Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION



Similar documents
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Cambridge Electric Infared Fireplace User Manual

OWNER S MANUAL HH200M 6.12

Ducoterra Radiant Heating Panel Installation Manual

Installation & Maintenance Instructions

Installation Instructions

OPERATING MANUAL ASSEMBLY. Remote control docks magnetically. click. until it clicks and locks. REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

MICATHERMIC FLAT PANEL RADIATOR IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

ELECTRIC OIL FILLED RADIATORS IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

INFRARED QUARTZ WALL HEATER

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

E2 Series Electric Furnaces

For Models #6-5001, #6-7501, # & #10-12K1

ELECTRIC OIL-FILLED RADIATORS IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

D I G I T A L C L A M

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

CARING FOR YOUR WATER HEATER

Safety, Operation and Maintenance Manual with Parts List

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

INSTALLATION & USER INSTRUCTIONS

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

HM-W536 Install Guide

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Operating Instructions

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Oil and Coolant Circulating Heating System. Model - OCSM

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

SL280UHV SERIES GAS FURNACE WARNING

GenStore Archive Cabinet

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

Triac Printed Circuit Board Replacement

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

IMPORTANT SAFETY INFORMATION:

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

HOUSING QUALITY STANDARDS (HQS)

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

WARMER or COOKER/WARMER

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

Single Phase Soft Starter

Meaco 30L and Meaco 40L dehumidifier instruction manual

Cooktop Low-Profile Ventilation Hoods

SMD Rework Station TABLE OF CONTENTS

HYLA NST Cleaning System

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

AIR CONDITIONER INSTALLATION MANUAL

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Contact Details. Please note that some of the contact details on this PDF document may not be current.

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Advantium 2 Plus Alarm

QT Residential Blower Metal Residential Blower

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Andersen Electric Window Opener for Andersen Awning and Roof Windows

INSTALLATION INSTRUCTIONS

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

16/32 Channel 1U Rack Mount CCTV Power Supply

HP UPS R1500 Generation 3

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Your safety and the safety of others are very important.

Multi-Pitch Pitching Machine USER MANUAL

Get Me Cool Now Portable Air Conditioner User s Manual

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

Portable Air Conditioner

Installation Instructions for Alarm Module Kit A043F059

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Heat Tracing Sales Mt. Airy, Maryland Installation Instructions

3000W Power Inverter

Bubble King. User Manual

October Safety Subject

12. Inspection and Maintenance

Digi-Motor Installation Guide

Air Conditioner B B

Series Hose Reels

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

GoFit Platinum Power Vibe

Installation Instructions

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Transcription:

Chromalox Installation, Operation RENEWAL PARTS IDENTIFICATION Portable Industrial Unit Blower Air Type DRA and DIVISION SALES REFERENCE DATE SECTION (Supersedes P-) PF-) NOVEMBER, 00 DRA PF- -0-00 Specifications Table Electrical Data (0 Hz) Dimensions (In.) Model Volts kw Phase Amps* / Ph BTU Height Width Depth DRA-0-0. and./.0,0.. DRA-0-0/0./. and./.**,0.. DRA-0-0. and./.,.. DRA-0-0/0./. and 0./.**,.. DRA-- 0.,0.. DRA-- 0/0 /..**,0.. DRA-- 0 and./.,0.. DRA-- 00 and./.,0.. DRA-0-0/0./.**,... DRA-0-0 0 and.0/.,0... DRA-0-00 0 and./.,0... DRA-0-0 0. 0,0... DRA-0-00 0 0. 0,0... * = Includes motor amps ** = Ratings shown are for 0V, 0V amperage is % of 0V value. Models shown as and phase are factory wired for phase operation and can be field wired for single phase. IMPORTANT: SAVE THESE INSTRUCTIONS Risk of fire. Do not use as a residential or household heater. ENERAL such fabrics away from heater. Do not operate heater where flammable vapors, gases or liquids are present. s in the heat mode should not be operated in room temperatures above 0 F. Fan motor is not designed to operate in ambients below -0 F. To avoid personal injury read IMPORTANT INSTRUCTIONS on page before installation or operation of heater. Hazard of Fire or Discoloration of Temperature Sensitive Fabrics. Do not use as a residential or household heater. Keep combustible material and Keep electrical cords and combustible materials, such as drapes and other furnishings, away from heater. 00 Chromalox, Inc.

