Testing of installations in road tunnels.

Similar documents
About us. Eugensa is an ISO 9001:2008 certified company. CERT

MARULENG LOCAL MUNICIPALITY

Trains crossing at Toronto s Old Mill Station 2009 TTC. Train Control

REVIEWED ICT DATA CENTRE PHYSICAL ACCESS AND ENVIROMENTAL CONTROL POLICY

water is cooled in a secondary cooling control tasks: use of seawater. Treatment of the seawater formation of algal vegetation.

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

Traffic Management During Construction

WATER / WASTEWATER & POWER PROJECTS LAST 5 YEARS. No of Staff Provided by BCE. Overall Project Value (SR)

Motorway Incident Detection and Automatic Signalling (MIDAS)

DC Cook Plant Process Computer Replacement Project

Cabling & Connectivity

Building Commissioning

HIGHLY SOPHISTICATED MONITORING

PRT_INCIDENT DETECTION_TRAFFIC

Data Center Commissioning: What you need to know

URBAN. Security Solution. Urban Security Solution Military Security Solution SOC Security Solution

Advanced Transportation Management Systems

Automation and control

Railway Crossing Information System

Definition of safety functions Application to degraded operating modes and minimum operating requirements

Safety Requirements Specification Guideline

BRO Roles & Responsibilities Form Page 1 of 9

WITH HIGH SPEED TO A SAFE EMERGENCY HANDLING - VIENNA - ST. PÖLTEN TUNNEL HIGH-SPEED LINE

Alain Nifenecker - General Electric Manager Controls Engineering

DATA CENTER PHYSICAL INFRASTRUCTURE

Online Training Certifications

CalMod Design-Build Electrification Services

Up-to-Date with Electrical Equipment

Integration of PTC and Ride Quality Data. Presented by: Wabtec Railway Electronics, I-ETMS PTC Supplier. and

How To Ensure Security At A Site Security Site

The Access Engine. Building Integration System - The Access Engine. Security Systems

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

Combined Cycle Control Overview

Quality of Service in Industrial Ethernet Networks

CHARM. Advanced Traffic Management System.

LB Sky Global. 92 Lobachevskogo St, Bld 92, Office 5, Moscow, Russia Tel/Fax 7(495) , Site:

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

Scope: Communications and Electronic Systems addressed in this section include:

SCC. Centralized traffic control system for lines and area junctions

Bringing open IP benefits to physical access control AXIS A1001 Network Door Controller

CONGESTION AND INCIDENT MANGEMENT APPLICATIONS FOR DISTRIBUTED ACOUSTIC SENSING TECHNOLOGY NZTA CASE STUDY

Axis video encoders. Where analog and network video meet.

Certificate of Registration

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

SECTION SYSTEMS INTEGRATION TESTING

a l A a l l i e v r l o r t a l l i e v r G e t a r a l g r u d i V e v i s s a l a u t r i V s s c c d i V e v i t c A l a u t r i V

Incident Handling in Complex Motorway Tunnels, Stockholm

Special Specification 6033 Computerized Transportation Management System

Industry Overview. Transportation

Vindicator Security Solutions. Security for Mission-Critical Applications

Bluetooth Web Enabler

AXIS 262+ Network Video Recorder

The Quality Connection. BETAflam Fire Resistant Safety Cables

A new radio system for the German coast

Efficient remote access to machines and plants with SIMATIC

Appendix A - Cost Estimate Spreadsheet

FREE FLOW TOLLING CASE STUDY M50 BARRIER-FREE TOLLING. Dublin-Ireland

Datacentre Capability March 2015

Configuring the Avaya B179 SIP Conference Phone with Avaya Aura Communication Manager and Avaya Aura Session Manager Issue 1.0

UBC Technical Guidelines Section Edition Secure Access: General Standards Page 1 of 7

Project Scheduling by Critical Path Method (CPM)

Austin Independent School District Police Department Policy and Procedure Manual

Sensitivity Analysis of Safety Measures for Railway Tunnel Fire Accident

Network Design Incorporated

SCADA. The Heart of an Energy Management System. Presented by: Doug Van Slyke SCADA Specialist

ZTE Smart City Solution Athens, 10 th of April Dimosthenis Zografos Technical Sales Manager in ZTE Hellas

OPTIMAL COMMUNICATION BACKBONE DESIGN FOR A TYPICAL LRT URBAN TRANSPORTATION CASE

Version: Modified By: Date: Approved By: Date: 1.0 Michael Hawkins October 29, 2013 Dan Bowden November 2013

Efficient servicing. Easy maintenance. High level of uptime.

NKS, New Karolinska Solna. -A new university hospital in Stockholm

Submarine Power Cables. State-of-the-art production facility, more than 100 years of experience and reference installations around the world.

