Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing



Similar documents
Agilent 4339B/4349B High Resistance Meters

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

Electrical Safety Tester Verification

High Voltage Power Supplies

User's Guide. True RMS Industrial Multimeter

5000V Graphical Megohmmeter Model 5070

1.44 kw Programmable DC Power Supplies XLN Series

DC Electronic Loads 8500 series

Multi-Range Programmable DC Power Supplies 9115 Series

MIT510/2, MIT520/2 and MIT1020/2

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Electrical Safety Tester

Physical Specifications (Custom design available.)

Multi-Range Programmable DC Power Supplies 9115 Series

OPERATION AND SERVICE MANUAL. Model 1305, 2503, 2510, 2550

High Power Programmable DC Power Supplies PVS Series

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Agilent 4338B Milliohm Meter

Product Information Sheet UH36 Hi Pot Tester

Quick Connect. quick - simple - efficient.

Dielectric Withstand Testing in a Production Environment

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Product Information Sheet UH28CS-12kV Hi Pot Tester

Uninterruptible Power Supply

NIM High Voltage Power Supplies

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Handheld portable appliance testers

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Voltech DC1000. Precision DC Bias Current Source

Tutorial on Safety Standard Compliance For Hipot Testing

Low and High Voltage Power Supplies

AutoRanging Digital MultiMeter

T Substation Maintenance and Commissioning Test Equipment

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Temperature & Humidity SMS Alert Controller

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Centro-Matic Automatic Lubrication Systems System Controls

Why Buy HVI VLF Products?

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

User's Guide. Integrating Sound Level Datalogger. Model Introduction

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Series 90 Series 90HV

MAJORSINE Power Inverter

User s Manual Before using the inverter, you need to read and save the safety instructions.

Multi-Function Ground

Wahl C50 Calibrator FEATURES

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Hand-held thermometer Model CTH7000

Research RF Sputtering Packages

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Mobile Communications DC Sources W

Manual Ranging MultiMeter

Agilent E3633A and E3634A DC Power Supplies

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Model #: SMART2200CRMXL

Fluke 1650B Series Multifunction Installation Testers

LOXONE 12 Channel Amplifier

Measuring Insulation Resistance of Capacitors

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Intersection Preassembled 19-inch Rack

TMS TANK MANAGEMENT SYSTEM

BITMAIN. APW PSU Series User Guide

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

KNC Model 3666 Automatic Pressure Calibration System

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

NC-12 Modbus Application

SMART SENSOR COLLECTION

PowerGem Pro Uninterruptible Power Supply

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Insulation resistance testing. A complete solution for every person.

Incubator with mechanical convection

RLC Series Resonance

rigel 288 Electrical Medical Safety Analyser Key Features Applications

DCS Series 1 kw, 1.2 kw, & 3 kw

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Voltage Regulator SPAU 341 C. Product Guide

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

World Leader in HV Testing Technology

HVDP. High Voltage Dynamic Power supply/source. 1, 2.5 and 5kW Output DC + Sine Wave Family

KONSTANTER SPL / SPL Programmable Electronic Load

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

/ LCR HiTESTER Components measuring instruments

High voltage tester HA 1800 Table-top device

4-Channel Thermometer / Datalogger

±15 V Current-Limited Power Supply

FIREDEX Conventional Fire Panels

Current Monitoring Kit

Transcription:

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed.

ENHANCED GRAPHIC LCD The enhanced graphic liquid crystal display on the Hypot III and the HYAMP III provides the operator with complete test setup and results in an easy-to-use interface. The graphic LCD makes testing safer, easier and more reliable than ever before. (Above display is shown at actual size.) Clear test parameters can be displayed on a single screen Configurable test result screen can be set up to show detailed test results The test result screen can be set up to show a simple PASS/FAIL indication. INTERCONNECT CAPABILITIES A COMPLETE MID-RANGE SYSTEM TO MEET THE MOST COMMON ELECTRICAL SAFETY COMPLIANCE TESTS With its 2U 1/2 rack mount cabinet design the Hypot III family of products can be interconnected to the HYAMP III, model 3130 Ground Bond tester that is also designed in a 2U 1/2 rack mount style cabinet. These two instruments can then be rack mounted side by side in a single 19 2U rack space. The interconnect capability of these two instruments also provides a single DUT connection and automates the test sequence or sequences chosen by the operator such as AC Hipot, DC Hipot, IR test and Ground Bond test.

