547255301 with rotating field check 547245303 547255303 CEE-plug with reversing switch CA10 AC22A cable gland: 4p M25, 5p M25 without operating display 54014610 54015610 with operating display 540146101 540156101 CEE-plug with reversing switch CA25 AC22A cable gland: 4p M25, 5p M32 without operating display 54024625 54025625 with operating display 540246251 540256251 Cat.No. 162

plugs CEE plug with motor protection switch Z-MS and PKZM0: Technical data: 274 (288) 235 (243) 202 (202) housing material: PC/ABS protection degree IK standard acc. EN50102: IK09 all designs available with or without holder large connection area 274 (288) 235 (243) 202 (202) 97 98 95 314* (324)* dimensions: 16A (32A) * dimensions only valid for design with holder 95 97 314* (324)* Details of Z-MS and PKZM0: reliable means of protection against thermal overloading and short circuiting all protection switches feature thermal overload and magnetic short circuit triggering short circuit capacity of Z-MS 10kA and PKZM0: 50kA respectively Rotating field check: Displays a field rotating in anti-clockwise direction. Operating display: Indicates the voltage supply of two phases of the connector. Main field of application: Switching and protection of AC 3-phase motors with outputs of up to 15kW such as industrial motors and those fitted to pumps and circular cold saws etc. Z-MS Characteristic: PKZM0 Characteristic: 163

plugs PKZM0 with rotary lever plug PKZM0 plug PKZM0 plug PKZM0 with operating display Setting range cable gland 1,0-1,6A 4p and 5p M25 54014016 54015016 1,6-2,5A 4p and 5p M25 54014025 54015025 2,5-4,0A 4p and 5p M25 54014040 54015040 4,0-6,3A 4p and 5p M25 54014063 54015063 6,3-10A 4p and 5p M25 54014100 54015100 10-16A 4p and 5p M25 54014160 54015160 1,0-1,6A 4p M25; 5p M32 54024016 54025016 1,6-2,5A 4p M25; 5p M32 54024025 54025025 2,5-4,0A 4p M25; 5p M32 54024040 54025040 4,0-6,3A 4p M25; 5p M32 54024063 54025063 6,3-10A 4p M25; 5p M32 54024100 54025100 10-16A 4p M25; 5p M32 54024160 54025160 16-20A 4p M25; 5p M32 54024200 54025200 20-25A 4p M25; 5p M32 54024250 54025250 25-32A 4p M25; 5p M32 54024320 54025320 1,0-1,6A 4p and 5p M25 540140161 540150161 1,6-2,5A 4p and 5p M25 540140251 540150251 2,5-4,0A 4p and 5p M25 540140401 540150401 4,0-6,3A 4p and 5p M25 540140631 540150631 6,3-10A 4p and 5p M25 540141001 540151001 10-16A 4p and 5p M25 540141601 540151601 with holder 53xxxxxxx 53xxxxxxx plug PKZM0 with operating display plug PKZM0 with phase inverter 1,0-1,6A 4p M25; 5p M32 540240161 540250161 1,6-2,5A 4p M25; 5p M32 540240251 540250251 2,5-4,0A 4p M25; 5p M32 540240401 540250401 4,0-6,3A 4p M25; 5p M32 540240631 540250631 6,3-10A 4p M25; 5p M32 540241001 540251001 10-16A 4p M25; 5p M32 540241601 540251601 16-20A 4p M25; 5p M32 540242001 540252001 20-25A 4p M25; 5p M32 540242501 540252501 25-32A 4p M25; 5p M32 540243201 540253201 with holder 53xxxxxxx 53xxxxxxx 1,0-1,6A 4p and 5p M25 547140163 547150163 1,6-2,5A 4p and 5p M25 547140253 547150253 2,5-4,0A 4p and 5p M25 547140403 547150403 4,0-6,3A 4p and 5p M25 547140633 547150633 6,3-10A 4p and 5p M25 547141003 547151003 10-16A 4p and 5p M25 547141603 547151603 with holder 53xxxxxxx 53xxxxxxx plug PKZM0 with phase inverter 1,0-1,6A 4p M25; 5p M32 547240163 547250163 1,6-2,5A 4p M25; 5p M32 547240253 547250253 2,5-4,0A 4p M25; 5p M32 547240403 547250403 4,0-6,3A 4p M25; 5p M32 547240633 547250633 6,3-10A 4p M25; 5p M32 547241003 547251003 10-16A 4p M25; 5p M32 547241603 547251603 16-20A 4p M25; 5p M32 547242003 547252003 20-25A 4p M25; 5p M32 547242503 547252503 25-32A 4p M25; 5p M32 547243203 547253203 with holder 53xxxxxxx 53xxxxxxx 164

