Fundamentals of Cut Resistance Testing

Similar documents
DuPont Kevlar The ScIence of cut PRoTecTIon

T 549. WORKING GROUP CHAIRMAN N/A; reaffirmed SUBJECT RELATED

EUROPEAN STANDARD EN 343:2003 PROTECTION AGAINST RAIN

UA741. General-purpose single operational amplifier. Features. Applications. Description. N DIP8 (plastic package)

OPERATING P L AYA B I L I T Y P R E C I S I O N D E S I G N

BZW50. Transil, transient voltage surge suppressor (TVS) Features. Description

Description of mechanical properties

Demystifying the European Machinery Directive and SEMI Requirements for the Industrial Automation and Semiconductor Markets

Peel Adhesion of Pressure Sensitive Tape

Fisher FIELDVUE Instrumentation Improving Safety Instrumented System Reliability

METHOD OF TEST FOR UNIT WEIGHT OF FRESH CONCRETE

P6KE. Transil, transient voltage surge suppressor (TVS) Features. Description. Complies with the following standards

Uninterruptible Power Supply Product Regulations and Standardization in the European Union. By Matteo Tricarico Patents and Regulatory Engineer

LM337. Three-terminal adjustable negative voltage regulators. Features. Description

AN2604 Application note

STTH1R04-Y. Automotive ultrafast recovery diode. Features. Description

ESDLIN1524BJ. Transil, transient voltage surge suppressor diode for ESD protection. Features. Description SOD323

ST High voltage fast-switching NPN power transistor. Features. Applications. Description

A Determination of g, the Acceleration Due to Gravity, from Newton's Laws of Motion

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

Table 1. Absolute maximum ratings (T amb = 25 C) Symbol Parameter Value Unit. ISO C = 330 pf, R = 330 Ω : Contact discharge Air discharge

EUROPEAN STANDARDS AND MARKINGS FOR HAND AND ARM PROTECTION

ULN2001, ULN2002 ULN2003, ULN2004

BD241A BD241C. NPN power transistors. Features. Applications. Description. NPN transistors. Audio, general purpose switching and amplifier transistors

AN3353 Application note

M Series Manual Handwheel Gear Actuators for Fisher Butterfly Valves

furnishings flammability characteristics

1.1.2 Polypropylene The polypropylene must be a white opaque film, 1 2 mil thick. Biaxial orientation is preferred.

MC Low noise quad operational amplifier. Features. Description

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

Grammage of paper and paperboard (weight per unit area) (Revision of T 410 om-08) (underscores and strikeouts indicate changes from Draft 1)

For Required Non-U.S. Analyst and Conflicts Disclosures, please see page 8. Exhibit 1: Average 3mo/6mo/1yr returns following a federal election

DuPont Personal Protection TECHNICAL BULLETIN NUCLEAR RISKS

Description. Table 1. Device summary. Order code Temperature range Package Packaging Marking

Agilent Automotive Power Window Regulator Testing. Application Note

TSL Professional Services

Should Costing Version 1.1

STN3NF06L. N-channel 60 V, 0.07 Ω, 4 A, SOT-223 STripFET II Power MOSFET. Features. Application. Description

Black epoxy paste adhesive system

How to calibrate an RTD or Platinum Resistance Thermometer (PRT)

Description. Table 1. Device summary

EN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at ore.hu.

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

AN2866 Application note

EVL185W-LEDTV. 185 W power supply with PFC and standby supply for LED TV based on the L6564, L6599A and Viper27L. Features.

The University of Toledo Soil Mechanics Laboratory

HP 16/18-Port Cable Management Kit Installation Guide

TS555. Low-power single CMOS timer. Description. Features. The TS555 is a single CMOS timer with very low consumption:

TEST REPORT. Report No.: B Rendered to: CROFT, LLC. Magnolia, Mississippi. PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95

Impact testing ACTIVITY BRIEF

2STBN15D100. Low voltage NPN power Darlington transistor. Features. Application. Description

Traditional Drawing Tools

Scotchgard Multi-Layer Protective Film 1004

TEST REPORT. Rendered to: INTERNATIONAL WINDOW Hayward, California. PRODUCT TYPE: Aluminum Hopper SERIES/MODEL: 7222

