3-Wire Wallbox Adapter For Seeburg SMC jukeboxes with the GEN2 MCU



Similar documents
PUSH BUTTON START INSTALLATION MANUAL

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

REPAIRING ROWE/AMI R84 - R88

Rock-Ola Music Center Set-Up and Installation Guide For all Q-Series models 230V, Export

To Purchase This Item, Visit BMI Gaming Operation Manual

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Manual Ranging MultiMeter

TM Advanced Tracking Technologies, Inc ATTI All rights reserved

PRO PLM Installation Instructions

7 FUNCTION DIGITAL MULTIMETER

OPL BASIC. Dosing System for Professional Laundry machines. Contents

INSTALLATION GUIDE. FCC ID NOTICE

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

AutoRanging Digital MultiMeter

Ground Resistance Clamp On Tester

SMPTE Time Code Generator/Reader

i ChatterBox! Motorcycle Security

User s Information Guide R1A

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

ViZion Installation Guide

User Guide. 4 wire Earth Resistance Tester Model GRT300

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS


Seven function digital multimeter

3 Slot Payphone Controller

Renewable Energy Monitor User Manual And Software Reference Guide. (979)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

NC-12 Modbus Application

LUCCI AIRFUSION QUEST II CEILING FAN

INSTALLATION & SERVICE MANUAL. Display Panel

SYSTEM 4C. C R H Electronics Design


Gemini II. Subwoofer System OWNERS MANUAL

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

12-Volt 10-Amp Regulated Power Supply

Advantium 2 Plus Alarm

Model 201 Wiegand Touchpad Reader Installation Guide

LOXONE 12 Channel Amplifier

SOLAR POWER - THE NEW WAY TO RV!

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

POWER TRIM 5 F AUTO TRIM AND AUTO TRIM

40 Watt Mixer Amplifier Owners Manual with Media Player

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

25 Code GTO Digital Keypad

User's Guide. True RMS Industrial Multimeter

USER MANUAL MODEL

Essential Electrical Concepts

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Installation and Operation Guide for PD5100 Automatic Transfer Switch

COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

How To Use A Cdm250 Digital Multimeter

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

COASTAL AMUSEMENTS INC.

GST301. (Single Protection Zone) Operation Manual

12 Volt 30 Amp Digital Solar Charge Controller

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Water Leak Detection System

Windshield Wiper Motors

Build A Video Switcher. Reprinted with permission from Electronics Now Magazine September 1997 issue

AUTODIALLER / QUICKDIALLER - SA132

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

±15 V Current-Limited Power Supply

TruPower-Portable-500W. Solar Starter kit

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

Analog Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators

C O B A R 1 8R2 U s e r G u i d e P a g e 1. User Guide COBRA 18R2. Wireless Firing System.

USB to RS-422/485 Serial Adapter

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

HSG Engineering Tech Bulletin

Magic Poker 2 Manual

Instructions A Amp AC/DC Current Probe

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Snap-It. This is an accessory (switch machine) decoder

200W DISCRETE POWER AMPLIFIER K8060

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Pro Logic Version Diagnostics Manual

The $25 Son of a cheap timer This is not suitable for a beginner. You must have soldering skills in order to build this kit.

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

TMS TANK MANAGEMENT SYSTEM

D287/D288/D292/D293A/D293E

Diagnosing and Understanding Starting Problems on the ZR-1 Marc Haibeck 28-Sep-13


SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Transcription:

3-Wire Wallbox Adapter For Seeburg SMC jukeboxes with the GEN2 MCU Connect any 3-wire wallbox selector to your Seeburg SMC jukebox Requires the 'GEN2' Microcomputer Control Unit AMI W-40 AMI W-80 AMI W-120 AMI WQ-200 Rock-Ola 500 Rock-Ola 503 Rock-Ola 1555 Rock-Ola 1558 Rowe WRA Rowe WRB Rowe WRC Seeburg 3W1 Seeburg 3W100 Seeburg 3WA Seeburg SC1-4 Seeburg SCH1-4 Wurlitzer 3020 Wurlitzer 5207 Wurlitzer 5210 Wurlitzer 5220 Wurlitzer 5225 Wurlitzer 5250 ORDER PART # SMC-WB5 for 50Hz version WALLBOX MODEL SETUP Move the SERVICE SWITCH on the CPA panel to SERVICE MODE. The display will show SCE and the current 2-digit record position number. While holding the CREDIT switch on, press digit 4 for GENERAL SETUP. Use the Left or Right RESET key and get to the rse setting (Remote Selector type). From the list below, enter the 1 or 2 digit wallbox model code. Move the SERVICE SWITCH back to NORMAL PLAY MODE. rse WALLBOX MODEL Max Sel Seq Type 0 Seeburg digital DEC (requires the blue box DMT1, DEC-MCU TRANSLATOR) 160 1 Seeburg Consolette SC1/2/3/4, SCH1/2/3/4 160 Letter 2 Wurlitzer 5210, 5220, 5250 160 Number 3 Seeburg Wall-O-Matic 3W1, 3W100 100 Number 4 Seeburg Wall-O-Matic 3WA 160 Letter 5 Rowe WRA, WRB, WRC 160 Letter 6 AMI W-40, W-80, W-120, WQ200 160 Button 7 Wurlitzer 5207 104 Button 8 Wurlitzer 5225 100 Number 9 Wurlitzer 3020 24 Button 10 Rock-Ola 500, 1555, 1558 (and most other models) 160 Button Data Sync Engineering P.O. Box 539, 2 Footbridge Lane Blairstown, New Jersey 07825 TEL: (908) 362-6299 FAX: (908) 362-5889 www.datasynceng.com Copyright 2010 Data Sync Engineering. All Rights Reserved. Designated trademarks and brands are the property of their respective owners.

WALLBOX SYSTEM WIRING WALLBOX SELECTOR WALLBOX ADAPTER J2 SIG SMC-WB 3-Wire Wallbox Adapter for GEN2 Seeburg SMC MCU COM WALLBOX POWER NOT SUPPLIED But required to power wallbox (YELLOW) (YELLOW) SEEBURG SMC MCU GEN2 ADAPTER INSTALLATION In-line fuse holder with 1A fuse Black wire is not used. Apply tape or wire nut. POWER TRANSFORMER 25-30 VAC, 2 Amps Radio Shack 273-1512 or equivalent Insert the 9-pin connector to the J2 position on the GEN2 MCU board. The 2-wire zipcord receives the signal from the wallbox. You can extend the length of the wallbox signal wires, using 22AWG, to a distance of up to 2,000 feet (609.6 meters). The wallbox signal is and has no specific wire polarity. You will need a 25-30 Volt, 2 Amp power transformer to power the wallbox Locate your wallbox model in the following pages for wiring detail. TECH NOTE Electrical pulses transmitted by the wallbox are generated by a contact arm rotating on a selector disc containing contact points. When these contacts become gummed up and corroded, the wallbox may not make the proper selection. Occasionally, these contacts require cleaning. They can be cleaned with a cloth saturated with isopropyl alcohol. Do not use emery cloth or sandpaper as this may remove the plating. On really worn wallboxes, where basic cleaning doesn t seem to cure the problem, you may have successful results by using a low abrasive polish, such as Scratch Out or Brasso. This will make the contact surfaces shiny and smooth.

NBR LTR SEL REC A1 A2 A3 A4 A5 A6 A7 A8 A9 A0 B1 B2 B3 B4 B5 B6 B7 B8 B9 B0 C1 C2 C3 C4 C5 C6 C7 C8 C9 C0 D1 D2 D3 D4 D5 D6 D7 D8 D9 D0 E1 E2 E3 E4 E5 E6 E7 E8 E9 E0 A1 B1 C1 D1 E1 F1 G1 H1 J1 K1 L1 M1 N1 P1 Q1 R1 S1 T1 U1 V1 A2 B2 C2 D2 E2 F2 G2 H2 J2 K2 L2 M2 N2 P2 Q2 R2 S2 T2 U2 V2 A3 B3 C3 D3 E3 F3 G3 H3 J3 K3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 100 200 101 201 102 202 103 203 104 204 105 205 106 206 107 207 108 208 109 209 110 210 111 211 112 212 113 213 114 214 115 215 116 216 117 217 118 218 119 219 120 220 121 221 122 222 123 223 124 224 NBR LTR SEL REC F1 F2 F3 F4 F5 F6 F7 F8 F9 F0 G1 G2 G3 G4 G5 G6 G7 G8 G9 G0 H1 H2 H3 H4 H5 H6 H7 H8 H9 H0 J1 J2 J3 J4 J5 J6 J7 J8 J9 J0 K1 K2 K3 K4 K5 K6 K7 K8 K9 K0 L3 M3 N3 P3 Q3 R3 S3 T3 U3 V3 A4 B4 C4 D4 E4 F4 G4 H4 J4 K4 L4 M4 N4 P4 Q4 R4 S4 T4 U4 V4 A5 B5 C5 D5 E5 F5 G5 H5 J5 K5 L5 M5 N5 P5 Q5 R5 S5 T5 U5 V5 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 125 225 126 226 127 227 128 228 129 229 130 230 131 231 132 232 133 233 134 234 135 235 136 236 137 237 138 238 139 239 140 240 141 241 142 242 143 243 144 244 145 245 146 246 147 247 148 248 149 249 NBR LTR SEL REC L1 L2 L3 L4 L5 L6 L7 L8 L9 L0 M1 M2 M3 M4 M5 M6 M7 M8 M9 M0 N1 N2 N3 N4 N5 N6 N7 N8 N9 N0 P1 P2 P3 P4 P5 P6 P7 P8 P9 P0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q0 A6 B6 C6 D6 E6 F6 G6 H6 J6 K6 L6 M6 N6 P6 Q6 R6 S6 T6 U6 V6 A7 B7 C7 D7 E7 F7 G7 H7 J7 K7 L7 M7 N7 P7 Q7 R7 S7 T7 U7 V7 A8 B8 C8 D8 E8 F8 G8 H8 J8 K8 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 150 250 151 251 152 252 153 253 154 254 155 255 156 256 157 257 158 258 159 259 160 260 161 261 162 262 163 263 164 264 165 265 166 266 167 267 168 268 169 269 170 270 171 271 172 272 173 273 174 274 NBR LTR SEL REC R1 R2 R3 R4 R5 R6 R7 R8 R9 R0 L8 M8 N8 P8 Q8 R8 S8 T8 U8 V8 151 152 153 154 155 156 157 158 159 160 175 275 176 276 177 277 178 278 179 279 SEQUENCED NUMBER SEQUENCED LETTER SELECTION BUTTON RECORD SELECTED WALLBOX TRANSLATION CHART

Wallbox Wiring Diagrams CAUTION: Do not attempt to hook up a wallbox power supply if you are not familiar with electrical wiring, consult with a qualified person or an electrician. Do not leave any wires exposed, always use wire-nuts or electrical tape on all connections. Improper wiring can result in a fire or shock hazard. Seeburg Wall-o-matic 3W1 / 3W100 100 select Seeburg Wall-o-matic 3WA

Seeburg Consolette SC1-4 / SCH1-4 160 select BLK WHT BLU To enable coin operation, the BRN / RED / ORG terminals must be shorted together and connected to the terminal (WHT) using a 40-50 Ohm, 10 Watt power resistor (solenoid current = 400mA). Wurlitzer 5220 Wurlitzer 5225 100 select 3 G 1

Wurlitzer 5207 104 select AMI W-40 / W-80 / W-120 40 / 80 / 120 select Rowe WRA / WRB / WRC 1 2 3 4 * A wire jumper must be inserted from the main power terminal (#2) to the * keypad motor terminal (#4).

Wurlitzer 5210 Wurlitzer 5250 Rock-Ola 1555 Rock-Ola 1558 160 select Rock-Ola 500 160 select

Wurlitzer 3020 24 select The Original 1015 Bubbler Wallbox 120VAC This wallbox has its own built-in transformer and requires a 120VAC power cord. High voltage is used so be very careful when wiring up this wallbox. The wallbox adapter only requires the two wire connection to terminal #1 and terminal #3. AMI WQ-200 * A wire jumper must be inserted from the main power terminal to the * lock-out.