LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels



Similar documents
Phase-Adaptive Power Module

GRX-PWM Pulse Width Modulation Interface

Switching Power Module

Control Interfaces. GRAFIKR Systems a LUT-DMX

Remote Power Panels with Breakers

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

QSE-CI-DMX Control Interface

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

How To Use A Lutron Power Supply

OMX-RS232 Control Interface

QSE-CI-NWK-E Control Interface

LIEBERT VNSA Installation Sheet

HomeWorks QS Processor

Lighting Control Systems

INSTALLATION INSTRUCTIONS

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Operation and Installation Manual

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

Electronic Control Devices The European Product Catalogue 2007

RF Maestro Local Controls

TX OPEN RS232/485 module

HMI display Installation Guide

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Lightning Arresters P KVA P KVA. Description & Installation

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

How To Test A Power Distribution Unit

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

Circuit Breakers. Next Generation of Protection Capabilities

I NTERFACE CABLE ADAPTER MODULE

Secondary Unit Substations

LED DIMMING A HELPFUL GUIDE...

Distribution Dry Type Transformers

Dual Technology Ceiling Mount Sensor

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

D4 HP Dimmer User s Manual Rev City Theatrical, Inc.

Electronic Control Devices The European Product Catalogue 2007

Operation Manual. Trans-Flo

LOXONE 12 Channel Amplifier

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

HomeWorks QS Wired Signature SeriesTM Keypads

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

MechoNet TM Network Interface (MNI) Specification Submittal

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Canopy Surge. User Manual

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Emergency lighting units EM powerled

Product and functional description

8146/5 Series Breaker Panelboards

Parallel Redundant Uninterruptible Power Supply

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

AMPSEAL* Automotive Plug Connector and Header Assembly

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

How To Use A Ds340 (Dsp)

TSn SERIES Surge Protective Device

About the BitStorm 6051 POTS Splitter

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

STRATO LED Drivers 70W, Single output

Power Supplies 3. SDN-P DIN Rail Series

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

vacon 100 vacon 100 flow vacon 100 hvac ac drives installation manual wall-mounted drives

HomeWorks QS Wired seetouch Designer Keypads

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

BETA Protecting SITOR Semiconductor Fuses

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Technicaldata General

THERMAL MANAGEMENT SOLUTIONS

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Radiant Temperature Sensor TY7321

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS SpaceBuild Specification Worksheet. Touch Screens

GRAFIK 5000TM/6000 /7000TM System Onsite Startup

CompactLogix Power Supplies Specifications

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

MCR1900 Media Converter 19-Slot Chassis

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

EMBEDDED ACCESS CONTROL Hardware Installation Guide

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Transcription:

369344c 04.28.204 LP dimming panels are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Works directly with incandescent, magnetic low voltage, and neon/cold cathode lighting, as well as Lutron TuWire fluorescent dimming ballasts. Works with electronic low-voltage lighting via power interfaces. Works with 3-wire AC motors through motor modules. Panels are prewired just bring in feed and load wiring. Surface or recess mount between 6 in (40 cm) center-to-center studs. Models available with: 20 V~, 220 240 V~ (non CE), or 230 V~ (CE) input power. 8 dimming modules for 4 32 dimming legs. Different feed types and breakers. work with: GRX-4000 control units. GRAFIK 5000TM, GRAFIK 6000, and GRAFIK 7000TM systems. GP dimming panels and XP switching panels. DMX52 dimming systems via the 2LinkTM option. Quantum systems. Mini LP Dimming Panel LP/4 LP3/2 Standard-Size LP Dimming Panel LP4/28 LP8/32 Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Specifications 369344c 2 04.28.204 Standards (20 V~ panels only) UL Listed (Reference: UL File 4207). Complies with CSA, OM, or CE (where appropriate. Contact Lutron for listing details on custom panels). Seismic certified panels can be provided upon request. Contact Lutron for details. Power Input power: 20 V~, 220 240 V~ (non CE), and 230 V~ (CE). All voltages 50/60 z, phase-to-neutral. Branch circuit breakers (AIC ratings): 20 V~ 0,000 A 220 240 V~ 6000 A 230 V~ (CE) 6000 A Lighting strike protection: Meets ASI/IEEE standard 62.4-980. Can withstand voltage surges of up to 6000 V~ and current surges of up to 3000 A. 0-year power failure memory: Automatically restores lighting to scene selected prior to power interruption. Short-Circuit Current Ratings (other ratings available) Panel Type Voltage Standard SCCR Rating LP Main Lug Panels 20 V~ 25,000 A (all sizes) Sources/ Types Operates these sources with a smooth, continuous Square Law dimming curve or in a full conduction, non dim state: Incandescent (Tungsten)/alogen. Magnetic Low-Voltage transformer. Lutron Tu-Wire electronic fluorescent dimming ballasts. eon/cold Cathode. Operates these sources via power interfaces: Electronic Low-Voltage transformer via dedicated internal dimming modules or external power interfaces. Lutron electronic fluorescent dimming ballasts via external power interfaces. Operates ID sources in a full conduction, non-dim state. Dimming Modules* Each dimming module can handle a fully loaded electrical circuit, up to four dimming legs per module. Maximum Ratings Voltage Capacity per Dimming Module 20 V~ 6 A 6 A 220 240 V~ (non-ce) 6 A 6 A 230 V~ (CE) 3 A 0 A Capacity per Dimming Leg RTISSTM filter circuit technology compensates for incoming line voltage variations: o visible flicker with +/ 2% change in RMS voltage/cycle and + 2% z change in frequency/second. Wiring Internal: Prewired by Lutron. System communications: Low-Voltage IEC PELV/ EC Class 2 wiring connects dimming panels to other components. Line (mains) voltage: and load wiring only. o other wiring or assembly required. Setup Circuit selector electronically assigns dimming legs to zones and sources; permits reassignment of zones and sources without rewiring. Physical Design Enclosure: EMA-Type, IP-20 protection; 6 U.S. gauge steel. Indoor use only. Weight: 27 lb (3 kg) for Mini LP, 63 lb (29 kg) for Standard-Size LP. Seismic Certification Limits: SDS = 2.5 g, z/h =.0, IP =.5. Contact Lutron for details. Mounting Surface mount or recess mount between 6 in (40 cm) studs. Allow space for ventilating. Environment 32 04 F (0 40 C). Relative humidity less than 90%, non-condensing. * For more information on load ratings, please refer to Application ote #20 at www.lutron.com/technicaldocumentlibrary/048-20.pdf SPECIFICATIO SUBMITTAL Page Job ame: Model umbers: Job umber:

ow to Build an LP Dimming Panel Model umber 369344c 3 04.28.204 L P 7 / 2 8 2 0 4 M L 2 0 C G P _ Prefix umber of Dimming Modules umber of Dimming Legs Voltage Type Panel Branch Circuit Breaker Rating Custom Panel Suffix Prefix LP: Dimming Panel umber of Dimming Modules Indicates number of dimming modules in the panel. Also indicates number of full load circuits. umber of Dimming Legs Indicates number of dimming legs in the panel. Each module has four dimming legs. Voltage 20: 20 V~ 230: 230 V~ (CE) 240: 220 240 V~ (non-ce) Type 2: -phase 2-wire 3: -phase 3-wire (split-phase) 4: 3-phase 4-wire Panel ML: Main Lugs only Mxx: Main Breaker with xx = breaker size in Amps (custom panel option) IS: Isolation Switch (CE/non-CE only) Branch Circuit Breaker Rating 20: 20 A branch circuit breakers (20 V~ only) 5: 5 A branch circuit breakers (20 V~ only) 3: 3 A branch circuit breakers (230 V~ CE only) 6: 6 A branch circuit breakers (240 V~ non-ce only) Custom Panel Suffix CGP number indicates specific characteristics of a customized panel. Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Models 369344c 4 04.28.204 Only standard panels listed. Consult Lutron for further options. Mini 20 V~ Power umber Of Dimming Modules umber Of Dimming Legs Type LP 4 Ø 2W 20 A LP2 8 Ø 2W 40 A Ø 3W 20 A Ø 2W 40 A LP3 2 Ø 3W 40 A 3Ø 4W 20 A Maximum Panel 5 A or 20 A branch circuit breakers 20/6A, 5/2A continuous load rating. 220 240 V~ (non-ce) Power umber Of Dimming Modules umber Of Dimming Legs Type LP 4 Ø 2W 6 A LP2 8 Ø 2W 32 A LP3 2 Ø 2W 48 A 3Ø 4W 6 A Maximum Panel 6 A branch circuit breakers 230 V~ (CE) Power umber Of Dimming Modules umber Of Dimming Legs Type LP 4 Ø 2W 3 A LP2 8 Ø 2W 26 A LP3 2 Ø 2W 39 A 3Ø 4W 3 A Maximum Panel 3 A branch circuit breakers Wire Sizes Wiring Power (ot/live) connects directly to branch circuit breakers: 20 V~: 4 AWG to 0 AWG (2.0 mm 2 to 4.0 mm 2 ) 220 240 V~ (non-ce): 8 AWG to 4 AWG (.0 mm 2 to 25 mm 2 ) 230 V~ (CE): 8 AWG to 4 AWG (.0 mm 2 to 25 mm 2 ) eutral connects to neutral lug: 20 V~: 4 AWG to 2/0 AWG (2.0 mm 2 to 70 mm 2 ) 220 240 V~: 4 AWG to 8 AWG (2.0 mm 2 to 6.0 mm 2 ) 230 V~ (CE): 4 AWG to 8 AWG (2.0 mm 2 to 6.0 mm 2 ) Wiring All Models: 4 AWG to 0 AWG (2.0 mm 2 to 4.0 mm 2 ) SPECIFICATIO SUBMITTAL Page Job ame: Model umbers: Job umber:

Models (continued) 369344c 5 04.28.204 Only standard panels listed. Consult Lutron for further options. Standard-size 20 V~ Power umber Of Dimming Modules umber Of Dimming Legs Type Maximum LP4 6 3Ø 4W 75 A LP5 20 3Ø 4W 75 A LP6 24 3Ø 4W 75 A LP7 28 3Ø 4W 75 A LP8 32 3Ø 4W 75 A Panel Main lugs only Branch Circuit Breakers 5 A or 20 A 20/6A, 5/2A continuous load rating. 220 240 V~ (non-ce) Power umber Of Dimming Modules umber Of Dimming Legs Type Maximum LP4 6 3Ø 4W 25 A LP5 20 3Ø 4W 25 A LP6 24 3Ø 4W 25 A LP7 28 3Ø 4W 25 A LP8 32 3Ø 4W 25 A 230 V~ (CE) Power umber Of Dimming Modules umber Of Dimming Legs Type Maximum LP4 6 3Ø 4W 25 A LP5 20 3Ø 4W 25 A LP6 24 3Ø 4W 25 A LP7 28 3Ø 4W 25 A LP8 32 3Ø 4W 25 A Panel Isolation switch only Panel Isolation switch only Branch Circuit Breakers 6 A Branch Circuit Breakers 3 A Wire Sizes Wiring to Main Lugs (20 V~ Only): Power (ot/live): (3) 4 AWG to 2/0 AWG (2.0 mm 2 to 70 mm 2 ) eutral: () 4 AWG to 2/0 AWG (2.0 mm 2 to 70 mm 2 ) Wiring to Isolation Switch (CE/non-CE only): Power (ot/live): (3) 2.5 mm 2 to 35 mm 2 eutral: () 2.5 mm 2 to 35 mm 2 Wiring All Models: 4 AWG to 0 AWG (2.0 mm 2 to 4.0 mm 2 ) SPECIFICATIO SUBMITTAL Page Job ame: Model umbers: Job umber:

Dimensions 369344c 6 04.28.204 All dimensions shown as: in (mm) Mini Top View 4.38 (365.25) Front View 5.875 (403.23) Right Side View 4.4 (05.36) Left Side View 2.2 (56.05).34 (33.94) 8.00 (203.20) 0.5 (3.8) 24.00 (609.6) 24.50 (622.3) 2.50 (546.) Cover 2.2 (56.05) 0.75 (273.05) 5.3 (384.3) Bottom View 4.09 (03.84) Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Dimensions (continued) All dimensions shown as: in (mm) Standard-size Top View 4.375 (365.3) 369344c 7 04.28.204 Front View 5.875 (403.23) Right Side View 4.2 (06.93) Left Side View 2.43 (6.85) 2.69 (68.25) 8.00 (203.20) 0.5 (3.8) 4.75 (060.45) Cover 59.50 (5.30) 59.50 (5.30) 2.43 (6.85).00 (279.4) 5.25 (394.8) Bottom View 2.69 (68.25) Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Mounting 369344c 8 04.28.204 Mini Surface- or recess-mount indoors. Consult Dimensions page for dimensions and conduit knockout locations. Panel generates heat. Mount only where ambient temperature is 32 04 F (0 40 C). This equipment is air-cooled. Do not block vents or warranty will be void. Mount Panels where audible noise is acceptable. (Panels hum slightly and internal relays click.) Mount Panels so line (mains) voltage wiring is at least 6 ft (.8 m) from sound or electronic equipment and wiring. Mount Panel within 7 of true vertical. Surface Mounting Surface mounting keyholes accept /4 in (6 mm) mounting bolts. This size is recommended. Panel Maximum BTUs/hour Weight Without Packaging LP 90 33 lb (5kg) LP2 70 35 lb (6kg) LP3 250 37 lb (7kg) Maximum and Wire Sizes Consult Wiring page. Recess Mounting Mount to wall stud by screwing through slots in corners of panel. Mount panel between flush and /8 in (3 mm) below finished wall surface. Front View Side View Front View Side View Terminal blocks for dimming wiring and dimming Terminal blocks for dimming wiring and dimming Do not block vents Do not block vents 2 in (3 cm) minimum clearance 2 in (3 cm) minimum clearance wiring and dimming Branch circuit breakers IEC PELV/EC Class 2 wiring wiring and dimming Branch circuit breakers IEC PELV/EC Class 2 wiring Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Mounting (continued) 369344c 9 04.28.204 Standard-size Surface- or recess-mount indoors. Consult Dimensions page for dimensions and conduit knockout locations. Panel generates heat. Mount only where ambient temperature is 32 04 F (0 40 C). This equipment is air-cooled. Do not block vents or warranty will be void. Reinforce wall structure for weight and local codes. Mount Panels where audible noise is acceptable. (Panels hum slightly and internal relays click.) Mount Panels so line (mains) voltage wiring is at least 6 ft (.8 m) from sound or electronic equipment and wiring. Mount Panel within 7 of true vertical. Surface Mounting Surface mounting keyholes accept /4 in (6 mm) mounting bolts. This size is recommended. Panel Maximum BTUs/hour Weight Without Packaging LP4 330 55 lb (25kg) LP5 40 57 lb (26kg) LP6 490 59 lb (27kg) LP7 570 6 lb (28kg) LP8 650 63 lb (29kg) Maximum and Wire Sizes Consult Wiring page. Recess Mounting Mount to wall stud by screwing through slots in corners of panel. Mount panel between flush and /8 in (3 mm) below finished wall surface. Front View Side View Front View Side View Terminal blocks for dimming wiring and dimming Terminal blocks for dimming wiring and dimming Do not block vents Do not block vents 2 2 4 6 3 5 2 in (3 cm) minimum clearance 4 6 3 5 2 in (3 cm) minimum clearance wiring and dimming 8 7 8 7 Main lugs A Main lugs A Preferred feed wiring B C IEC PELV/EC Class 2 wiring Preferred feed wiring B C IEC PELV/EC Class 2 wiring SPECIFICATIO SUBMITTAL Page Job ame: Model umbers: Job umber:

GRAFIK Systems Wiring 369344c 0 04.28.204 Mini Wire the Mini LP panel similarly to a lighting distribution panel: Run feed and load wiring; no other wiring or assembly is required. Run separate neutrals for each module (no common neutrals across phases). The Mini LP panel can provide temporary lighting: Wire all loads. Do not remove the bypass jumpers that protect the dimming modules. Use branch circuit breakers to switch lights on and off. Mini LP (cover off) (Do not remove until load wiring is verified) Terminal blocks Branch circuit breakers eutral lug Power (ot/live) Wiring 20 V~ 4 0 AWG 220 240 V~ 8 4 AWG (.0 25 mm 2 ) 230 V~ (CE) eutral Wiring 20 V~ 4 2/0 AWG (2.0 70 mm 2 ) 220 240 V~ 4 8 AWG (2.0 6.0 mm 2 ) 230 V~ (CE) SPECIFICATIO SUBMITTAL Page Job ame: Model umbers: Job umber:

GRAFIK Systems Wiring (continued) 369344c 04.28.204 Standard-size Wire the LP panel similarly to a lighting distribution panel: Run feed and load wiring; no other wiring or assembly is required. Run separate neutrals for each module (no common neutrals across phases). The LP panel can provide temporary lighting: Wire all loads. Do not remove the bypass jumpers that protect the dimming modules. Use branch circuit breakers to switch lights on and off. Standard LP (cover off) (Do not remove until load wiring is verified) Terminal blocks Branch circuit breakers eutral lug Power (ot/live) Wiring (3) 4 2/0 AWG (2.0 70 mm 2 ) eutral Wiring () 4 2/0 AWG (2.0 70 mm 2 ) SPECIFICATIO SUBMITTAL Page Job ame: Model umbers: Job umber:

Typical Dimming Legs for 20 V~ 369344c 2 04.28.204 All Types except: Lutron i-lume or Eco-0 (ECO Series) Fluorescent Dimming Ballasts Electronic Low-Voltage Dimmed ot (do not remove) eutral Lutron i-lume or Eco-0 (ECO-Series) Fluorescent Dimming Ballasts Use Lutron FDBI Fluorescent Dimming Ballast Interface. Eco-0 or i Lume FDBI Dimmed ot eutral (do not remove) Electronic Low-Voltage Use Lutron ELVI Electronic Low Voltage Interface. Consult ELVI Specification Submittal for more details. Dimmed ot (do not remove) Transformer ELVI eutral Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Typical Dimming Legs for 220 to 240 V~ (non CE) 369344c 3 04.28.204 All Types except: Lutron i-lume or Eco-0 (ECO Series) Fluorescent Dimming Ballasts Electronic Low-Voltage Dimmed Live (do not remove) L eutral Lutron i-lume or Eco-0 (ECO-Series) Fluorescent Dimming Ballasts Use Lutron FDBI Fluorescent Dimming Ballast Interface. Eco-0 or i Lume FDBI Dimmed Live eutral (do not remove) L Electronic Low-Voltage Use Lutron ELVI Electronic Low Voltage Interface. Consult ELVI Specification Submittal for more details. Dimmed Live (do not remove) Transformer ELVI eutral L Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Typical Dimming Legs for 230 V~ (CE) 369344c 4 04.28.204 All Types except: Lutron i-lume or Eco-0 (ECO Series) Fluorescent Dimming Ballasts Electronic Low-Voltage Dimmed Live (do not remove) L eutral Electronic Low-Voltage Use Lutron ELVI Electronic Low Voltage Interface. Dimmed Live (do not remove) Transformer ELVI eutral L Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Low-Voltage IEC PELV / EC Class 2 Wiring (All Models) 369344c 369-344A-5 5.03.0 04.28.204 System communications uses low-voltage IEC PELV / EC Class 2 wiring. Wiring must be daisy-chained. Wiring must run separately from line (mains) voltage. GRAFIK Eye 4000 System IEC PELV / EC Class 2 wiring link requires: Two 2 AWG (2.5 mm 2 ) conductors for control power. One twisted, shielded pair of 8 AWG (.0 mm 2 ) for data link. One 8 AWG (.0 mm 2 ) conductor for emergency (essential) sense line, from panel to panel. Total length of control link may be no more than 2000 ft (60 m). Approved low-voltage cable is available from Lutron, Belden, and Liberty. These are approved with 22 AWG (0.625 mm 2 ) data link wires. LP Panel Control Unit Control Interface Wallstations GRAFIK 5000TM/6000 /7000TM System IEC PELV / EC Class 2 wiring link requires: Two 2 AWG (2.5 mm 2 ) conductors for control power. One twisted, shielded pair of 8 AWG (.0 mm 2 ) for data link. One 8 AWG (.0 mm 2 ) conductor for emergency (essential) sense line, from panel to panel. Total length of control link may be no more than 2000 ft (600 m). If -RPTR interface and GRX-CBL-46L cable is used, length may be up to 4000 ft (200 m). LP Panel 5000/ 6000/ 7000 Processor Control Unit Control Interface Wallstations Refer to GRAFIK 5000TM/6000 /7000TM Specification GRX-CBL-46L IEC PELV / EC Class 2 wiring cable is available from Lutron and contains: Two 2 AWG (2.5 mm 2 ) conductors for control power. One twisted, shielded pair of 22 AWG (0.625 mm 2 ) for data link. One 8 AWG (.0 mm 2 ) conductor for emergency (essential) sense line. Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