HONING LATHE DUPLICATOR CUTTERS

MT90 Series MicroHardness Traverse Testing System

LM135-LM235-LM335. Precision temperature sensors. Features. Description

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

EN Export Manager Pulastic Sports Surfaces The Netherlands

COMMERCIAL ITEM DESCRIPTION RUBBER, SILICONE

Exchange Traded Funds. An Introductory Guide. For professional clients only

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Power up with brilliant solutions Complete solutions for photovoltaic modules. Photovoltaic

Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems

The Basic Principles of Sieve Analysis

STATIC COEFFICIENT OF FRICTION MEASUREMENT USING TRIBOMETER. Static COF Time(min) Prepared by Duanjie Li, PhD

Sewing and Textiles. Basic Supplies: Advanced Project Supplies: Needed: Optional:

HIGH VISIBILITY CLOTHING FOR HEAVY & HIGHWAY CONSTRUCTION

BD238. Low voltage PNP power transistor. Features. Applications. Description. Low saturation voltage PNP transistor

PESDxU1UT series. 1. Product profile. Ultra low capacitance ESD protection diode in SOT23 package. 1.1 General description. 1.

STTH2R06. High efficiency ultrafast diode. Features. Description

HP Enterprise/ Mid-Market Desktop PC Power Supply Architecture

By the Citrix Publications Department. Citrix Systems, Inc.

Paulo Santos Kim B. Wittchen. The price of energy performance certificates

M24LRxx/CR95HF application software installation guide

TEST PROCEDURE FOR FIELD WITHDRAWAL RESISTANCE TESTING

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi

SAMPLE FORMAL LABORATORY REPORT. Fatigue Failure through Bending Experiment Adapted from a report submitted by Sarah Thomas

Global Structured Products

Trends in Machinery/ Automation Safety

2015 ST. JUDE MEDICAL THERAPY CODING GUIDE

BD135 - BD136 BD139 - BD140

APES 325 Risk Management for Firms

BASIC ACRYLIC MONOMER MANUFACTURERS, INC. CHEMICAL-PROTECTIVE GLOVES FOR ACRYLIC ACID AND ACRYLATE ESTERS SEPTEMBER 1999

Description. Table 1. Device summary. Order codes. TO-220 (single gauge) TO-220 (double gauge) D²PAK (tape and reel) TO-220FP

Developed By W. R. Freitas for METHACRYLATE PRODUCERS ASSOCIATION, INC. CHEMICAL-PROTECTIVE GLOVES FOR METHACRYLIC ACID AND ITS ESTERS

Use Advanced Analytics to Guide Your Business to Financial Success

T 815 SUBJECT. (No changes from Draft 2)

Choosing a Stencil. By William E. Coleman, Ph.D. and Michael R. Burgess

Optocoupler, Phototransistor Output, Dual Channel, SOIC-8 Package

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

Order code Temperature range Package Packaging

ULN2801A, ULN2802A, ULN2803A, ULN2804A

L6234. Three phase motor driver. Features. Description

Fire Protection Of Ventilation Systems DAMPERS & AIR TRANSFER GRILLES A PRESENTATION BY PHILLIP HORTON OF FIRE ENGINEERING SOLUTIONS

GreenGuard Housewrap Installation Guide

ORACLE PROCESS MANUFACTURING QUALITY MANAGEMENT

A revised guide to EN STANDARDS for gloves.

Transcription:

Fundamentals of 1 Introduction 2 ANSI/ISEA Classification 3 ANSI scale based on ASTM results 4 ISO Alternatives 5 Glossary 6 Conclusions

1 Introduction Fundamentals of As the market leader in hand protection, Ansell is significantly involved in developing and improving test standards related to cut resistance and is dedicated to delivering the best cut protection solutions to its customers. There are several standard test methods for measuring cut resistance that can be used to estimate the level of cut protection a glove should provide to a wearer. Depending on the geographic location and regulatory status of the product, the relative cut resistance performance of a glove is determined by one of two predominate level classification systems: ANSI/ISEA 105, which is used primarily in US markets, and EN388, which is used in Europe and other markets adhering to the CE certification process. The two systems use different methods for measuring cut resistance, and the following article will describe the similarities and differences between the two systems and provide insights into possible changes to testing and classification that could impact how users interpret cut protection in the future.

