Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet



Similar documents
Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

Agilent E5063A ENA Series Network Analyzer

Make Better RMS Measurements with Your DMM

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Agilent 4339B/4349B High Resistance Meters

Variable Frequency Drive Troubleshooting with U1610A/U1620A

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Agilent 87421A/87422A Power Supply

Agilent FieldFox Remote Viewer

Agilent 4338B Milliohm Meter

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

802.11ac Power Measurement and Timing Analysis

Agilent U2000 Series USB Power Sensors

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Agilent U2000 Series USB Power Sensors

Keysight N9320B RF Spectrum Analyzer

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

DDR Memory Overview, Development Cycle, and Challenges

The Next Generation in Automated Oscilloscope Test

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

DC Electronic Loads 8500 series

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Multi-Range Programmable DC Power Supplies 9115 Series

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.

Fluke 3000 FC Series Test Tools Technical Data

2000 6½-Digit Multimeter

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance

U1602A Handheld Oscilloscopes, 20 MHz

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Agilent 8762/3/4A,B,C Coaxial Switches

Keysight Technologies AC6800 Series Basic AC Power Sources. Data Sheet

Agilent VEE Pro Data Sheet

Mobile Communications DC Sources W

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Voltech DC1000. Precision DC Bias Current Source

Multi-Range Programmable DC Power Supplies 9115 Series

Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note

Evaluating Oscilloscope Bandwidths for Your Application

1.44 kw Programmable DC Power Supplies XLN Series

High Power Programmable DC Power Supplies PVS Series

1.5 GHz Active Probe TAP1500 Datasheet

10 Multimeter. Users Manual

Agilent P940xA/C Solid State PIN Diode Switches

Agilent U2000 Series USB Power Sensors

N6171A MATLAB Data Analysis Software for Agilent Instruments

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

Fluke 3000 FC Series Test Tools Technical Data

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

PXI and AXIe Modular Instrumentation

Agilent 34405A 5 ½ Digit Multimeter

Physical Specifications (Custom design available.)

Agilent U4301A PCI Express 3.0 Analyzer Module. Data Sheet. Agilent solutions for PCIe Gen1 to Gen3 analysis and emulation.

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

Real-Time Spectrum Analysis for Troubleshooting n/ac WLAN Devices

PXI and AXIe Modular Instrumentation

Agilent E6832A W-CDMA Calibration Application

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

AutoRanging Digital MultiMeter

E5061B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet

Agilent Television Power Consumption Testing. Application Note

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

TekSmartLab TBX3000A, TSL3000B Datasheet

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

PCI Express 1.0 (2.5 GT/s) Protocol Test

Agilent Automotive Power Window Regulator Testing. Application Note

Keysight N6854A Geolocation System. Configuration Guide

PICOTEST. M3500A 6.5 Digit Digital Multimeter. User s Manual

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Agilent U2000 Series USB Power Sensors

Digital Clamp-on DMMs with uncompromising performance

DCS Series 1 kw, 1.2 kw, & 3 kw

Agilent Network Monitoring Content Intercept Manager

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Agilent E5100A Network Analyzer

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

User's Guide. True RMS Industrial Multimeter

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

High Voltage Power Supplies

Keysight E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software

Agilent E3633A and E3634A DC Power Supplies

Dual Display Digital Multimeter

Agilent M9018A. Challenge the Boundaries of Test Agilent Modular Products. Data Sheet. PXIe Chassis 18-slots, 3U, 8GB/s

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

Agilent GPIB, USB and Instrument Control Products

Think SAFETY When Selecting a Handheld Multimeter

Transcription:

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Data Sheet

Features 120000 counts resolution 16 built-in measurement functions including temperature and capacitance 0.025% 1-year DC voltage accuracy USB 2.0 SCPI compatible Agilent IO Library Suite and DMM Intuilink connectivity software included Affordable and Feature Rich Measurement Tool With the 34405A digital multimeter, you get all the tools you need at an affordable price without compromising the quality Agilent products are known for. It provides a broad range of features and measurement functions such as DC voltage, DC current, true- RMS AC voltage and AC current, 2-wire resistance, frequency, diode test and continuity which are designed to meet general industrial needs. Furthermore, it can measure temperature ranging from -80 o C to 150 o C. The true value is more evident with its capability to measure capacitance ranging from 1000 pf to 10000 µf. Agilent 34405A also improves efficiency and accuracy with its six built-in math operations: Null, dbm, db, MinMax, Limit and Hold. Quick Connection to the PC with USB 2.0 Interface For those with a need to control and take preset measurements with a PC, the built-in USB 2.0 interface provides an easy and robust connection between the PC and DMM. The USB interface connects directly to the PC host and works seamlessly with Agilent Connectivity software and can be controlled remotely via industry standard SCPI commands or through DMM Intuilink Connectivity software. IVI-COM and LabVIEW drivers are included to ensure an easy integration with different programming environments. Bright Display, Fast Reading Speed and Configuration Storage When high throughput and productivity are the priority, Agilent 34405A VFD dual display feature allows users to take more than one measurement and display them simultaneously on the front panel. For speed critical applications, Agilent 34405A can take up to 19 readings/sec at 4.5 digits resolution directly to the PC. In addition, the user can configure and store complete instrument setups and recall them at anytime from any of the four built-in storing states. Rugged and Reliable The 34405A is designed and tested according to major Safety and Regulatory Standards. In addition, the shock absorbing bumpers is designed to prevent physical damage from your day-to-day use. You can watch 34405A in action on your PC by downloading the interactive demo from the 34405A homepage at www.agilent.com/find/34405a Go to the WEB for more information on Agilent s DMM. Visit www.agilent.com 2