USER-FRIENDLY FEATURES Tamper Proof Front Panel Controls To Limit User Access User Selectable Output Voltage & Frequency PLC Remote Inputs & Outputs Built-In Security Settings Multiple Test Memories & Steps Electronic Dwell Setting No Load Setup Of Voltage Current Minimum & Maximum Trip Settings NEW TO HYPOT III & HYAMP III FEATURE Enhanced graphic LCD BENEFIT The enhanced graphic LCD provides the operator with an advanced user-interface. This backlit graphic display makes viewing and interpreting test results and data easier than ever before. The LCD can display text and symbols eliminating the need to decipher abbreviations. FEATURE Built-in verification menu BENEFIT Regular verification is required by some agencies to validate that the instrument is functioning correctly. The verification menu, by prompting the user through the correct steps, allows for quick and easy validation. This built-in feature eliminates the additional cost of having to purchase an external box for verification. FEATURE Remote Safety Interlock BENEFIT The Remote Safety Interlock prevents the high voltage from being activated without the interlock enabled. The interlock works as a safety feature by using a set of contacts to enable or disable the instrument s high voltage output. If the interlock contacts open during a test the high voltage output is shut down. FEATURE 2U 1/2 Rack Mount BENEFIT Hypot III and HYAMP III are both smaller than their predecessors. Both instruments come in a 2U 1/2 rack mount space which allow them to be rack mounted side by side in a single 19 2U rack space. NEW TO HYPOT III FEATURE Exclusive SmartGFI function BENEFIT The patent pending SmartGFI provides maximum operator protection to the user. If the circuit detects excessive leakage to the ground it shuts down the high voltage in less than 1 millisecond. SmartGFI is automatically activated if the DUT is not grounded so that the operator does not need to make the decision whether to activate the SmartGFI. FEATURE Max output current 20 ma AC and 7.5 ma DC BENEFIT Hypot III is a true hipot tester with enough output current to test capacitive loads in AC mode and allows the instrument to comply with the UL 120 K ohm requirements. FEATURE Switchable Floating and Grounded Return BENEFIT This feature is included within the software of the instrument. The instrument automatically detects if the DUT is floating or connected to Earth Ground. If the DUT is grounded the smart GFI circuit turns off the GFI detector. If the DUT is floating the GFI circuit is enabled. FEATURE Digitally controlled arc detection system BENEFIT The arc detection system allows the operator to select whether low-level arcs should be detected and provides the operator with the ability to digitally select and program multiple sensitivity levels. FEATURE Built-in adjustable Continuity test mode BENEFIT Hypot III meets ground continuity test requirements called out by UL and other safety agencies. FEATURE Electronic ramping (up & down) BENEFIT Electronic ramping provides a gradual and timed method to increase or decrease output voltage to the DUT effectively minimizing any damage from quick high voltage changes to sensitive DUTs. FEATURE Resistance Range of 1-9999 MΩ BENEFIT Model 3670 AC/DC/IR includes an increased maximum resistance limit, which will allow for increased resistance measurement of the insulation of a DUT.

HYPOT III SPECIFICATIONS Models 3605 AC, 3665 AC/DC and 3670 AC/DC/IR INPUT VOLTAGE 115/230 V selectable ± 10% variation FREQUENCY 50-60 Hz ± 5% FUSE 115 VAC, 230 VAC - 3.15 A fast acting 250 VAC DIELECTRIC WITHSTAND TEST MODE Rating: AC 0-5000 V, 20 ma DC 0-6000 V, 7.5 ma Regulation: ± (1% of output + 5 V) VOLTAGE Rating: 0 V - Max output rating, 10 V/step Accuracy: ± (2% of setting + 5 V) (relative to displayed output) Can be adjusted during operation via UP and DOWN arrow keys. AC models: 50/60 Hz selectable FREQUENCY AC & DC models: DC and 50/60 Hz selectable WAVE FORM Sine wave Distortion: < 2% THD RIPPLE 5% at 6 KV DC/7.5 ma, Resistive Load DWELL TIME AC: 0 and 0.3-999.9 secs, 0.1 sec/step DC: 0 and 0.4-999.9 secs (0 = Constant) RAMP TIMER Range: Ramp-Up: 0.1-999.9 sec Ramp-Down: AC 0.0-999.9 sec DC 1.0-999.9 sec 0=OFF Resolution: 0.1 sec FAILURE AC Max. Limit: 0.00-20.00 ma, 0.01 ma/step S Min. Limit: 0.0-9.999 ma, 0.001 ma/step (0 = OFF) Accuracy: ± (2% of setting + 2.0 ma) DC Max. Limit: 0.00-7.50 ma, 0.001 ma/step Min. Limit: 0.0-999.9 µa, 0.0001 ma/step (0 = OFF) Accuracy: ± (2% of setting + 2 ma) DISCHARGE TIME 200 ms The maximum capacitive load vs. output voltage: 0.20 µf < 1 KV 0.050 µf < 4 KV 0.10 µf < 2 KV 0.040 µf < 5 KV 0.06 µf < 3 KV 0.015 µf < 6 KV VOLTAGE Range: 0.00-5.00 KV AC 0.00-6.00 KV DC Resolution: 0.01 KV Accuracy: ± (2% of reading + 0.01 KV) CURRENT Auto Range AC Range 1: 0.000 ma - 3.500 ma Resolution: 0.001 ma Range 2: 3.00-20.00 Resolution: 0.01 ma DC Range 1: 0.0 µa - 350.0 µa Resolution: 0.1 µa Range 2: 0.300 ma - 3.500 ma Resolution: 0.001 ma Range 3: 3.00 ma - 7.50 ma Resolution: 0.01 ma ACCURACY All Ranges: ± (2% of reading + 2 counts) TIMER Range: 0.0-999.9 secs Resolution: 0.1 sec Accuracy: (0.1% of reading + 0.05 secs) GROUND Current: DC 0.1 A ± 0.01 A, fixed CONTINUITY CHECK Resistance: 0.01 Ω - to 1.50 Ω GROUND GFI Trip Current: 450 µa max (AC or DC) FAULT INTERRUPT HV Shut Down Speed: < 1 ms INSULATION RESISTANCE TEST MODE (Model 3670) VOLTAGE Range: 30-1000 V DC Resolution: 1 V Accuracy: ± (2% of reading + 5 V) RESISTANCE Range: 1-9999 MΩ (4 Digit, Auto Ranging) Resolution: 500 V DC - 100 V DC MΩ MΩ 0.001 1.000-9.999 0.01 10.00-99.99 0.1 100.0-999.9 1 1000-9999 Accuracy: ± (2% of reading + 2 counts) at test voltage 500-1000 V and 1-999.9 MΩ ± (5% of reading + 2 counts) at test voltage 500-1000 V and 1000 Ω - 9999 MΩ ± (8% of reading + 2 counts) at test voltage 30-500 V and 1-1000 MΩ IR VOLTAGE Range: 0-1000 V Resolution: 1 V/step Accuracy: ± (2% of reading + 2 V) MAXIMUM RESISTANCE LIMIT Range: 0,1-9999 MΩ (0 = OFF) MINIMUM RESISTANCE LIMIT Range: 1-9999 MΩ IR DELAY Range: 0, 0.5-999.9 sec (0 = Constant) Resolution: 0.1 sec/step Accuracy: ± (0.1% + 0.05 sec) GROUND GFI Trip Current: 450 µa max FAULT INTERRUPT HV Shut Down Speed: < 1 ms REMOTE CONTROL & SIGNAL PROGRAM MEMORY SECURITY BUZZER LINE CORD TERMINATIONS GENERAL SPECIFICATIONS The following input and output signals are provided through two 9 pin D type connectors: 1. Test, Reset, and Remote Interlock 2. Remote recall of memory program #1, #2 & #3 3. Outputs: Pass, Fail, Test-in-Process, & Reset. 10 Sets 3 steps per set-up with ability to link tests in any order. Lockout capability to avoid unauthorized access to test set-up program. 128 x 64 dot resolution with front panel contrast setting. Alarm with volume control. Detachable 7 ft. (2.13 m) power cable terminated in a three prong grounding plug. Detachable 5ft. (1.52 m) high voltage and return leads (2) with clips and a standard U.S. style (NEMA 5-15) remote receptacle box for testing items terminated with a line cord. International receptacles also available. Front and Rear outputs standard. MECHANICAL Tilt up front feet. 2U 1/2 rack. Dimensions: 8.5 x 3.5 x 14.5 inches (215 x 89 x 370 mm) Weight: approx. 22 lbs. (10 kgs) ENVIRONMENTAL Operating Temperature: 32-104 F (0-40 C) Relative Humidity: 0 to 80% CALIBRATION Traceable to National Institute of Standards and Technology (NIST). Calibration controlled by software. Adjustments are made through front panel keypad in a restricted access calibration mode. Calibration information stored in nonvolatile memory.

HYAMP III SPECIFICATIONS Model 3130 Ground Bond Tester INPUT VOLTAGE GROUND BOND TEST MODE 115/230V selectable, ± 10% variation 50/60 Hz, ± 5% GENERAL SPECIFICATIONS VERIFICATION Built-in software driven verification SYSTEM menu to test fault detection circuits. FUSE 6.3 A fast blow 250 VAC Current: AC 1-30 A, 0.01 A/step Regulation: ± (2% of setting + 0.02 A) Voltage: AC 6 V fixed REMOTE CONTROL & SIGNAL The following input and output signals are provide through two 9 pin D type connectors; 1. Remote control: Test, Reset, Interlock and Withstand Processing FREQUENCY 50/60 Hz selectable PROGRAM MEMORY 2. Outputs: Pass, Fail, Test in Process, Start Out, and Reset Out 10 Memories, 3 Steps per memory. DWELL TIME FAILURE S 0 and 0.5-999.9 secs, 0.1 sec/step 0 for continuous running Accuracy: ± (0.1% of setting + 0.05 secs) Max. limit: 0-120 mω for 1-30 A, 1 mω/step 0-510 mω for 1-10 A, 1 mω/step Accuracy: ± (2% of setting + 2 mω) SECURITY LINE CORD Key Lock capability to avoid unauthorized access to all test parameters. Memory Lock capability to avoid unauthorized access to Memory locations. Detachable 7 ft. (2.13m) power cable terminated in a three prong grounding plug. MILLIOHM OFFSET METERING Min. limit: 0-120 mω for 1-30 A, 1 mω/step 0-510 mω for 1-10 A, 1 mω/step Accuracy: ± (2% of setting + 2 mω) Offset Capability: 0-100 mω, 1 mω/step Accuracy: ± (2% of setting + 2 mω) Ammeter (3 digits) Range: 0-30 A Resolution: 0.01 A/step Accuracy: ± (3% of reading + 0.03 A) Ohmmeter (3 digits) Range: 0-510 mω Resolution: 1 mω/step Accuracy: ± (2% of reading + 2 mω) ALARM VOLUME CALIBRATION MECHANICAL 128 x 64 dot resolution with front panel contrast setting. Front panel adjustable volume setting with 10 set points. Traceable to National Institute of Standards and Technology (NIST). Calibration controlled by software. Adjustments are made through front panel keypad in a restricted access calibration mode. Calibration information stored in nonvolatile memory. Tilt up front feet. 2U 1/2 rack. Dimensions: 8.5 x 3.5 x 14.5 inches (215 x 89 x 370 mm) Timer (4 digits) Range: 0-999.9 secs Resolution: 0.1 secs/step Accuracy: ± (0.1% of reading + 0.05 secs) Weight: 19.65 lbs. (8.9 Kgs) ENVIRONMENTAL Operating Temperature: (0-40 C) Relative Humidity - 0 to 80% Unless otherwise stated, accuracies are relative to a laboratory standard measurement. ACCESSORIES ACCESSORIES: Resistor Kit Precision 1% resistor is ideal as a load to set current trip points. Meets 120 k ohm requirements. 35534 Black Stationary Probe Provides an insulated fixed metallic contact point to a DUT for a return path. 35539 Foot Switch Ideal for applications where an operator needs to start a test hands off the instrument. 35822 Retractable Probe High voltage retractable 5 KV AC probe for safe testing and application of high voltage. 38081 Retractable Return Probe This retractable probe is used on the return side of the Hypot III. 38082 Safe-T-Probe Test gun with trigger that controls retractable probe and activates instruments high voltage circuit. 38083 Adjustable Resistor Bank Provides test loads from 120 K to 2.148 k ohms. 6 terminals with 12 settings. Helps verify regulation. 36956 Interface Kit Includes cables and adapter box so multiple tests can be performed through a single DUT. 260-01