ROAD WEATHER AND WINTER MAINTENANCE

World s Greenest High Performance Data Center

White Paper. Telenor VPN

integrated fire and security solutions Maximum protection for buildings

A Systems Approach to HVAC Contractor Security

Overview of Fire Alarm Systems and Maintenance

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Passion for Innovation

About LLC SpecCityStroy

Building Integration System Selection Guide for V4.0

How To Use A Network Video Recorder For Video Surveillance

SOFTWARE-IMPLEMENTED SAFETY LOGIC Angela E. Summers, Ph.D., P.E., President, SIS-TECH Solutions, LP

Security Systems Intrusion Alarm

How to Program a Commander or Scout to Connect to Pilot Software

Data Centre Services. JT First Tower Lane Data Centre Facility Product Description

Q. Why have we set up an energy centre and heat network in Bunhill?

DATACENTER COLOCATION. Flexible, Secure and Connected

Mechanical &Electrical Services Modernisation. Presentation to The Commons & Lords Management Boards 26 th November 2008

How can we prevent security breaches?

OPEN PARK. Automatic Number Plate Recognition that works worldwide including Egypt Number plates

Transcription:

Testing of installations in road tunnels.

Agenda The Norra Länken-project Presentation of the magnitude of the tests FAT-site with different systems and objects Testing workflow of the Norra Länken-project What can we do be better as clients in our contracts 2 2013-09-24

3 2013-09-24 Norra Länken

Design requirements Norra Länken: Road twin tunnel approx.16 km roads including 11 km road tunnels with19 technical rooms and 50 escape routes The tunnel includes underground on and off access points The tunnel is divided in 22 traffic sections Continuous supervision from Traffic central Tunnel operation includes15 different systems; Electric, Fire, Roadsigns, Tunnelvent, Traffic, Control, Watersupply, SDS, Tele comm. DCS, Control system with approx. 6000 objects or 150.000 tag Dimensioned for queue Fixed Fire Fighting System Fire load: 100 MW Longitudinal tunnel ventilation with jet fans Air supply- and exhaust-stations Very high environmental requirements for tunnel ventilation Traffic flow 100,000 vehicles/day 20% of heavy load vehicles No separate smoke shaft None purification of the air 4 2013-09-24

Contracts installation NL 66 NL 67 NL 68 NL 69 NL72 Electrical systems, control systems, telecommunication systems and traffic systems. Contractor Tunnelentreprenad Jet-Fans for tunnel ventilation. Contractor Bravida Ventilation and electr. installation in substations. Contractor Bravida Waste water and pumps. Contractor Läkeby Water Fixed Fire Fighting System. Contractor Bravida All-in contract / Functional specification 5 2013-09-24

Working process and payment Design. Specifications, Plans, Documentation. Manufacturing Installation Testing (FAT); Component, Own contract, All contracts (NL66-NL67/68/69) Commissioning (SAT); Installation, Function, Continuity check Pilot operation (OAT) Achievement based payment plan Opens for public in nov 2014 6 2013-09-24

NL66 El-, Telecom-, Control-and traffic systems Electrical systems Telecom. Systems Traffic system Control system Other Power supply ink UPS, Tunnel lightning with carriageway lightning. Telephony, Radio, CC-TV, Security, Fire alarm etc. Motorway control, Variable signs, Barriers, Accident and incident detection. Control and monitoring of all technical systems. Interfacing central system in traffic management centre Trafik Stockholm, Doors and hatches, operation and dismantling of temporary installation. Contract Includes: Temporary operation before opening Maintenance 5 years (year 3 to 5 optional) Coordinator for working environment 7 2013-09-24

TALK / DATA TALK RS CS TR RD TD CD d i g i t a l Why is it so complex? Stop Detection of vehicles, an example of communication and functions (LLU/ LLC) Citect I/O Ritn.: XXXYZZZ Citect Alarm SD S - Fu n k t i o n Funktion Internt kablage Profibus - DP Ethernet (GCP) Kamerasignal (Fiber) Beskrivning av funktionssamband mellan olika Teknikområden med kommunikationsgränssnitt åskådliggjorda. Preliminär Dokumenteras av TO.. Global Communication Platform Citect EG TO- Trafik (DU) Ritn.: XXXT4310 Portserver TO-Tele (DU) Ritn.: XXXYZZZ TO- Styr (DU) Ritn.: XXXYZZZ S7- PCMS Internt kabl. S/V Videosignal Traffic Box Video Trak ITV TO-Kraft (DU) Ritn.: XXXYZZZ C UPS Kamera 8 2013-09-24

Factory Acceptans Testing A metod to ensure technical type solutions for client and contractors for turnkey contracts. The importance to understand the written words 9 2013-09-24

My first experiense was at Harman & Braun in Minden. Testing area at Prufeldt for Hässelby Power plant (200MW Electric) in 1992 Testing of on/off objeks Process pictures Start and stop seqences for boiler and turbine Today working with functional demands and testing for the road tunnels and bridges in the Stockholm area for Trafikverket since 2002 Testing of on/off objects Process pictures Start and stop sequences for tunneloperation and road bridges 10 2013-09-24