2 ANSI/ISEA Classification Under the ANSI/ISEA classification system as defined by ANSI/ISEA 105, American National Standard for Hand Protection Selection Criteria, the cut resistance performance level of a glove is determined by the results of ASTM F 1790, Standard Test Method for Measuring of Materials Used in Protective Clothing. The objective of ASTM F 1790 is to find the load required to cut through a material using a standardized blade after it has traversed a specified distance, known as the reference distance, across the material. Materials that can withstand higher loads at the same reference distance are interpreted as having higher cut resistance. Development and History of ASTM F 1790 ASTM F 1790 was first adopted in 1997 under the jurisdiction of subcommittee F23.20 on Physical Hazards and utilizes a testing device called the Cut Protection Performance Tester (CPPT) The standard was revised in 2005 (F 1790-05) in an attempt to harmonize with ISO 13997 by incorporating another testing device called the Tomodynamometer (TDM-100) and changing some aspects of the procedures. Due to issues with correlation and harmonization between the two devices and the previous version of the method, the standard was revised again in 2014 (F 1790-14) and reverted back to the 1997 version allowing for only the CPPT device to be used. A new ASTM method for the TDM was developed and approved in 2015 (See ISO Alternatives section for details on the TDM) Cut Protection Performance Tester

ASTM F 1790 Procedure Identify 3 loads that will cut the material within 2 in. (50.8 mm) of blade travel Make 5 cuts at each of the 3 loads using a new blade for every cut Using the 15 data points collected, plot the data after compensating for blade sharpness and perform a regression analysis to fit an exponential curve to the data (see Figure below) Calculate the cutting load (rating load) at the reference distance specified by method revision Method Revision Reference Distance (inches) Reference Distance (mm) F 1790-97 1 25 F 1790-05 0.8 20 F 1790-14 1 25.4* * In the original 1997 version of the method, the conversion between inches and millimeters was incorrectly rounded to the nearest millimeter even though the method requires recording the distance to the nearest 0.1 mm. This results in a different rating load estimate depending on which unit system was selected. The issue was corrected in the 2014 revision to the method by using the correct conversion of 1 inch = 25.4 mm, thus making the rating load calculation consistent between the two unit systems. Fundamentals of

Regression Analysis 60,0 Cut Through Distance, mm 50,0 40,0 30,0 25,4 20,0 10,0 0,0 0 100 200 300 362 400 500 600 700 Load, gf Figure. Regression procedure to determine the calculated cutting load of 362 gf at the reference distance of 25.4 mm (ASTM F 1790-14). Considerations when using the ASTM testing method: Variability of the test method can be high, particularly between different testing labs, as a result of inconsistencies with the blade supply, machine or operator errors, and the inherent variably of many highly cut-resistant materials that can contain multiple types of materials and constructions. The latest revision of F 1790 (2014) now provides calculations for variability including standard deviation and confidence intervals that can be used to gauge the variability of the test results and make comparison between multiple samples and testing locations easier. These same statistical features also appear in the standardize ISEA template for calculating the cut resistance level of the product. ANSI/ISEA 105 Level Classification Gloves are assigned a performance level based on the average rating force (now called the calculated cutting load) of three samples tested using either ASTM F 1790-07 or F 1790-05. The levels ranges are as follows: Level 0 < 200 1 200 2 500 3 1000 4 1500 5 3500 Rating Force (gf)

3 ANSI scale based on ASTM results EN 388, the European standard for protective gloves against mechanical risks, defines both the standard test method and the performance level classification for blade cut resistance. The primary test method for cut resistance in EN 388 differs from that used for ANSI/ISEA 105 and utilizes a device called the Couptest. The blade of the Couptest is circular and applies a counter-rotating motion under a fixed load of 5 N (equivalent to 510 gf). The blade is passed repeatedly over the sample, and the number of cycles to produce a cut through is determined. A cut index is calculated that determines the classification level of the product. EN 388 CUT Test Equipment Fundamentals of

