Automotive CAN gateway module



Similar documents
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Modular I/O System Analog and Digital Interface Modules


with Electronic Assistant

Omega ICD Intelligent Colour Display

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF,

Product Datasheet P MHz RF Powerharvester Receiver

MultiViu Flex 7 Data Sheet

Installation manual. Generator Paralleling Controller GPC multi-line C

Technical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB,

HF series Hall effect joysticks

Kvaser Mini PCI Express User s Guide

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

Data Sheet. Adaptive Design ltd. Arduino Dual L6470 Stepper Motor Shield V th November L6470 Stepper Motor Shield

CAN-Bus Troubleshooting Guide

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

ABB Drives. User s Manual HTL Encoder Interface FEN-31

PLUTO Safety-PLC. Manual Absolute Encoders

HP4000EX Hardware Manual

Product Information Fire alarm panel 8000 C

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

NC-12 Modbus Application

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

PCS0100en Persy Control Services B.V. Netherlands

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Permissible ambient temperature Operation Storage, transport

Technical Data Sheet OPUS A8 ECO Full

CANTEC-2XL. Description

Fieldbus slave modules with I/Os, DIO

Positioning Controller

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

CAN BUS UTILITY VW ACTIVE MSY

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

IMR 6000/10../20../30

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

Digital display DA 48

«Filter-MB» Technical Manual

TEA1024/ TEA1124. Zero Voltage Switch with Fixed Ramp. Description. Features. Block Diagram

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Number 1 in efficiency

Install the DeviceNet Module using the following procedure:

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

psens Pressure Measurement

is then retained absolutely without interruption.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

USB-to-CAN V2 compact

MCB-02 module installation

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

SmartWire Panel Wiring Solutions the easy way to connect

Digital input modules

User Manual for CH-PFC76810

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Multifunction devices

ELECTRONIC CONTROL UNITS. Machine Management Systems. Description. EC-MMS-1012-H 10 inputs, 12 outputs meter-in systems controller 20

INDUSTRIAL VOLTAGE AMPLIFIER IC AM401 PRINCIPLE FUNCTION

DMX2PWM 9 Channel Dimmer Setup Manual

FM4100 USER MANUAL V1.4

MINI MCR-SL-R-UI(-SP)

Analog Servo Drive 25A8

Liquid Level Limit Switch liquiphant T FTL 20

UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Combi B Alarm box. Mounting instructions

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

MILE Encoder for EC 90 flat

Road Vehicles - Diagnostic Systems

Fleet Management - Smart, Secure and Easy

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

INSTALLATION MANUAL TRAILER LIGHTS CONTROLLER MODULE TYPE MP2-D1 / MP2-D2

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

THE INPUT/OUTPUT SYSTEM. Key Points

LMU Hardware and Installation Guide

TX OPEN RS232/485 module

USBSPYDER08 Discovery Kit for Freescale MC9RS08KA, MC9S08QD and MC9S08QG Microcontrollers User s Manual

Input module, input/output module

sontheim Wir leben Elektronik! We live electronics! Industrie Elektronik GmbH Computer-on-Modules Overview of our Computer-on-Modules

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

CAN bus ESD protection diode

Kit 27. 1W TDA7052 POWER AMPLIFIER

GT Sensors Precision Gear Tooth and Encoder Sensors

WIND Power Technology: IMD Integrated Motor Drive

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

CAN AND NETWORK COMMUNICATIONS

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Transcription:

Function The compact vehicle suitable CAN gateway module with PLC and soundfunction is to easily extend existing vehicle functions with low wiring costs. It is freely programmable and equipped with three CAN interfaces. Thus it is possible to activate functions in the vehicle directly via CAN. Through the OBD connection and free programming other functions are programmable. Several vehicle CAN protocols are available on request. Application Examples: Transfer of vehicle secondary functions (e.g. wheelchairs) Vehicle customizings, which data from the CAN-bus receive or activate functions via CAN Additional control points in vehicles (e.g. driving Schools) Vehicle customizings for construction equipment Housing and connector dimension: 89 x 95 x 35 mm connector: 3 x 18-pin Molex Mini Fit Junior 3D view 1

Data exchange: Bus system For the data exchange are the following bus systems available: 3 x CAN high speed according to ISO 11898-2 or optional with 1 x CAN high speed and 2x CAN low speed Technical Data: operating temperature: -40 C up to 85 C voltage range: 9-18 V protection class: IP53 EMC: 2009/19/EG e1 approval number: 03 588 20 analog input (digital usable) 4 digital HSD outputs potential free relais soundmodule (bleeperfunction) each HSD output max. 2,5A at t amb <80 C each relais output 3A Freescale HCS12XEQ processor with flash-technology (optionally multiprogramming) 3 x CAN high speed or optional with 1 CAN high speed and 2 CAN low speed o 1.042.100.00: CAN0: CAN-HS with 120Ω load resistor CAN1: CAN-HS without load resistor, e.g. connection with existing CAN-bus CAN2: CAN-HS with 120Ω load resistor o 1.042.110.00: CAN0: CAN-HS with 120Ω load resistor CAN1: CAN-LS CAN2: CAN-LS compact housing (85 x 95 x 35 mm), connector 3 x 18-pin Molex Mini Fit Junior. thanks to its powerful processor, the module is CANopen- und SAE J1939- able 2

Programming A Freescale HCS12 processor with flash-technology is used, which can be programmed a number of times. Two methods of functional programming: 1. Graphical programming with MRS Developers Studio, the integrated softwaretool CANgraph and suitable flash-programming-tool. 2. Programming with a C-development system e.g. Codewarrior. Advantages of graphical programming with MRS Developers Studio There is no need for detailed knowledge of the microcontroller and a programming language. This system provides pure graphical programming of the controller. The acquisition and training costs are very small. Preference: With graphical programming the possibilities of bus communication are limited. Advantages of programming with a C-development system Very complex as well as user specific functions can be realized. Preference: An extensive knowledge of C-programming, the HCS12 microprocessor and the circuit is absolutely necessary. Options communication slot-expansion with radio module e.g. bluetooth to SCI to operate functions wireless 3

Hardware Connector: 3 x 18-pin Molex Mini Fit Junior Supply: Controller supply: 9 18 V The module is protected against reverse polarity and electrical transients. The module has a Quad-Highside-Driver and potential free relay outputs. The quiescent current is less than 1mA (Stand by). The power consumption without load at the outputs approx 40mA. Power-on: The module can switched on with the ignition signal at KL15 or CAN-bus, then it keeps itself through the MC/Power Signal. Inputs: The module has 20 analog inputs. These are 0 30 V inputs ans can be used digitally to 30 V. Outputs: Quad Power-Highside-Driver (Type VNQ5050AK oder VNQ5050), overload and short-circuit protected with a digital status load. The status can be used to detect an open load or overload condition. At 80 C environment temperature each channel can supply up to 2,5A. 4

Connector assignment Connector Pin Pin Function on the board X101.01 GND ground X101.02 KL 15 ignition (KL15) X101.03 AI 19 analog input 0-12V X101.04 AI 20 analog input 0-12V X101.05 nc Not connected X101.0 nc Not connected X101.07 CAN2-H CAN high from CAN-bus 2 X101.08 CAN1-H CAN high from CAN-bus 1 X101.09 CAN0-L CAN low from CAN-bus 0 X101.10 KL 30 Vcc 12V X101.11 BL Bootloader X101.12 HSD1 HSD-Out 1 X101.13 HSD2 HSD-Out 2 X101.14 HSD3 HSD-Out 3 X101.15 HSD4 HSD-Out 4 X101.1 CAN2-L CAN low from CAN-bus 2 X101.17 CAN1-L CAN low from CAN-bus 1 X101.18 CAN0-H CAN high from CAN-bus 0 X102.1 K-NC normally closed of relay X102.2 K5-NC normally closed of relay 5 X102.3 K5-NO normally open of relay 5 X102.4 K4-NO normally open of relay 4 X102.5 K3-COM common of relay 3 X102. K3-NO normally open of relay 3 X102.7 K2-NO normally open of relay 2 X102.8 K1-NO normally open of relay 1 X102.9 K1-NC normally closed of relay 1 X102.10 K-COM common of relay X102.11 K-NO normally open of relay X102.12 K5-COM common of relay 5 X102.13 K4-COM common of relay 4 X102.14 K4-NC normally closed of relay 4 X102.15 K3-NC normally closed of relay 3 X102.1 K2-COM common of relay 2 X102.17 K2-NC normally closed of relay 2 X102.18 K1-COM common of relay 1 X103.1 ANA1 analog input 0-12V X103.2 ANA2 analog input 0-12V X103.3 ANA3 analog input 0-12V 5 X103.4 ANA4 analog input 0-12V

X103.5 ANA5 analog input 0-12V X103. ANA analog input 0-12V X103.7 ANA7 analog input 0-12V X103.8 ANA8 analog input 0-12V X103.9 ANA9 analog input 0-12V X103.10 ANA10 analog input 0-12V X103.11 ANA11 analog input 0-12V X103.12 ANA12 analog input 0-12V X103.13 ANA13 analog input 0-12V X103.14 ANA14 analog input 0-12V X103.15 ANA15 analog input 0-12V X103.1 ANA1 analog input 0-12V X103.17 ANA17 analog input 0-12V X103.18 ANA18 analog input 0-12V BL* = boot loader input, if high the boot loader is active. Available vehicle protocols Following vehicle protocols are currently available: Mercedes C+E Class Mercedes Sprinter Chrysler Voyager KIA Carnival VW Caddy Skoda Yeti Skoda Octavia Skoda Superb Mini Cooper Citroen DS4 Peugeot 100 Other vehicle types can be analyzed and are also available upon request. Further informations: MRS Electronic GmbH www.kfz-relais.com Klaus-Gutsch-Str. 7 www.mrs-electronic.com D - 7828 Rottweil +49 741 28 07-12 sales@kfz-relais.com