Emerson Network Power Rack PDU Systems



Similar documents
Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

AC Power For Business-Critical Continuity. Liebert MPH. User Manual North American & European Applications

Rack Power Distribution Unit For Critical IT Equipment

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG

DCF Optimized Rack System Selection Guide

Rack Power Distribution For Critical IT Equipment More efficient Simpler Better

QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

Rack Power Distribution

Distributing Power to Blade Servers

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Rack Power Distribution. Worldwide

QuickSpecs. HP 480/277 Volt Solutions. Overview

QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview

Rack Systems Solutions

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

How To Power A Bladecenter H Servers

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Power Commander Power Distribution Units from Wiremold/Legrand offer

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Model #: SMART2200CRMXL

PE8216/PE8324. Energy Intelligence Solutions

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

QuickSpecs. HP Remote Monitored Power Distribution Units (mpdu) Overview

Panduit Infrastructure Management Software for Data Centers and Enterprises

Remote Site Management Solutions

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

R5000 Uninterruptible Power System (UPS) Overview

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

R5000 Uninterruptible Power System (UPS) Overview

Adaptive power distribution in the data center

Uninterruptible Power Supply

Precisely distribute, monitor, analyze and manage power distribution in your facility to maximize processing capacity and promote power efficiency.

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

ED1259R5 Updated April 2011 For latest specs visit

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

Cisco Nexus 7000 Series Power Supply Modules

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

HP UPS R1500 Generation 3

PE6108/PE6208/PE8108/PE8208

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

APC Step-Down Transformer. User s Manual

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

MAJORSINE Power Inverter

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

IEC 309 INTERLOCKS NORTH AMERICAN

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

EKOS Cart. Instructions for Use

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

CS-24HEK4B3H2 (Master) CL-24HEK4B3H2 (Expansion) Key Features. Inputs

Power Distribution Considerations for Data Center Racks

HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

Eaton epdu Data Center Product Catalog

High-Efficiency AC Power Distribution for Data Centers

Eaton epdu. Intelligent and flexible power distribution

HP R12000 and R18000 DirectFlow UPS User Guide

Amplifier: AMP Feature Summary

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Internet Office 500VA Tower Standby 120V UPS with USB port

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Chassis, Power Supply, and Element Management

Power Supplies 3. SDN-P DIN Rail Series

BC Pro UPS System Standby UPS System

DVI DA2 and DVI DA 4 User Guide

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

TrueAlarm Fire Alarm Systems

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

3500/93 System Display

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

APC 3Phase Power Distribution

The Different Types of AC Power Connectors in North America

LIEBERT VNSA Installation Sheet

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Transcription:

AC Power For Business-Critical Continuity Emerson Network Power Rack PDU Systems Product Selection Guide - North American Models

TABLE OF CONTENTS 1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS..............................1 1.1 Safety and Agency Compliance................................................. 1 2.0 DETERMINING THE RIGHT EMERSON PDU FOR YOUR APPLICATION...................2 3.0 KNURR DI-STRIP PRODUCT SELECTION GUIDE - BASIC RACK PDUS.................3 3.1 Overview - Basic Rack PDUs................................................... 3 3.2 Basic Rack PDU Optional Cord Sets............................................. 4 3.3 Dimensional Drawings - Basic Rack PDUs........................................ 5 4.0 LIEBERT MPH PRODUCT SELECTION GUIDE - MANAGED RACK PDUS...............27 4.1 Overview - Managed Rack PDUs............................................... 27 4.2 Specifications - Liebert MPH.................................................. 28 4.3 Model Number Configuration - Liebert MPH..................................... 29 4.4 Managed Rack PDU Optional Cord Sets and Cable Restraints...................... 30 4.5 Dimensional Drawings - Managed Rack PDUs................................... 31 5.0 LIEBERT MPX - ADAPTIVE RACK PDUS......................................33 5.1 Overview - Adaptive Rack PDUs............................................... 33 5.2 MPX PRC (Power Rail Chassis)................................................ 35 5.3 MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord)................. 36 5.4 MPX BRM (Branch Receptacle Module)......................................... 36 5.5 Adaptive Rack PDU Optional Accessories....................................... 37 5.5.1 Cord Sets and Cable Restraints................................................. 37 5.5.2 Liebert RPC (RPC-1000) and Accessories....................................... 37 5.5.3 Part Numbers for Liebert RPC and Accessories.................................... 38 5.5.4 Ports on the Liebert RPC...................................................... 38 5.5.5 Liebert RPC Capabilities and Benefits........................................... 39 5.5.6 RPC BDM Basic Display Module.............................................. 40 5.5.7 Temperature/Humidity Sensor................................................. 40 6.0 LIEBERT MPX SYSTEM PRODUCT SELECTION GUIDE............................41 6.1 STEP 1 - Select an MPX PRC (Quantity x 1)..................................... 41 6.2 STEP 2 - Select an MPX PEM / MPX IPC (Quantity x 1)........................... 42 6.3 STEP 3 - Select an MPX BRM................................................. 44 6.4 STEP 4 - Select Communication Options........................................ 45 6.5 System Selection Guide...................................................... 46 6.6 Specifications for Liebert MPX Components..................................... 52 6.7 Dimensional Drawings - Adaptive Rack PDUs.................................... 53 i

FIGURES Figure 1 Knurr DI-STRIP 35351011........................................................ 5 Figure 2 Knurr DI-STRIP 35351021........................................................ 6 Figure 3 Knurr DI-STRIP 35351031........................................................ 7 Figure 4 Knurr DI-STRIP 35351041........................................................ 8 Figure 5 Knurr DI-STRIP 35351051........................................................ 9 Figure 6 Knurr DI-STRIP 35351061....................................................... 10 Figure 7 Knurr DI-STRIP 35351081....................................................... 11 Figure 8 Knurr DI-STRIP 35352011....................................................... 12 Figure 9 Knurr DI-STRIP 35352021....................................................... 13 Figure 10 Knurr DI-STRIP 35352031....................................................... 14 Figure 11 Knurr DI-STRIP 35352041....................................................... 15 Figure 12 Knurr DI-STRIP 35352051....................................................... Figure 13 Knurr DI-STRIP 35352061....................................................... 17 Figure 14 Knurr DI-STRIP 35352078....................................................... 18 Figure 15 Knurr DI-STRIP 35353011....................................................... 19 Figure Knurr DI-STRIP 35353021....................................................... 20 Figure 17 Knurr DI-STRIP 35353031....................................................... 21 Figure 18 Knurr DI-STRIP 35353041....................................................... 22 Figure 19 Knurr DI-STRIP 35353051....................................................... 23 Figure 20 Knurr DI-STRIP 35353061....................................................... 24 Figure 21 Knurr DI-STRIP 35353078....................................................... 25 Figure 22 Knurr DI-STRIP 35353088....................................................... 26 Figure 23 Liebert MPH rack mount power strip............................................... 31 Figure 24 Liebert MPH vertical power strip.................................................. 32 Figure 25 Liebert MPX 1880 and 1035 models and components.................................. 34 Figure 26 MPX PRC (Power Rail Chassis).................................................... 35 Figure 27 Liebert RPC ports............................................................... 38 Figure 28 RPC BDM..................................................................... 40 Figure 29 Temperature/humidity sensor..................................................... 40 Figure 30 Liebert MPX MPXPRC-1035mm mixed modules...................................... 53 Figure 31 Liebert MPX MPXPRC-1880mm mixed modules...................................... 54 TABLES Table 1 Specifications - Knurr DI-STRIP.................................................... 3 Table 2 Cord sets - Knurr DI-STRIP........................................................ 4 Table 3 Specifications - Liebert MPH...................................................... 28 Table 4 Cord sets and cable restraints - Liebert MPH......................................... 30 Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX............................. 46 Table 6 Selections for Power Entry Module MPXPEM-NHBXXV30.............................. 49 Table 7 Selections for Power Entry Module MPXPEM-NHBXXX30.............................. 50 Table 8 Selections for Power Entry Module MPXPEM-NHBXXW30............................. 51 Table 9 Specifications - MPX BRM........................................................ 52 ii

1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS Emerson Network Power Rack PDU Systems Emerson Network Power s Rack PDU Systems is a family of products that delivers power and management to connected IT equipment through a global and comprehensive offering including Basic, Managed and Adaptive Rack PDU systems. Each PDU type offers simplified installation and easy operation. Each type is compatible with standard rack enclosures. These Emerson Rack PDUs provide easy low-cost installation, simple relocation, security and proven design and performance. Emerson Rack PDUs can be set up with varying degrees of power-monitoring and management. When power or management requirements grow, the adaptive PDUs are scalable, enabling them to grow with the installation. Emerson PDUs are available for the entire spectrum of power needs of every type of rack equipment. Knurr DI-STRIP - Basic Rack PDU systems, provide a broad range of power distribution capacities and connectivity solutions in a robust package. Liebert MPH - Managed Rack PDUs with single-phase or three-phase capability for fixed power input/output with remote management support; one-piece unit with monitoring at the branch level and control at the receptacle level; available in rack-mount and zero U configurations. Liebert MPX - Adaptive Rack PDUs built with modular and scalable components that can be installed and reconfigured on-site to meet changing input and output power connectivity needs; with remote monitoring at the branch level and receptacle management and control at the receptacle level. 1.1 Safety and Agency Compliance Where a conflict arises between the following documents and statements made herein, the statements in this specification will govern. North American Units - 120V and 208V (Single-Phase and Three-Phase) UL 60950-1 Information Technology Equipment CAN/CSA-C22.2 No. 60950-1-03 Information Technology Equipment FCC, Title 47, Part 15 Subpart B for Class A operation as defined by ANSI Standard C63.4 ISTA Procedure 1A and 2A RoHS Compliant 1

Determining the Right Emerson PDU for Your Application 2.0 DETERMINING THE RIGHT EMERSON PDU FOR YOUR APPLICATION Each of the Rack PDU systems Emerson offers is well-suited for delivering power to sensitive, highcapacity, rack-mounted equipment. Determining which is best for a particular installation requires knowing the basic power requirements of the equipment in the rack, deciding on the acceptable or preferable level of monitoring and control and then balancing those considerations against site requirements. The Emerson Rack PDU product line includes models to fit all types of installations: new or established; stable or rapidly changing; contracting or expanding. Each type of installation may require any or all types of Emerson Rack PDUs. After determining your requirements, refer to the data and specifications for each product. 2

