PUMP DRIVES ENTRAÎNEMENTS DE POMPES PUMPENANTRIEBE MOTOR DE BOMBAS UNITÀ DI CONTROLLO POMPA 77410-10 77411-00 OPERATING MANUAL: MODE D EMPLOI:



Similar documents
DC POWER SUPPLY ALIMENTATION C.C.

How To Use A Power Supply Unit (Upu)

Thermistor Thermometer MODEL NO

TIG INVERTER INSTRUCTION MANUAL

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

±15 V Current-Limited Power Supply

How To Use A Cdm250 Digital Multimeter

User Guide. 4 wire Earth Resistance Tester Model GRT300

Electric Rotary Actuator - On/Off or programmable control actuator

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Congratulations! Thank you!

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Electronic Pressure Switch EDS 300

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

ATL Fuel Level Sender Probes

Absolute Rotary Encoder E6CP

LED...A Q Series Sealed High-Intensity

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

Online UPS. PowerWalker VFI 1000R/1U

Streaming Potential System (SPT1000, SPD1000)

Air damper actuators

Manual Ranging MultiMeter

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

User s Manual AURORA 1.2K/2.2K

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

User s Manual Before using the inverter, you need to read and save the safety instructions.

XP Series Balances Operation Manual

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Use and Care Manual. Model CPA12KH AIR CONDITIONER

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

User Manual. CFG253 3 MHz Function Generator

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Agilent 87421A/87422A Power Supply

Product and functional description

Multi-Range Programmable DC Power Supplies 9115 Series

LOXONE 12 Channel Amplifier

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

T7079A,B Solid State Remote Temperature Controllers

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

! WARNING. Before using product, read and understand instructions.

A1000 Cheat Sheet (Open Loop Vector)

HERZ-Thermal Actuators

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

WD-AMX Water Detection Controllers

19 LED Tube Controller ORDERCODE 41003

16/32 Channel 1U Rack Mount CCTV Power Supply

Antenna Splitter ASA 1. Instruction manual

I STAR COMPUTER CO., LTD

Installation, Operation and Maintenance Manual

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

MANUAL ENGLISH. Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Speed Control Relays SX2

=============================== WARNING

Oil and Coolant Circulating Heating System. Model - OCSM

Thermocouple Thermometer Models

IP DSLAM IDL Quick Installation Guide

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Notice. Reverse engineering and disassembly are prohibited.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Number 1 in efficiency

7 FUNCTION DIGITAL MULTIMETER

Technical Update TAA.TU Rev. 1

PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

ACS-30-EU-EMDR-10-MOD

Operating Manual Color Changing Fountains

Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH

MOUNTING AND OPERATING INSTRUCTIONS

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Digital input modules

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

64-CHANNEL INTEGRATED AMPLIFIER

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Givare NC-SRS 280 och 880

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Duct Humidity Transmitter

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Transcription:

OPERATING MANUAL: PUMP DRIVES pages 1-10 MODE D EMPLOI: ENTRAÎNEMENTS DE POMPES F1-F10 BETRIEBSANLEITUNG: PUMPENANTRIEBE D1-D10 77411-00 pump drive Model Nos. N de modèle Modellnummer Número de modelo Modello nº 77410-10 77411-00 MANUAL DE FUNCIONAMIENTO: MOTOR DE BOMBAS E1-E10 MANUALE DI ISTRUZIONI: UNITÀ DI CONTROLLO POMPA T1-T10 Cole-Parmer Instrument Co. 1-800-MASTERFLEX (627-8373) (U.S. and Canada only) 11 (847) 549-7600 (Outside U.S.) (847) 549-7600 (Local) www.masterflex.com Barnant Company 1-800-637-3739 (U.S. and Canada only) 11 (847) 381-7050 (Outside U.S.) (847) 381-7050 (Local) www.barnant.com A-1299-1037 Edition 02 1

TABLE OF CONTENTS Title SAFETY PRECAUTIONS.....................................................................2 INTRODUCTION...............................................................................3 CONTROL/DISPLAY FUNCTIONS...........................................................3 SETUP AND DRIVE OPERATION............................................................3 Automatic Start Enable/Disable............................................................4 REMOTE CONTROL..........................................................................5 Remote Control Setup......................................................................5 Internal / External Operation...............................................................5 TROUBLESHOOTING AND MAINTENANCE...............................................7 Fuse Replacement..........................................................................7 Troubleshooting.............................................................................7 Cleaning.....................................................................................8 Replacement Parts and Accessories.......................................................8 SPECIFICATIONS............................................................................. 9 TECHNICAL ASSISTANCE..................................................................10 SAFETY PRECAUTIONS WARNINGS: CAUTIONS: No user serviceable parts inside. Do not remove covers. Refer servicing to your dealer. Tubing breakage may result in fluid being sprayed from pump. Use appropriate measures to protect operator and equipment. Turn drive off before removing or installing tubing. Fingers or loose clothing could get caught in drive mechanism. To avoid electrical shock, the power cord protective grounding conductor must be connected to ground. Not for operation in wet locations as defined by EN 61010-1. Do not stack drives. Keep 3" minimum distance around and above drive for proper cooling. WARNING: PRODUCT USE LIMITATION This product is not designed for, nor intended for use in, patientconnected applications, including, but not limited to, medical and dental use, and, accordingly, has not been submitted for FDA approval. If drive is used in a manner not specified in this manual the protection provided by the equipment may be impaired. 2

