Digital input modules



Similar documents
TX OPEN RS232/485 module

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

PCS0100en Persy Control Services B.V. Netherlands

Air damper actuators

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Duct Humidity Transmitter

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

PHOENIX CONTACT Features

RRV934. Multi-controller. Synco living

VAV compact controller KNX / PL-Link

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Product and functional description

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

PXM20-E. Operator unit DESIGO PX

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

VAV compact controller KNX / PL-Link

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

OZW30. Central Unit SYNERGYR

48 SERIES Relay interface modules 10 A

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

CQM1-SF200/CS1W-SF200

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Electronic overload relay EF19 and EF45

CompactLogix Power Supplies Specifications

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

HMI display Installation Guide

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Inductive sensor NI10-M18-Y1X-H1141

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic overload relay EF65, EF96 and EF146

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

NX safety stand-alone

38 Series - Relay interface modules A

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Relés e Contatores de Estado Sólido SIRIUS

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

ZC-24DO CANopen I/O Module: 24 Digital Outputs

OZS Web server. For LPB/BSB plants

15 Series - Electronic step relay and dimmer. Features SERIE

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

49 Series - Relay interface modules A. Features

MINI MCR-SL-R-UI(-SP)

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

38 Series - Relay interface modules A

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Analog signal converters CC-E I/I Current / current isolators

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Quick Connect. quick - simple - efficient.

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Redundancy Module QUINT-DIODE/40

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RM4TG20 three-phase network control relay RM4-T - range V

IO-RM3 3-Stage Relay Module

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Flush-mount room temperature sensor AQR2531ANW.

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

E-STOP relays, safety gate monitors

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Preset Counter signo 721

AXIS T81B22 DC 30W Midspan

IFS SP-PoE Splitter User Manual

Safety technique. Emergency stop module BO 5988 safemaster

KNX Panasonic Air Conditioners

Liquid Level Limit Switch liquiphant T FTL 20

Transcription:

8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a green LED 8 or 16 digital inputs; individually configurable for status signals, status pulses (with a memory function) or counter pulses (up to 10 Hz) Compact DIN format, small footprint Separate terminal base and plug-in I/O module for convenient handling Self-establishing bus connection for maximum ease of installation Terminal isolation function for fast commissioning I/O module replaceable in seconds, without rewiring and without affecting the full functioning of the remaining I/O modules All terminals are directly on the I/O modules, allowing direct connection of field devices without additional terminal strips. Simple strategy for operation and display I/O status LED for each I/O point; mode of operation (N/C or N/O) depends on I/O function LEDs for fast diagnostics Double-sided labels for identification of all I/O points CM2N8172en_03 11 Jun 2010 Building Technologies

Functions The modules support the following I/O functions: Function Signal type Description Status indication D20 D20R Volt-free, interrogation (maintained contact), N/O contact Volt-free, interrogation (maintained contact), N/C contact Status pulses D20S Volt-free, N/O contact, interrogation (pulse) Counter pulses C Volt-free, N/O contact, interrogation (pulse, max. 10 Hz) (TXM1.16D: I/O points1... 8 only) For a detailed description of these functions, please refer to document CA110761, "TX-I/O Functions and operation". Compatibility Support of signal types and functions in different building automation and control systems: see TX-I/O Engineering and installation manual, CM110562 Type summary ASN Digital input module TXM1.8D Digital input module TXM1.16D Delivery The terminal base and the plug-in I/O module are interconnected and delivered in the same box. Accessories The available accessories include address keys, label sheets, and spare transparent label holders. Refer to data sheet CM2N8170. Technical and mechanical design For a description of the features common to all TX-I/O modules, please refer to the TX-I/O Engineering and installation manual, document CM110562. 2/8

Indicators and operator controls 18 20 22 24 26 28 30 32 Connection terminals (No. 1 screwdriver) with test pickup (for 1.8...2 mm pins) and terminal number 19 21 23 25 27 29 31 33 (9) (10) (11) (12) (13) (14) (15) (16) Signal designation 12 Address key and module status LED (2) (4) (6) (8) (10) (12) (14) (16) I/O point numbers (I/O points 9... 16: TXM1.16D only) (1) (2) (3) (4) (5) (6) (7) (8) 8172z10 2 4 6 8 10 12 14 16 1 3 5 7 9 11 13 15 I/O status LEDs (TXM1.8D: Configurable - green/yellow/red TXM1.16D: Green) I/O status LEDs The I/O status LEDs indicate the status of the inputs and outputs (peripheral devices) The LEDs on the TXM1.16D are green In the case of the TXM1.8D the LEDs are three-colored. If the I/O function supports it, the module can display Alarm = red and Service = yellow, besides Normal = green The LEDs are also used for diagnostic purposes Module status LED The module status LED illuminates the transparent address key The (green) LED shows the status of the module as a whole (as opposed to the status of the I/O points) It is also used for diagnostics Address key The module operates only with the address key inserted The module address is mechanically encoded in the address key When replacing the plug-in I/O module, the address key must be swiveled outward. It remains plugged into in the terminal base. 3/8

Module labeling The plug-in I/O module has a removable transparent cover (the label holder) for insertion of a label. 2 1 8172z11 Disposal The device is classified as waste electronic equipment in terms of the European Directive 2002/96/EC (WEEE) and should not be disposed of as unsorted municipal waste. The relevant national legal rules are to be adhered to. Regarding disposal, use the systems setup for collecting electronic waste. Observe all local and applicable laws. Engineering, mounting, installation and commissioning Please refer to the following documents Document TX-I/O Functions and operation TX-I/O Engineering and installation manual Replacement of legacy modules Number CM110561 CM110562 CM110563 Mounting Permitted orientation The TX-I/O devices can be installed in any orientation: It is important to provide adequate ventilation so that the admissible ambient temperature (max. 50 C) is not exceeded. 4/8

Technical data Supply (bus connector on side) Operating voltage DC 22.5... 26 V Extra low voltage SELV or PELV in accordance with HD384 Max. power consumption TXM1.8D 1.1 W TXM1.16D 1.4 W (for the sizing of power supplies, see CM110562) Protection All terminals of the modules Against shortcut and incorrect wiring with AC / DC 24 V Bus connector on side No protection! Field devices Insulation resistance The of the connected field devices against mains voltage must comply with the requirements for safety extra-low voltage (SELV) or protection by extra-low voltage (PELV) as per HD 384. Measuring cables Cable material Solid or stranded copper wire Cable cross section See manual CM110562 Permitted cable length max. 300 m Digital inputs / counter inputs *) Digital inputs are not electrically separated from the system electronics. Mechanical contacts must be volt-free Electronic switches must comply with SELV / PELV standards. Contact sensing voltage Contact sensing current Contact resistance with contacts closed Insulation resistance with contacts open DC 21.5...25 V 1.6 ma (initial current 10 ma) Max. 200Ω Min. 50kΩ Min. closing / opening time [ms] including bouncing Max. bounce time [ms] Max. Counting frequency (symmetric) Maintained contact 80 40 Pulse contact 50 30 Counter *) 40 30 10 Hz Counter memory *) 0... 4.3 x 10 9 (32 bit counter) *) Counting function for TXM1.16D: I/O points 1... 8 only Connection terminals Mechanical design Solid conductors Stranded conductors without connector sleeves Stranded conductors with connector sleeves (DIN 46228/1) Screwdriver Rising cage terminals 1 x 0.5 mm 2 to 4mm 2 or 2 x 0,6 mm to 1.5 mm 2 1 x 0.5 mm 2 to 2.5 mm 2 or 2 x 0,6 mm to 1.5 mm 2 1 x 0.25 mm 2 to 2.5 mm 2 or 2 x 0,6 mm to 1.5 mm 2 Slot-headed screws Screwdriver No. 1 with shaft diameter 4.5 mm 0.6 Nm Max. tightening torque Test pickups (terminals) For pin diameter 1 x 1.8 2.0 mm 5/8

Classification to EN 60730 Housing protection standard Ambient conditions Mode of operation of automatic electrical controls Contamination level Mechanical design Protection standard to EN 65029 Front-plate components in DIN cut-out Terminal base Operation Climatic conditions Temperature Humidity Mechanical conditions Operation Climatic conditions Temperature Humidity Mechanical conditions Type 1 2 Protection class III IP30 IP20 To IEC 60721-3-3 Class 3K5 5... 50 C 5 95 % rh Class 3M2 To IEC 60721-3-2 Class 2K3 25 70 C 5 95 % rh Class 2M2 Standards and directives Product standard Automatic electronic controls for household and similar use Electromagnetic compatibility Immunity (domestic & industrial) Emissions (domestic & industrial) CE conformity EMC Directive EN 60730-1 EN 60730-1 EN 60730-1 2004/108/EC C-tick conformity Emissions AS/NZS 61000-6-3 UL approbation UL 916, UL 864 Environmental compatibility The product environmental declaration CM1E8172 contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal) ISO 14001 (Environment) ISO 9001 (Quality) SN 36350 (Environmentally compatible products) 2002/95/EC (RoHS directive) Color Terminal base and plug-in I/O module RAL 7035 (light gray) Dimensions Housing to DIN 43 880, see "Dimensions" Weight Without / with packaging TXM1.8D 164 / 185 g TXM1.16D 199 / 220 g 6/8

Connection diagrams (examples) U U Digital input module (1) (2) (3) (4) (5) 1 2 3 4 5 6 7 8 9 10 K1 K2 K3 K4 S5 8172z13 K1 K2 K3 K4 S5 Status contact (N/O) Status contact (N/C) Pulse contact (N/O) Pulse contact (N/C) Electronic switch Terminal layout TXM1.8D, TXM1.16D TXM1.16D only I/O point (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) System neutral ( ) 1) 1 3 5 7 9 11 13 15 18 20 22 24 26 28 30 32 Input (+) 2 4 6 8 10 12 14 16 19 21 23 25 27 29 31 33 1) Terminals 1, 3, 5 etc. are system neutral terminals They are interconnected, not in the terminal base but in the plug-in I/O module. This means that when the I/O module is removed, there is no connection. The system neutral of a digital input can be connected to any system neutral terminal For wiring details refer to the TX-I/O Engineering and installation manual, CM110562. 7/8

Dimensions Dimensions in mm 90 67 45 22 44 70 77.5 7.1 98 108 64 3 8172M01 8/8 2007-2010 Siemens Switzerland Ltd Subject to change