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:. Read all instructions before using this heater.. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this heater. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least feet (0. m) from the front of the heater and keep them away from the sides and rear.. Extreme caution is necessary when any heater is used by or near children or handicapped individuals and whenever the heater is left operating and unattended.. Always disconnect heater when not in use.. Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been dropped or damaged in any manner. Return heater to authorized service facility for examination, electrical or mechanical adjustments, or repair.. Do not use outdoors.. This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container. IMPORTANT INSTRUCTIONS. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Arrange cord away from traffic area and where it will not be tripped over.. To disconnect heater, turn thermostat off, then remove plug from outlet. 0. Connect to properly grounded outlets only.. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, fire or damage the heater.. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where opening may become blocked.. A heater has hot and arcing or sparking parts inside.do not use it in areas where gasoline, paint or flammable liquids are used or stored.. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.. This heater is not intended for use with an extension cord.. SAVE THESE INSTRUCTIONS. ASSEMBLY INSTRUCTIONS The Chromalox DRA is shipped fully assembled. The handle is assembled in the lower position (dotted line Fig. ). To position handle in the upright position, remove bolts securing the handle to the support legs, lift handle until the handle holes line up with the upper holes in the support legs and insert bolts to secure the handle in the full upright position. Handle Tools Required Crescent Wrench Phillips Screwdriver Direction of Airflow Bolt ( ) Nut ( ) Support Leg Figure WIRIN ELECTRIC SHOCK HAARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property damage. must be effectively grounded in accordance with the National Electrical Code, NFPA 0.. Use heater only on the voltage and frequency specified on the nameplate.. All wiring should be done in accordance with local codes and the National Electrical Code by a qualified person.. Branch circuit wire for connection to heater must be at least 0 C wire.. The top access panel is secured by screws that must be loosened to gain access.. A ground terminal is provided near the power terminal board. The ground wire should be connected before other connections are made.. Refer to Chart A for proper size SO grade cable.. A proper strain relief must be used with SO grade cable.. Dragon heaters are factory pre-wired for -phase delta operation. Some units can be converted to single phase operation by changing the wiring. Refer to Chart A for those heaters that can be converted to single phase. The appropriate wiring diagram is also located on the back of the wiring compartment cover.

WIRIN Chart A Cable and Plug Selection Wiring Wire Cord Set Optional Plugs Model kw Volts Phase Diag. No. Amps Size Chromalox Catalog No. Locking Type Non Lock Type DRA-0-. 0 A. / PLC-0- PN--0 DRA-0-. 0.0 0/ PLC-0- PL--0 PN--0 DRA-0-. 0 A. 0/ PLC-0- PL--0 PN--0 DRA-0-. 0. / PLC-- PL--0 PN--0 DRA-0-. 0 A. / PLC-0- PN--0 DRA-0-. 0. / PLC-- PL--0 PN--0 DRA-0-. 0 A. / PLC-0- PN--0 DRA-0-. 0. / PLC-0- PL--0 PN--0 DRA-0-. 0 A. / PLC-0- PN--0 DRA-0-. 0 0. 0/ PLC-0- PL--0 PN--0 DRA-0-. 0 A 0. / PLC-0- PN--0 DRA-0-. 0. 0/ PLC-0- PN--0 DRA-- 0. / PLC-0- PN--0 DRA--. 0. / PLC-0- PN--0 DRA-- 0. / PLC-0- PN--0 DRA-- 0 A. / PLC-0- PL-C DRA-- 0. / PLC-- PL--0 DRA-- 00 A. 0/ PLC-0- PL-C DRA-- 00. / PLC-- PL--0 DRA-0-0. / PLC-0- PN--0 DRA-0-0 0. / PLC-0- PN--0 DRA-0-0 0 A. / PLC-0- PL-C DRA-0-0 0. 0/ PLC-0- PL--0 DRA-0-0 00 A. / PLC-0- PL-C DRA-0-0 00. / PLC-- PL--0 DRA-0-0 0. / PLC-0- PL-C DRA-0-0 00. / PLC-0- PL--0 Power Cord based on 00V Hard Service Cord Rated 0 C Plug selection is based on using Chromalox Cable Kits Plug Selection Fits Cable Dia. Plug Type Model Description Volts Amps Configuration NEMA # ANSI #. -.0 Locking PL--0 Pole, Wire 0 0 Y L-0 C.. -.0 Locking PL--0 Pole, Wire 0 0 Y L-0 C.. -.0 Locking PL--0 Pole, Wire 0 0 Y L-0 C.. -.0 Locking PL--0 Pole, Wire 00 0 Y L-0 C. Y.0 -. Locking PL-C Pole, Wire 00 0 Y.0 -. Locking PL-C Pole, Wire 00 0. -. Non Locking PN--0 Pole, Wire 0 0-0 C..0 -. Non Locking PN--0 Pole, Wire 0 0-0 C. W.0 -.0 Non Locking PN--0 Pole, Wire 0 0-0 C. W The above plugs are designed to be used with specific ranges of cable diameters. If not used with Chromalox Cable Kits, check cable manufacturers cable diameter to be sure plug fits selected cable.