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 3.0 KNURR DI-STRIP PRODUCT SELECTION GUIDE - BASIC RACK PDUS 3.1 Overview - Basic Rack PDUs Part Number The Knurr DI-STRIP, a Basic Rack PDU system, provides a broad range of power distribution capacities and connectivity solutions in a robust package. The Knurr DI-STRIP includes an input power cord with appropriate input plug connection and hydraulic-magnetic branch rated overload protection as appropriate; basic rack mounting provisions are also provided. Knurr DI-STRIP Rack PDUs are available in rack mount and vertical zero-u form factors. The Knurr DI-STRIP fits most standard 600mm width network equipment rack enclosures. Product fit should be confirmed for each application. Table 1 Specifications - Knurr DI-STRIP INPUT OUTPUT Voltage Max Continuous kw* Phase Plug Receptacle/Socket Configuration 035351011 120 15 12 1.4 1 NEMA 5-15P (9) NEMA 5-15R Form Factor Rack mount or Vertical 035351021 120 15 12 1.4 1 NEMA 5-15P (12) NEMA 5-15R Vertical 035351031 120 15 12 1.4 1 NEMA 5-15P (18) NEMA 5-15R Vertical 035351041 120 20 1.9 1 NEMA L5-20P (9) NEMA 5-20 T-Slot Vertical 035351051 120 20 1.9 1 NEMA 5-20P (12) NEMA 5-20 T-Slot Vertical 035351061 120 20 1.9 1 NEMA L5-20P (12) NEMA 5-20 T-Slot Vertical 035351081 120 30 24 2.8 1 NEMA L5-30P (24) NEMA 5-20 T-Slot Vertical 035352011 208-240 20 3.3 1 NEMA L6-20P (9) IEC-C13 sockets Vertical 035352021** 208-240 20 3.3 1 IEC-C20 inlet (9) IEC-C13 sockets Rack mount or Vertical 035352031 208-240 20 3.3 1 NEMA L6-20P (12) IEC-C13 sockets Vertical 035352041** 208-240 20 3.3 1 IEC-C20 inlet (12) IEC-C13 sockets Vertical 035352051 208-240 30 24 4.9 1 NEMA L6-30P (4) IEC-C19 sockets Vertical 035352061 208-240 30 24 4.9 1 NEMA L6-30P (24) IEC-C13 sockets Vertical 035352078 208-240 30 24 4.9 1 NEMA L6-30P (20) IEC-C13 + (4) IEC-C19 sockets Vertical 035353021 120/208 20 5.7 3 NEMA L21-20P (18) IEC-C13 + (6) IEC-C19 sockets Vertical 035353031 120/208 20 5.7 3 NEMA L21-20P (27) IEC-C13 + (6) IEC-C19 sockets Vertical 035353041 120/208 20 5.7 3 NEMA L21-20P (27) 5-20 T-Slot Vertical 035353011 120/208 30 24 8.6 3 NEMA L21-30P (6) IEC-C19 sockets Vertical 035353051 120/208 30 24 8.6 3 NEMA L21-30P (18) IEC-C13 + (6) IEC-C19 sockets Vertical 035353061 120/208 30 24 8.6 3 NEMA L21-30P (27) IEC-C13 + (6) IEC-C19 sockets Vertical 035353078 208-240 60 48 17.3 3 IEC60309 (3 pole, 4 wire, 250VAC, blue) (2) IEC60309 035353088 208-240 42 34 24.4 3 (3 pole, 4 wire, 250VAC, blue) All input cords are 10 ft. (3m) in length. * Formulas used to calculate the kw: For single-phase: input voltage x max continuous amps = watts For three-phase: input voltage x max continuous amps x 1.73 = watts ** Knurr DI-STRIP output expansion modules require the use of a cord set for input power. (42) IEC-C13 + (6) IEC-C19 sockets (42) IEC-C13 + (6) IEC-C19 sockets Vertical Vertical 3

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 3.2 Basic Rack PDU Optional Cord Sets Output Cord Sets Output cord sets are available to support conversion of Rack PDU power output receptacles to alternative power output connections and to support Rack PDU output expansion capabilities. Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs. Knurr DI-STRIP output expansion modules are powered via an IEC-C20 input connection. These systems provide output expansion capabilities when connected to a receptacle on a separate Rack PDU. The output cord set for these systems includes an IEC-C19 receptacle to connect to the IEC-C20 plug on the output expansion Knurr DI-STRIP, a 3 ft. (1m) power cord and plug to connect to the Rack PDU receptacle providing power. Available plugs include: IEC-C20 to connect to an IEC-C19 Rack PDU receptacle. Input Cord Sets Input cord sets are available to support conversion of Rack PDU power input connections to alternative power input connections. Conversion of power input can be provided on Rack PDUs with L5-20P plug connections. The input cord set includes an L5-20R receptacle to connect to the L5-20P Rack PDU plug, a 1 ft. (0.3m) power cord and a 5-20P plug. Table 2 Cord sets - Knurr DI-STRIP Cord Sets Output Cord Sets - Power Output Conversion 539031G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3 ft. (1m) 539031G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m) 539031G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3 ft. (1m) 539031G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m) Output Cord Sets - Power Output Expansion 539031G7 Output Cord Set - Power Output Expansion - IEC-C20 to IEC-C19, 3 ft. (1m) 539031G8 Output Cord Set - Power Output Expansion - IEC-C20 to IEC-C19, 10 ft. (3m) 539031G3 Output Cord Set - Power Output Expansion - IEC-C14 to IEC-C19, 3 ft. (1m) 539031G4 Output Cord Set - Power Output Expansion - IEC-C14 to IEC-C19, 10 ft. (3m) Input Cord Sets - Power Input Conversion 539031G12 Input Cord Set - Power Input Conversion - L5-20R to 5-20P, 1 ft. (0.3m) 4

3.3 Dimensional Drawings - Basic Rack PDUs Figure 1 Knurr DI-STRIP 35351011 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.101.1 00/00 000000 www.knuerr.com 2.9" (73mm) 17.6" (447mm) FRONT VIEW 12.2" (311mm) REAR VIEW SIDE VIEW INPUT POWER Input Cord 10 ft. (3m) 5-15P (2-pole, 3-wire) Input Plug Phase Voltage (VAC) Max. Cont. 5-15P 1 120 15 12 OUTPUT POWER Bank Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 5-15R (9) 1 120 12 12 2.5" (63mm) 1.7" (44mm) 2" (50mm) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 2.5 lb. (1.1kg) 3. Shipping dimensions: 18.9" (480mm) L x 2.8" (71mm) W x 3.3" (84mm) D 4. Shipping weight: 2.8 lb. (1.3kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351011 Rev. 3 5

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 2 Knurr DI-STRIP 35351021 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.102.1 00/00 000000 www.knuerr.com 4.8" (123mm) 19.6" (497mm) FRONT VIEW 12.2" (311mm) REAR VIEW SIDE VIEW INPUT POWER Input Cord Input Plug Phase 10 ft. (3m) 5-15P (2-pole, 3-wire) Voltage (VAC) Max. Cont. 5-15P 1 120 15 12 OUTPUT POWER Bank Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 5-15R (9) 1 120 12 12 2.5" (63mm) 1.7" (44mm) 2" (50mm) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 2.7 lb. (1.2kg) 3. Shipping dimensions: 22.2" (565mm) L x 2.8" (70mm) W x 3.3" (85mm) D 4. Shipping weight: 3.1 lb. (1.4kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351021 Rev. 3 6

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 3 Knurr DI-STRIP 35351031 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.103.1 00/00 000000 www.knuerr.com 27.4" (697mm) FRONT VIEW 1.7" (44mm) 12.7" (323mm) 12.2" (311mm) 2.5" (63mm) REAR VIEW 2" (50mm) SIDE VIEW INPUT POWER 5-15P (2-pole, 3-wire) Input Input Cord Plug Phase 10 ft. (3m) OUTPUT POWER Bank Receptacle Type (Qty) Voltage (VAC) Max. Cont. 5-15P 1 120 15 12 Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 5-15R (18) 1 120 12 12 AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 27.4" (697mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.3 lb. (1.5kg) 3. Shipping dimensions: 42" (1065mm) L x 2.4" (60mm) W x 3" (75mm) D 4. Shipping weight: 3.8 lb. (1.72kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351031 Rev. 3 7

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 4 Knurr DI-STRIP 35351041 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.104.1 00/00 000000 www.knuerr.com 17.6" (447mm) FRONT VIEW REAR VIEW SIDE VIEW INPUT POWER Input Input Cord Plug Phase 10 ft. (3m) L5-20P (2 pole, 3 wire) Voltage (VAC) Max. Cont. L5-20P 1 120 20 OUTPUT POWER Bank Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 5-20R (9) 1 120 1.7" (44mm) 2" (50mm) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3 lb. (1.35kg) 3. Shipping dimensions: 26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.4 lb. (1.54kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351041 Rev. 3 8

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 5 Knurr DI-STRIP 35351051 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.105.1 00/00 000000 www.knuerr.com 4.8" (123mm) 19.6" (497mm) FRONT VIEW 12.2" (311mm) 2.5" (63mm) 1.7" (44mm) REAR VIEW 2" (50mm) SIDE VIEW INPUT POWER Input Input Cord Plug Phase 10 ft. (3m) OUTPUT POWER Bank Receptacle Type (Qty) 5-20P (2-pole, 3-wire) Voltage (VAC) Max. Cont. 5-20P 1 120 20 Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 5-20R (9) 1 120 AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.5 lb. (1.57kg) 3. Shipping dimensions: 26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.9 lb. (1.76kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351051 Rev. 3 9

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 6 Knurr DI-STRIP 35351061 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.106.1 00/00 000000 www.knuerr.com 4.8" (123mm) 19.6" (497mm) FRONT VIEW 12.2" (311mm) 2.5" (63mm) 1.7" (44mm) REAR VIEW 2" (50mm) SIDE VIEW INPUT POWER Input Cord Input Plug Phase 10 ft. (3m) OUTPUT POWER Bank Receptacle Type (Qty) L5-20P (2-pole, 3-wire) Voltage (VAC) Max. Cont. L5-20P 1 120 20 Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 5-20R (12) 1 120 AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.2 lb. (1.47kg) 3. Shipping dimensions: 24.6" (625mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.5 lb. (1.6kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35351061 Rev. 3 10

