BUFFER TANKS. ASME Commercial Buffer Tanks



Similar documents
G234X-55 Conventional Gas Boiler

FILLING AND PURGING THE SYSTEM

GLOBACON 05 HVAC Systems for Cogen

In-Line Air Separators

Commercial & Industrial Propane Regulators and Meters

Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank

ENERGY RETROFIT PROGRAM

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

HOT WATER SYSTEMS CONTENTS

REGULATING VALVE APPLICATIONS

Commercial Semi-Instantaneous Water Heaters

Commercial Gas Water Heaters

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

ASME Packaged Indirect Fired Water Heater

HEAT INTERFACE UNITS (Modular)

Commercial Boiler Systems and Controls

presents Hydraulic Separation Beyond Primary / Secondary Piping

MUELLER FALLING FILM CHILLERS

Indirect-fired Steam & Boiler Water Heaters

SIOUX HYBRID WATER HEATER

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

HS-901(A) BASIC STEAM HEATING SYSTEMS

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Commercial Storage Tanks

REGULATORS 175/153 Series

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

Hot Water Makers. Efficiency at its Best

University of Maryland College Park District Energy System. IDEA Campus Energy Conference February 9, 2012

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

BULLETIN NO. TEH-908. Bell & Gossett R T. Hydronic System Design with the Bell & Gossett System Syzer / ON GPM FLOW

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

FLASH TANK ECONOMIZER PRODUCT GUIDE

Commercial Gas Water Heaters

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Copyright 2012 Mayekawa Mfg. Co.,Ltd. All Rights Reserved.

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

High Performance Hot Water Systems Denver July 2010

Air Eliminators and Combination Air Eliminators Strainers

How To Clean Up A Reactor Water Cleanup

Condensing Boiler Efficiency

Heating Water by Direct Steam Injection

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Application Engineering

Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Recover Heat from Boiler Blowdown Water

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

steam centre of excellence Steam Boiler System Optimization

POLK STATE COLLEGE CHILLER PLANT EVALUATION WINTER HAVEN, FLORIDA APRIL 2, C arastro & A ssociates, C&A# 5747

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

NAVIEN AMERICA INC FITCH AVENUE

Industrial Steam System Process Control Schemes

Mixing Valves. ARGUS Application Note: Mixing Valves

Technical Data Manual Model Nos. and pricing: see Price List

TES for Medical Center

API Flanged Safety Relief Valves Series 526 CATALOG

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

RECON WATER HEATER INSTALLATION FORM

REGULATORS D& HD Series

DESIGNER S GUIDE EFFICIENCY+ BOILER

Refrigeration Basics 101. By: Eric Nelson

Rule EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS

AABC Specifications for Testing and Balancing HVAC Systems

BLADDER SURGE CONTROL SYSTEM

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

HYDROSTATIC TEST PUMPS

Laundry Hot Water Systems

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

Better Boilers.

Temperature Regulators

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

The Piping System Model a New Life Cycle Document. Elements of the Piping System Model

NEW JERSEY CENTER OF EXCELLENCE

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

HYDRAULIC AND LUBE OIL HEATERS HYDRAULIC AND LUBE OIL HEATERS. HL Series. Warren Electric Corporation

EcoDesign & Labelling Directive (ErP)

THE UNIVERSITY OF TEXAS MEDICAL BRANCH (UTMB) AT GALVESTON

Energy Efficiency in Steam Systems

Fundamentals of Hydronic Design

Domestic Hot Water Systems and Plumbing Products

Texas State University Utility Analysis. Sheri Lara, CEM, CEFP Texas State University Morgan Stinson, PE, LEED AP - EEA Todd Schmitt, PE, LEED AP EEA

Installation & Operation Manual Models: SIT030 - SIT119

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

Sample Exam Questions and Recommended References for ABC s Backflow Prevention Assembly Tester Exam

Steam System Efficiency. Bill Lumsden Leidos Engineering

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

FRL/AirCare Air Controls & Accessories

ENERGY SAVING WORT BOILING SISTEM IN BREWING FACTORY

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Transcription:

BUFFER TNKS SME Commercial Buffer Tanks For Closed Thermal For Closed Water Loop Systems

