About Coffee and Refractometers 2008-2010 Voice Systems Technology, Inc. (VST)



Similar documents
Density and Refractometry

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Instruction Manual HI Refractometer for Sucrose Measurements

Refractive Index Measurement Principle

Experiment #2: Determining Sugar Content of a Drink. Objective. Introduction

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

CPI Links Content Guide & Five Items Resource

Using the Spectrophotometer

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Physical Properties of a Pure Substance, Water

Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

R013 Determination of dissolved solids (Brix) - A comparison of methods based on refractometers and density meters

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect

GRID AND PRISM SPECTROMETERS

What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)

2C: One in a Million. Part 1: Making solutions. Name: Section: Date: Materials

Mixing Warm and Cold Water

Melting Point, Boiling Point, and Index of Refraction

After a wave passes through a medium, how does the position of that medium compare to its original position?

12.1 What is Refraction pg Light travels in straight lines through air. What happens to light when it travels from one material into another?

A Beer s Law Experiment

Theremino System Theremino Spectrometer Technology

PHYSICAL PROPERTIES: GLASS. Forensic Science CC Spring 2007 Prof. Nehru

The photoionization detector (PID) utilizes ultraviolet

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Sugar Inversion and Brix in Soft Drinks: Cobrix3 multibev Measures Both!

Waves Sound and Light

Correlations Between Citrus Fruit Properties and Ascorbic Acid Content

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

SOLUBILITY OF A SALT IN WATER AT VARIOUS TEMPERATURES LAB

10-ml Graduated cylinder 40 ml 3% Hydrogen peroxide solution (found in stores) Straight-edged razor blade Scissors and Forceps (tweezers)

Thermistor Basics. Application Note AN-TC11 Rev. A. May, 2013 Page 1 WHAT IS A THERMISTOR?

Concentrations and Dilutions of Food Dyes

Acids & Bases Around the House Use a ph indicator to find acids and bases

Light and its effects

THE HUMIDITY/MOISTURE HANDBOOK

Energy - Heat, Light, and Sound

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Experiment 1: Colligative Properties

The Determination of an Equilibrium Constant

Chapter 5 Student Reading

Year 10 Investigation. What Makes Ice Melt Fastest? By Rebecca Hogan

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.

Chapter 17: Light and Image Formation

Acid Base Titrations

Measuring Manganese Concentration Using Spectrophotometry

sugar sugar products for your sweet success

Experiment #5: Qualitative Absorption Spectroscopy

First Grade Unit A: PHYSICAL SCIENCE Chapter 1: Observing Solids, Liquids and Gases Lessons 1 to 5

Unit 1 - Pure Substances and Mixtures Chapter 2: Solutions

TEACHER ACTIVITY GUIDE

Acousto-optic modulator

SEPARATION OF A MIXTURE OF SUBSTANCES LAB

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

Chapter Test A. Elements, Compounds, and Mixtures MULTIPLE CHOICE. chemically combined? MIXs2 a. element b. compound c. mixture d.

Standards A complete list of the standards covered by this lesson is included in the Appendix at the end of the lesson.

Upon completion of this lab, the student will be able to:

Hands-On Labs SM-1 Lab Manual

THE NATURE OF LIGHT AND COLOR

Both drink mixes contain similar basic ingredients, as listed in Table 1. Ascorbic acid (vitamin C) Ascorbic acid (vitamin C)

PHYSICAL SEPARATION TECHNIQUES. Introduction

Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.

Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs

AN OEM REFRACTOMETER FOR IN-LINE BRIX MEASUREMENT K-PATENTS SANITARY OEM REFRACTOMETER PR-33-AC SB:PR-33-AC/3

Experiment #4 Sugar in Soft Drinks and Fruit Juices. Laboratory Overview CHEM August 2010

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

Properties of Acids and Bases

Phenolphthalein-NaOH Kinetics

A PRIMER ON ph. A Presentation for ASTA Conference September 30-October 1, 2008

Dry Ice Color Show Dry Ice Demonstrations

1 of 9 2/9/2010 3:38 PM

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

AR200. Refractometer User s Guide. Page 1

I. ACID-BASE NEUTRALIZATION, TITRATION

Solubility Product Constants

8.2 Cells and Energy. What is photosynthesis? Photosynthesis takes place in the chloroplasts. CHAPTER 8. Solar cells and chloroplasts

2 Spectrophotometry and the Analysis of Riboflavin

Study Guide for Exam on Light

Determination of calcium by Standardized EDTA Solution

COLORIMETER. Description 0358BT. Figure 1. The Colorimeter

Photosynthesis and Light in the Ocean Adapted from The Fluid Earth / Living Ocean Heather Spalding, UH GK-12 program

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Acids and Bases. AND a widemouth container of the following solids:

Blackbody Radiation References INTRODUCTION

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

MAKING & FERMENTING THE MASH

b. In Laser View - click on wave. Pose an explanation that explains why the light bends when it enters the water.

Measurement and Calibration

EXPERIMENT 20: Determination of ph of Common Substances

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

Testing for Sugars and Starch

Return to Lab Menu. Acids and Bases in Your House

Composition of Grapes

1. At which temperature would a source radiate the least amount of electromagnetic energy? 1) 273 K 3) 32 K 2) 212 K 4) 5 K

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

ph and Acidity in Wine and Fruit Juice

Transcription:

About Coffee and Refractometers 2008-200 Voice Systems Technology, Inc. (VST) www.mojotogo.us.0 Coffee and Refractive Index Refractive Index measurements have been used for process control in the food industry since the 940 s. Typical measurements are usually for sugars in fruits, such as melons, orange and other juices, sugar content in grapes for the wine industry and many other examples. Refractive Index is directly related to the Total Dissolved Solids in solution of Coffee. To the best of our knowledge, no one has ever provided an easy to use, accurate and portable refractive index device calibrated specifically for coffees. Previous methods for TDS measurement of coffee include the oven drying dehydration method, which is slow and expensive but highly accurate, conductivity instruments which are difficult to calibrate and have proven unreliable and the hydrometer method, which is delicate, temperature sensitive and impractical in most environments. To provide a meaningful solution to this problem, VST has partnered with a world leading manufacturer of optical instruments to develop a state-of-the-art refractometer designed specifically for coffee, called the VST-Coffee Refractometer manufactured by Reichert Analytical Instruments. Reichert is a well known optical instrument manufacturer, and their products have won technical achievement awards for their innovative design, accuracy and practical use in the field for hundreds of applications.. Coffee Process Control and the importance of TDS in Quality Internationally accepted quality standards in the specialty coffee industry established [in the 950 s] that extraction of approximately 20% by weight of the ground coffee will achieve the best quality brewed coffee, using various brew methods. The precise extraction percent may be varied for particular coffees, along with the strength, to achieve finely tuned recipes for particular coffee cultivars, growing regions, climate, a.k.a.,terroir, and roast characteristics. Up to 30% of the available soluble solids in [ground] coffee can be extracted, with most of the remaining 70% being cellulose, and not soluble in water. However, generally speaking, extracting more than 2% will begin to sharply increase those components in coffee that contribute to bitter taste defects associated with overextraction. Extracting less than 8% is generally associated with weak, underdeveloped taste defects. In order to determine the actual level of extraction reached for a particular coffee batch, one must know the brew formula and the soluble solids in final solution, or Total Dissolved Solids (% TDS). The brew formula is simply the water amount by weight, and the ground coffee weight used in the batch.

The Brew Formula is expressed as a curve on a brewing control chart, seen as the green line in FIG., below. The TDS is measured using the VST-Coffee Refractometer at.30%, and plotted on the Brew Formula line in red. The percent extraction can then be read directly off the chart. In FIG., the extraction in this design example is exactly 20%. Another way of expressing this example is that 20% of 58 grams of coffee, or about.6 grams of coffee were extracted and dissolved into approximately 858 grams solution, or about.35% soluble solids in solution. FIG..2 Refractometers and Temperature The VST Coffee refractometer is temperature corrected. Each unit is tested for accuracy against a known standard and typically reads to an extrapolated accuracy of +/- 0.05% from 5-30 Deg C (although the warranted accuracy is +/-0.%). This is accurate enough for most applications for coffee in the field. Higher accuracy refractometers for research and laboratory use are available at www.mojotogo.us

Though temperature corrected, this does not mean that hot coffee placed on a cooler refractometer prism. Temperature correction means that the coffee sample and the instrument prism are stable at the same temperature, and in the temperature corrected range of 5 to 30 Deg C. Maintaining Accuracy In order to get the most accurate TDS measurements, one should calibrate the refractometer using deionized or distilled water stored at room temperature, along with the refractometer. Check the refractive index (nd) against a table for DI water at the temperature indicated when using the refractometer in its native mode (i.e., reading nd and TEMP). Then, cool the coffee sample to room temperature and transfer into the refractometer sample well, and allow time for the coffee sample and prism to reach the same temperature. Then take a reading. Therefore, in order to obtain best accuracy, do not take the refractometer out of your warm pocket or out of a cold car (in winter) and immediately expect it to work accurately. Allow time for the refractometer to reach ambient temperature and calibrate before use..3 Using the VST Coffee Refractometer When using the Coffee, and most other refractometers, the sample MUST be at the same temperature as the PRISM for an accurate measurement. Automatic Temperature Compensation (ATC) compensates for shifts in ambient temperature, not for the difference between coffee sample and prism temperature. Read the simple calibration and measurement technique sections, below, for an understanding of how to make accurate measurements. Calibrate Using Distilled Water Store the Refractometer and a container of distilled water at room temperature, and calibrate if there is a change in ambient temperature of more than a few degrees C. VST recommends calibration and use within a range of 5-30 Deg C, which should easily accommodate most room temperature conditions. Measurement Technique After brewing your coffee, be certain to stir the final solution before sampling. Then, pour a few grams of coffee into a clean and DRY glass or porcelain cup, allowing the cups mass to absorb thermal energy, and cool the sample. If necessary, transfer into a second glass, and allow to cool. When cooled to ambient temperature transfer the sample to the refractometer sample well using a pipette, using a few drops to completely cover the glass. Leave the sample on the prism for 5-30 seconds before taking an initial reading. This allows the sample to acclimate to the temperature of the prism. Check it a second time for a final reading.

Further Reading.4 What is Refractive Index? Refractive index is a property of any substance that slows the velocity that light propagates through it. From a practical standpoint, we see the effect of refractive index in the form of a beam of light bending as it traverses the interface between two mediums such as air and water. For this reason a straw looks like it bends when placed in a glass of water. As an illustration of the bending of light, consider the ray in FIG. 2 propagating at an angle of q in Medium which has an index of refraction of n. This ray bends to an angle of q 2 as it passes into a Medium 2 of index of refraction n 2. The mathematics that describes this amount of bending are given by Snell s Law according to n sin =!. ()! n2 sin 2 Medium 2, index n 2! 2 Medium, index n Light ray! FIG. Manipulating Eq. (), one finds that the refracted beam in Medium 2 travels at an angle q 2 according to & n # sin' ' = $! 2 arcsin. (2) % n2 " Therefore, the larger n and q are and the smaller n 2 is, the larger q 2 becomes. It should be noted that the index of refraction for all material changes with wavelength. In other words, the index of refraction of glass, water, coffee, or any other material is different (actually higher) for blue light than it is for red light. It is for this reason that water droplets in the sky create a rainbow from sunlight and why sunlight passing through the beveled glass of a window or through chandelier glass will create a spectrum of colors on the wall or floor of a room.

.5 What is a Refractometer? A refractometer is an instrument designed to measure the index of refraction of a sample of material such as coffee, water, glucose, or other liquid or gel. Since the index of refraction of any material changes as a function of the wavelength of light, refractometers generally measure the index of refraction of light at a wavelength close to 589.3 nm, which is yellow light. In the food industry, refractometers are used to measure solution concentrations, where these solutions can include soft drinks, fruit juices, tea, and coffee. For any of these solutions, as more material (sugar or other solids) are added to water, the index of refraction increases. By correlating how the percent solids for a particular solution changes the index of refraction, the measurement of index of refraction can later be used to determine the percent solids or TDS in a given solution. Note that in the food industry, it is common to typically refer to the degree Brix of a given solution. Strictly speaking the º Brix is only accurate for a solution composed strictly of sucrose and water, as it is a measure of the percent sugar by weight in a sugar-water solution (eg., a solution with 0 gm sugar and 90 gm water is a 0% sugar solution and therefore a 0 º Brix solution). For other solutions that contain sugar as well as other solids, as is the case for coffee, the Brix scale is not accurate and requires a new correlation to a known set of reference solutions. Separate correlations exist for sucrose, glucose, fructose, invert sugars, high fructose corn syrups and hundreds of other solutions. Physically a refractometer is composed of a light source, a prism, and a linear detector array. As illustrated in FIG. 3, an illumination lens is used to direct the light from the light source to the prism and a collection lens collects the light that is reflected from the prism-sample interface and directs it towards the linear detector array. In modern digital refractometers the light source is typical a semiconductor laser or LED at about 589.3 nm (yellow light). The purpose of the illumination lens is to create a focusing beam or cone of light incident upon the prism-material interface that ranges in angles of incidence between q min and q max. The critical angle q c of the prism-sample interface must be such that q min < q c < q max, where q c is the angle q at which q 2 becomes 90º. From Eq. (2), in order for q 2 = 90º, the argument of the arcsin on the right hand side of the equation must equal unity. Using n 2 = n for the index of refraction of the material under test and n p = n for the index of refraction of the prism, the critical angle can be expressed as ( n / n ) arcsin( n / )!. (3) c = arcsin 2 = n p Historically yellow light of a wavelength of 589 nm is used because before lasers were invented, scientists could generate such pure yellow light using a sodium arc lamp. These yellow lamps are sometimes seen today to illuminate parking lots or alleys at night.

Sample material under test of unknown index n prism Illumination lens! max! min Linear detector light source n p Collection lens x = x max x = x c x = 0 FIG. 3 A unique property of the critical angle is that for all angles larger than q c, 00% of the light is reflected from the interface and none transmits. For angles inside of the prism that are less than q c some light transmits into the sample material and therefore less than 00% of the light is reflected. In other words, for all rays in the beam of light focusing in the prism that are greater than the critical angle, 00% of the light is reflected off of the prism-material interface and propagates towards the collection lens and then on to the linear detector. The ray that is incident upon the prismsample interface at q c will strike the linear detector at a point x = x c. By analyzing the detected light levels from x = 0 to x = x max on the detector, the software of the refractometer detects the position x c since for x c < x < x max, the light level is constant across the detector array (cannot get any more than 00% of the light reflected!). With a well-calibrated refractometer, the detector position x c is mapped back to a critical angle q c, which from Eq. (3) and knowing the index of refraction of the prism n p, the index of refraction n of the sample can be calculated and reported. In addition to being wavelength sensitive, the index of refraction for any material changes slightly with temperature. For coffee at 20ºC the index of refraction is ~.3353 and changes by -0.000 for every degree C. This may not seem like much, but for a 5ºC change in temperature of a coffee solution, the measured index of refraction will change by -0.0005 and the reported TDS value will change by 0.25% if thermal affects are not accounted for.

The following material is Copyright 2008 Westover Scientific, Inc. What is ATC? (from www.refracts.com/faq.htm) ATC is an abbreviation for automatic temperature compensation. ATC allows the user to take accurate scale readings at varying ambient room temperatures. Benefits of ATC: Without ATC, if the temperature of the room changes by a degree or two, the refractive index shifts. The scale is only accurate for the temperature at which calibration was done. ATC allows the refractometer to maintain accuracy at a wider range of ambient temperature shifts (between 20-50 degrees Celsius). So ATC refractometers require calibration much less often than models without automatic temperature compensation. Temperature of the sample: The sample MUST be the same temperature as the prism for an accurate reading. ATC compensates for shifts in ambient temperature, not for the difference between sample and prism temperature. If you are working with samples at a temperature different than the ambient room temperature, leave the sample on the prism for 30 seconds before taking the reading. This allows the sample to acclimate to the temperature of the prism Ambient air temperature: ATC models are best suited for settings where the room's air temperature may vary more than one degree. Even as much as a single degree of temperature variation can affect the reading of a refractometer without ATC.