plugs Z-MS with toggle switch plug Z-MS Setting range cable gland 1,0-1,6A 4p and 5p M25 51014016 51015016 1,6-2,5A 4p and 5p M25 51014025 51015025 2,5-4,0A 4p and 5p M25 51014040 51015040 4,0-6,3A 4p and 5p M25 51014063 51015063 6,3-10A 4p and 5p M25 51014100 51015100 10-16A 4p and 5p M25 51014160 51015160 with holder 50xxxxxx 50xxxxxx plug Z-MS 1,0-1,6A 4p M25; 5p M32 51024016 51025016 1,6-2,5A 4p M25; 5p M32 51024025 51025025 2,5-4,0A 4p M25; 5p M32 51024040 51025040 4,0-6,3A 4p M25; 5p M32 51024063 51025063 6,3-10A 4p M25; 5p M32 51024100 51025100 10-16A 4p M25; 5p M32 51024160 51025160 16-25A 4p M25; 5p M32 51024250 51025250 25-40A 4p M25; 5p M32 51024400 51025400 with holder 50xxxxxx 50xxxxxx plug Z-MS with operating display 1,0-1,6A 4p and 5p M25 510140161 510150161 1,6-2,5A 4p and 5p M25 510140251 510150251 2,5-4,0A 4p and 5p M25 510140401 510150401 4,0-6,3A 4p and 5p M25 510140631 510150631 6,3-10A 4p and 5p M25 510141001 510151001 10-16A 4p and 5p M25 510141601 510151601 with holder 50xxxxxx 50xxxxxx plug Z-MS with operating display 32A 4p 32A 4p 1,0-1,6A 4p M25; 5p M32 510240161 510250161 1,6-2,5A 4p M25; 5p M32 510240251 510250251 2,5-4,0A 4p M25; 5p M32 510240401 510250401 4,0-6,3A 4p M25; 5p M32 510240631 510250631 6,3-10A 4p M25; 5p M32 510241001 510251001 10-16A 4p M25; 5p M32 510241601 510251601 16-25A 4p M25; 5p M32 510242501 510252501 25-40A 4p M25; 5p M32 510244001 510254001 with holder 50xxxxxxx 50xxxxxxx plug Z-MS with phase inverter 1,0-1,6A 4p and 5p M25 517140163 517150163 1,6-2,5A 4p and 5p M25 517140253 517150253 2,5-4,0A 4p and 5p M25 517140403 517150403 4,0-6,3A 4p and 5p M25 517140633 517150633 6,3-10A 4p and 5p M25 517141003 517151003 10-16A 4p and 5p M25 517141603 517151603 with holder 50xxxxxxx 50xxxxxxx plug Z-MS with phase inverter 32A 4p 32A 4p 1,0-1,6A 4p M25; 5p M32 517240163 517250163 1,6-2,5A 4p M25; 5p M32 517240253 517250253 2,5-4,0A 4p M25; 5p M32 517240403 517250403 4,0-6,3A 4p M25; 5p M32 517240633 517250633 6,3-10A 4p M25; 5p M32 517241003 517251003 10-16A 4p M25; 5p M32 517241603 517251603 16-25A 4p M25; 5p M32 517242503 517252503 25-40A 4p M25; 5p M32 517244003 517254003 with holder 50xxxxxxx 50xxxxxxx Cat.No. 165