INTRODUCTION The brushless drive controls the speed of Masterflex I/P pump heads to provide variable flow rates from 0.2 to 17 L/min (0.06 to 4.5 gallons/min). Achieve up to 26 LPM (7 GPM) with two stacked Standard or EASY-LOAD I/P pump heads. One Masterflex High-Performance I/P pump head may be driven. CONTROL/DISPLAY FUNCTIONS Press keys to activate function. 77410-10 77411-00 B A B A D C C Figure 1 A. STOP/START Start/Stop pump. B. DIRECTION To change motor direction. C. SPEED Selects output speed from 5 to 100% Full Scale (33 to 650 RPM). Clockwise rotation increases speed. D. INT/EXT (Model 77411-00 only) INT for internal control; EXT for remote current or voltage control. 3

SETUP AND DRIVE OPERATION 1. Attach any external control connections. (Model 77411-00 only) 2. Mount pump head and load tubing (see pump head manual). NOTE: The High-Performance I/P pump is mounted with the tubing to the left. The Standard I/P pump is mounted with the tubing up. The Easy-Load I/P pump is mounted with the occlusion bed up. 3. Turn drive on. 4. Select INTernal or EXTernal operation. (Model 77411-00 only) 5. Select pump DIRection (clockwise or counter-clockwise). 6. Press STOP/START key to begin pumping. 7. Adjust speed (listed flow rates are for reference only. Flow will vary with pressure, tubing, viscosity, and time): Speed Setting I/P 26 I/P 73 I/P 82 I/P 70 I/P 88 I/P 89 10% 0.4 LPM 0.8 GPM 1.3 LPM 0.8 LPM 1.3 LPM 1.7 LPM 0.11 GPM 0.21 GPM 0.35 GPM 0.21 GPM 0.35 GPM 0.45 GPM 20% 0.8 LPM 1.6 LPM 2.6 LPM 1.6 LPM 2.6 LPM 3.4 LPM 0.22 GPM 0.42 GPM 0.70 GPM 0.42 GPM 0.70 GPM 0.90 GPM 30% 1.2 LPM 2.4 LPM 3.9 LPM 2.4 LPM 3.9 LPM 5.1 LPM 0.33 GPM 0.63 GPM 1.05 GPM 0.63 GPM 1.05 GPM 1.35 GPM 40% 1.6 LPM 3.2 LPM 5.2 LPM 3.2 LPM 5.2 LPM 6.8 LPM 0.44 GPM 0.84 GPM 1.40 GPM 0.84 GPM 1.40 GPM 1.80 GPM 50% 2.0 LPM 4.0 LPM 6.5 LPM 4.0 LPM 6.5 LPM 8.5 LPM 0.55 GPM 1.05 GPM 1.75 GPM 1.05 GPM 1.75 GPM 2.25 GPM 60% 2.4 LPM 4.8 LPM 7.8 LPM 4.8 LPM 7.8 LPM 10 LPM 0.66 GPM 1.26 GPM 2.1 GPM 1.26 GPM 2.1 GPM 2.70 GPM 70% 2.8 LPM 5.6 LPM 9.1 LPM 5.6 LPM 9.1 LPM 12 LPM 0.77 GPM 1.47 GPM 2.45 GPM 1.47 GPM 2.45 GPM 3.15 GPM 80% 3.2 LPM 6.4 LPM 10 LPM 6.4 LPM 10 LPM 14 LPM 0.88 GPM 1.68 GPM 2.8 GPM 1.68 GPM 2.8 GPM 3.60 GPM 90% 3.6 LPM 7.2 LPM 12 LPM 7.2 LPM 12 LPM 15 LPM 0.99 GPM 1.89 GPM 3.15 GPM 1.89 GPM 3.15 GPM 4.05 GPM 100% 4 LPM 8 LPM 13 LPM 8 LPM 13 LPM 17 LPM 1.1 GPM 2.1 GPM 3.5 GPM 2.1 GPM 3.5 GPM 4.5 GPM NOTE: While in INTernal mode, drive will automatically restart after a brownout or power out condition unless operator changes default setting. If speed is being controlled by an external signal, drive will automatically restart with a non-zero speed command. AUTOMATIC START ON/OFF (Internal mode only) Press and hold DIR on power-up. After five (5) seconds, display will read ON (factory default) or OFF. Hold the DIR key for an additional 3 seconds and the display will toggle to the other option every 3 seconds. Release the DIR key when the desired mode is being displayed. After releasing the key, ON or OFF will remain displayed for about 3 seconds and then the normal power-on sequence will begin. When ON is selected, drive will start automatically at power-up if it was running when powered down. 4