Summary of the EN 388 Blade Cut Test The sample is clamped over a conductive rubber support A counter rotating circular blade slices back and forth on the sample under a constant force of 5 N (510 gf) A counter records the number cycles until the sample cuts, which is detected by an electrical circuit 5 cuts are performed on each sample, with 2 samples tested from each glove in alternate directions A cotton reference fabric is tested before each cut and is used to calculate the Cut Index and to normalize the data for the sharpness of the blade The Cut Index for the 5 cuts are averaged for each sample, and the lowest average Cut Index of the two samples is used to determine the performance Level of the product. The result is indicated in the second (b) position of the EN 388 pictogram. Sequence Cut Reference Fabric Cut Sample Cut Reference Fabric Calculate Cut Index Repeat sequence 5 times and average abcd Level Minimum Cut Index 1 1.2 2 2.5 3 5.0 4 10.0 5 20.0 Comparison of EN 388 and ASTM Cut Test Methods Blade Type EN (Couptest) Circular Double Beveled Blade Motion Counter-Rotating Slicing ASTM (CPPT) Straight Double Beveled Blade Reuse Blade used until dull New blade for each cut Blade Speed Variable, 0-110 mm/s Variable, 0-14 mm/s Force on Blade Constant, 500 gf (1 lbf, 5 N) Variable, 0-5000 gf (0-11 lbf, 0-50 N) Cuts per Sample 5 15 Cut Detection Method Electrical Contact Electrical Contact Measured Property Cycles to failure Distance of blade travel Test Result Calculated Cut Index (Unitless Ratio) Calculated Rating Force (grams-force or Newtons)

4 ISO Alternatives ISO 13997, International Standard for the determination of resistance to cutting by sharp objects, is an alternative standard test method for cut resistance utilizing a device called the Tododynamometer (TDM). The test devices and procedures for ISO 13997 and ASTM F 1790 are similar but involve some subtle changes that can affect the final test result. Both devices operate on the principle of applying varying loads to a straight-edged blade and recording the distance required to cut through the sample, and both procedures involve the calculation of a cutting load at a specified reference difference using a regression procedure. The reference distance is different for the two methods, however, and is specified as 20 mm in the ISO method and 1 inch (25-25.4 mm) in the ASTM method. Another important distinction between the two methods is the mounting procedure for the sample. In the ISO method, the sample is mounted on top of a conductive strip that when contacted by the blade signals the machine that a cut has occurred; in the ASTM method, the conductive layer is underneath the mounting tape used to secure the sample, which requires the blade to cut through both the sample and tape before a cut is detected. There are also mechanical differences between the TDM and CPPT, such as blade orientation, blade speed, the drive mechanism, and how the force is applied that can produce different results depending on the material being testing. Regression Analysis 60,0 Cut Through Distance, mm 50,0 40,0 30,0 20,0 10,0 0,0 0,0 1,0 2,0 3,0 4,0 4,3 5,0 6,0 7,0 Force, N Figure. Regression procedure to determine the calculated cutting force of 4.3 at the reference distance of 20 mm (ISO 13997). Fundamentals of

TDM Cut Test Machine Usage of ISO 13997 and the TDM in Product Classification ANSI/ISEA 105 Classification Even though the TDM device was incorporated into the 2005 revision of ASTM F 1790, the ASTM method was never recognized as a harmonized replacement for ISO 13997. The use of the TDM, however, is allowed by ANSI/ISEA 105 for use in determining cut resistance performance levels when tested under ASTM F 1790-05. It is expected that the TDM will also be accepted in future revisions to ANSI/ISEA 105 but under its new ASTM test method designation outside of F 1790. EN 388 Classification In the current revision of EN 388, ISO 13997 and the TDM will become the mandatory cut test for highly cut-resistant materials that have a dulling effect in the circular blade used in the coupe test. In this proposed revision to EN 388 projected to go into effect in 2016, ISO 13997 and the TDM will become a more important part of the EN cut protection classification system by providing a new letter-based designation for EN ISO cut resistance (level A to F) in addition to the current number-based blade cut resistance index from the Couptest. The new EN ISO cut designation will be mandatory for products that have a dulling effect on the blade during the Couptest (such as many products that contain glass) and voluntary for all other products. The new EN ISO cut level designation will appear in the fifth location (e) of the newly expanded pictogram and is proposed to be as follows: Performance Levels A B C D E F G H I abcd -p E EN ISO cut resistance (Newtons) 2 5 10 15 22 30 40 50 60

