Introduction. Section 2. Introduction 2-1



Similar documents
HOT MELT APPLICATION. ideas, technology, performances

ACCUMULATOR INSTALLATION

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

ADVANTAGES OF Tankless Adhesive Melting Systems For End-of-Line Packaging

Troubleshooting Guide for Jacks Down LED Lights

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

KNC Model 3666 Automatic Pressure Calibration System

Rules for Safe Operation

Operation Manual For NDJ-8S Digital Rotary Viscometer

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Quik Lining Systems Heater Owners Guide

Nexus FS Point of Use Installation Guide

CG PTFE Diaphragm Liquid Transfer Pump

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Chapter 2 System Basics

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED)

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Finding and Fixing Leaks

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Commercial code: 69068

Rental Services Temporary Cooling - Flexible Water Hose

Error Codes: 02F. Model: (110. = Whirlpool) S/N: CSP Type: 199-AKP 705/WT. Sears Kenmore/Whirlpool Front Load Washer

Matching the Right Hot Melt Adhesive System to Your Case/Carton Sealing and Tray Forming Operations. Published by: Nordson Corporation

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Maintaining Fire Protection Systems

Stainless Steel Single and Dual Circulation Kits

GenStore Archive Cabinet

spare parts Spare parts for 10 ton C-clamps Straightening > C-clamps > 10 ton

Big Rig Spray Systems. Waterproofing Air/Vapor Barrier Commercial Roofing Floor / Protective Coatings

Product Description Sheet RB15 200D Gantry Robot Item No

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

HP UPS R1500 Generation 3

Your safety and the safety of others are very important.

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

HEAT SIPHON ANSWERBOOK

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Cisco Redundant Power System 2300

RACKMOUNT SOLUTIONS. 1/7/2013 AcoustiQuiet /UCoustic User Guide. The AcoustiQuiet /UCoustic User Guide provides useful

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

UNITOR ULTRASONIC cleaning

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Single Zone LCD Thermostat Operating Instructions

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Scotch-Weld PUR Easy 250 Adhesive Applicator

Installation, Operating and Servicing Instructions. Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Technical data. Danfoss DHP-A

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Rotary screw compressors kw 5,5 7, , bar MODULO

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

Injector Max Machine

MODEL # Introduction

Powers Controls TH 192 S Single Temperature Room Thermostat

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Pool technologies and solutions. swimming pool update

HVAC Processes. Lecture 7

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Magnum Mobile Generator MMG55 Specifications

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Gas Oven Repair Guide

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Most agencies think about cleaning because of debris in the line.

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Vario Roof. Model R HO 04 Vario Roof (CrullG)

FANG 24T, 26T and 28T -EU

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Installation & Operation Manual for Energenics Air-Flow Optimizer

AU-110 racking guide NBXPN: 023

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

GSM Autodialer Professional GJD700 Speech & Text Autodialer

T7079A,B Solid State Remote Temperature Controllers

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

Heavy-Duty Lube and Fuel Truck Sales Tool

PARAGON ELECTRIC, INC. LIQUID LEVEL CONTROLLER USER MANUAL MODELS: LLC-I, LLC-II AND TELEMETRY OPTIONS

Spare Parts List M96A.24SM/B M96A.28SM/B

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Technical Update TAA.TU Rev. 1

VAC 50/60Hz Power Adapter

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

123 Industrial Loop Road Paynesville, MN Phone:

Medical Vacuum Systems-PXMI

Transcription:

2-1 Section 2 This manual describes the installation and use of the DuraBlue 4 L (D4L), DuraBlue 10 L (D10L), and DuraBlue 16 L (D16L) adhesive melters. When necessary, the reader is referred to the documentation supplied with other Nordson products or products supplied by third parties. With the exception of tank capacity, hose/gun capacity, and exterior appearance, all DuraBlue melters are function identically. To simplify the presentation of information in this manual, depictions of the model D16L are used generically throughout this manual to represent all DuraBlue melters. 2010 Nordson Corporation

