EL-USB-4 4-20mA Current Loop USB Data Logger



Similar documents
EL-USB-1-LCD Temperature Data Logger with LCD


EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-500 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

Data Logging Solutions from Lascar Electronics

USER S GUIDE Humidity and Temperature USB Datalogger

Current Monitoring Kit

DataView DVTH Data Logger for Temperature and Humidity

Temperature Datalogger Users Manual

Current Monitoring Kit QUICK START GUIDE

SupcoLog Logger Interface Software

Data Loggers for Real Time Temperature Monitoring - WiFi

S P E C I F I C A T I O N F O R L I T H I U M B A T T E R Y. M o d e l : C R

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

TFA. KlimaLogg Pro. User Manual. Revision: 0.1

4-Channel Thermometer / Datalogger

User Guide. Temperature and Humidity Datalogger. Model 42280

Ron 3025 Crane Scale with 1"/25mm Display

Datalogger Graph Software Help

SNMP Web Management. User s Manual For SNMP Web Card/Box

Preparing Log-ic 360 USB Loggers for Use

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

FT-1000/GPS-N. System of remote monitoring and control of physical

SMS GSM Alarm Messenger

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

Wireless Data Logger Monitoring Systems

1. SAFETY INFORMATION

HOBO Single Channel Thermocouple Data Logger (UX M) Manual

User's Guide. Integrating Sound Level Datalogger. Model Introduction

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

USB-Based Temperature & Humidity Sensor

Temperature & Humidity SMS Alert Controller

DC Electronic Loads 8500 series

User Manual for CH-PFC76810

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

Measurement data monitoring with testo Saveris Small Business Edition. Instruction manual

5000V Graphical Megohmmeter Model 5070

Single Use USB Data Logger EBI 330-T30 / EBI 330-T85. User Manual

USER MANUAL V5.0 ST100

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

SHENZHEN JUNSI ELECTRONIC CO.,LTD

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Instruction Manual. T3111 T3111L T3111P T3111Ex

K-Type Thermocouple Sensor User s Guide

GSM HOME SECURITY SYSTEM

User Manual. Humidity-Temperature Chart Recorder. Model RH520

RS DIGITAL THERMOMETER

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

Nardalert S3 Non-Ionizing Radiation Monitor

SpO2 PULSE OXYMETER MD-300

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

GSR 12/24V. GSR 12/24V Technical manual Model 12/24

PTR/DTR. Printing Thermometer Software. Software User Manual

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Wahl C50 Calibrator FEATURES

ATL Fuel Level Sender Probes

Fingerprint Time Attendance Access System with Data Recording

SoundLAB Software Download Software from the Bogen website:

User Guide Reflow Toaster Oven Controller

USB Smart Power Sensor

INTEGRATED CIRCUITS. NE558 Quad timer. Product data Supersedes data of 2001 Aug Feb 14

NEULOG HEART RATE AND PULSE LOGGER SENSOR GUIDE

Dual Laser InfraRed (IR) Thermometer

Long Distance Industrial Wireless Transmitters and Receivers

WD-AMX Water Detection Controllers

CO2 Alarm. Operation. Application

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS

GPS Vehicle and personal location tracker. User manual

Transmitter Interface Program

GSM/3G UMTS/GPS/SMS Data Logger. The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA

Changers Kalhuohfummi User Manual

Drayton Digistat +2RF/+3RF

Manual. CANcaseXL CANcaseXL log. Version 5.1 English

SA-9600 Surface Area Software Manual

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

T0118 T2118 T3118. Instruction Manual

OCSM Series. High Resolution Digital Crane Scale. User Guide

BLE113 DEVELOPMENT KIT

Start an exciting career with the Larasian Group of. leading edge electronics and manufacturing companies

QLINK User Manual Stereo Audio Transmitter

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

ACR880 GPRS Portable Smart Card Terminal

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

Model UT713 OPERATING MANUAL

DG-100 Data Logger User Manual. Version 1.2

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Transcription:

4-20mA Current Loop USB Data Logger FEATURES 4-20mA current loop measurement range Logging rates between 1s and 12hr Stores 32,510 readings Connection via two screw terminals USB interface for set-up and data download User-programmable alarm thresholds Status indication via red and green LEDs Supplied with replaceable internal lithium battery and Windows control software ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery Replacement Cap EL-USB-4 BAT 3V6 1/2AA USB-CAP-4-20 This standalone data logger measures and stores up to 32,000 current loop readings over a 4-20mA measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the data logger into a PC s USB port and running the purpose designed software under Windows 2000, XP, Vista & 7. The data can then be graphed, printed and exported to other applications. The data logger is supplied complete with a long-life lithium battery. Correct functioning of the unit is indicated by a flashing red and green LED. The data logger features a pair of screw terminals and is supplied complete with a set of measurement leads terminating in crocodile clips. Specifications Minimum Typical Maximum Unit 0-40mA d.c. measurement range 4 20 ma d.c. Internal resolution 0.05 ma d.c. Accuracy (overall error) ±1 % ±1count Logging rate every 1s every 12 hr - Operating temperature range -35 (-31) 80 (176) C ( F) 1/2AA 3.6V Lithium Battery Life 1* Year * depending on ambient temperature, logging rate and use of alarm LEDs. EL-WIN-USB (CONTROL SOFTWARE) Lascar s EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control software runs under Windows 2000, XP, Vista & 7. The software is used to set-up the data logger as well as download, graph and export data to Excel. The software allows the following parameters to be configured: Logger name Logging rate (1s, 10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms Start date and start time The latest version of the control software may be downloaded free of charge from Specifications liable to change without prior warning Issue 9 07/2012 S.L Applies to EL-USB-4 Page 1 of 5

LED FLASHING MODES EL-USB-4 features a red and a green LED. By default hold is disabled. In this mode the red LED will no longer continue to flash after the logged reading has returned to normal from an alarm condition. Hold can be turned on via the control software. In this mode the red LED that indicates an alarm condition will continue to flash, even after the logged reading has returned to normal. This feature ensures that the user is notified that an alarm level has been exceeded, without the need to download the data from the logger. Green single flash (10 seconds) The data logger is currently logging. No alarm. Green single flash (20 seconds) The data logger is currently logging. No alarm. However, the battery is low and should be replaced before Green single flash (30 seconds) The data logger is not currently logging, but is primed to start at a later date and time (delayed start). Green double flash (20 seconds) The data logger is full and has stopped logging. No alarm. Red single flash (10 seconds) The data logger is currently logging. Low alarm. Red single flash (20 seconds) The data logger is currently logging. Low alarm. However, the battery is low and should be replaced before Green LED Red LED Red double flash (10 seconds) The data logger is currently logging. High alarm. Red double flash (20 seconds) The data logger is currently logging. High alarm. However, the battery is low and should be replaced before Red/Green single flash (20 seconds) The data logger is full and has stopped logging. Alarm (high, low or both). No LEDs flash The data logger is stopped, the battery is empty or there is no battery fitted. Specifications liable to change without prior warning Issue 9 07/2012 S.L Applies to EL-USB-4 Page 2 of 5

DIMENSIONS All dimensions in mm (inches) 26.8 (1.05) 26.8 (1.05) 98.0 (3.86) CONNECTION AND APPLICATIONS ve supply to sensor ve supply to sensor I out I in Signal out Sensor (current source) Sensor (current sink) Signal out 4-20mA current loop transmitter -ve/gnd supply to sensor -ve/gnd supply to sensor other 4-20mA current loop devices Connecting to a current loop transmitter Connecting to a current source sensor Connecting to a current sink sensor Specifications liable to change without prior warning Issue 9 07/2012 S.L Applies to EL-USB-4 Page 3 of 5

BATTERY REPLACEMENT We recommend that you replace the battery every 12 months, or prior to logging critical data. The EL-USB-4 does not lose its stored readings when the battery is discharged or when the battery is replaced; however, the data logging process will be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to a PC. Only use 3.6V 1/2AA lithium batteries. Check with your supplier that the battery you are ordering is press fit and is not fitted with solder tags. Before replacing the battery, remove the EL-USB-4 from the PC. Note: Leaving the EL-USB-4 plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. WARNING Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. Specifications liable to change without prior warning Issue 9 07/2012 S.L Applies to EL-USB-4 Page 4 of 5