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 7 Knurr DI-STRIP 35351081 1.8" (46mm) 20A branch circuit breakers Branch 1 20A branch circuit breakers Branch 2 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.108.1 00/00 000000 www.knuerr.com 1.7" (44mm) 43.2" (1097mm) FRONT VIEW.6" (422mm) 24.5" (622mm) 2.1" (53mm) REAR VIEW 3.3" (85mm) SIDE VIEW L5-30P (2-pole, 3-wire) INPUT POWER Input Cord Input Plug Phase 10 ft. (3m) OUTPUT POWER Branch Receptacle Type (Qty) Voltage (VAC) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Branch 1 5-20R (12) 1 120 20 2 5-20R (12) 120 Max. Cont. L5-30P 1 120 30 24 AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 43.2" (447mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit weight: 7.51 lb. (3.4kg) 3. Shipping dimensions: 44.9" (1140mm) L x 2.8" (70mm) W x 6.3" (0mm) D 4. Shipping weight: 8.4 lb. (3.8kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 1 20 35351081 Rev. 4 11

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 8 Knurr DI-STRIP 35352011 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.201.1 00/00 000000 www.knuerr.com 17.6" (447mm) FRONT VIEW REAR VIEW SIDE VIEW INPUT POWER Input Input Cord Plug Phase 10 ft. (3m) L6-20P (2-pole, 3-wire) Voltage (VAC) Max. Cont. L6-20P 1 208-240 20 OUTPUT POWER Bank Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 IEC-C13 (9) 1 208-240 12 1.7" (44mm) 2" (50mm) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.2 lb. (1.4kg) 3. Shipping dimensions: 24.6" (625mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.4 lb. (1.5kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35352011 Rev. 3 12

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 9 Knurr DI-STRIP 35352021 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.202.1 00/00 000000 www.knuerr.com 17.6" (447mm) FRONT VIEW IEC-C20 inlet 2.5" (63mm) 12.2" (311mm) 2.9" (73mm) 1.7" (44mm) REAR VIEW 2" (50mm) SIDE VIEW AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) INPUT POWER Input Cord Input Phase 10 ft. (3m) * Requires a cordset OUTPUT POWER Bank IEC-C20 Inlet * Receptacle Type (Qty) Voltage (VAC) Max. Cont. 1 208-240 20 Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 IEC-C13 (9) 1 208-240 12 ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 1.5 lb. (0.7kg) 3. Shipping dimensions: 19" (483mm) L x 3" (75mm) W x 2.4" (60mm) D 4. Shipping weight: 1.7 lb. (0.8kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35352021 Rev. 3 13

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 10 Knurr DI-STRIP 35352031 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.203.1 00/00 000000 www.knuerr.com 19.6" (497mm) FRONT VIEW 4.8" (123mm) 12.2" (311mm) 2.5" (63mm) 1.7" (44mm) REAR VIEW 2" (50mm) SIDE VIEW L6-20P (2-pole, 3-wire) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) INPUT POWER Input Input Cord Plug Phase 10 ft. (3m) OUTPUT POWER Bank Receptacle Type (Qty) Voltage (VAC) Max. Cont. L6-20P 1 208-240 20 Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 IEC-C13 (12) 1 208-240 12 ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.4 lb. (1.5kg) 3. Shipping dimensions: 26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.7 lb. (1.68kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35352031 Rev. 3 14

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 11 Knurr DI-STRIP 35352041 IEC-C20 INLET 19.6" (497mm) FRONT VIEW 4.8" (123mm) 12.2" (311mm) 2.5" (63mm) DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 1.7" (44mm) 03.535.204.1 00/00 000000 www.knuerr.com REAR VIEW 2" (50mm) SIDE VIEW AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) INPUT POWER Bank Input Input Cord Plug Phase 10 ft. (3m) IEC-C20 inlet * * Requires a cordset OUTPUT POWER Receptacle Type (Qty) Voltage (VAC) Max. Cont. 1 208-240 20 Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 IEC-C13 (12) 1 208-240 12 ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 1.8 lb. (0.8kg) 3. Shipping dimensions: 22.6" (575mm) L x 2.4" (60mm) W x 3" (75mm) D 4. Shipping weight: 2.1 lb. (0.9kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35352041 Rev. 3 15

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 12 Knurr DI-STRIP 35352051 20A branch circuit breaker Branch 1 17.6" (447mm) FRONT VIEW REAR VIEW 1.8" (46mm) SIDE VIEW INPUT POWER Input Cord Input Plug Phase Voltage L6-30P (2-pole, 3-wire) Max. Cont. 10 ft. (3m) L6-30P 1 208-240 30 24 OUTPUT POWER Branch Receptacle Type (Quantity) Per Receptacle Type Phase Voltage (VAC) IEC-C19 (2) 208-240 IEC-C19 (2) 208-240 1 1 2 1 Max. Continuous Per Receptacle Per Branch 20 20 20A branch circuit breaker Branch 2 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.205.1 00/00 000000 www.knuerr.com 1.7" (44mm) 3.3" (85mm) AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage Temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit Dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 4.8lb. (2.2kg) 3. Shipping Dimensions: 29.0" (740mm) L x 6.3" (0mm) W x 2.7" (70mm) D 4. Shipping Weight: 5.5lbs (2.5kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35352051 Rev. 3

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 13 Knurr DI-STRIP 35352061 1.8" (46mm) 20A Branch Circuit Breaker 20A Branch Circuit Breaker BRANCH 1 BRANCH 2 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.206.1 00/00 000000 www.knuerr.com 43.2" (1097mm) FRONT VIEW.6" (422mm) 24.5" (622mm) REAR VIEW INPUT POWER Input Cord Input Plug Phase Voltage (VAC) Max Cont. 10 ft/3.0m L6-30P 1 208-240 30 24 OUTPUT POWER L6-30P (2 Pole, 3 Wire) Per Receptacle Type Receptacle Type Branch (Quantity) Phase Voltage (VAC) 1 2 IEC-C13 (12) IEC-C13 (12) 1 1 208-240 208-240 Max Cont. Per Receptacle Per Branch 12 20 12 20 SIDE VIEW AGENCY: CSA Tested to UL 60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F-131 F (0 C-55 C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F-140 F (-20 C - 60 C ) NOTES: 1. Unit Dimensions: 43.2" (1097mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit Weight: 6.8lbs (3.1kg) 3. Shipping Dimensions: 44.9" (1140mm) L x 2.8" (70mm) W x 6.3" (0mm) D 4. Shipping Weight: 7.7lbs (3.5kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 035352061 Rev. 3 1.7" (44mm) 2.1 (53mm) 3.3" (85mm) 17

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 14 Knurr DI-STRIP 35352078 6.7" (170mm) 21.3" (540mm) FRONT VIEW 20A branch circuit breaker TOP VIEW 20A branch circuit breaker 1.9" (47mm) L6-30P (2-pole, 3-wire) INPUT POWER BOTTOM VIEW Input Cord Input Plug Phase Voltage (VAC) Max. Cont. 10 ft. (3m) L6-30P 1 208-240 30 24 OUTPUT POWER Branch Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Branch 1 IEC-C13 (10) / IEC-C19 (2) 1 / 1 208-240 / 208-240 12 / 20 2 IEC-C13 (10) / IEC-C19 (2) 1 / 1 208-240 / 208-240 12 / 20 AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 21.3" (540mm) L x 6.7" (170mm) W x 1.9" (47mm) D 2. Unit weight: 15 lb. (6.8kg) 3. Shipping dimensions: 22.4" (570mm) L x 11.6" (295mm) W x 6.3" (0mm) D 4. Shipping weight: 18.3 lb. (8.3kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35352078 Rev. 3 18

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 15 Knurr DI-STRIP 35353011 1.8" [46mm 20A Branch Circuit Breaker Branch 1 20A Branch Circuit Breaker Branch 2 20A Branch Circuit Breaker Branch 3 DI STRIP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.301.1 00/00 000000 www.knuerr.com 27.4" (697mm) FRONT VIEW 24.5" (622mm) 0.9" (23mm) 1.7" (44mm) REAR VIEW 3.3" (85mm) INPUT POWER L21-30P (4 pole, 5 wire) Input Cord Input Plug Phase 10 ft. (3m) L21-30P 3 OUTPUT POWER Voltage (VAC) 120/208 Receptacle Type Per Receptacle Type Branch (Quantity) Phase Voltage (VAC) 1 IEC-C19 (2) 1 208-240 1 IEC-C19 (2) 1 208-240 1 IEC-C19 (2) 1 208-240 SIDE VIEW Max Cont. 30 24 Max Cont. Per Receptacle Per Branch 20 20 20 AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive, Storage Temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 27.4" (697mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit weight: 8 lb. (3.6kg) 3. Shipping dimensions: 64.6" (40mm) L x 2.8" (70mm) W x 6.3" (0mm) D 4. Shipping weight: 9.4 lb. (4.3kg) 5. All wiring is to be in compliance with national and local electric codes. 035353011 6. Mounting provisions provided. Rev. 3 19

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure Knurr DI-STRIP 35353021 Branch 1 Branch 3 DI STRIP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.302.1 00/00 000000 www.knuerr.com 1.7" (44mm) 39.3" (997mm) FRONT VIEW Branch 2 12.7" (322mm) 24.5" (622mm) 2.1" (53mm) REAR VIEW 2.0" (50mm) INPUT POWER L21-20P (4 pole, 5 wire) SIDE VIEW AGENCY: CSA Tested to UL 60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F-131 F (0 C to 55 C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C ) Input Cord Input Plug Phase Voltage (VAC) Max Cont. 10 ft/3.0m L21-20P 3 120/208 20 OUTPUT POWER Branch Receptacle Type (Quantity) Per Receptacle Type Phase Voltage (VAC) Max Cont. Per Receptacle Per Branch NOTES: 1. Unit Dimensions: 39.3" (997mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 5.8 lb. (2.63kg) 3. Shipping Dimensions: 40.4" (1027mm) L x 2.3" (60mm) W x 3.9" (100mm) D 4. Shipping Weight: 6.2 lb. (2.8kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 1 2 3 IEC-C13 (6)/IEC-C19 (2) IEC-C13 (6)/IEC-C19 (2) IEC-C13 (6)/IEC-C19 (2) 1 / 1 1 / 1 1 / 1 208-240/208-240 208-240/208-240 208-240/208-240 12 / 12 / 12 / 035353021 Rev. 3 20