REMOTE CONTROL (Model 77411-00 only) Selectable input (4 20 ma, 0 10V DC ) ±0.5% linearity control ±50V common mode range with respect to earth ground Internal & External START/STOP; External CW/CCW via contact closure REMOTE CONTROL SETUP 1. Place the power switch in the off position. 2. Connect the cable from the external remote control to the mating receptacle on the rear panel. 3. Select operation from front panel potentiometer, external 4-20mA current source, or external 0-10 V voltage source as follows: a. Press and hold the INT/EXT control for approximately 5 seconds until the present setting of the speed source is displayed. b. Continuing to hold the INT/EXT control will cause the display to cycle through the three choices: 4.20 indicating the 4-20 ma input, 0.10" indicating the 0-10 V input, or Pot indicating that the Speed Input Potentiometer will be used. When the key is released, the programmed choice will remain on the display for approximately 3 seconds as confirmation of the speed source choice made before returning to normal operation. 4. To adjust the voltage or current scaling for other than zero to full scale: a. Press and hold the INT/EXT control (approximately 5 seconds) until the external speed source is displayed. ( 4.20, 0.10, or Pot ) b. Release the INT/EXT control and press the DIR control before the external speed source disappears from the display. c. The display will show Lo for about 3 seconds and then flash the current speed setting for the low set point (4 ma or 0 V). To change this setting, adjust the Speed Control Potentiometer to the percent of full speed desired. To make no change, press the DIR control a second time. d. After pressing the DIR control the second time, the display will show Hi and then flash the high (20 ma or 10 V) speed set point. This can be changed by adjusting the Speed Control Potentiometer, or left as is by pressing the DIR control again. e. The third press of the DIR control returns the drive to normal operation. NOTE: The 4-20 ma input, the 0-10 V input, and the 4-20 ma output are not scaled separately. INTernal / EXTernal Operation 1. The EXTernal mode of operation enables the PUMP READY output, the EXTERNAL START/STOP, EXTERNAL CW/CCW, 4-20 ma, and 0-10 V inputs, while disabling the INTERNAL START/STOP input (e.g. footswitch) and front-panel DIR and START controls. The pump speed is determined by the programmed choice of 4-20 ma, 0-10 V, or front panel potentiometer inputs. The front panel STOP/START control overrides the EXTERNAL START/STOP input to stop the drive. 2. In the INTernal mode of operation, either the INTERNAL START/STOP input (e.g. footswitch) or the front panel STOP/START control can start or stop the drive at the speed set by the front-panel SPEED POT. 5

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Figure 2 RED/YELLOW BLUE NOTE: Colors are those of Remote Cable. Catalog number 77300-32 GREEN + EXTERNAL START/STOP + EXTERNAL CW/CCW + INTERNAL START/STOP GREY YELLOW TAN (RESERVED) WHITE 3 PINK INPUT 4-20mA ORANGE RED/GREEN PUMP READY N.O. CONTACT INPUT 0-10V BLACK RED/BLACK PUMP READY N.C. CONTACT BROWN N.C. OUTPUT 4-20mA VIOLET N.C. RED (RESERVED) N.C. 6

TROUBLESHOOTING AND MAINTENANCE FUSE REPLACEMENT 1 Place the power switch in the off position. 2 Disconnect the AC power input line cord from the attached line and receptacle. 3 Remove and check the fuse and replace if defective 4 Reconnect the AC power input line cord to the receptacle. Figure 3 A. T6.3A Fuse (CAUTION: Do not substitute.) B. External receptacle for remote control C. IEC 320 Power cord D. Power switch A B C D TROUBLESHOOTING SYMPTOM CAUSE REMEDY A Motor does not rotate A No power 1 Check fuse and replace if defective (Fig. 3) Display does not light 2 Check that unit is plugged into a live line 3 Check connection of power cord 4 Check the line cord for continuity and replace if defective 5 Return for servicing B Motor does not rotate B1 Defective remote 1 Place power switch in off position Display lights control 2 Check that remote cable connector is inserted fully into the receptacle (Fig. 2 and 3) 3 If motor still does not rotate, select INTernal with the INT/EXT control and press the STOP/START control (Fig. 1) 4 If the motor rotates, replace the remote control with similar unit. If motor does not rotate, return drive for servicing B2 INT/EXT control 1 Check that the INT/EXT control is set to INT for not properly set operation with front panel control or to EXT for with operation remote control (Fig. 1) 2 If motor still does not rotate, return for servicing Troubleshooting continued on page 8 7

