Recreational Vehicles



Similar documents
Outdoor Cooking. Gas pressure Regulators & Accessories 2012 EDITION LPG & NATURAL GAS REGULATORS RE-02 DIVISION

NAVIEN AMERICA INC FITCH AVENUE

SELECTION, APPLICATION & MAINTENANCE

Your safety and the safety of others are very important.

NITROUS TRANSFER PUMP INSTRUCTIONS

SELECTION, APPLICATION AND MAINTENANCE

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

AIR OPERATED OIL PUMPS AND KITS

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

LPM-06 CONVERSION KIT

Element D Services Plumbing

Commercial Gas Water Heaters

AIR LINE VALVES AND GAUGES

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Incorrect use or failure of pressure regulators

MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder

AUTOMATIC CHANGEOVER MANIFOLD Series 915

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

ASX7-4-IOM-7 J

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

A/C refrigerant system, overview

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

FILLING AND PURGING THE SYSTEM

Gas Line Sizing. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system.

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

Horns. Buzzers , Compressed air horns Disc-type horns Electric twin-tone horns 6.08

PARTS NEEDED FOR CONVERTING FROM LP TO NG

SunMaxx Solar Filling Station Operating Instructions

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Before installation it is important to know what parts you have and what the capabilities of these parts are.

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Welding Reels HANNAY REELS. For use for: Arc Welding Gas Welding Cutting Operations H-9422-W Rev. 5. The reel leader.

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC

RIVET BUSTERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

HELIPORT FUEL/WATER SEPARATOR MODEL H-200

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

SF15K SF05KSS, SF10KSS

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * Thermostat for CH 12/18

INSTALLATION MANUAL MODEL RP-100

Copper Meter Resetters

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

AMX300 DirectConnect Mixing Valve Kits

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

HeatSource HS1800 Heater

Universal Adjustable Fuel Pressure Regulator

Commercial Gas Water Heaters

Portable Air Conditioner

Model 43AP Pneumatic Controller, Style B

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

Operators manual Basic water heater

RECON WATER HEATER INSTALLATION FORM

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

RI27 CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS

Regulator Options and Accessories

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

OLI. Oil level indicator

HYDROSTATIC TEST PUMPS

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Propane Catalog Table of Contents. Integral Two-Stage Regulators. Automatic Changeover Regulators & Changeover Manifold Assemblies

Auto-belay Cable Replacement Process

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

VANGUARD A OPERATOR S MANUAL PORTER. FM-952 Rev. E 7/07

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operation Instructions Manual

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

ACCESSORIES OXYGEN-THERAPY

What to Expect From the Examination. How to Study the Plumbing Codes

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Electro-Pneumatic Bus Door Control Mechanism

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Cooktop Low-Profile Ventilation Hoods

VOYAGER 570G. 744A Sprayer Control

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

EcoSoft Water Softener. General Installation Guide

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

HC-3000 SERIES RAKE Parts Breakdown DURABILT INDUSTRIES, LLC AIRPORT ROAD POCAHONTAS ARKANSAS 72455

Cooling Capacity CFM in. w.c. (125 Pa)

Commercial Gas Water Heaters

Flygt Ball Check Valves

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

Spare Parts List Activ A 12OV Activ A 15OV Activ A 20OV Activ A 25OV

Transcription:

Recreational Vehicles Gas pressure Regulators & Accessories 2012 EDITION RE-01

Recreational vehicles Product index 1 - Introduction P.4 1.1 Pressure Gas Regulators P.4 1.2 Installations P.4 1.3 Backflow check valve safety device P.5 2 - Two Stage Range - Type 424 NRV P.6 3 - ASME Range - Type 524AS P.7 4 - Automatic Changeover Range - Type 924 NRV P.7 4.1 Start up and usage P.8 4.2 Advantages of the automatic changeover Type 924 NRV P.8 5 - Gas Accessories P.10 5.1 Vent cover Type 211 P.10 5.2 Flexible hose Type 501 LP P.10 5.3 Flexible hose Type 501 HP P.10 5.4 T-Check Type 413 P.10 5.5 Mounting brackets Type 171 P.10