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 17 Knurr DI-STRIP 35353031 Branch 3 Branch 2 DI STRIP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.303.1 00/00 000000 www.knuerr.com 1.7" (44mm) 51.1" (1297mm) FRONT VIEW 11.9" (301mm) Branch 1 36.8" (934mm) 2.5 (63mm) REAR VIEW 2.0" (50mm) SIDE VIEW INPUT POWER L21-20P (4 Pole, 5 Wire) Input Cord Input Plug Phase Voltage (VAC) Max Cont. 10 ft/3.0m L21-20P 3 120/208 20 AGENCY: CSA Tested to UL 60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C ) OUTPUT POWER Bank 1 2 3 Receptacle Type (Quantity) IEC-C13 (9) / IEC-C19 (2) IEC-C13 (9) / IEC-C19 (2) IEC-C13 (9) / IEC-C19 (2) Per Receptacle Type Phase 1 / 1 1 / 1 1 / 1 Voltage (VAC) 208-240/208-240 208-240/208-240 208-240/208-240 Max Cont. Per Receptacle Per Bank 12 / 12 / 12 / NOTES: 1. Unit Dimensions: 51.1" (1297mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 7.0 lb. (3.2kg) 3. Shipping Dimensions: 72.0" (1830mm) L x 2.4" (60mm) W x 3.5" (90mm) D 4. Shipping Weight: 7.5 lb. (3.4kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 035353031 Rev. 3 21

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 18 Knurr DI-STRIP 35353041 Branch 3 Branch 1 DI STRIP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.304.1 00/00 000000 www.knuerr.com 1.7" (44mm) 39.3" [997mm] FRONT VIEW 39.3" [997mm 12.3" (312mm) Branch 2 24.5" [622mm] 24.5" (622mm) 2.5 (63mm) REAR VIEW 2.0" (50mm) L21-20P (4 Pole, 5 Wire) INPUT POWER Input Cord Input Plug Phase Voltage (VAC) Max Cont. 10 ft/3.0m L21-20P 3 120/208 20 OUTPUT POWER Bank 1 2 3 Receptacle Type (Quantity) 5/20R (9) 5/20R (9) 5/20R (9) Per Receptacle Type Phase Voltage (VAC) 1 1 1 Max Cont. Per Receptacle Per Bank 120 120 120 SIDE VIEW AGENCY: CSA Tested to UL 60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C ) NOTES: 1. Unit Dimensions: 39.3" (997mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 5.7lb. (2.6kg) 3. Shipping Dimensions: 40.4" (1027mm) L x 2.3" (60mm) W x 4.0" (100mm) D 4. Shipping Weight: 6.3lb. (2.85kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 035353041 Rev. 3 22

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 19 Knurr DI-STRIP 35353051 20A branch circuit breaker Branch 1 20A branch circuit breaker Branch 2 20A branch circuit breaker Branch 3 1.7" (44mm) DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.305.1 00/00 000000 www.knuerr.com 51.1" (1297mm) FRONT VIEW 25.7" (652mm) 24.5" (622mm) 0.9" (23mm) 1.8" (46mm) REAR VIEW 3.3" (85mm) INPUT POWER L21-30P (4-pole, 5-wire) Input Cord Input Plug Phase Voltage (VAC) Max. Cont. SIDE VIEW AGENCY: CSA tested to UL 60950-1 RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) 10 ft. (3m) L21-30P 3 120 / 208 30 24 OUTPUT POWER Branch Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Branch 1 IEC-C13 (6) / IEC-C19 (2) 1 / 1 208-240/208-240 12 / 20 2 IEC-C13 (6) / IEC-C19 (2) 1 / 1 208-240/208-240 12 / 20 3 IEC-C13 (6) / IEC-C19 (2) 1 / 1 208-240/208-240 12 / 20 NOTES: 1. Unit dimensions: 51.1" (1297mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit weight: 10.1 lb. (4.6kg) 3. Shipping dimensions: 64.6" (40mm) L x 2.8" (70mm) W x 6.3" (0mm) D 4. Shipping weight: 11.6 lb. (5.25kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 35353051 Rev. 3 23

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 20 Knurr DI-STRIP 35353061 20A Branch Circuit Breaker 20A Branch Circuit Breaker 20A Branch Circuit Breaker Branch 1 Branch 2 Branch 3 1.7" (44mm) DI STRIP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 03.535.306.1 00/00 000000 www.knuerr.com 62.9" (1597mm) Front View 13.0" (330mm) 49.0" (1245mm) 0.9" (22mm) Rear View 1.8" (46mm) L21-30P (4 Pole, 5 Wire) INPUT POWER Input Cord Input Plug 10ft/3.0m L21-30P 3 120/208 30 24 OUTPUT POWER Branch 1 2 3 Receptacle Type (Quantity) Phase IEC-C13 (9) / IEC-C19 (2) IEC-C13 (9) / IEC-C19 (2) IEC-C13 (9) / IEC-C19 (2) Voltage (VAC) Per Receptacle Type Phase 1 / 1 1 / 1 1 / 1 Voltage (VAC) 208-240/208-240 208-240/208-240 208-240/208-240 Max Cont. Max Cont. Per Receptacle Per Branch 12 / 20 12 / 20 12 / 20 AGENCY: CSA Tested to UL 60950-1 3.3" RoHS Compliant (Reduction of Hazardous Substances) (85mm) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C ) NOTES: 1. Unit Dimensions: 62.9" (997mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit Weight: 11.0lb. (5.0kg) 3. Shipping Dimensions: 72.4" (1840mm) L x 2.8" (70mm) W x 6.3" (0mm) D 4. Shipping Weight: 12.7lb. (5.75kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 035353061 Rev. 3 24

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 21 Knurr DI-STRIP 35353078 6.7" (170mm) 20A Branch Circuit Breaker 20A Branch Circuit Breaker 20A Branch Circuit Breaker 63.0" (00mm) FRONT VIEW 20A Branch Circuit Breaker 20A Branch Circuit Breaker 20A Branch Circuit Breaker REAR VIEW OUTPUT POWER IEC 60309 (3 POLE, 4 WIRE, 250VAC, BLUE) INPUT POWER Input Cord Input Plug Phase Voltage (VAC) 10ft/3.0m IEC 60309 3 Branch 1 2 3 4 5 6 Receptacle Type (Quantity) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) 208-240 Phase 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 60 Per Receptacle Type Voltage (VAC) 208-240/208-240 208-240/208-240 208-240/208-240 208-240/208-240 208-240/208-240 208-240/208-240 SIDE VIEW Max. Cont. 48 Max. Cont. Per Receptacle Per Branch 12 / 20 12 / 20 12 / 20 12 / 20 12 / 20 12 / 20 1.9" (47mm) AGENCY: UL 60950-1, cul RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F-131 F (0 C to 55 C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 63.0" (00mm) L x 6.7" (170mm) W x 1.9" (47mm) D 2. Unit Weight: 32.8lbs (14.9kg) 3. Shipping Dimensions: 74.0" (1880mm) L x.3" (415mm) W x 6.3" (0mm) D 4. Shipping Weight: 38.4lb. (17.4kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 035353078 Rev. 5 25

Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 22 Knurr DI-STRIP 35353088 6.7" (170mm) 20A Branch Circuit Breaker 20A Branch Circuit Breaker 20A Branch Circuit Breaker 63" (00mm) FRONT VIEW 20A Branch Circuit Breaker 20A Branch Circuit Breaker 20A Branch Circuit Breaker REAR VIEW INPUT POWER Input Cord Input Plug Phase Voltage (VAC) 10ft/3.0m IEC 60309 3 OUTPUT POWER IEC 60309 (3 POLE, 4 WIRE, 250VAC, BLUE) 208-240 50 SIDE VIEW Max. Cont. 40 1.9" (47mm) AGENCY: UL 60950-1, cul RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F-131 F (0 C to 55 C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C) Input/ Branch 1/1 1/2 1/3 2/4 2/5 2/6 Receptacle Type (Quantity) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) Per Receptacle Type Phase 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 Voltage (VAC) 208-240/208-240 208-240/208-240 208-240/208-240 208-240/208-240 208-240/208-240 208-240/208-240 Max. Cont. Per Receptacle Per Branch 12 / 20 12 / 20 12 / 20 12 / 20 12 / 20 12 / 20 NOTES: 1. Unit dimensions: 63.0" (00mm) L x 6.7" (170mm) W x 1.9" (47mm) D 2. Unit Weight: 44.5lb. (20.2kg) 3. Shipping Dimensions: 74.0" (1880mm) L x.3" (415mm) W x 6.3" (0mm) D 4. Shipping Weight: 50lb. (22.7kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided. 035353088 Rev. 5 26

Liebert MPH Product Selection Guide - Managed Rack PDUs 4.0 LIEBERT MPH PRODUCT SELECTION GUIDE - MANAGED RACK PDUS 4.1 Overview - Managed Rack PDUs The Liebert MPH Managed Rack PDU system delivers power distribution, branch monitoring and receptacle control for IT devices. Liebert MPH Rack PDUs, with remote monitoring and/or control capabilities for power distribution at the load/equipment level, are designed to support the growth in rack electrical needs while meeting the new demands for remote power management. The Liebert MPH monitors electrical attributes of an individual Rack PDU, including real-time remote and (optional) local display of monitoring of aggregate and branch electrical parameters (status, thresholds, alarms) including voltage, amps, kw, and kw-hr. Liebert MPH features include branch load monitoring and control for continuous uptime and minimum disruptions; expandable monitoring interface providing simplified growth management; rugged construction; and the convenience of being factory-installed in the Knurr rack enclosure system. The Liebert MPH includes an input power cord with appropriate input plug connection and hydraulic-magnetic branch rated overload protection as appropriate; basic rack mounting provisions are also provided. Liebert MPH Managed Rack PDUs are available in rack mount and vertical zero-u form factors and are painted black. Liebert MPH Managed Rack PDUs / Liebert MPH-NB Systems (Branch Monitoring Only) Liebert MPH-NB series Rack PDUs provide local and remote monitoring of individual PDU volts, amps, watts, and kilowatt-hours. Liebert MPH Managed Rack PDUs / Liebert MPH-NC (Monitoring & Receptacle Control) Liebert MPH-NC series power strips provide the same features and functionality as the Liebert MPH-NB series with the additional capability of remote on/off control of individual receptacles. Local receptacle power on-off status is provided through an LED display. Liebert MPH Managed Rack PDUs ALL Liebert MPH Systems All Liebert MPH systems are provided with a factory-integrated Liebert RPC (Rack PDU Card RPC-1000) that provides Web-based remote monitoring via a direct IP network connection, Rack PDU Array interface connection to three additional Liebert MPH or Liebert MPX systems to allow viewing of up to four Rack PDUs on a single IP connection, an environmental sensor port, and a port for connection to the optional local display. Local display monitoring is provided via the optional RPC BDM (Basic Display Module) and integrated audible alarm. See 5.5 - Adaptive Rack PDU Optional Accessories for further details. Each Liebert MPH unit is provided with basic rack mounting provisions to meet a range of installation needs. The Liebert MPH fits most standard 600mm width network equipment rack enclosures. Product fit should be confirmed for each application. 27

