POWERS CONTROL RC 195 Single Input Receiver-Controller



Similar documents
RC 195 Multiple Input Receiver-Controller

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Model 43AP Pneumatic Controller, Style B

T-4000 Series Room Thermostat Adjusting Instructions*

General Information... 2

T and T Single Input Receiver-Controllers Installation and Calibration

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

T-4000 Series Pneumatic Room Thermostats

PNEUMATIC CONTROLS Selection and Description

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

POWERS Controls No. 4 Pneumatic Damper Actuator

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Part I - Installation

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Fisher 657 and 667 Diaphragm Actuators

Product/Technical Bulletin

Digital inductive conductivity transmitter

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

PIEZOMETER AIRFLOW MEASURING RING

Valve systems Base plates, according to standard ISO Brochure

Installation/ Operation Maintenance

IOM SERIES 820-E/P Electro-Pneumatic Positioner

Selection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume)

Many Products...One Source

Dissolved Oxygen Sensors

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Telefon (+45) Telefax (+45) Installation and operating manual

Control Box Wiring For PRSstandard Tool

Duct Humidity Transmitter

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Hinge Replacement & Hinge and Hardware Adjustment Guide for Andersen Frenchwood Hinged Patio Doors Manufactured Before November 2005

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

Toroidal Conductivity Sensor

Instruction Manual. A50099 Calibration Device. TIE-DEX CALIBRATION DEVICE A50099

WARNING CANADIAN D.O.C. WARNING

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Global Water Instrumentation, Inc.

SELECTION, APPLICATION AND MAINTENANCE

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Submersion/Insertion Toroidal Sensor

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

PTU Series Ultrahigh-Purity Pressure Transducers

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ACCUMULATOR INSTALLATION

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Speed-Mat Rectangle Cutter

STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER

Installation Instructions

WIKA INSTRUMENT CORPORATION

FX TYPHOON 12. Table of Contents

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Baumann Little Scotty Bronze Control Valve

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

TC-9102 Series Surface Mount Temperature Controllers

Rack Installation Instructions

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Model 201 Wiegand Touchpad Reader Installation Guide

PRESSURE REDUCING CONTROL VALVE

SELECTION, APPLICATION AND MAINTENANCE

Remote Alarm Monitoring System

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

INSTALLATION INSTRUCTIONS

A-4000 Oil Indicator

Pressure transmitter For general industrial applications Model A-10

SECUREPAK DIGITAL TORQUE TESTER

AMD-33 Air Measuring Station with VCD-33 Control Damper

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB EDITION 5.

Installation Instructions

GPS AutoSteer System Installation Manual

Reaction Torque Sensor

Combustible Gas Transmitter RK-05

PRODUCT PROFILE FEATURES

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09

Models SFP33 & SFP32 Pressure Transmitters

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Proportional pressure regulators VPPE

Machine Safety Switches

Solid-State Timer H3G

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Your safety and the safety of others are very important.

RAEGuard EC FGM-13XX

! WARNING. Before using product, read and understand instructions.

Transcription:

Document No. 155-119P25 RC 195-4 POWERS CONTROL RC 195 Single Input Receiver-Controller Description The RC 195 Single lnput Receiver-Controller is a pneumatic instrument which receives one pneumatic input, either direct acting (DA) or reverse acting (RA). It produces a pneumatic control signal based on the net pneumatic input and the mechanical settings of the setpoint and percent proportional band. Features Plug-in air connections make connecting, calibrating and servicing easy. lnternal restrictors provided for transmitter inputs. Application Stick-on scales for setpoint dial in standard transmitter ranges in both English and metric units. Large, easy-to-read scales on all adjustments. Tamper resistant cover. The RC 195 Single lnput Receiver-Controller is a one input (direct acting or reverse acting) instrument. lt is commonly used to control temperatures, humidity, and pressures of mechanical equipment in commercial buildings, such as offices, hospitals, universities, and schools. Product Number Single lnput Receiver-Controller 195-0011 with case and stick-on DA and RA scales (see Table 1).

RC 195 Single Input Receiver-Controller Table 1. Scale Ranges. English Scale Metric Identification 40 to 120 F A 40 to 50 C 50 to 100 F B 10 to 38 C 80 to 240 F C 26 to 117 C 20 to 80% rh D 18 to 38 C 0 to 100 F E 1 to 58 C 35 to 135 F F 0 to 750 Pa 0 to 3 lwg G 0 to 3.75 kpa 0 to 15 lwg H 20 to 80% rh 0 to 0.5 lwg J 0 to 125 Pa Blank 10 divisions K (DA) Blank 9 divisions Blank 16 divisions K (RA) Blank 11 divisions 0.05 to 0.20 lwg L 12.5 to 50 Pa 0.5 to 0.5 lwg M 125 to 125 Pa 0 to 10 lwg N 0 to 2.5 kpa Blank 20 divisions P Blank 15 divisions Specifications Operating Action: lnput #1 lnput #2 Pneumatic lnputs Control output Operating Ambient Temperature Range Supply pressure Operating Maximum safe Percent Proportional Band Adjustment Range Air Consumption Direct Action Reverse Action 3 to 15 psi (21 to 103 kpa) 0 psi (0 kpa) to supply pressure 40 to120 F (4 to 49 C) 22 psi (152 kpa) 30 psi (207 kpa) 2 to 20% for a 5 psi (34 kpa) control pressure change 60 scim (17 ml/s) Physical Mounting Surface Air Connections Barb fittings for 1/4-inch (6 mm) OD plastic tubing Two plug-in connectors are provided: one for the direct acting and the reverse acting transmitter inputs and one for supply and control lines. 1/8-inch NPT connection provided for control pressure gauge (gauge not included). Case material Lexan, 20% glass filled Dimensions See Figure 9 Weight 3.1 lb (1.4 Kg) Page 2