plugs contactor up to 7,5kW plug contactor up to 5,5kW (16A) and 7,5kW (32A) Technical datas: enclosure material: PC/ABS protection degree: IK standard acc. to EN50102: IK09 temperature range: -25 C bis +40 C large connection area Designs: with rocker switch ON/OFF and MANUELL/AUTOMATIC for the use of a float switch* with phase inverter plug rotation field check - anticlockwise phase sequence operating display - shows the voltage supply of the contactor and therefore of the consumer load external reset switch for the motor protection relay cable entry: bottom part: 1x cable gland M25 (ø 13-18mm) at 16A and M32 (ø 13-20mm) at 32A top part: 1x cable gland M16 (ø 5-10mm) for float switch (separate drill hole marking for a further M16 cable gland) CEE Stecker 16/32A 5p -X1 L1 L2 L3 N 1 3 5 -K1 6 2 4 6 1 3 5 -F1 2 4 6 U V W 96 95 Br/Schw/Gr -H1 -F2 10A Drehfeldkontrolle 13 -K1 14 -H2 Betriebsanzeige -S1 = Schalter Manuell / Automatik -X2 -S2 = Schalter ON / OFF -X2 = Erderklemmen - 16mm² -X3 = Steuerungsklemmen - 2,5mm² -K1 A1 A2 95 -F1 96 -S1 -X3 S1 S2 13 -S2 14 13 14 -X3 T1 T2 Schwimmerschalter Thermokontakt (optional) (optional) The CEE motor protection plug up to 7,5 kw provides reliable protection for thermal overloads and short circuits. It is used mainly for switching and the protection of threephase AC motors up to 7,5 kw (400V) on pumps, circular saws and industrial motors etc... 101 97 274 202 235 plug with contactor 16A 5p 400V with phase inverter plug with operation display Setting contactor range (AC3) cable gland 16A 1,0-1,6A 4,0 kw M25 (13-18mm) 5571501000 1,6-2,4A 4,0 kw M25 (13-18mm) 5571501600 2,4-4,0A 4,0 kw M25 (13-18mm) 5571502400 4,0-6,0A 4,0 kw M25 (13-18mm) 5571506000 6,0-10A 5,5 kw M25 (13-18mm) 5571510000 9,0-12A 5,5 kw M25 (13-18mm) 5571512000 12-16A 7,5 kw M25 (13-18mm) 5571516000 Motorschutzstecker mit Schütz 16A 5,5kW 101 288 202 243 plug with contactor 32A 5p 400V with phase inverter plug with operation display Setting contactor range (AC3) cable gland 16A 6,0-10A 7,5 kw M32 (12-21mm) 5572510000 9,0-12A 7,5 kw M32 (12-21mm) 5572512000 12-16A 7,5 kw M32 (12-21mm) 5572516000 97 Motorschutzstecker mit Schütz 32A 7,5kW * Float switch see page 167 166

plugs contactor up to 15 kw plug contactor up to 15 kw (32A) Technical datas: enclosure material: solid rubber protection degree: (IP66 on request) dimensions: HxWxD = 260x165x90mm temperature range: -25 C to +40 C large connection area Designs: with rotary switch I = hand operation, 0 = Off, II = automatic operation 2m cable H07RN-F 5G4 with phase inverter plug 32A 5p 400V rotation field check - anticlockwise phase sequence reset switch behind transparent window float switch on request level control system and dipped electrodes on request cable entry: 1x cable gland M32 (Ø 13-20mm) 2x cable glands M16 (Ø 5-10mm) for float switch and thermo switch operation display contactor -X1 -W1 Anschlussleitung H07RN-F 5G4 CEE Stecker 32A 5p L1 L2 L3 N -F2 5A The CEE motor protection plug up to 15kW provides reliable protection for thermal overloads and short circuits. It is used mainly for switching and the protection of three-phase AC motors on pumps, circular saws and industrial motors... 1 3 5 -F1 xxa I> I> I> 2 46 14 13 1 3 5 -K1 2 4 6 -X2 -X3 U V W Br / Sw / Gr -H1 Drehfeldkontrolle A1 -K1 A2 13 -F1 14 -X2 T1 T2 Hand H-0-A AUS -S1 H Automatik -X2 S2 A S1 -X2.. Klemmleiste - 2,5mm² -X3.. Erderklemme - 10mm² Thermokontakt (optional) Schwimmerschalter (optional) plug glandwith contactor up to 15 kw (32A) with rotary switch I-0-II with phase inverter plug Setting range contactor cable gland 16-20A 12,5 kw M32 (12-20mm) 9216211 2xM16 (5-10mm) 20-25A 12,5 kw M32 (12-20mm) 9216210 2xM16 (5-10mm) 25-32A 15,0 kw M32 (12-20mm) 9216212 2xM16 (5-10mm) Float switch Technical data: protection degree: IP68 temperature range: -5 C to +60 C switching capacity: max. 400VAC 10(4)A min. 250VAC 10(8)A durability: > 50.000 cycles beam angle hysteresis: min. 140mm to max. 400mm Designs: changer (top: brown-grey, bottom: brown-black) hot plate welded housing elastomer sealed cable entry cable: Nexans 05RN8-F 4G1mm² black (10m or 20m) with 10m cable 1023011 with 20m cable 1023012 Cat.No. 167

PC Electric GesmbH Diesseits 145 4973 St. Martin im Innkreis AUSTRIA TEL +43 7751 61220 FAX +43 7751 6969 office@pcelectric.at