Liebert MPH Product Selection Guide - Managed Rack PDUs 4.2 Specifications - Liebert MPH Table 3 Specifications - Liebert MPH Part Number Branch Monitoring Voltage (VAC) INPUT Max. Continuous kw* Phase Plug OUTPUT Receptacle/Socket Configuration Form Factor MPH-NBR09AXXC30 120 20 1.9 1 NEMA L5-20P (9) NEMA 5-20R T-Slot Rack mount MPH-NBV27AXXC30 120 20 1.9 1 NEMA L5-20P (27) NEMA 5-20R T-Slot Vertical MPH-NBR09AXXD30 120 30 24 2.8 1 NEMA L5-30P (9) NEMA 5-20R T-Slot Rack mount MPH-NBV27AXXD30 120 30 24 2.8 1 NEMA L5-30P (27) NEMA 5-20R T-Slot Vertical MPH-NBR09NXXE30 208-240 20 3.3 1 NEMA L6-20P (9) IEC-C13 Rack mount MPH-NBV27NXXE30 208-240 20 3.3 1 NEMA L6-20P (27) IEC-C13 Vertical MPH-NBR09NXXF30 208-240 30 24 4.9 1 NEMA L6-30P (9) IEC-C13 Rack mount MPH-NBV27NXXF30 208-240 30 24 4.9 1 NEMA L6-30P (27) IEC-C13 Vertical MPH-NBV27NOXF30 208-240 30 24 4.9 1 NEMA L6-30P (21) IEC-C13 & (6) IEC-C19 Vertical MPH-NBV27NXXJ30 208-240 30 24 8.6 3 NEMA L15-30P (27) IEC-C13 Vertical MPH-NBV27NOXJ30 208-240 30 24 8.6 3 NEMA L15-30P (21) IEC-C13 & (6) IEC-C19 Vertical MPH-NBV27AMXH30 120/208 30 24 8.6 3 NEMA L21-30P (15) IEC-C13, (6) NEMA 5-20 T-slot & Vertical (6) IEC-C19 MPH-NBV27AXXH30 120/208 30 24 8.6 3 NEMA L21-30P (27) NEMA 5-20R T-Slot Vertical MPH-NBV27ANXH30 120/208 30 24 8.6 3 NEMA L21-30P (21) IEC-C13 & (6) NEMA 5-20R T-Slot Vertical MPH-NBV27NXXH30 120/208 30 24 8.6 3 NEMA L21-30P (27) IEC-C13 Vertical MPH-NBV27NOXH30 120/208 30 24 8.6 3 NEMA L21-30P (21) IEC-C13 & (6) IEC-C19 Vertical Receptacle Control MPH-NCR09AXXC30 120 20 1.9 1 NEMA L5-20P (9) NEMA 5-20R T-Slot Rack mount MPH-NCV27AXXC30 120 20 1.9 1 NEMA L5-20P (27) NEMA 5-20R T-Slot Vertical MPH-NCR09AXXD30 120 30 24 2.8 1 NEMA L5-30P (9) NEMA 5-20R T-Slot Rack mount MPH-NCV27AXXD30 120 30 24 2.8 1 NEMA L5-30P (27) NEMA 5-20R T-Slot Vertical MPH-NCR09NXXE30 208-240 20 3.3 1 NEMA L6-20P (9) IEC-C13 Rack mount MPH-NCV27NXXE30 208-240 20 3.3 1 NEMA L6-20P (27) IEC-C13 Vertical MPH-NCR09NXXF30 208-240 30 24 4.9 1 NEMA L6-30P (9) IEC-C13 Rack mount MPH-NCV27NXXF30 208-240 30 24 4.9 1 NEMA L6-30P (27) IEC-C13 Vertical MPH-NCV27NOXF30 208-240 30 24 4.9 1 NEMA L6-30P (21) IEC-C13 & (6) IEC-C19 Vertical MPH-NCV27NXXJ30 208-240 30 24 8.6 3 NEMA L15-30P (27) IEC-C13 Vertical MPH-NCV27NOXJ30 208-240 30 24 8.6 3 NEMA L15-30P (21) IEC-C13 & (6) IEC-C19 Vertical (15) IEC-C13, MPH-NCV27AMXH30 120/208 30 24 8.6 3 NEMA L21-30P (6) NEMA 5-20 T-slot & Vertical (6) IEC-C19 MPH-NCV27AXXH30 120/208 30 24 8.6 3 NEMA L21-30P (27) NEMA 5-20R T-Slot Vertical MPH-NCV27ANXH30 120/208 30 24 8.6 3 NEMA L21-30P (21) IEC-C13 & (6) NEMA 5-20R T-Slot Vertical MPH-NCV27NXXH30 120/208 30 24 8.6 3 NEMA L21-30P (27) IEC-C13 Vertical MPH-NCV27NOXH30 120/208 30 24 8.6 3 NEMA L21-30P (21) IEC-C13 & (6) IEC-C19 Vertical All input cords are 10 ft. (3m) in length. * Formulas used to calculate the kw: For single-phase: input voltage x max continuous amps = watts For three-phase: input voltage x max continuous amps x 1.73 = watts 28

4.3 Model Number Configuration - Liebert MPH Example: MPH N B R 09 AX XC 30 Liebert MPH Product Selection Guide - Managed Rack PDUs Prefix: MPH Region: N = North American Type: B = Branch Monitoring C = Controlled Receptacles Mounting: V = Vertical R = Rack mount Output Power: Quantity Receptacles (Total): 09 or 27 Receptacle Type(s) 2 characters (each set): A = 5-20R T-Slot N = IEC-C13 O = IEC-C19 Note: Second character indicates a second receptacle type (X if no additional type chosen) Input Power: Plug Type: First character = X Second character: C=L5-20P D=L5-30P E=L6-20P F=L6-30P H = L21-30P J = L15-30P Cord Length: 30 = 3.0m (10 ft.) 29

Liebert MPH Product Selection Guide - Managed Rack PDUs 4.4 Managed Rack PDU Optional Cord Sets and Cable Restraints Output Cord Sets Output cord sets are available to support conversion of Rack PDU power output receptacles to alternative power output connections and to support Rack PDU output expansion capabilities. Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs. Input Cord Sets Input cord sets are available to support conversion of Rack PDU power input connections to alternative power input connections. Conversion of power input can be provided on Rack PDUs with L5-20P plug connections. The input cord set includes an L5-20R receptacle to connect to the L5-20P Rack PDU plug, a 1 ft. (0.3m) power cord and a 5-20P plug. Cable Restraints (Liebert MPH - Vertical Systems) Cable restraints are available to secure user equipment power cord connections to IEC-C13 receptacles. The Liebert MPH supports all vertical-mount models with IEC-C13 receptacles or a combination of IEC-C13 plus IEC-C19 receptacles. The cable restraint system includes three tie-down brackets for receptacle groups along with cable ties to secure individual input user equipment power cables. Table 4 Cord sets and cable restraints - Liebert MPH Cord Sets and Cable Restraints Output Cord Sets - Power Output Conversion 539031G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3.3 ft. (1m) 539031G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m) 539031G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3.3 ft. (1m) 539031G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m) Input Cord Sets - Power Input Conversion 539031G12 Input Cord Set - Power Input Conversion - L5-20P to 5-20P, 1 ft. (0.3m) Cable Restraints IEC-C13 (Liebert MPH - Vertical Systems) 11858KIT Cable Restraints - MPH Vertical Systems with IEC-C13 receptacles 30

4.5 Dimensional Drawings - Managed Rack PDUs Liebert MPH Product Selection Guide - Managed Rack PDUs Figure 23 Liebert MPH rack mount power strip Liebert MPH Power Distribution 1.7" [44mm PN: RPC-1000 HID Audible Alarm Silence FRONT VIEW 18.3" (465mm) RPC Communication Card Circuit Breaker 20 Amp 1.2" (32mm) 20A Input Breaker Input Plug REAR VIEW Output Receptacles 0.2" (6mm) 17.2" (438mm) L5-20P (2 Pole, 3 Wire) 7.0" (178mm) INPUT POWER Input Cord Input Plug Phase 1 5-20R (9) 1 Voltage (VAC) 10ft/3.0m L5-20P 1 120 OUTPUT POWER Branch Receptacle Type (Quantity) Per Receptacle Type Phase TOP VIEW 20 Voltage (VAC) Per Receptacle 120 Max Cont. Max Cont. MPH-NCR09AXXC30 Rev. 3 Per Branch 20 AGENCY: UL/C-UL Listed to UL60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIROMENTAL: Operating: 32 F-131 F (0 C-55 C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F-140 F (-20 C to 60 C) NOTES: 1. Unit Dimensions: 1.7" H x 7.0" D x 17.2" W (44mm x 178mm x 438mm) 2. Unit Weight: 7.5lb. (3.4kg) 3. Shipping Dimensions: 22.0" H x 9.0" D x 24.1" W (559mm x 228mm x 612mm) 4. Shipping Weight: 8.5lb. (3.9kg) 5. All wiring is to be in compliance with national and local electric codes. 1 2 3 4 5 6 7 8 9 31