RC 195 Single Input Receiver-Controller Technical Instructions Accessories Operation Inputs Restrictor Kit 195-066 Connector Kit 195-114 RC 195 Pressure Simulator for two transmitters 195-099 Receiver-Controller Calibration Slide Rule 153-054 Scale Conversion Card (Form, single) 125-1661 Scale Conversion Card (Form, pkg. of 25) 144-022 The control pressure depends upon the position of the main lever which is determined by the sum of the forces acting upon it. On the left side of the pivot, two forces act against the lever: the bias spring and the #1 direct acting input pressure. On the right side of the pivot, three forces act against the lever: the control pressure acting through the percent proportional band slide, the #2 input pressure, and the setpoint spring. See Figure 1. Figure 1. Single lnput Receiver-Controller Schematic. When the net forces on each side of the pivot are equal, the lever is stationary and the control pressure is constant. A change in any of the forces moves the main lever to a new equilibrium position and provides a new control pressure. The input on the left side of the pivot is direct acting and the input on the right side of the pivot is reverse acting. An internal 40 scim (11 ml/s) restrictor is furnished for each input. Each restrictor must be switched "in" when an external restrictor is not used. When any input is not being used, its restrictor should be in the "out" position and the input connection should be open to the atmosphere. Restrictor "A" provides nozzle pressure and restrictor "B" minimizes hysteresis in the pilot relay as shown in Figure 1. Page 3

RC 195 Single Input Receiver-Controller Operation, Percent Proportional Band Installation General The pilot relay amplifies the nozzle pressure to provide the control pressure output. Control pressure goes to the controlled device(s) as well as the percent proportional band chamber to provide proportional feedback. For example, if the main lever is moved up on the left side of the pivot, the flapper will move toward the nozzle to increase control pressure. The increased pressure in the percent proportional band chamber will move the main lever up on the right side of the pivot moving the flapper away from the nozzle until an equilibrium and a new control pressure are reached. The amount of feedback is adjusted by moving the percent proportional band slide. NOTE: For additional information, see RC195 Single Input Receiver-Controller Installation Instructions (129-122). 1. Mount the RC 195 Single lnput Receiver-Controller in any position on any vertical surface using two #8 or #10 screws. The integral mounting tabs are located on the top and bottom of the case. NOTE: Small vibrations, such as those from an air handling unit will not affect the operation of the instrument. 2. Remove the cover by pulling to the right, lifting, then pulling to the left and lifting. Remove the cover for access to percent proportional band adjustment, the setpoint dial, and setpoint adjustment screw. 3. The setpoint dial comes with a 3-15 psi (21 to 103 kpa) scale. Place one of the stick-on scales (Table 1) on the dial to match the primary transmitter range. Each scale is marked DA or RA to match the required action of the receiver-controller. Figure 2. Single Input Receiver-Controller Connector, Restrictor, and Adjustment Locations. Page 4

RC 195 Single Input Receiver-Controller Technical Instructions Installation, 4. Check all the air connections particularly those to the transmitter to eliminate leaks. Even small leaks in the pneumatic lines to the transmitters will introduce large errors. 5. Check the supply pressure. The supply pressure must be a constant 22 psi (152 kpa). If it is different or if a dual air supply is used, error will be introduced into the transmitted signal. Figure 3. Typical Direct Action (DA) Installation. Figure 4. Typical Reverse Action (RA) Installation. Restrictors Restrictors are factory-installed in all inputs of the receiver-controller. Restrictors are in the "out" position as shipped from the factory. When an internal restrictor is required, the restrictor must be moved to the "in" position. Use the following procedures when dialing a new restrictor position: lf the transmitter input line is connected to "1", use restrictor "1". lf the transmitter input line is connected to "2", use restrictor "2". 1. Loosen both restrictor screws two full turns. 2. Move the restrictor tab back and forth between the full travel limits a minimum of two times or until there is no sensation of drag against the lever. This will allow the gasket to return to its proper position. 3. Retighten both screws with the restrictor lever fully in position against its stop. Do not over tighten the screws. Screws should be tight enough to provide a good seal without warping the restrictor assembly. NOTE: When an input is not being used, the restrictor should be in the "out" position and the input connection should be open to atmosphere. Figure 5 gives the maximum recommended distances for using the internal restrictor, external restrictor, and remote gauges. Note that 300 feet (91.5 m) is the maximum distance between air supply and the transmitter. lf the distance is more than 300 feet (91.5 m) between transmitter and receiver-controller, a remote air supply and external restrictor must be used. lf the maximum distances are exceeded, there will be excessive pressure drops and time delays which will produce faulty indication and unsatisfactory operation. Page 5