Recreational Vehicles REGULATORS 3

1. INTRODUCTION Recreational vehicles 1.1 Pressure Gas Regulators Two stage gas regulators are designed and manufactured in accordance to UL 144 requirements (NFPA 1192; paragraph 5.2.15.2). Regulators are used with propane gas appliances functioning at 11 inch WC pressure. Gas pressure regulators, used in recreational vehicle (RV) installations, have two integrated stages of regulation with intermediate pressure of 10 PSI (NFPA 1192; paragraph 5.2.15.1). Depending on the kind of installation these regulators are used for, they can supply gas for a range of calorific power from 100,000 to 160,000 BTU. See technical description of gas appliances. The second stage of the regulator is equipped with a safety valve Type 1 as per UL 144. The regulator most be installed with vent hole pointing downwards to allow water to exit. (See NFPA 1192, paragraph 5.2.15.4). 100 % inspection at Re.Ca. Italy manufacturing unit of the whole range of regulators is undertaken during manufacturing process as far as: - setting pressure; see setting point at page 6 and 7 of the present catalogue; - leakage test at the inlet (high pressure value to be used) and leakage test at the outlet (low and high pressure value to be used). 1.2 Installations RV installations can be made on the basis of the following general diagram: UL 2061 UL 144 Furnace 30000 BTU Water Heater 12000 BTU Refrigerator 1500 BTU Twin Type 424NRV Inversor Type 924NRV Range 29000 BTU Outside grill 10000 BTU RV installations are supplied by single or double cylinder systems, or by ASME tanks. The integrated second stage regulator is connected to cylinders through flexible high pressure gas rubber hoses, equipped with fittings in accordance to UL 2061 (NFPA 1192; paragraph 5.2.16.4). Installations of integrated double stage regulators have to be in accordance with requirements expressed in NFPA 1192, paragraph 5.2.15. Installations generally supply the following gas appliances: - Furnace 30000 BTU - Range 29000 BTU - Water Heater 12000 BTU - Refrigerator 1500 BTU - Outside grill 10000 BTU Total 81000 BTU Inside diameter and length of pipes must be calculated to ensure that supplying pressure is sufficient to run the gas appliances at the same time. All of the above mentioned gas appliances must run at the same time without any failure. 4

Recreational vehicles Gas cylinder and regulator shall be protected by a shelter or in a cylindrical cage, see following diagram (as per NFPA 1192, paragraphs 5.2.15.6; 5.2.15.7; 5.2.15.8). Type A - Wall Installation Type B - ASME Installation 524NRV 924NRV or 424NRV + Inlet 413 501 HP 501 LP Type C - Cover Installation 501 HP 924NRV or 424NRV + Inlet 413 RV gas piping system must be tested for leakage prior to delivering vehicle to dealer network. Therefore, setting pressure test and leakage test have be done by authorized RV OEM. In case of any detected anomalies, the gas regulator kit is not likely to be responsible because the gas regulators are 100% tested while manufacturing. 1.3 Backflow check valve safety device In accordance with requirements of NFPA 1192, paragraph 5.2.16.3, it is compulsory to have a backflow check device for double cylinder installations: For Two stage group of regulation: The device consists of a T fitting that prevents gas from flowing, in case one of the inlets of the regulator kit is not connected to one of the cylinders. If a simple T fitting is used, it is obligatory to use flexible hoses equipped with backflow check device. For automatic changeover: The Backflow Check device can be integrated into the automatic changeover to prevent gas from flowing, in case one of its inlets is not connected to the cylinder. If the automatic changeover is not equipped with backflow check device, it is obligatory that the «backflow check» device be provided with flexible hoses. 5

424NRV Type Recreational vehicles 2. Two Stage Range - Type 424 NRV Cover installation Depending on the type of installation the basic model can be equipped either with a mounting bracket for wall installation, type A on page 5, or with a mounting bracket for cover installation, type C on page 5. In general plastic protection is necessary in first and second stage of regulator for all types of installations. In double cylinder installations it is necessary to couple the T inlet of the backflow check device. See Accessories at page 10. User manual is obligatory in case the regulator is directly sold to end user. RV OEM must integrate their technical documentation with the provided instruction sheet. The Two Stage regulator, Type 424 NRV, is connected to the RV through a flexible hose 501 LP Type. See Accessories at page 10. 424NRV - Two Stage UL144 First stage setting 0,3 bar Setting point 11 w.c. 60.000 BTU Wall installation Technical features: Inlet connection: 1/4 NPT Outlet connection: 3/8 NPT Test Point: 1/8 NPT Guaranteed Flow: 103000 BTU/h Setting Point: 11 WC +/- 1 at 60000 BTU Adjustable outlet pressure: from -1 WC to +2 WC Paint: metallic grey Cover and body: Zamak Alloy 13 EN 1774 Type 424NRV 1 2 Wall Model Model L Bracket Model How to order 424 NRV TYPE: Please combine the codes from the above grid together, as follows: Type + bracket model. E.g.: - 424NRV 2 6

3. ASME Range - Type 524AS 524AS Type The Two Stage Type 524 AS regulator is mounted directly to tank, connected to the tank valve of ASME container type. It is connected at its outlet to the installation gas pipe net. The regulator inlet POL coupling is equipped with an excess flow valve device. The regulator must be mounted with vent holes pointing downward. The cover 211-086 (see page 10) is normally mounted as protection for the regulator. See type C installation. Technical features: Inlet connection: POL.880 Outlet connection: 3/8 NPT Test Point: 1/8 NPT Guaranteed Flow: 103000 BTU/h Setting Point: 11 WC +/- 1 at 70000 BTU Adjustable outlet pressure: from -0.5 WC to +1.5 WC Paint: metallic grey Cover and body: Zamak Alloy 13 EN 1774 524AS - ULl144 First stage setting 0,3 bar Setting point 11 w.c. 60.000 BTU 4. Automatic Changeover Range - Type 924 NRV 924NRV Type Recreational vehicles Technical features: Inlet connection: ¼ female NPT or inverted flare Outlet connection: 3/8 NPT Guaranteed Flow: 160000 BTU/h Setting Point: 11 WC +/- 1 at 70000 BTU Inversion Pressure: 5 PSI (0.35 bar) Adjustable outlet pressure: from -0.5 WC to +1.5 WC Paint: metallic grey Cover and body: Zamak Alloy 13 EN 1774 Working temperature range: -4 F -122 F (-20 C-50 C) Depending on the type of installation the basic model can be equipped either with a mounting bracket for wall installation, type A at page 5, or with a mounting bracket for cover installation, type C at page 5. User manual is obligatory in case the regulator is directly sold to end user. The RV OEM must integrate their technical documentation with the provided instruction sheet. The automatic changeover Type 924 NRV is connected to the RV through a flexible hose 501 LP Type. See Accessories at page 10. Pout in w.c. 924NRV - Automatic Changeover not adjistable Reversal Point 5 PSI Setting Point 11 w.c. with 70.000 BTU Setting Point 7

Recreational vehicles Bracket with protective cover installation Wall mounted installation 4.1 Start up and usage How to turn it on - Make sure that the Automatic Changeover is connected to the two tank valves with high pressure gas hose. Make sure that the automatic changeover is mounted above the two tank valves. Open the two tank valves at the same time. This is fundamental to allow the automatic changeover to ensure the continuous functioning of the gas installation, in case one of the two cylinder tanks goes empty. The automatic changeover cannot namely pass to the reserve gas tank, if the tank valve is closed. Figure 1 How to read the automatic changeover indicator: full gas tank - When both gas tanks are full, the changeover indicator becomes green, provided that both tanks A and B valves are turned on. - The arrow on the hand-wheel indicates which of the two bottles is used first, this becomes the service A B bottle. The other gas cylinder is called reserve bottle. See picture 1. Service Reserve How to read the automatic changeover indicator: empty gas tank Figure 2 - When the «service bottle» exhausts, the automatic changeover gets the sense negative pressure (gas bottle pressure less than 5 PSI). And automatically switches to the reserve bottle to supply the gas installation as normal. The end user will knows that the service bottle is now empty understands such operation because the green because indicator turns red. See picture 2. How to substitute the empty gas tank with the full one A B - Turn the tank valve A off and rotate the automatic changeover hand-wheel 180 (picture 3a). If the reserve Service Reserve gas tank is full, the indicator will turn green (picture 3b). - Remove the empty gas tank (picture 3c). - Install a full gas bottle and make sure to connect the Figure 3a Figure 3b Figure 3c Figure 3d same to the automatic changeover. Then turn on the A B A B A B A B cylinder valve A (picture 3d). 4.2 Advantages of the automatic changeover Type 924 NRV Easy-to-read changeover indicator The indicator displays the two different ways of functioning Service/Reserve by changing colour. Reading the indicator colour is fundamental for the user because he is able to know when to proceed to replace the empty gas tank with the reserve gas tank. The indicator is designed to guarantee the best reading as possible: * Far away visibility * Frontal visibility * Lateral visibility Integrated Back-flow check device As the back-flow check device is integrated in the automatic changeover 924 NRV Type, the user can apply gas high pressure hoses which are not equipped with their own back-flow check device. This always provides safety installation, even if the user replaces gas rubber hoses. Automatic changeover inversion pressure value The automatic changeover has to let the service cylinder get exhausted before inverting to the reserve gas tank. The automatic changeover performs even better at low pressure. In fact the automatic changeover Type 924 NRV is designed to work with a pressure of inversion at 5 PSI (0.35 bar). This means that the inner pressure of the service gas cylinder must flow below 5 PSI to make the changeover begin to extract gas from the reserve bottle. At this pressure value we know in fact that a propane gas bottle can be considered empty, whichever capacity or temperature functioning conditions the appliance is designed for. Remote sound signal -optional only- All 924 NRV type changeovers are equipped with a magnetic component placed below the hand-wheel. Thanks to this an optional electronic sound device can be mounted on the hand-wheel, allowing the end user to hear the sound when the installation is running with the reserve gas tank. Thus the end user knows he/she has to replace the empty gas tank at the earliest. For more information please call the nearest RV dealer. Service Reserve Empty Service Empty Service Reserve Service 8

Recreational Vehicles ACCESSORIES 9

Recreational vehicles 5. ACCESSORIES 5.1 Vent cover Type 211 Model 211-184 - Protection cover on the second stage of two stage 424 NRV regulator. Model 211-161 - Protection cover for vent hole on the second stages o f t w o s t a g e 4 2 4 N R V a n d Automatic Changeover 924NRV regulators. M o d e l 2 1 1-0 8 6 - C o m p l e t e protection cover for Two Stage ASME Type 524 AS. 5.2 Flexible hose Type 501 LP 5.3 Flexible hose Type 501 HP 3/8" MNPT 1/2" SAE Flare 1/4" Inverted Flare Type 1 ACME Nut Model 501-007 3/8" I.D. hose, 3/8" MNPT x 1/2" SAE Flare Model 501-005 1/4" I.D. hose, Type 1 ACME Nut x 1/4" Inverted Flare 1/4" MNPT Type 1 ACME Nut Model 501-006 1/4" I.D. hose, Type 1 ACME Nut x 1/4" MNPT 5.4 T-Check Type 413 Model 413-007 - To be used in double cylinder installations, mounted at the inlet of Two Stage 424NRV. In installations equipped with T-Check standard flexible hoses can be used. 5.5 Mounting brackets Type 171 Model 171-059 - Wall installation manifold, designed for changeover Type 942 NRV only. Model 171-061 - Wall installation manifold for twin regulator Type 424 NRV only. Model 171-067 - Cover installation manifold for both twin regulator Type 942 NRV and changeover Type 424 NRV. 10

Cavagna North America, Inc. 50 Napoleon Court, Somerset, NJ 08873 USA Tel 732.469.2100 * Fax 731.469.3344 email: info@cavagna.com www.cavagnagroup.com Recreational Vehicles Rev.2 - Mar 12