Liebert MPH Product Selection Guide - Managed Rack PDUs Figure 24 Liebert MPH vertical power strip Branch 3 (9) 5-20R Branch 3 (9) 5-20R Branch 3 (9) 5-20R RPC Communication Card Branch 3 Branch 2 Branch 1 Branch 3 Branch 2 Branch 1 Circuit Breaker Circuit Breaker Circuit Breaker 20 Ampere 20 Ampere 20 Ampere Liebert MPH P ower Distribution PN: RPC-1000 HID 20A Branch Circuit Breakers FRONT VIEW 68.1" (1730mm) 1.9" (50mm) 3.4 (86mm) 3.4 (86mm) 12.3 (312mm) 12.3 (312mm) 0.2" (6mm) 1.2" (32mm) 0.99 (25mm) 9.2" (235mm) REAR VIEW Toolless Mounting Button (See Note 6) Vertical Mounting Bracket (See Note 6) 3.1" (80mm) INPUT POWER Input Cord Input Plug 10 ft/3.0m OUTPUT POWER Branch L5-20P Receptacle Type (Quantity) Phase 1 2.2" (57mm) Voltage (VAC) 120 Per Receptacle Type Phase Voltage (VAC) L5-20P (2 Pole, 3 Wire) SIDE VIEW Max Cont. 20 Max Cont. Per Receptacle Per Branch AGENCY: UL/C-UL Listed to UL60950-1 RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit Dimensions: 68.1" (1730mm) H x 3.1" (80mm) D x 1.9" (50mm) W 2. Unit Weight: 18lb. (8.2kg) 3. Shipping Dimensions: 72.2" (1962mm) H x 6.2" (159mm) D x 10.7" (273mm) W 4. Shipping Weight: 20lb. (9.1kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Only one mounting option required to be used at a time. Vertical mounting brackets and toolless buttons shown together for reference only. 1 2 3 5-20R (9) 5-20R (9) 5-20R (9) 1 1 1 120 120 120 20 20 20 MPH-NCV27AXXC30 Rev. 2 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 32

Liebert MPX - Adaptive Rack PDUs 5.0 LIEBERT MPX - ADAPTIVE RACK PDUS 5.1 Overview - Adaptive Rack PDUs The Liebert MPX Adaptive Rack PDU system delivers break-through flexibility, availability and total cost of ownership. The Liebert MPX enables users to respond to and manage changing rack power and management environments. The Liebert MPX provides users the ability to size their Rack PDU system to support initial requirements and then adapt as connectivity, capacity and/or functionality needs change. The Liebert MPX is based on a patent-pending design built on a power / communication bus and input/output power module strategy. The Liebert MPX Adaptive Rack PDU is composed of several key building blocks and support modules. The Liebert MPX is built on the MPX PRC (Power Rail Chassis) that distributes power and communications to all support modules, acts as a backplane to mount support modules and offers provisions to physically mount the Liebert MPX in a network rack. Input power is connected and delivered to the Liebert MPX system via the MPX PEM (Power Entry Module). Output power connectivity and communications management level is defined by the MPX BRM (Branch Receptacle Modules). MPX BRM power connectivity includes NEMA receptacles and IEC sockets. MPX BRM communications include Branch Monitoring and Receptacle Management versions. Network communications, sensor and/or local display interface are provided by the Liebert RPC (Rack PDU Card) that mounts in the MPX PEM. The Liebert RPC provides connection to an optional RPC BDM (Basic Display Module) for local status / alarm viewing. Module versions for North American and European applications are available. The Liebert MPX is provided as separate ship-loose modules for user on-site configuration. The Liebert MPX is designed for simple and quick configuration and reconfiguration. Preconfigured systems are available as an Special Feature Authorization (SFA) when ordered as factory installed in Knurr rack enclosure systems. The major Liebert MPX system components are described in the following sections: 5.2 - MPX PRC (Power Rail Chassis) 5.3 - MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord) 5.4 - MPX BRM (Branch Receptacle Module) 33

Liebert MPX - Adaptive Rack PDUs Figure 25 Liebert MPX 1880 and 1035 models and components MPX BRM Liebert RPC MPX PEM, Variable Capacity Liebert MPX, 1035mm Liebert PRC chassis MPX PEM, Fixed Capacity Liebert MPX, 1880mm Liebert PRC chassis MPX IPC RPC BDM 34

5.2 MPX PRC (Power Rail Chassis) Liebert MPX - Adaptive Rack PDUs The MPX PRC distributes power and communications to the installed Liebert MPX modules. The MPX PRC supports both single-phase power input up to 20A and three-phase up to 60A. It includes provisions to mount and secure an input power module (MPX PEM) and output receptacle modules (MPX BRM). It is available in lengths to accommodate typical 23U or 42U network racks: 1035mm (40.75 in.) for 23U and 1880mm (74 in.) for 42U. The MPX PRC includes zero-u mounting provisions that accommodate most rack designs. The MPX PRC is provided with cover / spacers to assist users with positioning for future MPX BRM module additions. Figure 26 MPX PRC (Power Rail Chassis) FRONT SIDE Section of MPX PRC Power Bus REAR SIDE Section of MPX PRC Communication Bus T-slots in the back of the MPX PRC (Power Rail Chassis) accept spring nuts for easy mounting Module Connector Slot 35

5.3 MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord) Liebert MPX - Adaptive Rack PDUs The MPX PEM provides input power to the Liebert MPX system and includes provisions for addition of the Liebert RPC (Rack PDU Card) to support remote and local communications. The MPX PEM is available in two versions: Variable Capacity and Fixed Capacity. The MPX PEM Variable Capacity version allows the user to select and change power input via different MPX IPCs. The MPX IPC includes cord, MPX PEM connector, and input plug. The MPX IPC is available in multiple versions supporting up to 30 amps including single-phase North American 120VAC and 208VAC and three-phase North American 208/120VAC connections. The MPX PEM Fixed Capacity version supports rated input capacities from 40 up to 60 amps with fixed cord and plug connections. All MPX PEMs include an audible over current alarm with local reset. One MPX PEM is required per Liebert MPX Rack PDU. Variable Capacity MPX PEMs are 220mm in length for application on both short (1035mm) and standard (1880mm) MPX PRC systems. Fixed Capacity systems are 266mm in length for application on standard (1880mm) MPX PRCs. 5.4 MPX BRM (Branch Receptacle Module) The MPX BRM provides output power distribution to user load equipment and remote management / monitoring of that equipment. The MPX BRM includes output receptacles (NEMA and IEC) and is overload-protected. The MPX BRM is available in two versions: Branch Monitoring and Receptacle Management. The MPX BRM Branch Monitoring version supports monitoring of its aggregate branch electrical and energy parameters (status, thresholds, and alarms) including voltage, amps, kw, and kw-hr. The MPX BRM Receptacle Management version supports monitoring of individual receptacle electrical and energy parameters (status, thresholds, and alarms) including voltage, amps, kw and kw-hr and supports on-off power control of individual receptacles, along with the aggregate branch monitoring provided on MPX BRM Branch Monitoring systems. MPX BRMs are hot-swappable to allow user installation without powering down the Liebert MPX system. Each MPX BRM includes a display that automatically assigns and displays a Branch identification number to the MPX BRM when added to an active Liebert MPX system. Each MPX BRM is overload-protected by 20 Amp branch-rated hydraulic magnetic circuit breakers that support UL60950 requirements. The breakers are protected from inadvertent tripping by requiring tool insertion to manually open and from accidental impact damage by a protection body/cover. MPX BRMs are offered in line-to-line and line-to-neutral power configurations. These configurations support different power input requirements and provide support for load balancing for three-phase input power systems. Up to three (3) MPX BRMs can be deployed on a Liebert MPX system utilizing the 1035mm MPX PRC for typical 23U racks and up to six (6) MPX BRMs for systems utilizing the 1880mm MPX PRC for typical 42U racks. All MPX BRMs are 266mm in length. 36

Liebert MPX - Adaptive Rack PDUs 5.5 Adaptive Rack PDU Optional Accessories 5.5.1 Cord Sets and Cable Restraints Output Cord Sets Output cord sets are available to support conversion of Rack PDU power output receptacles to alternative power output connections and to support Rack PDU output expansion capabilities. Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs. Cable Restraints (Liebert MPX Systems) Cable restraints are available to secure user equipment power cord connections to IEC-C13 receptacles. The Liebert MPX supports all models of the MPX BRM with IEC-C13 receptacles and includes individual cable restraint clips to support individual receptacles. Twelve restraint clips are provided per option. The Liebert MPX cable restraint supports most IEC-C14 plugs that connect to the IEC-C13 receptacles. Cord Sets and Cable Restraints Output Cord Sets - Power Output Conversion 539031G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3 ft. (1m) 539031G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m) 539031G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3 ft. (1m) 539031G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m) Cable Restraints IEC-C13 (Liebert MPX Systems) 0391029 Cable Restraints - MPX BRM with IEC-C13 receptacles (Set of 12) 5.5.2 Liebert RPC (RPC-1000) and Accessories The Liebert RPC (Rack PDU Card) is a network interface card that provides network connectivity to the Liebert Rack PDU family of products. The Liebert RPC can be installed in Adaptive and Managed versions of Liebert Rack PDUs to provide network monitoring and control capabilities. The Liebert RPC is a factory-installed standard feature of the Liebert MPH; it is an option for the Liebert MPX. In addition, the Liebert RPC serves as the integration point for several rack accessory products. Available options that connect to the card include the RPC BDM (Basic Display Module) and a temperature/humidity sensor. 37

5.5.3 Part Numbers for Liebert RPC and Accessories Liebert MPX - Adaptive Rack PDUs Liebert RPC (Rack PDU Card): RPC-1000 RPC BDM (Basic Display Module): RPC-BDM-1000 Liebert SN Integrated Environmental Sensors: SN-Z01 - Single Temperature Probe; 12 ft. (3.66m) length cable SN-Z02 - Three Temperature Probes; 17 ft. (5.18m) length cable SN-Z03 - Three Temperature Probes and Single Humidity Probe; 17 ft. (5.18m) length cable Liebert SN Modular Environmental Sensors: SN-T - Single Temperature Probe (1 probe) SN-TH - Single Temperature Probe and Single Humidity Probe (2 probes) SN-2D - Door Switch, 2 inputs (1 probe) SN-3C - Digital Input, 3 inputs (1 probe) 5.5.4 Ports on the Liebert RPC Figure 27 shows the four individual ports on the Liebert RPC. Each port is designed for only one type of connection. See the Liebert RPC user manual, SL-20825, for details on using these ports. Figure 27 Liebert RPC ports External Sensor port Display port Expansion/Management port LAN port 38

Liebert MPX - Adaptive Rack PDUs 5.5.5 Liebert RPC Capabilities and Benefits The Liebert RPC offers the following capabilities and benefits: Web Support The Liebert RPC delivers Web management and control to Liebert Rack PDU equipment. All authorized users will be able to view status information on their network. SNMP Support The Liebert RPC enables SNMP management of Liebert Rack PDU equipment. To integrate the card into an SNMP implementation, compile the Liebert Global Products MIB on your Network Management System (NMS). The Liebert Global Products MIB can be downloaded from: www.liebert.com Liebert Nform Utilizing the SNMP and Web technologies built into the Liebert RPC, Liebert Nform will centrally manage event notifications, access critical system information and manage the power delivered to your critical devices. A downloadable edition is available online at: nform.liebert.com Liebert SiteScan Web The Liebert RPC integrates with Liebert SiteScan Web software to monitor and analyze trends to ensure high-availability operation of critical facilities. For more information on Liebert SiteScan Web, visit the Web page at: sitescan.liebert.com 39

