RI27 CNG REDUCER INSTALLATION PROVISIONS & WARNINGS



Similar documents
RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Cooling system components, removing and installing

Diagram of components 2. Reducer..3

A/C refrigerant system, overview

MAKE OF AUTOMOBILE: NUMBER : 076/ DATE : Copyright Prins Autogassystemen B.V VERSION NR : B

VOYAGER 570G. 744A Sprayer Control

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Isotemp Basic, Slim/B & Slim Square

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Thermostatic valve Type AVTA

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

1998½-2007 Dodge Ram 5.9L Cummins

LNG Fuel Tank System LNG Tank overview

Assembly and instructions

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Cooling system components, removing and installing

TURBO Installation Instructions: General

REMOVAL AND INSTALLATION

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Cooling system components

SALEEN SPEEDLAB SERIES VI STANDARD SC UPGRADE KIT

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Operators manual Basic water heater

ENGINE COOLING SYSTEM

NITROUS TRANSFER PUMP INSTRUCTIONS

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

VALVES FOR REFRIGERATING SYSTEMS

XL PREMIUM OIL COOLER KIT

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

SunMaxx Solar Filling Station Operating Instructions

Cooling system components, removing and installing

Electro-Pneumatic Bus Door Control Mechanism

Hi Wall Split Air Conditioners

servo-controlled 3-WaY vacuum solenoid valves WiTH

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Reverse Cycle Inverter Split System Air Conditioner

Please keep this manual for f uture reference.

Overheating limit control

Machine needle shut-off nozzle type-a

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

BRAZED PLATE INSTALLATION MANUAL

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

Turbocharger system components, servicing

Section 7 Adjustment, Repair and Replacement

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

SELECTION, APPLICATION & MAINTENANCE

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

Bedienungsanleitung Diesel-Set 1 (Niederdruck)

Thermostatic element RAVV for 2-way valves

MAINTENANCE MANUAL LPG CNG INJECTOR RAIL RAIL TYPE 03

NFPA31FuelOilPiping 1 Revised

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

SELECTION, APPLICATION AND MAINTENANCE

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Installation and maintenance instructions

Hydraulic Trouble Shooting

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Series 510 Submersible Level Transmitters

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Workshop Compressors CLASSIC Series

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

2003 ACCORD - Automatic Transmission Removal

5800 Temperature Sensor Cable Assembly

Marine Catalogue 2013

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Shower Handbook (Also covers 650 chrome variant)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

ETC -SV. Class 0 oil-free compressed air through catalysis

Utility Distribution Systems

M A N U A L

SELECTION, APPLICATION AND MAINTENANCE

Cooling system components, removing and installing

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

SMD Rework Station TABLE OF CONTENTS

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Transcription:

RI27 CNG REDUCER INSTALLATION PROVISIONS & WARNINGS Rev.01.02 BIGAS INTERNATIONAL AUTOGAS SYSTEMS S.r.l. Via di Le Prata, 62/66-50041 Calenzano Firenze ITALY Tel. 0554211275 - Fax 0554215977 http: www.bigas.it e-mail tech@bigas.it Realizzazione: Ufficio Tecnico Bigas /2015 - ISWP013

1. DATA SHEET Type of gas CNG Model Engine maximum power Gas inlet pressure Working pressure RI27 150 KW 204 HP 260 bar 3771 PSI 2 bar (29 psi) Not Adjustable Gas inlet Fe connection for pipes M12x1 x pipe ø 6 mm Brass Gas outlet ø est 10 mm Brass Inlet / Outlet cooling liquid (*) ø est 8 mm (n 2) Brass Working temperature Electrical solenoid valve specification -40 C 120 C -40 F 248 F 12 V d.c. / 16 W Threaded hole fixing M6 x 1 mm (n 2) Overall dimension Weight 185X98X75,5 mm 1,9 Kg GENERAL INFORMATION CNG Reducer RI27 Pressure reducer with two reduction stages. The device is designed to obtain the best gas vaporization in each environmental condition. Body construction material: nickeled brass Integrated solenoid valve Approval ECE 110 ISO 15500 Water circuit suitable (*) Note: The Pressure Reducer RI27-C3 has Inlet/Outlet cooling liquid in brass with 10 mm Ø ext Pag. 2-12 Pag. 3-12

2. GENERAL DESCRIPTION 2.1 RI27 - PRESSURE REDUCER AND ACCESSORIES The RI27 pressure reducers are available in different versions. The main differences from the basic version are: gas outlet pressure values, gas Inlet/Outlet fittings, and the pressure sensor. Before the installation, take sure that the device has been supplied with all the necessary accessories provided in the package, as listed below (see pictures). ITEM Gas Outlet pressure / Flow Rate Gas Inlet Gas Outlet Picture for illustrative purpose RI27-MT 9±0.5 bar M12x1mm fe M18x1,5 mm fe Description 1 Gas inlet fitting 2 Gas outlet fitting 3 Water inlet / outlet fitting RI27-MT1 7±0.5 bar (101.5±7.2 psi) 65 Kg/h (143.3 lb/h) M12x1.5mm fe M18x1,5 mm fe 4 Vacuum union 5 Solenoid valve 6 Temperature sensor with SICMA connector 7 Threaded hole fixing 8 Pressure Relief Valve - PRV RI27-Z 9±0.5 bar M16x1,5mm Ø10 mm 9 Threaded hole for pressure gauge (Pressure gauge : not supplied) 10 Wires for solenoid valve feeding Pag. 4-12 Pag. 5-12

RI27-ZC 9±0.5 bar Ø6 mm 3. PROVISIONS & WARNINGS 3.1 Reducer installing positions RI27-W 7±0,5 bar (101.5±7.2 psi) 1/2-20 Ø8 mm Install the pressure reducer in the position of pic. 2 RI27-C3 2±0.5 bar (29.0±7.2 psi) 60 Kg/h (132.3 lb/h) Ø16 mm PIC. 2 RI27-ME RI27-IV260 8±0.5 bar (116.0±7.2 psi) 55 Kg/h (121.2 lb/h) 9±0,5 bar 5/8-20 Ø 10 mm M16x1,5mm Ø10 mm M18x1,5mm fe INCORRECT INSTALLATION Never connect the pressure reducer directly to the engine or to the engine components. Pag. 6-12 Pag. 7-12

Do not istall the pressure reducer to the bulkhead which separates the engine compartment from the vehicle. When the engine is running, verify that the pressure reducer does not hit any other device. Using the bracket provided, fix the pressure reducer by the threaded holes (7) to the car body, in order to avoid vibration to the pressure reducer. Bracket can be bent or directed as needed. Place the pressure reducer always in a lower position than the height of the cooling liquid expansion tank, in order to prevent air bubbles which may form in the water circuit. In order to facilitate possible maintenance operations on the pressure reducer, the installer has to pay attention where he places the pressure reducer in the engine compartment. 3.2 Piping connections For all kind of pipes the installer has to observe the following rules: During the vehicle running there should be no movements that generate friction and usury of the pipes with other devices of the engine compartment (i.e. against sharp edges or moving parts like drive belts). s should not be stretched, nor shall have sharp corners that could create dangerous restrictions. Carefully clean the High Pressure pipes before they are finally connected to the pressure reducer to prevent any residue getting inside it. Do not leave any rubber parts during the cutting of the pipe. The presence of residues of burrs and chips inside the pipes could compromise the correct functioning of the system. Before installing the rubber hoses is a good practice to blow compressed air inside them. Do not use for fastening pipes sealant products, such as: glues, silicones, mastic, etc... 3.3 Gas pipes Do not reverse the gas inlet with the gas outlet (only for RI27 - ZC pressure reducer) The connection pipe from pressure reducer to the filter should be as short as possible. Please refer to the system installation manual. Connect the high pressure gas copper pipe to the reducer gas inlet fitting (1) and secure it with a torque wrench for a proper tightening. Connect the rubber low-pressure gas pipe on the gas outlet connection (2) and secure it with a clamp; subsequently verify that the clamps guarantees tightness. 3.4 Water hoses Connect the rubber hose to the pressure reducer, frictioning it on the inlet/outlet water connectors (3) and secure it with clamps. While engine running, verify the clamps tightening and that no leakage is coming from water pipes. The water cooling circuit connections of the pressure reducer can be installed in series or in parallel respecting to the heating circuit of the vehicle. Please refer to the system installation manual. 3.5 Electrical wiring Connect the solenoid valve (5) to the CNG ECU using the 2 wires of the coil (10). Connect the temperature sensor with SICMA connector (6) to the gas ECU. Pag. 8-12 Pag. 9-12

3.6 Pressure gauge connection Before installing the pressure gauge inject compressed air into the opposite gas inlet fitting (1) in order to eject out possible particles present in the housing. 3.7 Maintenance plan Bigas recommends to provide a routine maintenance on the CNG RI27-J every 100,000 Kms, in order to prevent possible malfunctions and to verify its status. Bigas highlights the importance of doing a check-in and a service on the above mentioned party in order to prevent possible malfunctions not connected to the product quality. Pag. 10-12 Pag. 11-12

BIGAS INTERNATIONAL AUTOGAS SYSTEMS S.r.l. Via di Le Prata, 62/66-50041 Calenzano Firenze ITALY Tel. 0554211275 - Fax 0554215977 http: www.bigas.it e-mail tech@bigas.it Realizzazione: Ufficio Tecnico Bigas 09/2015 - ISWP013