5 Glossary Organizations ANSI American National Standards Institute. A society of standardization societies which approves official American National Standards and which represents the USA in international standardization efforts. ASTM still officially American Society for and Materials, but they now recruit members from other countries and prefer to be known by just the initials. The largest single standards-writing body in the USA, a society which has over 130 technical committees covering a wide variety of topics. ASTM F23 is the Committee on Protective Clothing. CEN Comite Europeen de Normalization, European Committee for Standardization. The standards that they write are providing presumption of conformity to the PPE legislation and are therefore the principle standards for products sold in the European Community. ISEA International Safety Equipment Association. A society of manufacturers and other suppliers of safety equipment which writes ANSI-approved standards for these types of products. ISO International Organization for Standardization. Test Methods ANSI/ISEA 105 American National Standard for Hand Protection Selection Criteria. Current Revision, 2011 Under review for revision in 2015. EN 388 Protective Gloves Against Mechanical Risks. Current version, 2003 Under review for revision in 2015 ASTM F1790 Standard Test Method for Measuring of Materials Used in Protective Clothing. Current Revision, 2014. CPPT device only, with editorial revisions approved for 2015 Previous Revisions, 1997 and 2005 New method for the TDM approved for 2015 ISO 13997 Protective clothing Mechanical properties Determination of resistance to cutting by sharp objects. Current version,, 1999 Fundamentals of

Equipment CPPT Cut Protection Performance Tester, the device used in ASTM F1790. mcppt Modified Cut Protection Performance Tester, a modified version of the CPPT used for testing materials with high friction in ASTM F1790. TDM-100 Tomodynamometer, the device used in ISO 13997 and ASTM F1790-05. COUPTEST the device used in EN 388. General Terms From ASTM F1790-05, the property that hinders cut through (the penetration of the cutting edge entirely through material) when a material or a combination of materials is exposed to a sharp-edged device. Cut Protection - the combination of influences that tend to prevent a worker from being cut. Load a force placed on an object. In this context, the force placed on a blade to press it against a specimen of glove or protective clothing material. Rating Load (Cutting Load) From ASTM F1790, in cut resistance testing, the load required to cause a cutting edge to produce a cut through when it traverses the reference distance across the material being tested. For ASTM F1790-97 the distance is 1 inch (25 mm). For ASTM F1790-05 the distance is 0.8 inch (20 mm). For ASTM F1790-14 the distance is 1 inch (25.4 mm). In ISO 13997, this is called the Cutting Force and is calculated at a reference distance of 20 mm. Cut Index the value for cut resistance as calculated in EN 388. Repeatability the minimum difference required between sample means for two samples tested by the sample lab to be considered statistically different. Reproducibility - the minimum difference required between sample means for two samples tested by different labs to be considered statistically different.

6 Conclusions Fundamentals of The landscape of cut resistance testing is complicated and constantly changing. While great progress has been made over the last 20 years to standardize and harmonize the various approaches to testing cut resistance across the world, relying solely on the results of a laboratory test to predict cut protection is never enough. It takes experience and a true understanding of the end use application to deliver the right solution for your cut protection needs. Other factors such as environmental hazards, worker compliance, and cost all must considered when selecting the proper hand protection solution. Ansell, with its dedicated staff of trained sales professionals and advanced R&D resources, is constantly pushing the limits of technical innovation and customer focus to deliver the best cut protection solutions for your organization. & are trademarks owned by Ansell Limited or one of its affiliates, 2015 Ansell Limited. All Rights Reserved. Neither this document nor any other statement made herein by or on behalf of Ansell should be construed as a warranty of merchantability or that any Ansell product is fit for a particular purpose. Ansell assumes no responsibility for the suitability or adequacy of an end user s selection of gloves for a specific application. Europe Ansell Healthcare Europe NV Riverside Business Park Blvd International, 55 1070 Brussels, Belgium +32 2 528 74 00 +32 2 528 74 01 Hong Kong Ansell (Hong Kong) Limited Unit 3102-3103, 31/F Manhattan Place 23 Wang Tai Road Kowloon Bay, Hong Kong +852 2185 0600 +852 2856 2155 United States Ansell Protective Products Inc. 111 Wood Avenue South Suite 210 Iselin, NJ 08830, USA +1 800 800 0444 +1 800 800 0445 Latin America Ansell Brazil Ltda. Rua das Figueiras, 474 4º Andar Bairro Jardim SP 09080-300 Santo André Brazil CNPJ: 03.496.778/0001-21 +55 11 3356 3100 Australia Ansell Limited Level 3, 678 Victoria Street, Richmond, Vic, 3121 Australia +61 1800 337 041 +61 1800 803 578 Russia Анселл РУС 123610 Россия, Москва Краснопресненская Наб. 12, п.3, оф. 1304А Тел. +7 495 258 13 16