FAT (Factory Acceptance Test) FAT refers acceptance testing during factory testing, ie, before delivery to and installation in the plant. FAT 1 Factory Testing of standard components and equipments. ** FAT 2 Functional testing of composite components / functional units whose function has adapted and developed according to the project needs, integration tests for the control and monitoring functions for each system. ** FAT 3 Sample of features and functionality related to two operations areas, incl. integration tests with other systems and system tests and performance test. Testing includes verification of signal exchange with systems or components delivered in another contract. ** FAT 4 Tests of the plant's entire functionality incl. verification of operation against Trafik Stockholm (the regional traffic central) real time systems. *** ** The customer and contractor takes part *** Lead by the customer and the contractor takes part 11 2013-09-24

SAT (Site Acceptance Test) SAT refers to testing at the plant site. SAT 1 test of all functions in all technological systems within their operations area. * SAT 2 test of all system functions and functional connection between systems within all operating areas. The test also includes testing of interfaces to systems or components supplied by other contractors. ** SAT 3 Testing the system on plant-wide level incl. performance tests and tests of sequenses for tunnel closing and opening. ** SAT 4 Overall test of the entire plant functionality incl. integration test against the Trafik Stockholm real time systems and verification of the system's functions at predefined event scenarios. *** * The contractor takes part ** The customer and contractor takes part *** Lead by the customer and the contractor takes part 12 2013-09-24

OAT (Operational Acceptance Test) OAT relates trial operation. OAT 1 Before the traffic opening; Trial operation of the installation and operation of the regional systems in Trafik Stockholm. Commissioning and operator training beforetraffic opening. *** OAT 2 after traffic opening; Trial operation of the installation and operation of the regional systems in Trafik Stockholm. Commissioning and operator training for Traffic opening. *** GAT (Guarantee Acceptance Test) GAT intends guarantee test. GAT 1 Follow-up during the warranty period with samples *** *** Lead by the customer and the contractor takes part 13 2013-09-24

The Contractor shall provide a suitable test site for the test facility. The venue will be in Stockholmsregionen. FAT 3 and 4 shall be implemented in a contractor prepared test facility. The test facility shall include at least one item of each type but if several items are necessary to achieve the intended function of the number of items included. Each Contractor shall submit to the test facility, provision of equipment to test the interoperability of equipment delivered in other contracts. 14 2013-09-24

The test facility shall include; Control and monitoring systems for redundant operation areas 1 and 2 and control and monitoring systems for a substation. Equipment in local management center, such as microphone, Fire tableau. All types of central equipment, traffic and telecommunications equipment, and monitors Sensor for control and monitoring in general All types main components such as switchgear, cameras etc included in a substation which shall be controlled and monitored. Control and monitoring systems for the various types of facilities that are provided by sub-contractors. Equipment for the overall test of the entire plant functionality incl integration test against the Trafik Stockholm real time systems and verification of the system's function which also are supplied by the Customer 15 2013-09-24

FAT-workflow The contract includes approximately 3000 claims. Functions and performance requirements The contractor NL66 do the following: Start the planning of the plant parallel to the FAT 1-4 works Establishes System description for all technical systems Establishes System specification for all technical systems with more details, manufacturer, model, performance, etc. Creates Graphical Function Block in the DCS -system* approx. 50-60. Image Building and server configuration (redundancy, load distribution etc. Programming and self-control of function blocks (which is then reused for all hardware controllers) * DCS = Distributed Control System 16 2013-09-24

FAT-workflow cont. Establishes Test Documents, certificates and schedules Establishes control specification with claims and step by step implementation for testing Testing of all type object and systems For example in FAT-3; Action Plans, barriers and shutdown device, lane signals, moving camera, the closing and opening of the tunnel Desktop connectivity for reviewing images All events are stored in web-based log and rated Number of events: FAT 2: no: 157 and FAT-3: no: 190 Major changes after FAT is handled via CCB *and require retesting CCB = Change Control Board 17 2013-09-24

18 2013-09-24 FAT-utr.pdf

Improvements and simplifications One contract for engineering systems Tender document in a turnkey contract, shall consist of thought functional requirements Each technical system with requirements may only consist of 10-15 pages Simple Solutions Standardized solutions Uniformly labeling system Combine FAT-testing with the installed equipment in a early made supply station with switchgear, transformers, telecomm. cabinet control cabinet Use a simulator for tunnel ventilation to get a faster commissioning (Stockholm Bypass) Work with the contractor under the legal and contractual requirements that prevail Make demands on the skills of personnel for similar tunnel projects Make demands on a common control and monitoring technical system with support organization within the region 19 2013-09-24

20 2013-09-24 Demolishing testing (Not in our claims, just for fun)

The Stockholm bypass Length: just over 21 km Tunnel: just over 18 km Tunnel length: approx. 50 km Travel time: approximately 15 minutes No. of lanes: three in each direction Junctions: six Traffic 2035: 140,000 vehicles/day Build start: earliest 2013 Completion: 8-10 years Cost: SEK 27.6 billion EUR 3.1 billion (2009 prices) 21 2013-09-24

Thanks you for your attention. Lars Elertson Specialist control, monitoring and communication. lars.elertson@trafikverket.se Mobil: +46 70 587 67 34 Swedish Transport Administration 22 2013-09-24