DC CHARACTERISTICS [1] ACCURACY ± (% of reading + % of range) Temperature Cefficient FUNCTION RANGE [2] BURDEN VOLTAGE IMPEDANCE [3] 23 C ± 5 C 28 C - 55 C TEST CURRENT OR INPUT 1 Year 0 C - 18 C VOLTAGE 100.000 mv - 10.0 MΩ ±2% 0.025+0.008 0.0015+0.0005 1.00000 V - 10.0 MΩ ±2% 0.025+0.006 0.0010+0.0005 10.0000 V - 10.1 MΩ ±2% 0.025+0.005 0.0020+0.0005 100.000 V - 10.1 MΩ ±2% 0.025+0.005 0.0020+0.0005 1000.00 V - 10.0 MΩ ±2% 0.025+0.005 0.0015+0.0005 RESISTANCE 100.000 Ω 1.0 ma - 0.05+0.008 [3] 0.0060+0.0008 1.00000 kω 0.83 ma - 0.05+0.005 [3] 0.0060+0.0005 10.0000 kω 100 μa - 0.05+0.006 [3] 0.0060+0.0005 100.000 kω 10.0 μa - 0.05+0.007 0.0060+0.0005 1.00000 MΩ 900 na - 0.06+0.007 0.0060+0.0005 10.0000 MΩ 205 na - 0.25+0.005 0.0250+0.0005 100.000 MΩ 205 na 10 MΩ - 2.00+0.005 0.3000+0.0005 CURRENT 10.0000 ma < 0.2 V - 0.05+0.015 0.0055+0.0005 100.000 ma < 0.2 V - 0.05+0.005 0.0055+0.0005 1.00000 A < 0.5 V - 0.20+0.007 0.0100+0.0005 10.0000 A < 0.6 V - 0.25+0.007 0.0150+0.0005 CONTINUITY 1000 Ω 0.83 ma - 0.05+0.005 0.0050+0.0005 DIODE TEST [4] 1.0000 V 0.83 ma - 0.05+0.005 0.0050+0.0005 AC CHARACTERISTICS [1] ACCURACY ± (% of reading + % of range) Temperature Cefficient FUNCTION RANGE [5] FREQUENCY 1 Year 23 C ± 5 C 0 C - 18 C 28 C - 55 C TRUE-RMS AC 100.000 mv 20 Hz - 45 Hz 1.0+0.1 0.02+0.02 VOLTAGE [6] 45 Hz - 10 khz 0.2+0.1 0.02+0.02 10 khz - 30 khz 1.5+0.3 0.05+0.02 30 khz - 100 khz [7] 5.0+0.3 0.10+0.02 1.00000 V to 750.00 V 20 Hz - 45 Hz 1.0+0.1 [14] 0.02+0.02 45 Hz - 10 khz 0.2+0.1 0.02+0.02 10 khz - 30 khz 1.0+0.1 0.05+0.02 30 khz - 100 khz [7] 3.0+0.2 [15] 0.10+0.02 TRUE-RMS 10.0000 ma to 10.0000 A 20 Hz - 45 Hz 1.5+0.1 0.02+0.02 AC CURRENT [8] 45 Hz - 1 khz 0.5+0.1 0.02+0.02 1 khz - 10 khz [9] 2.0+0.2 0.02+0.02 3