THE EASYLOG USB RANGE Each EL-USB data logger features the direct-to-usb connection and easy-to-use functionality that the range is known for. The range comprises of the following data loggers: Part No Function Range Accuracy (overall error) Typ. Max. Readings Battery Battery Life* EL-USB-1 Temperature ±1ºC (±2ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-LCD Temperature with LCD ±0.5ºC (±1ºF) ±1.5ºC (±3ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-PRO High Temperature -40 to 125 C (-40 to 257 F) ±0.2ºC (±0.4ºF) ±0.5ºC (±1ºF) 32,510 3.6V ⅔AA 3 years EL-USB-1-RCG EL-USB-2 EL-USB-2 EL-USB-2-LCD Temperature with rechargeable battery Temperature, humidity & dew point Increased accuracy temperature, humidity & dew point Temperature, humidity & dew point with LCD -20 to 60 C (-4 to 140 F) ±1ºC (±2ºF) 32,510 Lithium Ion ±0.5ºC (±1ºF) ±3%RH ±0.3ºC (±0.6ºF) ±2.0%RH ±0.5ºC (±1ºF) ±3.0%RH ±2ºC (±4ºF) ±6.0%RH ±1.5ºC (±3ºF) ±4.0%RH ±2ºC (±4ºF) ±6.0%RH 1 month (rechargeable) 16,382 3.6V ½AA 1 year 16,382 3.6V ½AA 1 year 16,379 3.6V ½AA 1 year Increased accuracy temperature, ±0.3ºC (±0.6ºF) ±1.5ºC (±3ºF) EL-USB-2-LCD humidity & dew 16,379 3.6V ½AA 1 year point with LCD ±2.0%RH ±4.0%RH EL-USB-3 Voltage 0 to 30V d.c. ±1% 32,510 3.6V ½AA 1 year EL-USB-4 Current loop 4 to 20mA ±1% 32,510 3.6V ½AA 1 year EL-USB-5 Counter, Event & State N/A ±3 secs/24 hrs 32,510 3.6V ½AA 1 year EL-USB-TC Thermocouple (J, K and T- type) K-type probe included -200 to 1350ºC (-328 to 2462ºF) (K-type) -200 to 1190ºC (-328 to 2174ºF) (J-type) -200 to 390ºC (-328 to 734ºF) (T-type) ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months -200 to 1350ºC (-328 to 2462ºF) (K-type) EL-USB-TC-LCD Thermocouple with LCD (J, K and T-type) K-type probe -200 to 1190ºC (-328 to 2174ºF) (J-type) ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months included -200 to 390ºC (-328 to 734ºF) (T-type) EL-USB-CO Carbon monoxide 0 to 1000ppm NOT A LIFE SAVING DEVICE ±6ppm 32,510 3.6V ½AA 3 months EL-USB-CO300 Carbon monoxide 0 to 300ppm NOT A LIFE SAVING DEVICE ±4ppm 32,510 3.6V ½AA 3 months EL-USB-LITE Low cost temperature -10 C to 50 C (14 to 122 F) ±1ºC (±2ºF) 4,080 CR1620 Lithium coin cell 1 month EL-USB-RT Real-time temperature & humidity monitor -20 to 70 C (-4 to 158 F) *Depending on logging rate, ambient temperature, and use of alarm LED ±1.5ºC (±3ºF) ±4.5%RH 7 days N/A N/A Module House Whiteparish, Salisbury Wiltshire SP5 2SJ UK T 44 (1794) 884567 F 44 (1794) 884616 E sales@lascar.co.uk 4258 West 12th Street Erie PA 16505 USA T 1 (814) 835 0621 F 1 (814) 838 8141 E us-sales@lascarelectronics.com 8th Floor, China Aerospace Centre 143 Hoi Bun Road Kwun Tong, Kowloon HONG KONG T 852 2797 3219 F 852 2343 6187 E saleshk@lascar.com.hk Specifications liable to change without prior warning Issue 9 07/2012 S.L Applies to EL-USB-4 Page 5 of 5