RC 195 Single Input Receiver-Controller Installation, Figure 5. Maximum Distances for External Restrictors and Remote Gauges. Generally, 1/4-inch (6.4 mm) OD plastic tubing should be used for all the connections to the plug-in air connectors. Larger size tubing will reduce the pressure drops, but it will increase time delays. Conversely, smaller tubing will reduce time delays but will increase pressure drops. Calibration Before making adjustments, several calculations are necessary. Steps 1, 2, and 3 must be completed before installation and the values noted on the control drawing. See Figure 6. Figure 6 shows how the values of percent proportional band and setpoint should be recorded. Figure 6. Control Drawing. Page 6

RC 195 Single Input Receiver-Controller Technical Instructions Calibration, Step 1 Determine Percent Proportional Band setting using Table 2 or Formula A. Transmitter Span F ( C) Table 2. Percent Proportional Band Settings. Percent Proportional Band Setting 5 psi (34 kpa) Spring Desired Throttling Range F ( C) 4 (2) 8 (4) 12 (7) 10 psi (69 kpa) Spring Desired Throttling Range F ( C) 4 (2) 8 (4) 12 (7) 50 (28) 8% 16% 4% 8% 12% 100 (56) 4% 8% 12% 2% 4% 6% 160 (89) 2.5% 5% 7% 2.5% 3.8% Formula A Desired Throttling % P.B. = Range ( F or C) X *5 psi or 34.5 kpa X 100 Controlling Spring Range Transmitter Span Final Controlled ( F or C) Device (psi or kpa) * This is the control pressure change for which the percent proportional band scale is designed. Example: 5 psi (34.5 kpa) spring range Desired throttling range 10 F (5.6 C) Transmitter span 100 F (56 C) Using Formula A: % P.B.= 10 F 100 F X 5 psi 5 psi X 100 %P.B. = 10% For metric: % P.B.= 5.6 C 56 C X 34.5 kpa 34.5 kpa X 100 %P.B. = 10% Step 2 Determine Setpoint Conditions. For most applications it is necessary to select one point called "Setpoint Conditions" in order to establish the value of all variables. For a single input receiver-controller, the setpoint condition equals the desired control point. This is expressed in percent relative humidity, degrees Fahrenheit, inches W.G., or metric units. Page 7

RC 195 Single Input Receiver-Controller Calibration, Step 3 Record data from Steps 1 and 2 on Control Schematic. 1. Set the proportional band pointer to value shown on control drawing. 2. Apply setpoint pressure to selected input (#1/DA or #2/RA) and with a screwdriver turn the setpoint adjustment screw until control pressure reaches 8 psi (55 kpa) or midpoint pressure of the spring range of actuator. 3. Calibrate the setpoint dial by pulling it up, turning it to agree with the transmitter input, and then releasing it. 4. Turn the setpoint adjustment screw until dial agrees with control drawing. NOTE: Whenever the proportional band is changed, the setpoint dial must be recalibrated. With the RC 195 Simulator the input can be adjusted to any value between 3 and 15 psi (21 and 103 kpa). In this way, the setpoint pressure can be checked to ensure that the receiver-controller is properly calibrated. Troubleshooting Before troubleshooting the operation of the RC 195 Single Input Receiver-Controller, ensure that: The supply pressure at the unit is 22 psi (152 kpa). The transmitter input being used is between 3 and 15 psi (21 to 103 kpa). Only one restrictor supplies the transmitter. The transmitter calibration is correct. Table 3. Troubleshooting Guide. Complaint Check Probable Cause Corrective Action Transmitter sensing medium None which is above (RA) or below Pressure increases (DA) the proportional band Rotate setpoint Receiver controller out of Recalibrate adjustment screw calibration counterclockwise Control pressure stays at approximately zero Control pressure stays at approximately supply pressure Rotate setpoint adjustment screw clockwise Pressure remains unchanged Pressure decreases Pressure remains unchanged Plugged pilot relay restrictors Receiver-Controller is defective Transmitter sensing medium which is above (DA) or below (RA) the proportional band Receiver-Controller out of calibration Receiver-Controller is defective Replace Pilot Relay Restrictors Replace Receiver Controller None Recalibrate Replace Receiver- Controller Page 8

RC 195 Single Input Receiver-Controller Technical Instructions Troubleshooting, Figure 7. Output Pressure/Transmitter Range Relationship In English Units. Figure 8. Output Pressure/Transmitter Range Relationship in Metric Units. Page 9

RC 195 Single Input Receiver-Controller Dimensions Figure 9. Dimensions. Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. POWERS CONTROL is a registered trademark of Other product or company names mentioned herein may be the trademarks of their respective owners. 2015 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 + 1 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com Document No. 155-119P25 Printed in the USA Page 10