AC CHARACTERISTICS [1] ACCURACY ± (% of reading + % of range) FUNCTION RANGE [5] FREQUENCY 1 Year 23 C ± 5 C Temperature Cefficient 0 C - 18 C 28 C - 55 C FREQUENCY [10],[16] 100.000 mv to 750.00 V < 2 Hz [17] 0.18+0.003 0.005 < 20 Hz 0.04+0.003 0.005 20 Hz - 100 khz [11] 0.02+0.003 0.005 100 khz ~ 300 khz [12] 0.02+0.003 0.005 10.0000 ma to 10.0000 A < 2 Hz [17] 0.18+0.003 0.005 < 20 Hz 0.04+0.003 0.005 20 Hz ~ 10 khz [11] 0.02+0.003 0.005 TEMPERATURE and CAPACITANCE CHARACTERISTICS [1] ACCURACY ± (% of reading + % of range) FUNCTION RANGE TEST CURRENT, etc. 1 Year 23 C ± 5 C Temperature Cefficient 0 C - 18 C 28 C - 55 C TEMPERATURE -80 C - 150 C 5 kω thermistor probe Probe accuracy + 0.2 C 0.002 C -110.0 F - 300.0 F 5 kω thermistor probe Probe accuracy + 0.4 F 0.0036 F CAPACITANCE 1.000 nf 0.75 μa 2.0+0.8 0.02+0.001 10.00 nf 0.75 μa 1.0+0.5 0.02+0.001 100.0 nf 8.3 μa 1.0+0.5 0.02+0.001 1.000 μf - 100.0 μf 83 μa 1.0+0.5 0.02+0.001 1000 μf 0.83 ma 1.0+0.5 0.02+0.001 10 000 μf 0.83 ma 2.0+0.5 0.02+0.001 [1] Specifications are for 30 minutes warm-up, 5 1/2 digit resolution and calibration temperature 18 C - 28 C. [2] 20% over range on all ranges except 1000 Vdc. [3] Specifications are 2-wire ohms using Math Null. If without Math Null, add 0.2 Ω additional error. [4] Specifications are for the voltage measured at the input terminals only. [5] 20% over range on all range except 750 Vac [6] Specifications are for sinewave inputs >5% of range. Maximum crest factor : 3 at full scale. [7] Additional error to be added as frequency >30 khz and signal input <10% of range. 30 khz ~ 100 khz: 0.003% of full scale per khz. [8] For 12 A terminal, 10 A dc or ac rms continuous, >10 A dc or ac rms for 30 seconds ON and 30 seconds OFF. [9] For 1 A and 10 A ranges, the frequency is verified for less than 5 khz. [10] Specifications are for half-hour warm-up, using 0.1 second aperture. The frequency can be measured up 1 MHz as 0.5 V signal to 100 mv/1 V ranges. [11] For 20 Hz ~ 10 khz, the sensitivity is AC input current from 10% to 120% of range except where noted. [12] For 100 khz ~ 300 khz, the sensitivity will be 12% ~ 120% of range except 750 V range. [13] Input Impedence is in paralleled with capacitance <120 pf. [14] For input <200 V rms [15] For input <300 V rms [16] For frequency, use AC Accuracy ± (% of reading + 3 counts) [17] Minimum measured frequency is 1 Hz 4

OPERATING CHARACTERISTICS Auto Range (sec) [4] Function Digits Reading Function Change Range Change Reading Speed Over Speed [1] (sec) [2] (sec) [3] USB/(sec) [5] DCV 5.5 15 /s 0.3 0.3 < 1.2 8 4.5 70 /s 0.2 0.2 < 1.1 19 DCI 5.5 15 /s 0.4 0.4 <1.0 8 4.5 70 /s 0.3 0.3 < 0.5 19 ACV 5.5 2.5 /s 1.3 1.7 < 5.7 2 4.5 2.5 /s 1.2 1.5 < 5.1 2 ACI 5.5 2.5 /s 1.8 2.2 < 4.7 2 4.5 2.5 /s 1.5 1.9 < 4.0 2 FREQ [6] 5.5 9 /s 2.8 2.8 < 5.8 1 4.5 9 /s 2.5 2.5 < 5.0 1 [1] Reading rate of the A/D converter. [2] Time to change from 2-wire resistance to this specified function and to take at least one reading using SCPI FUNC and READ? commands. [3] Time to change from one range to the next higher range and to take at least one reading using SCPI FUNC and READ? commands. [4] Time to automatically change one range and to take at least one reading using SCPI CONF AUTO and READ? commands. [5] Number of measurements per second that can be read through USB using SCPI READ? command. [6] Reading rate depends on signal frequency >10 Hz. DIMENSIONS 5

SUPPLEMENTAL MEASUREMENT CHARACTERISTICS DC VOLTAGE Measuring Method: Sigma Delta A-to-D converter Input Resistance: 10 MΩ ± 2% range (typical) 1000 V on all ranges RESISTANCE Measuring Method: 2-wire Ohms Open-circuit voltage: Limited to < 2.8 V 1000 V on all ranges DC CURRENT Shunt Resistance: 0.1 Ω to 10 Ω for 10 ma to 1.2 A ranges 0.01 Ω for 12 A range Front Panel 1.25 A, 500 V fuse for I terminal Internal 15 A, 600 V fuse for 12 A terminal CONTINUITY/DIODE TEST Measuring Method: Uses 0.83 ma ± 0.2% constant current source, < 5 V open circuit voltage Response Time: 70 samples/second with audible tone Continuity Threshold: 10 Ω fixed 1000 V TEMPERATURE Measurement Method: 2-wire Ohms measurement of 5 kω thermistor sensor (E2308A) with computer conversion Auto-ranging measurement, no manual range selection 1000 V MEASUREMENT NOISE REJECTION CMRR (Common Mode Rejection) for 1 kω unbalance LO lead DC 120 db AC 70 db NMR (Normal Mode Rejection) For 60 Hz (50 Hz) ± 0.1% 5 1/2 digit 65 db (55 db) 4 1/2 digit 0 db AC VOLTAGE Measurement Method: AC coupled true-rms - measure the ac component with up to 400 Vdc bias any range Crest Factor: Maximum 5:1 at full scale Input Impedance: 1 MΩ ± 2% in parallel with < 100 pf of all ranges 750 Vrms on all ranges AC CURRENT Measuring Method: DC coupled to the fuse and current shunt, AC coupled true-rms measurement (measure the AC component only) Shunt Resistance: 0.1 Ω to 10 Ω for 10 ma to 1.2 A range 0.1 Ω for 12 A range Externally accessible 1.25 A, 500 V fuse for I terminal Internally replaceable 15 A, 600 V fuse for 12 A terminal FREQUENCY Measurement Method: Reciprocal counting technique. AC coupled input using AC voltage function. Signal Level: 10% of range to full scale input on all ranges Auto or manual range selection Gate Time: 0.1 second or 1 period of the input signal, whichever is longer. 750 Vrms on all ranges MATH FUNCTIONS Null, dbm, db, Min/Max/Avg, Hold, Limit Test TRIGGER and MEMORY Single trigger, 1 reading memory REMOTE INTERFACE USB 2.0 full speed, USBTMC-USB488 device class PROGRAMMING LANGUAGE SCPI, IEEE-488.1, IEEE-488.2 6

GENERAL CHARACTERISTICS POWER SUPPLY 100V/120V(127V)/220V(230V)/240V ± 10% AC line frequency 45Hz - 66Hz and (360Hz - 440Hz, 100/120V operation) POWER CONSUMPTION 16VA maximum, <11W average OPERATING ENVIRONMENT Full accuracy at 0 C to 55 C Full accuracy to 80% RH at 30 C (non-condensing) Altitute up to 3000 meters STORAGE COMPLIANCE - 40 C to 70 C SAFETY COMPLIANCE Certified to CSA for IEC/EN/CSA/UL 61010-1 2nd Edition MEASUREMENT CATEGORY CAT II, 300V: CAT I 1000Vdc, 750Vac rms, 2500Vpk transient over voltage Pollution degree 2 EMC COMPLIANCE Certified to IEC/EN 61326:2002, CISPR 11, and equivalents for Group 1, Class A SHOCK and VIBRATION Tested to IEC/EN 60086-2 SHOCK and VIBRATION Tested to IEC/EN 60086-2 DIMENSION (HxWxD) Rack: 88.5mm x 212.6mm x 272.3mm Bench: 103.8mm x 261.2mm x 303.2mm WEIGHT 3.75 kg, 8.27 lb WARM UP TIME 30 minutes WARRANTY One year for 34405A Three months for standard shipped accessories Standard shipped accessories: Agilent Optional Accessories Test lead kit Test report Power cord USB interface cable Quick Start Guide User s and Service Guide Product Reference CD-ROM Agilent IO Library Suite CD-ROM Options: Opt. 1CM - Rack mount adapter kit 34133A Precision Electronics Test Leads 34330A 30A Current Shunt E2308A Thermistor Probe 7

Agilent 34405A Multimeter: Versatile and low cost solution for benchtop testing. 5.5 digit dual display increases productivity and throughput in troubleshooting. Use the Up-Down keys to select the desired measurement range. Just press Shift -> Auto key to switch measurement range automatically. Superior value with a broad range of functions, which includes the temperature and capacitance measurements. Connect the supplied test leads to the Input Terminals to start your measurements. Selecting the secondary display measurements. Math functions and utility menu that allow users to take reference measurements (ie. Min/Max value and etc.) and store the measurement setups from the front panel. 8

www.agilent.com www.agilent.com/find/34405afind/34405a myagilent myagilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. www.pxisa.org PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Three-Year Warranty www.agilent.com/find/threeyearwarranty Agilent s combination of product reliability and three-year warranty coverage is another way we help you achieve your business goals: increased confidence in uptime, reduced cost of ownership and greater convenience. Agilent Advantage Services www.agilent.com/find/advantageservices Accurate measurements throughout the life of your instruments. Agilent Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System www.agilent.com/quality For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3600 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus (BP-3-1-13) Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2013 Published in USA, March 25, 2013 5989-4906EN