IEC PELV / EC Class 2 Panel-to-Panel Wiring (All Models) To additional Power Panels Control Wiring (2) 2 AWG (2.5 mm 2 ) : Common 2: 24 VFW Data Link () shielded, twisted pair 8 AWG (.0 mm 2 ) 3: 4: () 8 AWG (.0 mm 2 ) 5: Sense Line 369344c 6 04.28.204 2 2 3, 4 3, 4 5 Shield/Drain Shield/Drain LP Panel LP Panel 2 To Lighting Controls or Processors 2 3 4 D 5 2 3 4 D 5 Common +24VFW Drain Sense Data A OK Power Data B OK Link A B Link 2 3 4 D 5 C D SELECT CIRCUIT Common Drain Common +24VFW Drain Sense Data A OK Power Data B OK Link A B Link 2 3 4 D 5 C D SELECT CIRCUIT Common Drain Circuit 2 Circuit 2 otes * Emergency power: The additional 8 AWG (.0 mm 2 ) wire is a sense line from terminal 5 of another panel. This sense line allows an emergency (essential) lighting panel to sense when normal (non essential) power is lost. If more than one emergency lighting panel needs to sense from a specific normal panel, a dedicated wire between each pair of normal (non-essential) and emergency (essential) panels may be required. Shield/Drain: Connect shielding as shown. Do not connect to ground (earth) or circuit board of circuit selector. Connect the bare drain wires and cut off the outside shield. IEC PELV / EC Class 2 Terminal Connections Each Low-Voltage IEC PELV / EC Class 2 terminal can accept only two 8 AWG (.0 mm 2 ) wires. Two 2 AWG (2.5 mm 2 ) conductors won t fit. Connect as shown, using appropriate wire connectors. (4) 2 AWG (2.5 mm 2 ) 2 3 4 D 5 Job ame: Data A OK Link SPECIFICATIO SUBMITTAL Page Model umbers: 2 3 4 D 5 A Link C D Common 24VFW Drain Sense SELECT CIRCUIT Power B Comm Data B OK Drain Job umber: Circuit 2

Options 369344c 7 04.28.204 Consult Lutron for ordering information and model numbers. Dimensions and wiring may change based on options chosen. Option Description Application Double Lug Sets Branch Circuit Protection Lutron Ten-Volt Module (TVM) 2LinkTM Allows multiple Panels to be fed from the same feed. Branch Circuit Breakers with higher AIC ratings than those on standard Panels. Panels can also have Branch Circuit Breakers with special ratings such as: GFI (Ground Fault Interrupt) ELB (Earth Leakage Breaker) RCD (Residual Circuit Device). Allows Panels to operate fluorescent ballasts that meet IEC 929 standards for 0 0 V control including: Lutron TVE ballasts 0 0 V neon PWM fluorescent Tridonic DSI (Digital Serial Interface). The TVM can sink or source 50 ma (typically 25 50 ballasts) on each circuit. Allows a DMX52 theatrical console to operate Dimming Panels load circuits. Allows a GRAFIK Eye 4000 Series to handle 28 zones (2 links of 64 zones). The 2 links are independent and do not communicate. Contact Lutron for further details. A single feed and multiple LP Dimming Panels are required. Jobs with fluorescent ballasts that require 0 0 V, PWM, or DSI control. Control of architectural lighting from a DMX52 theatrical console is required. A mix of architectural and theatrical lighting exists on the job. SPECIFICATIO SUBMITTAL Page Job ame: Model umbers: Job umber: