MEGGER 210170 Insulation & Low Resistance Tester



Similar documents
User Guide. Model Insulation Tester / Megohmmeter

Model 1756 Test Lead Kit

Model UT201/202: OPERATING MANUAL. Table of Contents

User's Guide. True RMS Industrial Multimeter

Handheld portable appliance testers

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

Model UT33A: OPERATING MANUAL Table of Contents (1)

User Guide. 4 wire Earth Resistance Tester Model GRT300

AutoRanging Digital MultiMeter

PAT120, PAT150 and PAT150R Handheld portable appliance testers

7 FUNCTION DIGITAL MULTIMETER

Manual Ranging MultiMeter

HVAC Clamp Meter. Users Manual

UT202A Operating Manual. Contents

5000V Graphical Megohmmeter Model 5070

Test Before Touch Easier Said Than Done. Ken Crawford, DuPont Kent Haggerty, Dupont

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Table of Contents. Page

10 Multimeter. Users Manual

PowlVac Vacuum Integrity Tester

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

DET3 Contractor Series

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Owner s Manual & Safety Instructions

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Seven function digital multimeter

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

i410/i1010 AC/DC Current Clamp

Ground Resistance Clamp-On Tester

Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter

How To Use A Cdm250 Digital Multimeter

Instructions A Amp AC/DC Current Probe

MIT510/2, MIT520/2 and MIT1020/2

Essential Electrical Concepts

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Model UT58A/B/C: OPERATING MANUAL

A Practical Guide to Dielectric Testing

DET3 and 4 Contractor Series Earth/Ground Resistance Testers

Periodic Verification System Model 775PVS

TORKEL 820 Battery Load Unit

Ground Resistance Clamp On Tester

Load Cell Troubleshooting

Digital MULTIFUNCTION & INSULATION CONTINUITY-VOLTAGE TESTER

7 Watt Solar Charger Solar Panel

323/324/325. Calibration Manual. Clamp Meter

ADM1TE 5/30A DIN rail single phase two wire energy meter

12 Volt 30 Amp Digital Solar Charge Controller

User s Manual Before using the inverter, you need to read and save the safety instructions.

12-Volt 10-Amp Regulated Power Supply

Multifunction Process Calibrator

INTRODUCTION SAFETY PRECAUTIONS/

Insulation Resistance Testing of Low Voltage Cables in the Field

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Rutland 913 Windcharger Fault Finding Guide

IO-RM3 3-Stage Relay Module

Best Methods for Safe Hipot Testing

ATL Fuel Level Sender Probes

MIC-WKT and MIC-WKT-IR

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Wall-Mounting your HP computer. User Guide

DET3 Contractor Series 3-Terminal Earth/Ground Resistance Testers

Lab 3 - DC Circuits and Ohm s Law

LOW VOLTAGE TEST LEADS

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

RCD Inspection Log Book

ACL 395 Resistivity Meter

Specification. Li-ion Rechargeable Battery

Model 77 Series IV Digital Multimeter

Water Leak Detection System

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Owner s Manual & Safety Instructions

USER S MANUAL HSC-24A

Electrical Fundamentals Module 3: Parallel Circuits

Model PS-4001 Power Supply User Instructions

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

About this Manual. Support for Your Product

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

E-PDD Duct Smoke Detector Installation Sheet

Table of Contents. Page No.

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Benchtop Computer Monitor Generator

Solid-State Timer H3G

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

Understanding Insulation Resistance Testing

PAT400 Series. Portable Appliance Testers. User Manual

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Instructions For SF 6 Refill Kit

Battery Chargers. Revised 8/00 Form Number FORM NO / BATTERY CHARGER SERVICE MANUAL / PARTS LIST - 45

Transcription:

MEGGER 210170 Insulation & Low Resistance Tester User Guide SAFETY WARNINGS Safety Warnings and Precautions must be read and understood before the instrument is used. They must be observed during use. The circuit under test must be switched off, de - energized and isolated before Insulation or Continuity tests are made. Circuit connections must not be touched during a test. The test button must not be pressed while connecting the test leads or while changing ranges. The Test button must not be pressed when making a voltage test. The Default Voltmeter, and Automatic discharge are additional safety features and should not be regarded as a substitute for normal safe working practice. The 210170 is protected for connection to Power distribution systems up to 300 V Line - Ground, and 500 V Line - Line for Installation Category III*. It is recommended that fused test leads are used when measuring voltage on high energy systems. After insulation tests, capacitive circuits must be allowed to discharge before disconnecting the test leads. Test leads, prods and alligator clips must be in good order; clean, and with no broken or cracked insulation. Replacement fuses must be of the correct size, type and rating. NOTE THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSONS. Symbols used on the instrument Caution: risk of electric shock Caution: refer to accompanying notes Equipment protected throughout by Double Insulation (Class II)

MEASUREMENT SCALES OPERATION Refer to Safety Warnings before using the instrument Default Voltage measurement The 210170 will act as a default voltmeter (0 to 600 V a.c.) with any of the Insulation test positions selected. The Test push must not be pressed when making a voltage test. Note:- The 210170 is internally fuse protected to 500 V. For fuse protection with supplies above 500 V, use Fuse Probe Kit FPK5. 1. Select any Insulation test position with the rotary selector switch. 2. Carefully connect the test leads to the circuit under test. Do not press the Test push. 3. Read the voltage measurement from the voltmeter scale. 4. Carefully disconnect the test leads. Low Resistance measurement (Ω) 1. Select Ω with the rotary selector switch. 2. Ensure that all test leads are clean and in good condition, and connect them to the isolated circuit under test. 3. Any pointer deflection indicates a live circuit, and testing should be aborted. 4. Press the Test push, and keep it pressed while turning the generator handle. 5. Read the measurement from the kω scale. 6. Disconnect the test leads. Insulation Testing (MΩ) Automatic circuit discharge is effective when the test button is released, and decaying voltage is indicated by the scale needle until the circuit is discharged. 1. Select MΩ with the rotary selector switch. 2. Ensure that all test leads are clean and in good condition, and connect them to the isolated circuit under test. 3. Any pointer deflection indicates a live circuit, and testing should be aborted. 4. Press the Test button, and keep it pressed while turning the generator handle. 5. Read the measurement from the MΩ scale. 6. Release the Test push and monitor any scale needle movement to confirm when any discharging voltage decays to zero. 7. When the circuit has discharged, disconnect the test leads.

Using the Guard Terminal For basic insulation tests and where there is little possibility of surface leakage affecting the measurement, it is unnecessary to use the guard terminal. In cable testing, there may be surface leakage paths across the insulation between the bare cable and the external sheathing due to the presence of moisture or dirt. Where it is required to remove the effect of this leakage, particularly at high testing voltages, a bare wire may be bound tightly around the insulation and connected via the third test lead to the guard terminal G. Tightly bound bare wire Leakage path to - ve terminal The guard terminal is at the same potential as the negative terminal. Since the leakage resistance is effectively in parallel with the resistance to be measured, the use of the guard causes the current flowing through surface leakage to be diverted from the measuring circuit. The instrument therefore reads the leakage of the insulator, ignoring leakage across its surface. Measuring Ranges: Test Voltages (d.c.): Test V. Accuracy: ±5% Short Cct. Current: to G terminal SPECIFICATION Insulation Ranges 0-20,000 MΩ at all test voltages 100 V; 250 V; 500 V; 1kV on open circuit 220 µa nominal on all ranges Terminal Characteristics to + ve terminal Accuracy: Low resistance Range ±3% of scale length on a 3.08 inch arc length Measuring Range: 0-5000 Ω Open Cct. Voltage: 3 V ± 5% Short Cct. Current: 30 ma ± 10% Accuracy: ±3% of scale length on a 3.08 inch arc length Default Voltage measurement Range: Accuracy: General Specifications Overload rating: 0-600 V a.c. ±2.5% of scale length The 210170 is protected for connection to Power distribution systems up to 300 V Line - Ground, and 500 V Line - Line for Installation Category III*.

AVO INTERNATIONAL Archcliffe Road Dover Kent CT17 9EN Tel: +44 (0) 1304 502100 England Fax: +44 (0) 1304 207342 PO Box 9007 Valley Forge PA 19484-9007 Tel: +1 (610) 676-8500 U.S.A. Fax: +1 (610) 676-8610 4271 Bronze Way Dallas TX 75237-1017 U.S.A. Tel: +1 (800) 723-2861 (U.S.A. only) Tel: +1 (214) 330-3203 (International) Fax: +1 (214) 337-3038 MEGGER SARL 29 Allée de Villemomble, 93340 Le Raincy Paris Tel: +33 (1) 43.02.37.54 France Fax: +33 (1) 43.02.16.24 This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice. MEGGER is the registered Trade Mark of AVO INTERNATIONAL LIMITED. Copyright, AVO INTERNATIONAL LIMITED. Part No. 6172-382 - Edition 3 - Printed in England - 11GG

Temp. Range: Humidity: Operating: 14 F to 122 F Storage: 4 F to 158 F Operating: 70% RH at 68 F, 50% RH at 104 F Storage: 95% RH at 95 F Automatic Discharge: Capacitive circuits are automatically discharged when the Test push is released following an insulation test. Power Supply: Low voltage brushless a.c. generator Fuses: 2 x 500 ma (F) 500 V H.B.C. 10 ka min 1 1 4 x 1 4 To check these fuses, short all three test leads together and set the rotary selector switch on any Insulation test position. Press the Test push and keep it pressed while turning the generator handle. The needle should register approximately 2 MΩ. A zero reading indicates that the G fuse has ruptured. An Infinity reading indicates that the +ve fuse has ruptured. Guard fuse 0.5A(F) 500V HBC(10 ka) Positive fuse Fuse Replacement: Held in a screw type holder located in the base of the instrument. Use a flat blade screwdriver to release the center part of the holder, and remove the ruptured fuse. Replace with fuse(s) of the correct type, size and rating. Weight: 2.2 lb Dimensions: 8 1 4 (including generator handle) x 5 x 5 Cleaning: Wipe disconnected instrument with a clean cloth dampened with soapy water or Isopropyl Alcohol IPA) *Relates to transient overvoltage likely to be found in fixed installation wiring. Supplied ACCESSORIES Part Number User Guide 6172-382 Test lead set comprising:- 1 black, 1 red, 1 green test lead, with alligator clips 6220-436 Test Record Card (5 supplied) 210949 Optional Carrying case 217740 Fuses (500mA) x 5 6121-289 Fused probe kit FPK5 6111-288 Black test lead with large alligator clip 6220-295 Red test lead with large alligator clip 6220-586 Green test lead with large alligator clip 6220-587 Test Record cards (Pack of 20) 6111-216 Publication - A Stitch in Time AVTM21-P8B

REPAIR AND WARRANTY The instrument contains static sensitive devices, and care must be taken in handling the printed circuit board. If an instrument s protection has been impaired it should not be used, but sent for repair by suitably trained and qualified personnel. The protection is likely to be impaired if for example; it shows visible damage; fails to perform the intended measurements; has been subjected to prolonged storage under unfavourable conditions, or has been subjected to severe transport stresses. NEW INSTRUMENTS ARE GUARANTEED FOR 1 YEAR FROM THE DATE OF PURCHASE BY THE USER. Note: Any unauthorized prior repair or adjustment will automatically invalidate the Warranty. INSTRUMENT REPAIR AND SPARE PARTS For service requirements for MEGGER Instruments contact :- AVO INTERNATIONAL or AVO INTERNATIONAL Valley Forge Corporate Center Archcliffe Road 2621 Van Buren Avenue Dover Norristown, PA 19403 Kent, CT17 9EN U.S.A. England Tel: +1 (610) 676-8579 Tel: +44 (0) 1304 502243 Fax: +1 (610) 676-8625 Fax: +44 (0) 1304 207342 or an approved repair company. Approved Repair Companies. A number of independent instrument repair companies have been authorised for repair work on most MEGGER instruments, using genuine MEGGER spare parts. Consult the Appointed Distributor / Agent regarding spare parts, repair facilities, and advice on the best course of action to take. Returning an Instrument for Repair If returning an instrument to the manufacturer for repair, it should be sent freight pre-paid to the appropriate address. A copy of the invoice and of the packing note should be sent simultaneously by airmail to expedite clearance through Customs. A repair estimate showing freight return and other charges will be submitted to the sender, if required, before work on the instrument commences.