Liebert MPX - Adaptive Rack PDUs 5.5.6 RPC BDM Basic Display Module The RPC BDM is an optional device with an LCD for local viewing of status and alarms of up to four Liebert MPX or Liebert MPH PDUs. It connects to Liebert RPC with a factory-supplied cable that is 6.5 ft. (2m) long. The portable unit can be mounted on a wall for viewing particular units. The RPC BDM provides local display of electrical status for all connected Liebert MPX (and Liebert MPH) systems, MPX BRMs and individual receptacles, if the PDU version permits it. Information is accessed via a navigation switch on the RPC BDM. For model number and other details, refer to 5.5.3 - Part Numbers for Liebert RPC and Accessories and the Liebert RPC user manual, SL-20825, available at the Liebert Web site: www.liebert.com Figure 28 RPC BDM Jog Wheel on Top of Unit to Navigate Display Communication Port on Side of Unit Connects to Liebert RPC RPC BDM 5.5.7 Temperature/Humidity Sensor A temperature/humidity sensor is available to monitor conditions in the rack. The sensor mounts without tools. It connects to the Liebert RPC with a factory-supplied Ethernet cable and can be monitored over a network. Figure 29 Temperature/humidity sensor Sensor support Tool-less fastener Sensor Support base Sensor installed in rack Sensor Knurr frame member 40

Liebert MPX System Product Selection Guide 6.0 LIEBERT MPX SYSTEM PRODUCT SELECTION GUIDE 6.1 STEP 1 - Select an MPX PRC (Quantity x 1) To select an MPX PRC (Power Rail Chassis), refer to: Specifications - MPX PRC MPXPRC-V1035XXX: Input: Rack Fit: MPXPRC-V1880XXX: Input: Rack Fit: Max 8.6 kw, limited to 3 MPX BRM modules Single-Phase and Three-Phase 5-wire / 20-30 Amp / 120/208VAC Typical 23U, most 600mm wide Max 17.2 kw, limited to 6 MPX BRM modules Single-Phase and Three-Phase 5-wire / 20-60 Amp / 120/208VAC Typical 42U, most 600mm wide Model Number Configuration - MPX PRC Example: MPXPRC-V1035XXX Prefix: Mounting: MPXPRC V = Vertical Length: 1035 = Short (40.75"; 1035mm) 1880 = Standard (74"; 1880mm) Placeholder: XXX Liebert MPX with 1035mm Liebert PRC chassis Liebert MPX with 1880mm Liebert PRC chassis 41

6.2 STEP 2 - Select an MPX PEM / MPX IPC (Quantity x 1) Liebert MPX System Product Selection Guide To select an MPX PEM (Power Entry Module) and an MPX IPC (Input Power Cord) for a Variable Capacity MPX PEM system refer to: The appropriate table in 6.5 - System Selection Guide for the MPX PEM (Power Entry Module): Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30 Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30 Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30 The following information: Input Power MPX PEM Selection MPX IPC Input Plug 120VAC / 1-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXD30XXX L5-30P 208VAC / 1-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXF30XXX L6-30P 208VAC / 3-Phase / 30 AMP MPXPEM-NVAXXAXX MPXIPC-NXJ30XXX L15-30P 120/208VAC / 3-Phase / 20 Amp MPXPEM-NVAXXAXX MPXIPC-NXG30XXX L21-20P 120/208VAC / 3-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXH30XXX L21-30P Specifications - MPX PEM MPX PEM (Power Entry Module) MPXPEM-NVAXXAXX MPXPEM-NHBXXV30 MPXPEM-NHBXXX30 MPXPEM-NHBXXW30 Power Entry Module - Variable Capacity, North American, 120 or 208VAC single-phase and/or 208-240VAC three-phase input up to 30Amp Power Entry Module - Fixed Capacity, North American, 208-240VAC, three-phase 4-wire (L-L-L-G), 50Amp input, CS8365C plug, 10 ft. (3m) cord Power Entry Module - Fixed Capacity, North American, 208-240VAC, three-phase 4-wire (L-L-L-G), 60Amp input, IEC60309 Pin-Sleeve plug, 10 ft. (3m) cord Power Entry Module - Fixed Capacity, North American, 120/208VAC, three-phase 5-wire (L-L-L-N-G), 60Amp input, IEC60309 Pin-Sleeve plug, 10 ft. (3m) cord Model Number Configuration - MPX PEM Example: MPXPEM-NVAXXAXX Prefix: Region: MPXPEM N = North American Type: V = Variable Capacity H = Fixed Capacity Size: A = Base (220mm) Variable Capacity version B = Standard (266mm) Fixed Capacity version Communications: X = Future Use Input Power: Available Capacity or Plug Type: XA = 30 amps XV = 50 amps, 4-wire (CS8365C) XX = 60 amps, 4-wire (IEC60309) XW = 60 amps, 5-wire (IEC60309) Cord Length: XX = No integrated cord (Requires MPX IPC) 30 = 3.0m (10 ft.) MPX PEM, Fixed Capacity MPX PEM, Variable Capacity 42

Liebert MPX System Product Selection Guide Specifications - MPX IPC (MPX PEM Variable Capacity Systems ONLY) MPX IPC (Input Power Cord) 120VAC Single-Phase Input / Output Input Power Cord - North American, 30Amp - 120VAC - Single-Phase; MPXIPC-NXD30XXX NEMA L5-30P Locking plug; 10 ft. (3m) length cord 208VAC Single-Phase Input / Output Input Power Cord - North American, 30Amp - 208-240VAC - Single-Phase; MPXIPC-NXF30XXX NEMA L6-30P Locking plug; 10 ft. (3m) length cord 208VAC Three-Phase Input / 208VAC Single-Phase Output Input Power Cord - North American, 30Amp - 208-240VAC - Three-Phase, 4-wire; MPXIPC-NXJ30XXX NEMA L15-30P Locking plug; 10 ft. (3m) length cord 208VAC Three-Phase Input / 120/208VAC Single-Phase Output Input Power Cord - North American, 20Amp - 120/208VAC - Three-Phase; MPXIPC-NXG30XXX NEMA L21-20P Locking plug; 10 ft. (3m) length cord Input Power Cord - North American, 30Amp - 120/208VAC - Three-Phase; MPXIPC-NXH30XXX NEMA L21-30P Locking plug; 10 ft. (3m) length cord Model Number Configuration - MPX IPC (MPX PEM Variable Capacity Systems ONLY) Example: MPXIPC-NXG30XXX Prefix: Region: MPXIPC N = North American Input Power and Connection: Plug Type: XD = L5-30P XF = L6-30P XJ = L15-30P XG = L21-20P XH = L21-30P Cord Length: 30 = 3.0m (10 ft.) Placeholder: XXX MPX PEM, Variable Capacity MPX IPC 43

Liebert MPX System Product Selection Guide 6.3 STEP 3 - Select an MPX BRM To select an MPX BRM (Branch Receptacle Module), refer to: The appropriate table in 6.5 - System Selection Guide for the MPX PEM (Power Entry Module): Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30 Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30 Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30 The following MPX BRM quantity definitions: MPX PRC selected Single-Phase Input Three-Phase Input MPXPRC-V1035XXX 3 MPX BRM modules maximum 1 x BRM per Lx-Lx* (total 3 max) MPXPRC-V1035XXX 6 MPX BRM modules maximum 2 x BRM per Lx-Lx* (total 6 max) * Required for phase load balancing If needed, refer to the MPX BRM specifications in Table 9 Model Number Configuration - MPX BRM Example: MPXBRM-NRBD4O31 Prefix: Region: MPXBRM N = North American Type: B = Branch Monitoring R = Receptacle Management Size and OL Protection: Size: B = Standard (266mm) Voltage Rating and OL Protection: A = 120V/20A D = 208-240V/20A Output Power: Quantity Receptacles: 4, 6 Receptacle Type: A = 5-20R T-slot N = IEC-C13 O = IEC-C19 Phase Configuration: 1N = L1-N 2N = L2-N 3N = L3-N 12 = L1-L2 23 = L2-L3 31 = L3-L1 MPX BRM 44

Liebert MPX System Product Selection Guide 6.4 STEP 4 - Select Communication Options Choose from the following options for the Liebert MPX: Liebert RPC (Rack PDU Card) part number: RPC-1000 RPC BDM (Basic Display Module) part number: RPC-BDM-1000 Liebert SN Integrated and Modular Environmental Sensor part numbers: Integrated Sensors SN-Z01 - Single Temperature Probe; 12 ft. (3.66m) length cable SN-Z02 - Three Temperature Probes; 17 ft. (5.18m) length cable SN-Z03 - Three Temperature Probes and Single Humidity Probe; 17 ft. (5.18m) length cable Modular Sensors SN-T - Single Temperature Probe (1 probe) SN-TH - Single Temperature Probe and Single Humidity Probe (2 probes) SN-2D - Door Switch, 2 inputs (1 probe) SN-3C - Digital Input, 3 inputs (1 probe) The Liebert RPC is required for the other two options, the RPC BDM and Liebert SN integrated sensor. RPC BDM Liebert RPC Liebert SN (Integrated Sensor) Liebert SN (Modular Sensor) 45

6.5 System Selection Guide Table 5 Liebert MPX System Product Selection Guide Use the appropriate table as a guide to select components that are compatible with each MPX PEM: Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30 Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30 Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30 MPX PEM Part Number MPXPEM-NVAXXAXX* Selections for Power Entry Module MPXPEM-NVAXXAXX Module Voltage 120/208 or 208-240 * No fixed cord (requires MPX IPC) Compatible MPX PRC for given MPX PEM: Voltages Supported Max. Continuous Input Connection 30 24 Variable Max. Continuous Max. # MPX BRMs Supported Input Phases Single-Phase or Three-Phase depending on the MPX IPC selection Phase Configuration Module Length (mm) 220 Overall Length MPXPRC-V1035XXX 120/208 3 Single-Phase 1035mm, 23U 60 48 MPXPRC-V1880XXX or 208-240 6 & Three-Phase 1880mm, 42U Compatible MPX IPC for given MPX PEM: Voltages Supported Max. Continuous Input Plug Phase Configuration Cord Length ft. (m) MPXIPC-NXD30XXX 120 30 24 NEMA L5-30P L1-N-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 Receptacle Management MPXBRM-NRBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 Max. Continuous Cord Length ft. (m) Compatible MPX IPC Voltages Phase for given MPX PEM: Supported Input Plug Configuration MPXIPC-NXF30XXX 208-240 30 24 NEMA L6-30P L1-L2-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Branch Monitoring Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) MPXBRM-NBBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 Receptacle Management MPXBRM-NRBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 46

Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX (continued) Compatible MPX IPC for given MPX PEM: Voltages Supported Max. Continuous Liebert MPX System Product Selection Guide Input Plug Phase Configuration Cord Length ft. (m) MPXIPC-NXJ30XXX 208-240 30 24 NEMA L15-30P L1-L2-L3-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 Compatible MPX IPC for given MPX PEM: Voltages Supported Max. Continuous Input Plug Phase Configuration Cord Length ft. (m) MPXIPC-NXG30XXX 120/208 20 NEMA L21-20P L1-L2-L3-N-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Branch Monitoring Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) MPXBRM-NBBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NBBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NBBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NBBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NRBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NRBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NRBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 47

Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX (continued) Compatible MPX IPC for given MPX PEM: Voltages Supported Max. Continuous Liebert MPX System Product Selection Guide Input Plug Phase Configuration Cord Length ft. (m) MPXIPC-NXH30XXX 120/208 30 24 NEMA L21-30P L1-L2-L3-N-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NBBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NBBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NBBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NRBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NRBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NRBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 48

Liebert MPX System Product Selection Guide Table 6 Selections for Power Entry Module MPXPEM-NHBXXV30 MPX PEM Part Number Module Voltage Max. Continuous MPXPEM-NHBXXV30 208-240V 50 40 Input Connection CS83665C 3-PH, 4-Wire Input Phases Module Length (mm) L1-L2-L3-G 266 Compatible MPX PRC for given MPX PEM: Voltages Supported Max. Continuous Max. # MPX BRMs Supported Phase Configuration Overall Length MPXPRC-V1035XXX 120/208 3 Single-Phase 1035mm, 23U 60 48 MPXPRC-V1880XXX or 208-240 6 & Three-Phase 1880mm, 42U Compatible MPX BRM for given MPX PEM: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 49

Liebert MPX System Product Selection Guide Table 7 Selections for Power Entry Module MPXPEM-NHBXXX30 MPX PEM Part Number Module Voltage Max. Continuous MPXPEM-NHBXXX30 208-240V 60 48 Input Connection IEC60309 3-PH, 4-Wire Input Phases Module Length (mm) L1-L2-L3-G 266 Compatible MPX PRC for given MPX PEM: Voltages Supported Max. Continuous Max. # MPX BRMs Supported Phase Configuration Overall Length MPXPRC-V1035XXX 120/208 3 Single-Phase 1035mm, 23U 60 48 MPXPRC-V1880XXX or 208-240 6 & Three-Phase 1880mm, 42U Compatible MPX BRM for given MPX PEM: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 50

Liebert MPX System Product Selection Guide Table 8 Selections for Power Entry Module MPXPEM-NHBXXW30 MPX PEM Part Number Module Voltage Max. Continuous MPXPEM-NHBXXW30 208-240V 60 48 Input Connection IEC60309 3-PH, 5-Wire Input Phases Module Length (mm) L1-L2-L3-N-G 266 Compatible MPX PRC for given MPX PEM: Voltages Supported Max. Continuous Max. # MPX BRMs Supported Input Phases Overall Length MPXPRC-V1035XXX 120/208 3 Single-Phase 1035mm, 23U 60 48 MPXPRC-V1880XXX or 208-240V 6 & Three-Phase 1880mm, 42U Compatible MPX BRM for given MPX PEM: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NBBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NBBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NBBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NRBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NRBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NRBD6N12 208-240V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N23 208-240V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N31 208-240V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O12 208-240V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O23 208-240V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O31 208-240V 20 (4) IEC-C19 L3-L1 266 51

6.6 Specifications for Liebert MPX Components Liebert MPX System Product Selection Guide Table 9 Specifications - MPX BRM MPX BRM (Branch Receptacle Module) Single-Phase Liebert MPX System (MPX PEM) Input Selections Phase L1 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A1N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Line L1 to Neutral (120VAC) Receptacle Management Support MPXBRM-NRBA6A1N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Line L1 to Neutral (120VAC) Line L1 to L2 (208VAC) Output Branch Monitoring Support MPXBRM-NBBD6N12 Branch Monitoring, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC) MPXBRM-NBBD4O12 Branch Monitoring, (4) IEC-C19 receptacles; Line L1 to L2 (208-240VAC) Receptacle Management Support MPXBRM-NRBD6N12 Receptacle Management, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC) MPXBRM-NRBD4O12 Receptacle Management, (4) IEC-C19 receptacles; Line L1 to L2 (208-240VAC) Three-Phase Liebert MPX System (MPX PEM) Input Selections Line L1 to L2 (208VAC) or Phase L1 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A1N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L1 to Neutral (120VAC) MPXBRM-NBBD6N12 Branch Monitoring, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC) MPXBRM-NBBD4O12 Branch Monitoring, (4) IEC-C19 receptacles Line L1 to L2 (208-240VAC) Receptacle Management Support MPXBRM-NRBA6A1N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L1 to Neutral (120VAC) MPXBRM-NRBD6N12 Receptacle Management, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC) MPXBRM-NRBD4O12 Receptacle Management, (4) IEC-C19 receptacles Line L1 to L2 (208-240VAC) Line L2 to L3 (208VAC) or Phase L2 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A2N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L2 to Neutral (120VAC) MPXBRM-NBBD6N23 Branch Monitoring, (6) IEC-C13 receptacles; Line L2 to L3 (208-240VAC) MPXBRM-NBBD4O23 Branch Monitoring, (4) IEC-C19 receptacles Line L2 to L3 (208-240VAC) Receptacle Management Support MPXBRM-NRBA6A2N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L2 to Neutral (120VAC) MPXBRM-NRBD6N23 Receptacle Management, (6) IEC-C13 receptacles Line L2 to L3 (208-240VAC) MPXBRM-NRBD4O23 Receptacle Management, (4) IEC-C19 receptacles Line L2 to L3 (208-240VAC) Line L3 to L1 (208VAC) or Phase L3 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A3N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L3 to Neutral (120VAC) MPXBRM-NBBD6N31 Branch Monitoring, (6) IEC-C13 receptacles; Line L3 to L1 (208-240VAC) MPXBRM-NBBD4O31 Branch Monitoring, (4) IEC-C19 receptacles Line L3 to L1 (208-240VAC) Receptacle Management Support MPXBRM-NRBA6A3N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L3 to Neutral (120VAC) MPXBRM-NRBD6N31 Receptacle Management, (6) IEC-C13 receptacles Line L3 to L1 (208-240VAC) MPXBRM-NRBD4O31 Receptacle Management, (4) IEC-C19 receptacles Line L3 to L1 (208-240VAC) 52

Liebert MPX System Product Selection Guide 6.7 Dimensional Drawings - Adaptive Rack PDUs Figure 30 Liebert MPX MPXPRC-1035mm mixed modules MPX-PRC cover/spacer 2.9" (75mm) 4.1" (104mm) 2.9" (75mm) 10.5" (266mm) MPX-BRM circuit breaker protection body MPX-PRC (Power Rail Chassis) 10.5" (266mm) 40.6" (1035mm) TOP VIEW MPX-BRM (Branch Receptacle Modules) SIDE VIEW 10.5" (266mm) 8.7" (220mm) MPX-PEM (Power Entry Module) Input power cord (variable) 4.1" (104mm) NOTES: 1. Dimensional view of 1035mm MPX-PRC application. 2. Representative module mix may not reflect user selection. 3. Operating temperature: 41 F to 131 F (5 C to 55 C) 4. Storage temperature: -13 F to 185 F (-25 C to 85 C ) MPX-MIXMOD1035 Rev. 0 53

Liebert MPX System Product Selection Guide Figure 31 Liebert MPX MPXPRC-1880mm mixed modules MPX-PRC cover/spacer 2.9" (75mm) 4.1" (104mm) 2.9" (75mm) END VIEW 10.5" (266mm) 10.5" (266mm) 4.1" (104mm) MPX-PRC (Power Rail Chassis) 10.5" (266mm) 10.5" (266mm) 74" (1880mm) TOP VIEW MPX-BRM (Branch Receptacle Modules) SIDE VIEW 10.5" (266mm) 10.5" (266mm) 10.5" (266mm) MPX-PEM (Power Entry Module) MPX-BRM circuit breaker protection body Input power cord (fixed) 4.1" (104mm) NOTES: 1. Dimensional view of 1880mm MPX-PRC application. 2. Representative module mix may not reflect user selection. 3. Operating temperature: 41 F to 131 F (5 C to 55 C) 4. Storage temperature: -13 F to 185 F (-25 C to 85 C ) MPX-MIXMOD1880 Rev. 1 54

Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, the global leader in enabling business-critical continuity, ensures network resiliency and adaptability through a family of technologies including Liebert power and cooling technologies that protect and support business-critical systems. Liebert solutions employ an adaptive architecture that responds to changes in criticality, density and capacity. Enterprises benefit from greater IT system availability, operational flexibility and reduced capital equipment and operating costs. While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 2009 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-20828_REV1_02-11 Technical Support / Service Web Site www.liebert.com Monitoring liebert.monitoring@emerson.com 800-222-5877 Outside North America: +00800 1155 4499 Single-Phase UPS & Server Cabinets liebert.upstech@emerson.com 800-222-5877 Outside North America: +00800 1155 4499 Three-Phase UPS & Power Systems 800-543-2378 Outside North America: 614-841-6598 Environmental Systems 800-543-2778 Outside the United States: 614-888-0246 Locations United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy +39 049 9719 111 Fax: +39 049 5841 257 Asia 29/F, The Orient Square Building F. Ortigas Jr. Road, Ortigas Center Pasig City 05 Philippines +63 2 687 6615 Fax: +63 2 730 9572 Emerson Network Power. The global leader in enabling Business-Critical Continuity AC Power Connectivity DC Power Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant Power Switching & Controls Precision Cooling EmersonNetworkPower.com Racks & Integrated Cabinets Services Surge Protection Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks of Emerson Electric Co. or one of its affiliated companies. 2010 Emerson Electric Co.