Fisher FIELDVUE DVC2000 Digital Valve

PRODUCT PROFILE FEATURES

Compact pressure switch Flameproof enclosure Ex d Model PCA

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

LSB Series. Valve Position Monitor. All innovation on driving your valve automation

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

Centro-Matic Automatic Lubrication Systems System Controls

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Rosemount 751 Field Signal Indicator

B-Series Temperature Switches

Micro Motion 3098 Gas Specific Gravity Meter

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

KNC Model 3666 Automatic Pressure Calibration System

4-20 ma Transmitters Alive and Kicking

Solenoid Valve Island Type 3965

Proximity Transmitters and Seismic Vibration Transmitters

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

Microcor Wireless Transmitter (MWT)

Digital inductive conductivity transmitter

Worcester DS/DM Series UltraSwitch Switch box

Series 3730 Type Electropneumatic Positioner with FOUNDATION fieldbus communication

High-precision valve control using intelligent positioners. sipart

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

PIEZOMETER AIRFLOW MEASURING RING

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Experience In Motion. Valtek Spring Cylinder Linear Actuators

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

2 & 5-Wire Overfill Sensors

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Series 3730 Type Electropneumatic Positioner

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Model 43AP Pneumatic Controller, Style B

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Control- and feedback head for integrated mounting on Robolux valves Type 2036

B-Series Switches Pressure, Differential Pressure & Hydraulic

Flow switches Series AD/VH

Fisher 846 Electro-Pneumatic Transducer

TEIP11 I/P signal converter for standard signals. Measurement made easy

Fisher 377 Trip Valve

2.12. page Products for Explosion hazardous Environment

Technical Data. Dimensions

Electronic Pressure Switches

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices

Linear Luminaire with LED Series EXLUX 6402/2

Model 111 Mass Flow Instruments

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Model 3051 Pressure Transmitter with HART Protocol

Rosemount 333 HART Tri-Loop

4 Posiflow Proportional Solenoid Valves

nvision Reference Recorder

Fisher 657 and 667 Diaphragm Actuators

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Everything you need for protection scheme testing

Rosemount 752 FOUNDATION fieldbus Remote Indicator

3DLevelScanner II TECHNICAL DATA SHEET

Explosion proof enclosures

M-series FOUNDATION Fieldbus I/O

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Gas Turbine Fuel Control Valve

Software and Display instruments

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

The L&J Engineering Model MCG 1500SFI Servo Gauge

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Rosemount 333 HART Tri-Loop

Fisher 4320 Wireless Position Monitor, with On/Off Control Option

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Technical Data Sheet. 3DLevelScanner

Rackmount Intelligent Pressure Scanners

RM7000 TC with Internal Pulser

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ordering Part Numbers:

Transcription:

ICoT Smart Positioners Intrinsically Safe, Explosionproof - ATEX/IEC/INMETRO Smart positioners with a single design to suit both springreturn and double-acting actuators for rotary and linear valves. Available with HART communication protocol, FOUNDATION Fieldbus and Profibus PA network capability. Technical data Agency approvals Intrinsically safe Area classification (ATEX/IEC/INMETRO) 5000 series Ex ia IIC T4 Enclosure standards (IEC) 5000 series IP66 Explosionproof Area classification (ATEX/IEC/INMETRO) 6000 series Ex d II T5 Ex d IIIC T85 C: II 2 D Ex d tb IIIC T85 C Enclosure standards (IEC) 6000 series IP65 Enclosures 5000 series Engineered resin 6000 series Aluminum Stainless steel Communication protocol 5200 None 5300/6300 HART 5400/6400 FOUNDATION Fieldbus 5500/6500 Profibus PA Features 3-button interface and graphical LCD for easy calibration and information display. Easy configuration of split range and reverse acting operation. Easy access to wiring terminal connectors Non-contact valve position measurement via Hall effect sensor. Eliminates the need for drive arms, linkages and increases overall resolution, accuracy and reliability. Advanced auto-calibration. Valve speed adjustable via user control. Available with optional dry contact limit switches. Optional 4-20 ma position feedback transmitter - HART version only. High-flow spool valve option for larger actuator/valves. Eliminates the need for volume boosters in some applications. Highly visible position indicator for rotary applications. Easily accommodates large stroke valves, such as knife gates. Fully compatible with AMS software and DTM. Rugged aluminum and stainless steel enclosures for maximum protection - 6000 series. Engineered resin enclosure is robust yet lightweight with exceptional chemical, UV and impact resistance - 5000 series. www.westlockcontrols.com WESTDS-09072-EN-1306

ICoT Smart Positioners Intrinsically Safe, Explosionproof - ATEX/IEC/INMETRO Non-contact position feedback Unlike conventional positioners, the ICoT feeds back accurate valve position without the need for linkages, levers and rotary or linear seals. Position sensing is performed by a non-contact sensor, employing Hall effect magnetic principles. This enables the use of advanced control strategies where knowledge of valve position is used in predictive and other algorithms. Rotary control There is no hysteresis within the positioner. This feature allows extremely accurate tracking of the control signal to within 0.1 ma. The non-contact position sensor is embedded within the ICoT housing. An external magnetic module, attached to the output shaft of the actuator and housed in the beacon assembly, rotates about this sensor. An analog-to-digital converter interfaces between the sensor and a microprocessor. It rotates about this sensor generating position signal which is linearized to improve accuracy and linearity of the controlled position commanded by the instrument signal. ICoT on a typical linear diaphragm valve Linear control The ICoT proximity positioner provides more reliable measurement of valve stem position. A static slide-by actuation assembly, attached to the valve stem, is the only moving part. Output updating takes place twenty times per second. ICoT is a fully digital positioner allowing for multiple control algorithms leading to better controllability for a large range of actuators and enables a wide range of diagnostic information to be generated. Traditional ICoT eacon Remote mount capability The ICoT has the ability to be mounted remotely (up to 15 m) from the device it is controlling (Please consult about greater distances). This allows the positioner to be isolated if the control valve is located in either a high vibration or extremely corrosive environment. NAMUR style eacon Pipe mount ICoT with remote and cable set Page 2

ICoT Smart Positioners Intrinsically Safe, Explosionproof - ATEX/IEC/INMETRO Negligible bleed The ICoT 5000/6000 series positioner is designed to consume the least possible amount of control air at steady state. This means lower process air consumption and reduced demand on instrument air compressors. To increase reliability, the ICoT employs a patented lapped spool and floating sleeve design. This balanced construction relies on an air bearing which eliminates any metal-to-metal contact and results in a mean time between failures (MTF) of 1,666,666.7 hours or 333.3 years. Integrated position transmitter The ICoT 5200/5300 and 6300 series are available with an integrated 4-20 ma position feedback transmitter. This cost-effective feature eliminates the need to buy externally mounted devices when knowledge of valve position is required remotely. AutoCal intelligent calibration, local keypad ICoT intelligent positioners are equipped with a 3-button keypad for performing on-site electronic calibration. System calibration is performed easily, requiring only minutes to accomplish. It offers the operator a choice of linear, quick-opening or equal percentage modes. Split range and reverse acting operation are also configured simply. The AutoCal feature allows simple zero and span adjustments as well as PID and transducer calibration. The 5300/6300 and 5400/6400 series offer the option of HART or FOUNDATION Fieldbus respectively, with the 5500/6500 suitable for Profibus PA. On-board sensors/error detection The ICoT positioner has the capability to constantly monitor its own operation. If an error or failure condition occurs, it will be displayed on the local LCD. If the positioner is supplied with a HART interface, the error codes will be displayed on a hand-held terminal or PC maintenance station as shown below: Err3 = Low input pressure Err6 = Calibration error Westlock Controls ICot HART Rev 1.02.00 25.5 C R %PS 56.4 %SP 56.4 12.0mA ERR3 The alarm conditions and additional diagnostic capabilities are provided through a number of sensor elements in the transducer. A pressure switch detects low air pressure entering the positioner. In conjunction with a supply pressure switch, it can be identified whether this is caused by a restricted filter or a genuine low supply pressure condition. A 0-100% position feedback transmitter is available integrated within the electronics of the ICoT 5200 and 5300/6300 series positioners. Local LCD display The local LCD display provides a range of on-site diagnostic information. While the valve is being controlled by the positioner and the error signal is NOT zero, the displayed information will show both setpoint and position as a percentage. The range of values displayed is from 0.0% (fully closed) to 100% (fully open). The resolution displayed is in 0.1% increments although internal calculations are maintained more precisely. PID control The ICoT uses proportional, integral and derivative functions, making it a true PID servo system. y combining intelligence based on present, past and the prediction of future events, the ICoT s controller is able to minimize errors and provide a precise control response. Autotuning Westlock Controls ICot HART Rev 1.02.00 25.5 C R %PS 56.4 %SP 56.4 12.0mA ACAL Tuning, or setting of the PID functions, is carried out automatically by the microprocessor within the ICoT. This eliminates complex and time-consuming manual procedures. 5300/6300 series HART protocol The ICoT 5300/6300 series positioner responds to HART commands for ease of calibration and provides intelligence for the control valve through a microprocessor-based diagnostic system utilizing the HART protocol. 5400/6400 series FOUNDATION Fieldbus protocol The ICoT 5400/6400 series features the FOUNDATION Fieldbus communication protocol, is an industry proven international standard (IEC 61158) designed for use in the process industry. Its features include multidrop capabilities (as many as 32 devices per segment), extended trunk length, and single loop integrity. It also offers control in the field, power and communications on a shielded twisted pair network and compatibility with intrinsically safe networks. A key feature of the FF protocol is the ability to select where control of the process is situated in the host, in the field or in various combinations of both locations. 5500/6500 series Profibus PA protocol The ICoT 5500/6500 series features the Profibus PA communication protocol. Similarly to the Foundation Fieldbus devices, Profibus PA (Process Automation) physical layer confirms to the IEC61158-2 international industry proven standard allowing for multi-drop communication to 32 devices per segment and extended trunk length. ICoT 5500/6500 is an intrinsically safe positioner utilizing single, twisted pair shielded cable for power and communication. Functional advantages include transmission reliability, self-test functions, diagnostic, distributed intelligence, local and remote auto-calibration. To simplify integration of ICoT 5500/6500 positioners Westlock provides GSD (General Station Description) containing key device data as well as EDD (Electronic Device Description) and DTM (Device Type Manager). Page 3

ICoT Smart Positioners Intrinsically Safe, Explosionproof - ATEX/IEC/INMETRO ICoT 5300/6300, 5400/6400 and 5500/6500 series intelligent positioners with HART, FOUNDATION Fieldbus and Profibus PA network capabilities Proven, Interoperable solutions even in the Harshest Environments The ICoT positioner series has been successfully used for more than 15 years in many challenging and diverse applications in industries such as, Oil and Gas, Chemical, Power, Pulp and Paper and Sugar and Ethanol. Although it has a proven track record, Westlock is constantly improving the ICoT line of positioners. Recent developments have enhanced the ICoT electronics robustness and performance even when submitted to vibration and EMI. In the mechanical arena, an explosion proof solution and stainless steel housing option is now available. Software upgrades ensure the ICoT series is up to date with the most recently released industry standards, like the FF s ITK 6.0.1 (one of the first in the market) and the new 5500/6500 series is now compatible with the Profibus PA protocol. Our goal is to provide the ICoT user with a truly open, independent and interoperable solution able to interface with different host system brands and vendors. In order to support the integration of ICoT positioners in to the user s host system of choice, you can download all the necessary HART, Fieldbus Foundation or Profibus files from our website. Please visit www.westlockcontrols.com to find : ICoT 5300/6300 (HART): - EDD (also available at http://www.hartcomm.org in the Product Catalog - Wired Products menu) - DTM(available also at http://www.fdtgroup.org in the Product Catalog Certified DTM s catalog) ICoT 5400/6400 (Foundation Fieldbus) - EDD (available at www.fieldbus.org in the End User Resources Registered Products) ICoT 5500/6500 (Profibus PA) - EDD (available at http://www.hartcomm.org in the Product Catalog - Wired Products menu or at http://www.fdtgroup.org in the Product Catalog Certified DTM s catalog) Additional features and benefits The ICoT 5300/6300, 5400/6400 and 5500/6500 series provide intelligence to the control valve through microprocessor-based systems using the HART, FOUNDATION Fieldbus TM and Profibus PA protocols respectively. These offer additional benefits in intelligent calibration, control and on-line diagnostics. Intelligent calibration Accurate measurement of valve stem position, input signal, actuator pressure, cycle time and cycle count data are recorded during normal operation, providing information for control valve signature generation. The positioner has a local LCD display which indicates valve position, setpoint in percentage open, calibration status, alarms status and, for the 5400/6400 (FF) and 5500/6500 (PA), whether the ICoT is in local or fieldbus control. Intelligent control Control valves are the most maintenanceintensive components commonly used in instrumentation and control systems. Internal parameter sensing within the valve positioner gives early warning of the need for maintenance. On-line diagnostics The ICoT possesses the capability to predict rather than react to valve maintenance needs. Operating personnel gain a real time perspective on the state of control at the valve, including a view of operating integrity and emerging alert conditions. Timely information about each control valve s condition is quickly made available to the plant s production and maintenance engineers. The principal advantage of online diagnostics is the ability to detect deviations from established patterns of behavior as they occur under actual operating conditions. The ICoT positioner s diagnostic capability observes the following parameters: Valve position vs. input signal. Actuator pressure vs. valve position. Airset filter outlet pressure. Confirmation of principal operating pressures within the positioner. Pressure generation within packing gland area. These enable the following to be diagnosed: - Stick-slip detection. - Excessive static position error. - Low air supply pressure. - Clogged air supply filter. - Restricted transducer nozzle. - Transducer diaphragm air leak. - Non-functioning spool valve. - Calibration error Page 4

ICoT Smart Positioners Intrinsically Safe, Explosionproof - ATEX/IEC/INMETRO Hand-held terminals Model 5300/6300 A single 4-20 ma ICoT positioner with up to two master devices may be connected to each HART loop. The primary master is generally a management system or a PC while the secondary unit can be a handheld terminal or laptop computer. ICoT Positioner I. S. arrier 250 Power Supply A standard hand-held HART Communicator is available for making field operations as uniform as possible. Communication is accomplished by superimposing a high frequency signal on top of the 4-20 ma output signal. This allows simultaneous communication and output without comprising loop integrity. Model 5400/6400 Foundation Fieldbus compatible hand held terminals (like the Rosemount Field Communicator) can communicate with the ICoT 5400/6400 series smart positioners via the FF protocol. ICoT Positioner I. S. arrier Engineering Station Host system ICoT Positioner ICoT Positioner Model 5500/6500 Similar to the Fieldbus Foundation, a Profibus PA tester, like the MTL FT6-PA, can be used in hazardous areas. Several testers and bus analyzers are also available to be used directly from the DP network in the safe area. ICoT Positioner I. S. arrier Engineering Station ICoT Positioner Controller / Interface + DP/PA coupler PA Tester ICoT Positioner Page 5

ICoT 5000 Series Positioners Intrinsically Safe - ATEX/IEC/INMETRO Technical specifications Electrical 5200/5300 5400 5500 Input signal 4-20 ma Two wire FOUNDATION Fieldbus Two wire Profibus PA Minimum voltage 9.0 V DC 9.0 V DC 9.0 V DC Maximum voltage 30.0 V DC 32.0 V DC 32.0 V DC Impedence 450 ohms at 20 ma N/A N/A Reverse polarity protection Yes Polarity insensitive Polarity insensitive Pneumatic 5200/5300/5400/5500 Supply pressure* 15 to 45 psi (low pressure option) 40 to 120 psi (high pressure option) Output flow rate 8.0 scfm @ 25 psi 16.2 scfm @ 90 psi Air consumption 0.03 scfm @ 20 psi (low) 0.08 scfm @ 90 psi (high) High flow option 40 scfm @ 90 psig supply 10% to 90% non-condensing Technical 5200/5300/5400/5500 Linearity ± 0.5% Rotary ± 1.0% Linear (for travel under 1.25") Valve travel Rotary: Minimum 45, Maximum 95 Linear: Minimum 0.25", Maximum 48" Hysteresis 0.2% of span Repeatability 0.2% of span Environmental 5200/5300/5400/5500 Operating temperature -40 F to +185 F [-40 C to +85 C] Thermal coefficient 3% / 100 C Mechanical 5200/5300/5400/5500 Connections Pneumatic: ¼" SP (F) (⅜" SP (F) for High Flow version) (NPT optional) Electrical: M20, ½ NPT (F) optional Materials of construction Enclosure: Nylon, glass filled Cover gasket: Silicone Pneumatic manifold: Aluminum anodized die cast zinc Pneumatic seals: NR Weight 3.27 Kg (7.2 pounds) Optional features 5200/5300/5400/5500 Airset Filter regulator combo with 5 micron filter element Limit switches Two SPST hermetically sealed switches (rated for 2 A at 24 V DC) 5200/5300 Feedback transmitter 4-20 ma output (loop powered) * As required by actuator for proper control Page 6

ICoT 5000 Series Positioners Intrinsically Safe - ATEX/IEC/INMETRO Dimensions rotary control 1/4 NPT OR 1/4 SP 3 PLC s 3.58 [90.94] 2.19 [55.60] 1.50 [38.19] 1.25 [31.78].94 [23.82] 6.79 [172.59] 4.49 [114.11].60 [15.26] 2.19 [55.68] 3.29 [83.65] 3.42 [86.85] SIDE VIEW 7.87 [199.99] 5.01 [127.33] TOP VIEW 5/16-18 x.35 DP OR M8 x 1.25 (4 PLC s) 4.55 [115.53] 1/2 NPT (M20 OPTIONAL) 3.00 [76.28] 1.38 [34.96] 2.15 [54.66] 3/4 NPT (2 PLC s) 4.30 [109.33] OTTOM VIEW Dimensions in inches, where available metric dimension (mm) in parentheses. Note: Product shown is standard flow variant Dimensions rotary control with switches 2.19 [55.68].60 [15.26] 3.29 [83.65] 7.87 [199.99] 1/4 NPT OR 1/4 SP 3 PLC s 5.46 [138.79] 5.23 [132.89] 4.96 [126.04] 4.71 [119.69] 3.58 [90.94] 2.19 [55.60] 1.50 [38.19]1.25 [31.78].94 [23.82] 7.98 [200.63] 6.79 [172.59] 4.49 [114.11] 5/8-18 UNF TH D 2 PLC s 3.42 [86.85] SIDE VIEW 2.62 [66.57] 5.01 [127.33] 5/16-18 x.35 DP OR M8 x 1.25 (4 PLC s) TOP VIEW 1/2 NPT (M20 OPTIONAL) 4.55 [115.53] 3.00 [76.28] 1.50 [38.14].69 [17.49] 1.08 [27.53] 2.17 [55.07] 1.38 [34.96] 3/4 NPT (2 PLC s) 2.15 [54.66] 4.30 [109.33] OTTOM VIEW Dimensions in inches, where available metric dimension (mm) in parentheses. Note: Product shown is standard flow variant Page 7

ICoT 5000 Series Positioners Intrinsically Safe - ATEX/IEC/INMETRO Dimensions linear control 1/4 NPT OR 1/4 SP 3 PLC s 3.58 [90.94] 2.19 [55.60] 1.50 [38.19] 1.25 [31.78].94 [23.82] 6.79 [172.59] 4.49 [114.11].73 [19].50 Ø [13].60 [15.26] 2.19 [55.68] 3.29 [83.65] 3.42 [86.85] SIDE VIEW 7.87 [199.99] 5.01 [127.33] TOP VIEW 5/16-18 x.35 DP OR M8 x 1.25 (4 PLC s) 4.55 [115.53] 1/2 NPT (M20 OPTIONAL) 3.00 [76.28] 1.38 [34.96] 2.15 [54.66] 3/4 NPT (2 PLC s) 4.30 [109.33] OTTOM VIEW Dimensions in inches, where available metric dimension (mm) in parentheses. Note: Product shown is standard flow variant Page 8

ICoT 5000 Series Positioners Selection Guide ase model 52 53 54 55 Intelligent positioner Intelligent positioner with HART capability FOUNDATION Fieldbus positioner Profibus PA positioner Actuator type 1 3 Linear (Free magnet assembly include up to 2½ stroke; for strokes > 2½, contact your sales representative) Rotary Mounting style 0 5 7 8 Direct mount (lcot mounted on actuator) Remote mount (ICoT mounted remote from actuator) NAMUR mount (order with stainless NAMUR mounting kit separately) ModMount (for Keystone MRP and 79U actuators only; supplied with mounting kit) Hazardous rating AI II Intrinsically Safe - ATEX EX ia IIC T4 approved Intrinsically Safe - IEC Ex ia IIC T4 approved Housing material E Engineered resin Supply pressure H L V S High pressure (40-120 psi) Low pressure (15-45 psi) High flow (40-120 psi for larger actuators) Super high flow (40-120 psi, 5.5 C v ) Calibration/communication K F Via 3-utton on-board keypad (Series 52 only) 3-utton on-board keypad and Hart protocol (Series 53 only) 3-utton on-board keypad and Fieldbus protocol (Series 54 only) Conduit entry A One ½ NPT (F) One M20 (F) Limit switch options 0 2 None Two SPST hermetically sealed (Mounting style 0 only) Position transmitter output A None 4-20 ma transmitter (Series 52 and 53 only) Pneumatic connections N F ¼ NPT ( 3 /8 NPT with high flow option) ¼ SP ( 3 /8 SP with high flow option) ¼ NPT with filter-regulator assembly ( 3 /8 NPT with high flow option) 53 3 5 IS E H A 0 N = Model number 5335ISEHA0N Notes Specifying your positioner Specifying a positioner is a complex process as there are many variables, which affect each application. To ensure you receive the best possible positioner for your application, please contact your local sales office for advice and guidance from one of our experts. Hazardous area classification Please see our data sheet for further information on the global standards affecting the specification and installation of equipment in hazardous areas. Page 9

ICoT 6000 Series Positioner Explosionproof ATEX/IEC/INMETRO Technical specifications Electrical 6300 6400 6500 Input signal 4-20 ma Two wire FOUNDATION Fieldbus Two wire Profibus PA Minimum voltage 9.0 V DC 9.0 V DC 9.0 V DC Maximum voltage 30.0 V DC 35.0 V DC 35.0 V DC Impedence 450 ohms at 20 ma N/A N/A Reverse polarity protection Yes Polarity insensitive Polarity insensitive Pneumatic 6300/6400/6500 Supply pressure* 15 to 45 psi (low pressure option) 40 to 120 psi (high pressure option) Output flow rate 8.0 scfm @ 25 psi 16.2 scfm @ 90 psi Air consumption 0.03 scfm @ 20 psi (low) 0.08 scfm @ 90 psi (high) High flow option 40 scfm @ 90 psig supply 10% to 90% non-condensing Technical 6300/6400/6500 Linearity ± 0.5% Rotary ± 1.0% Linear (for travel under 1.25") Valve travel Rotary: Minimum 45, Maximum 95 Linear: Minimum 0.25", Maximum 48" Hysteresis 0.2% of span Repeatability 0.2% of span Environmental 6300/6400/6500 Operating temperature -40 F to +185 F [-40 C to +85 C] Thermal coefficient 3% / 100 C Mechanical 6300/6400/6500 Connections Pneumatic: ¼" NPT (F) (⅜" NPT (F) for High Flow version) Electrical: ½" NPT (F) (M20 optional) Materials of construction Enclosure: Aluminum Stainless steel Cover gasket: Silicone Pneumatic Anodized aluminum and 316 stainless steel manifold: Pneumatic seals: NR Weight 7.2 pounds Optional features 6300/6400/6500 Airset Filter regulator combo with 5 micron filter element Limit switches Two SPST hermetically sealed switches (rated for 2 A at 24 V DC) 6300 Feedback transmitter 4-20 ma output (loop powered) * As required by actuator for proper control Page 10

ICoT 6000 Series Positioner Explosionproof ATEX/IEC/INMETRO Dimensions rotary control / linear control cover lock screw 4x 1/4-20 unc ground screw 3.29 [83.4] squ sight glass for lcd/data viewing 3.36 [85.3] squ 4.25 [108.0] squ 2.31 [58.7].46 [11.7] 2x optional 1/2 npt or m20 6.50 [165.1] 1 1.765 [44.83] 5.01 [127.2].50 [12.7] coupler engagement 1.125 [28.58] squ ø 3.75 [95.2] view a-a shown with beacon for rotary applications 3x 1/4 NPT or 1/4 SP 3x.45 [11.5] 4.25 [108.0] 3x.30 [7.6] 3.14 [79.7] 2x 3.18 [80.7] 3x.60 [15.4] 2.10 [53.4] 2x 1.27 [32.1].47 [11.8].96 [24.4].64 [16.3] 1.53 1.27 [38.8] [32.4] 3x.31 [8.0] 3x non intrusive calibration blind hole.54 [13.6].54 [13.6] section b-b.89 [22.6].70 [17.8] 4.94 [125.4] approx. 1.80 [45.8] 6.58 [167.1] approx. 9.82 [249.4] approx. note: 1.115 [2.92] spacing is required for clearance between inner beacon & bottom of housing view shown w/o beacon for linear applications Dimensions in inches, where available metric dimension (mm) in parentheses. Note: Product shown is standard flow variant Page 11

ICoT 6000 Series Positioners Selection Guide ase model 63 64 65 Intelligent positioner with HART Capability FOUNDATION Fieldbus positioner Profibus PA positioner Actuator type 1 3 Linear (Free magnet assy. included up to 2-½ stroke length; stroke lengths over 2-½ please consult with your sales representative) Rotary NOTE: Linear valve stroke length and fail position must be specified at time of quotation. Mounting style 0 5 6 Direct mount (lcot mounted on actuator) Remote mount, aluminum housing (lcot mounted remote from actuator) Remote mount, stainless steel 316 housing (lcot mounted remote from actuator) Hazardous rating XP AX IX MP MI MN Explosion proof - Class I, Div, 1, Class 1, Zone 1 - AExd/Exd North America Flame proof - ATEX EX D II+H2 T5 approved Flame proof - IECEx EX D II+H2 T5 approved Explosion proof - INMETRO Ex d IIC T6 Gb Intrinsically Safe INMETRO Ex ia IIC T4 Gb Non-sparking INMETRO Ex na II T4 Housing material A S Aluminum copper free Stainless Steel 316 Supply pressure H L V STD flow high pressure (40-120 psi) LSTD flow low pressure (15-45 psi) High flow (40-120 psi, for larger actuators) Calibration/communication (external calibration standard) F 3-utton on-board keypad & Hart protocol (Series 63 only) 3-utton on-board keypad and Fieldbus protocol (Series 64/65) Conduit entry A ½ NPT (F) M20 (F) Limit switch options 0 None Position transmitter output A C None 4-20 ma transmitter (Series 63 only) Discrete output (Alarm/PST/SO Series 64/65 only) Pneumatic connections N F ¼ NPT ( 3 /8 NPT with high flow option) ¼ SP ( 3 /8 SP with high flow option) ¼ NPT w/ filter-regulator assembly ( 3 /8 NPT with high flow option) Pressure gages options N M No gages installed Gages installed 63 3 0 XP A H A 0 F M = Model number 6330XPAHA0FM Notes Specifying your positioner Specifying a positioner is a complex process as there are many variables, which affect each application. To ensure you receive the best possible positioner for your application, please contact your local sales office for advice and guidance from one of our experts. Hazardous area classification Please see our data sheet for further information on the global standards affecting the specification and installation of equipment in hazardous areas. Page 12