BUFFER TNKS mtrol SME Buffer Tanks add capacity to non-potable, closed systems to help reduce cycling, improve temperature control and provide more consistent system operation. vailable for chilled water and hot water applications, these Buffer Tanks are all made in the US at our ISO 9001:2008 registered facilities. Chilled Water Buffer Tank CWBT Series Meets all SME Section VIII, Division I standards. vailable up to 1,040 gallons. Connections from 3" to 12". Internal baffle helps properly circulate water. Maximum Working Pressure: 125 or 150 psig. Maximum Operating Temperature: 450 F. How It Works Water enters the buffer tank and is diverted up and over the internal baffle to circulate the water and take full advantage of the tank volume. Typical Installation Internal Baffle BUFFER TNK CHILLER IR HNDLER Inlet Outlet OTHER VLVES ND CCESSORIES REQUIRED FOR INSTLLTION RE NOT SHOWN.

for Chilled and Hot Water Systems Hot Water Buffer Tank HWBT Series Meets all SME Section VIII, Division I standards. vailable in 2 or 4 port options. vailable up to 300 gallons. vailable in 2", 3" & 4" connections. Maximum Working Pressure: 125 or 150 psig. Maximum Operating Temperature: 450 F. How It Works Tank provides added capacity in high efficiency systems that incorporate small, modular, low-mass condensing boilers. 4-port tanks allow for primary / secondary flow through the vessel. This is usually required for systems with multiple small or low volume zones to maximize boiler efficiency and overall system performance. 2-port tanks are typically used in standard applications where all zones are similarly sized. System Flow > Boiler Flow System Flow = Boiler Flow System Flow < Boiler Flow SUPPLY SUPPLY SUPPLY RETURN RETURN RETURN Typical Installations 2 Port Installation 4 Port Installation

Sizing Hot Water Buffer Tanks For dding Capacity to Closed, Non-Potable Hot Water Systems Required Information Boiler Cycle Time (minutes) Minimum Boiler Output (BTU/hr) Minimum System Load (BTU/hr) Temperature Differential ( F) Example: Boiler Cycle Time: 5 minutes Minimum Boiler Output: 200,000 BTU s Minimum System Load: 25,000 BTU s Temperature Differential: 170-180 = 10 F Pipe Size: 2" Relief Valve: 50 PSI 5 (200,000-25,000) = 175 Gallons* 10 x 500 Recommendation: HWBT200-2-125 *Select tank equal to or greater Manufacturer's recommended minimum boiler cycle time* Minutes Minimum Boiler Output ( - ) BTU/hr. BTU/hr. Temperature differential within tank*** F. Minimum System Load** x 500 * Typical 1-10 min. (use 5 if unknown). ** ssume to be 0 if no system load or if rate is unknown. *** Temperature differential can range from 5 to 25 F., 10 F is typical. = Buffer Tank Size Gallons B HWBT Series Specifications G D Model Number Ports Tank (Gallons) Connection Size Dimensions (Inches) B C D E F G H Shipping Weight (lbs.) HWBT120-2 2 120 2 24 33⅛ 55¾ 16 15 45-254 279 HWBT120-3 2 120 3 24 33⅛ 55¾ 16 15 45-268 295 125 PSI 150 PSI F E DRW OR BLOWDOWN HWBT200-2 2 200 2 30 39 62½ 24 21½ 45½ - 475 523 HWBT200-3 2 200 3 30 39⅛ 62½ 24 21½ 45½ - 490 539 HWBT300-2 2 300 2 36 45⅛ 80⅜ 30 32¼ 61¼ - 668 735 C HWBT300-3 2 300 3 36 45⅛ 80⅜ 30 32⅛ 61-683 751 HWBT120-2/2 4 120 2/2 24 33⅛ 55¾ 16 15 45 27 267 294 B HWBT120-2/3 4 120 2/3 24 33⅛ 55¾ 16 15 45 27 282 310 HWBT120-3/3 4 120 3/3 24 33⅛ 55¾ 16 15 45 27 297 327 G D F E C DRW OR BLOWDOWN H HWBT120-4/4 4 120 4/4 24 33⅛ 55¾ 16 15½ 44½ 27½ 338 372 HWBT200-2/2 4 200 2/2 30 39 62½ 24 21½ 45½ 35½ 489 538 HWBT200-2/3 4 200 2/3 30 39 62½ 24 21½ 45½ 35½ 503 553 HWBT200-3/3 4 200 3/3 30 39⅛ 62½ 24 21½ 45½ 35½ 518 570 HWBT200-4/4 4 200 4/4 30 39⅛ 62½ 24 21½ 45½ 35½ 560 617 HWBT300-2/2 4 300 2/2 36 45⅛ 80⅜ 30 32¼ 61¼ 48¼ 682 750 HWBT300-2/3 4 300 2/3 36 45⅛ 80⅜ 30 32⅛ 61 48⅛ 696 766 HWBT300-3/3 4 300 3/3 36 45⅛ 80⅜ 30 32⅛ 61 48⅛ 711 782 HWBT300-4/4 4 300 4/4 36 45⅛ 80⅜ 30 32⅛ 61 48⅛ 753 828