WIRIN Cord Preparation for Chromalox Portable s. Determine the gage and number of conductors from the tabulation below using amps and phase from the heater nameplate. It is not recommended that cord exceed 0 feet in length. Max. Amps Chromalox Cord Kit* Cord a/no. Cond. and Type Model No. Phase Phase PLC-- / SO 0 PLC-- / SO 0 PLC-0-0/ SO PLC-0-0/ SO 0 PLC-0- / SO PLC-0- / SO PLC-0- / SO PLC-0- / SO 0 PLC-0- / SO *Includes 0 degree fitting and foot of cord, reducers and locknut. Strip off outer jacket of cord and insulation from lead wires. The tabulation below provides the strip dimensions for the various Chromalox portable heaters. See the nameplate on the heater for the Model number. Model No. A B C DRA - (all suffixes) 0.. Slide fitting onto cord and tighten knurled nut to secure fitting to cord.. Select plug to match electrical rating of cord.. On opposite end of cord prepare end as directed by instructions that are provided with the plug.. Attach cord assembly to heater as shown in Fig. below: Run wire tie through slots in bracket and over cord. Pull tab of wire tie to provide cord strain relief. Power wires 0 fitting round wire Figure "A" "B" (Insulation strip dimension for ground wire). "C" (Insulation strip dimension for power wires). OPERATION THERMOSTAT s include a bimetal thermostat for the automatic control of the exiting air temperature. The thermostat knob controls the heating elements and fan functions. The heater and fan are deenergized with the knob in the extreme clockwise position. Turning the knob clockwise from the off position to the fan position will energize the fan only, for use in summer cooling. The adjustment knob controls power to the heater and fan when turned further in the clockwise direction, with the highest temperature setting in the extreme clockwise position. The temperature setting in the heater mode is approximately 0 F in the low setting and 00 F at the highest setting. Note: The adjustment knob should be turned to the fan only setting after use for heating. The fan should be left on for at least minutes to remove residual heat from the unit and to prevent overheating of the housing.

WIRIN DIARAMS Diag. FACTORY WIRED PHASE Diag. a FIELD CONVERSION TO PHASE L L L T T T Blu Wht Red L L T T All control wiring same as Diag. Instructions:. Loosen screws on load side of contactor. Remove all lead wire.. Insert lead wires numbers,, and into box lug connector "T". Tighten screws on box lug connector.. Insert lead wires numbers,, and into box lug connector "T". Tighten screws on box lug connector.. Examine wiring to make certain it is per above diagram. L L L Diag. FACTORY WIRED PHASE To T T T T Fan Relay L T L T A A Wht To T /Red or rey To T To T To T To T FMR Black White L L Diag. a FIELD CONVERSION TO PHASE T T All control wiring same as Diag. All even numbered wires to T All odd numbered wires to T Instructions:. Loosen screws on load side of contactor. Remove all lead wire.. Insert lead wires numbers,, and into box lug connector "T".. Insert lead wires numbers,, and into box lug connector "T".. Examine wiring to make certain it is per above diagram. Diag. FACTORY WIRED PHASE L L L T T T 0 To T To T To T To T To T To T 0 Blue Red Black White L L L Diag. FACTORY WIRED PHASE T T T 0 Fan Relay L T L T A A To T To T To T To T Wht To T To T /Red or rey FMR Black White 0 L L T T All control wiring same as Diag. Diag. a FIELD CONVERSION TO PHASE 0 All even numbered wires to T All odd numbered wires to T Instructions:. Loosen screws on load side of contactor. Remove all lead wire.. Insert lead wires numbers,,,, and into box lug connector "T".. Insert lead wires numbers,,,, 0 and into box lug connector "T".. Examine wiring to make certain it is per above diagram. 0

MAINTENANCE ELECTRIC SHOCK HAARD. Disconnect heater from power supply before servicing and/or inspecting the heater; failure to do so may result in electrical shock. Replace or repair damaged cords or plugs immediately. Check tightness of all electrical connections prior to energizing Dragon. Blow out or vacuum away any dirt or debries that may have accumulated around the control enclosure fan motor or heating elements. RENEWAL PARTS IDENTIFICATION Element Fan Control Model No. Volts kw Phase Part No. Part No. Part No. Part No. Trans/ DRA-0-0. and -0-00 0-0-0 DRA-0-0. and -0-00 0-0-0 DRA-0-0. and -0-00 -00-00 0-0-0 DRA-0-0. and -0-00 0-0-0 DRA-- 0-0-00 0-0-0 DRA-- 0-0-00 0-0-0 DRA-- 0 and -0-00 -00-0 0-0-00-0-00 DRA-- 00 and -0-00 -00-0 -0-00 0-0-00-0-00 DRA-0-0. -0-00 -00-00 0-0-0 DRA-0-0 0 and -0-00 -00-0 0-0-00-0-00 DRA-0-00 0 and -0-00 -00-0 0-0-00-0-00 DRA-0-* 0 0 DRA-0-* 00 0-0-0a -00-0 0-0-00-0-00-0-0b -0-0a -00-0 0-0-00-0-00-0-0b 0 kw units contain two sets of three elements (six total). The ratings of the three elements on the discharge end have a lower wattage than the elements on the fan end of heater. The ends of the elements are color coded, the lower wattage are color coded yellow and the higher wattage are color coded blue. a. Lower wattage elements, discharge end, yellow coded b. Higher wattage elements, fan end, blue coded PARTS COMMON TO ALL UNITS Description Part No. Wheels --00 rille -00-00 00-0-00 Thermal Cut-out 00-00-00 Fan Relay (not used on 0 and 0V Models) 0--0 Limited Warranty: Please refer to the Chromalox limited warranty applicable to this product at http://www.chromalox.com/customer-service/policies/termsofsale.aspx. 0 N. RULON WHITE BLVD., ODEN, UT 0 Phone: -00-- www.chromalox.com