The Industry s Most Complete Line of Instruments for Electrical Safety Compliance Testing NEW! The first fully-automated, multi-functional Electrical Safety Compliance Analyzer with an enhanced graphic LCD that provides complete test setup and results in an easy-to-use interface. Our base model, OMNIA 4 includes AC Hipot, DC Hipot, Ground Bond/Continuity and Insulation Resistance. Also available for OMNIA 4 is an optional built-in scanner. The OMNIA 5 adds Functional Run testing and OMNIA 6 adds the Functional Run test and Line Leakage testing to the base model. State-Of-The-Art Electrical Safety Compliance Testing Instruments Knowledgeable Customer Support And Expert Technical Services At 1-800-858-TEST Software designed to store, analyze and retrieve data on automated Associated Research instruments, while performing Line Leakage, Insulation Resistance, Dielectric Withstand, Ground Bond and Functional Run tests. Autoware also allows for bar coding inputs and provides basic statistical analysis graphs. 4-in-1 Electrical Safety Compliance Analyzers include AC/DC Hipot, Insulation Resistance, Ground Bond tester and optional built-in scanner in a single instrument. Complete with IEEE-488 (GPIB), RS-232 or printer interface. Available in 500 VA output versions. Guaranteed Product Satisfaction And A 5-Year Extended Product Warranty* *With Annual Calibration from Associated Research 24-Hour Turn-Around On All Instrument Calibrations 3-in-1 Dielectric Analyzers with AC, DC or AC/DC Hipot, Insulation Resistance and optional built-in scanner available on some models. All models available with either IEEE-488 (GPIB), RS-232 or printer interface. Available in 500 VA output versions. SWITCHING MATRIX The HS-8A is an 8 port scanner and the HS-16 is a 16 port scanner. Both models are highvoltage and high-current matrix scanners for multi-point or multi-product testing. (For use with QUADCHEK II or HypotULTRA II.) Designed to automate line leakage testing in production line or lab environments. The 510L is a stand-alone system and the 520L can interconnect with other AR safety testers to form a complete automated testing system. The 905D functional run test system measures current, voltage, power factor and watts. It can be interconnected to our safety testers so all tests can be performed through a single DUT connection. Available with standard GPIB or RS-232 interface. Informative Industry Seminars, Professional Training And Educational Programs Local Sales Offices Throughout The World To Serve You More Efficiently The first semi-automated microprocessor controlled Dielectric Withstand testers available in AC or AC/DC versions. All models include enhanced PLC control, remote memory recall, advanced failure detection systems. Available optional 10 V analog signal and real current. Catalog # HYPOT III 1/02 30 Amp Ground Bond tester that works as a stand-alone instrument or can be interconnected to the HypotPLUS II to form a semi-automated test system with a single DUT connection. 13860 West Laurel Dr. Lake Forest, IL 60045-4546 Tel: 847-367-4077 Fax: 847-367-4080 E-mail: info@asresearch.com For more information visit our web site at: www.asresearch.com and ORDER ON-LINE! Or contact us toll-free at: 1-800-858-TEST(8378)