Sizing Chilled Water Buffer Tanks For dding Capacity to Closed, Non-Potable Chilled Water Systems Required Information Total Chilled Capacity in Tons System per Ton* = C = V R ctual System in Gallons = V *Check with Chiller Manufacturer for specific requirements. Typical HVC chiller systems are between 3 and 6 gallons per ton. pplications where temperature accuracy is critical requires 6 to 10 gallons. ( Total Chilled Capacity Tons (C) System Per Ton ) System x - = Gallons/Ton (V R ) Gallons (V ) Buffer Tank Size Gallons Example: Total Chilled Capacity (C): 100 Tons System (V R ): 10 Gallons Per Ton ctual System (V ): 800 Gallons Pipe Size: 4" Relief Valve: 50 PSI (100 x 10) - 800 = 200 Gallons* Recommendation: CWBT200-4-125 *Select tank equal to or greater CWBT Series Specifications F D B E C INTERNL BFFLE DRW OR BLOWDOWN Model Number Tank (Gallons) Connection Size Dimensions (Inches) Shipping Weight (lbs.) B C D E F 125 PSI 150 PSI CWBT120-3 120 3 24 33⅛ 55¾ 16 15 294 323 CWBT120-4 120 4 24 33⅛ 55¾ 16 15½ 315 347 CWBT120-6 120 6 24 33⅛ 55¾ 16 16½ 333 366 CWBT200-3 200 3 30 39⅛ 62⅜ 24 21½ 527 580 CWBT200-4 200 4 30 39⅛ 62⅜ 24 22 547 602 CWBT200-6 200 6 30 39⅛ 62⅜ 24 23 566 623 CWBT300-4 300 4 36 45 80⅜ 30 32⅛ 753 828 CWBT300-6 300 6 36 45 80⅜ 30 33⅛ 772 849 CWBT300-8 300 8 36 45 80⅜ 30 34⅛ 801 881 CWBT500-6 500 6 42 51 99½ 30 36½ 1,366 1,503 CWBT500-8 500 8 42 51 99½ 30 37½ 1,395 1,535 CWBT500-10 500 10 42 51 99½ 30 38½ 1,490 1,639 CWBT850-6 850 6 54 64⅛ 114 7 16 42 39½ 2,707 2,978 CWBT850-8 850 8 54 64⅛ 114 7 16 42 40½ 2,736 3,010 CWBT850-10 850 10 54 64⅛ 114 7 16 42 41½ 2,771 3,048 CWBT1040-8 1040 8 60 70 107⅞ 45 36 3,136 3,450 CWBT1040-10 1040 10 60 70 107⅞ 45 37 3,171 3,488 CWBT1040-12 1040 12 60 70 107⅞ 45 38 3,283 3,611

Made in the US From modest beginnings in founder Chet Kirk s garage to our current, state-of-the-art facilities, mtrol is still proudly manufacturing products in the US. Our talented, dedicated associates are committed to providing you with the highest quality, most reliable and best performing products on the market. ssociates at our West Warwick, Rhode Island manufacturing facility. dditional support materials include: Commercial and Industrial Products Catalog (MC 4401) Data Submittal Sheets (MC 4400) Engineering Handbook (MC 4402P) Product Sizing programs on www.amtrol.com Revit Files (MC 10205) utocd Files (MC 10029) 1400 Division Road, West Warwick, RI 02893 US T: 800.426.8765 F: 800.293.1519 2015 MTROL Inc. www.amtrol.com MC 10263 (01/15)