TROUBLESHOOTING (Continued) If an error message is displayed, refer to the following list for possible corrective actions you can take. If these do not correct the problem, contact your dealer. ERROR MESSAGE CAUSE REMEDY Err 2 Motor over-speed 1 Clear by pressing any key 2 Check for proper tube loading and pump operation 3 Return unit for repair if the error persists Err 3 Overload 1 Clear by pressing any key Err 5 2 Check for proper tube loading and pump operation Err 12 3 Return unit for repair if the error persists Err 7 Bad data Operator 1 Clear by pressing any key parameters set to 2 Reprogram operator parameters default values 3 Return unit for repair if the error persists Err 10 Voltage out of range 1 Clear by pressing any key Err 11 2 Check that AC line voltage is within specified voltage ranges 3 Return unit for repair if AC line voltage is correct and the error persists Err 13" Over temperature 1 Check for heat sources or obstructions to cooling Err 14" 2 Check for proper tube loading and pump operation 3 Allow unit to cool Clear by pressing any key 4 Return unit for repair if no cause for overheating is found and the error persists All other errors Internal error or failure 1 Clear (if possible) by turning power off and on 2 Return unit for repair if the error persists CLEANING Keep the drive enclosure clean with mild detergents. Do not immerse. REPLACEMENT PARTS & ACCESSORIES 77500-24 Fuse T6.3A 5 x 20 mm 07595-43 Footswitch 77300-32 Remote control cable, 25 ft (7.62 m) 8

SPECIFICATIONS OUTPUT Speed: 33 to 650 rpm Torque output, maximum: Continuous 540 oz-in (39 kg-cm) @ 25 C Ambient 380 oz-in (27 kg-cm) @ 40 C Ambient Start-up 960 oz-in (69 kg-cm) Speed regulation: Line ±0.25% F.S. Load ±0.25% F.S. Drift ±0.25% F.S. Display: Three-digit, seven-segment LED Remote outputs: Current speed output (4 20 ma @ 0 600 Ω) (Model 77411-00 only) Pump ready output (N.O. & N.C. contact closure, 1A @ 28V AC/DC) INPUT Supply voltage limits: Universal Input - 90 to 260 Vrms @ 50/60 Hz, Single Phase Current, maximum 4.5A @ 115 Vrms, or 2.6A @ 230 Vrms Remote Inputs: Internal & External START/STOP (Contact closures) (Model 77411-00 only) External CW/CCW (Contact closure) Voltage input (0 10V DC @ 10 kω) Current input (4 20 ma @ 250 Ω) CONSTRUCTION Dimensions (L x W x H): 14.0" x 10" x 9.1" (35 cm x 25 cm x 23 cm) Weight: 22 lb (10 kg) Enclosure rating: IP55 per IEC 60529 ENVIRONMENT Temperature, operating: 0 to 40 C (32 to 104 F) Temperature, storage: 25 to 65 C ( 13 to 149 F) Humidity (non-condensing): 10 to 100% Altitude: Less than 2000 m Pollution degree: Pollution Degree 3 (Indoor use sheltered locations) Chemical resistance: Enclosure is painted steel COMPLIANCE UL508C, CSA C22.2, No. 14 (For CE Mark): EN61010-1 (EU Low Voltage Directive) and EN61326 (EU EMC Directive) 9

TECHNICAL ASSISTANCE If you have any questions about the use of this product, contact the Manufacturer or authorized seller. Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 1-800-MASTERFLEX (627-8373) (U.S. and Canada only) 11-847-549-7600 (Outside U.S.) 847-549-4600 (Local) FAX 847-247-2929 (U.S. and Canada only) 11-847-549-1700 (Fax outside U.S.) www.masterflex.com e-mail:techinfo@coleparmer.com 28W092 Commercial Ave. Barrington, Illinois U.S.A. 60010-2392 1-800-637-3739 (U.S. and Canada only) 11-847-381-7050 (Outside U.S.) 847-381-7050 (Local) FAX 11 847-381-7053 (Fax outside U.S.) 847-381-7053 (Local Fax) www.barnant.com e-mail:barnant@barnant.com 10