2-2 Other Sources of Information Refer to the following additional resources for quick-reference information, technical support, and information about getting the most out of your DuraBlue melter. Installation Guide The installation guide shipped with the melter provides a visual quick-reference for installing the melter. User s Guide The user s guide shipped with the melter provides a visual quick-reference to the most common operator-level tasks. The guide is appropriately sized and laminated so that it can be kept with the melter on the production floor. Product Resource CD The resource CD, which is stored in the back of this manual, contains an electronic version of this manual, parts information, and other useful resources that are designed to assist you with using and servicing your melter. 2010 Nordson Corporation

2-3 Product Description See Figure 2-1. Nordson DuraBlue adhesive melters are used in conjunction with Nordson hot melt hoses and guns to create a hot melt application system. The melter liquifies solid-form hot melt and maintains the hot melt at the desired temperature. When the guns are activated, the melter pumps the liquified hot melt through the hoses and out the gun nozzles, where it is commonly applied to the surface of a product. 1 2 Figure 2-1 System components 1. DuraBlue melter 2. Hot melt hose 3 3. Hot melt handgun 2010 Nordson Corporation

2-4 Intended Use Limitations of Use Modes of Operation DuraBlue melters are specifically designed to: Melt and pump solid-form hot melt materials that are engineered to be liquified and extruded at temperatures below 230 C (450 F) for 240 VAC melters or below 200 C (400 F) for 120 VAC melters Be used with compatible hot melt hoses and guns that are manufactured by Nordson Corporation Be used in non-explosive environments Use DuraBlue melters only for the purpose for which they are designed. DuraBlue melters should not be used: to melt or pump polyurethane reactive hot melt materials or any other material that creates a health or safety hazard when heated in environments that will require the melter to be cleaned using a water wash or spray DuraBlue melters operate in the following modes: Automatic scan The melter automatically checks and displays the current temperature of the tank, hoses, and guns to confirm that they are within their pre-defined temperature range. By default, the melter is always in the automatic scan mode unless it is placed into another operating mode. Standby The temperatures of the tank, hoses, and guns are reduced down from their operating temperature (hereafter referred to as setpoint temperature) by a pre-set number of degrees. Setup The setup mode is used to configure melter control options and features and to review stored operating data. To prevent unauthorized changes to the melter s configuration, the melter can be password-protected. Fault The melter alerts the operator when an abnormal event occurs. 2010 Nordson Corporation

2-5 Melter Identification See Figure 2-2. You will need the model and part number of your melter when requesting service or ordering spare parts and optional equipment. The model and part number are indicated on the equipment identification plate that is located on the front of the melter. Figure 2-2 Equipment identification plate 2010 Nordson Corporation

2-6 Key Components Figure 2-3 provides the name and the location of key melter components. 3 2 5 1 4 6 7 8 11 9 13 Figure 2-3 Key components 1. Electrical enclosure door 2. Control panel (see Figure 2-4) 3. Tank lid 4. Side panels 12 5. Tank 6. Hose/gun receptacles 7. Tank isolation valve (D10/D16 only) 8. Manifold 10 9. Pressure control valve 10. Filter 11. Pump 12. Mounting bracket 13. Motor 2010 Nordson Corporation

2-7 Key Components (contd) 2 1 3 4 0.201 7 5 Figure 2-4 Control panel 1. Fault LED 2. Ready LED 3. Component keys/leds 6 4. Control switch 5. Right display and scroll keys 6. Left display and scroll key 7. Function keys 2010 Nordson Corporation

2-8 Optional Equipment Optional equipment may be ordered to expand the functionality of DuraBlue melters, including, but not limited to, the following: Communications cards that allow the melter to communicate with other process equipment or a controller using standard network protocols. Automatic pressure control that allows the melter to automatically adjust adhesive output based on production requirements. Pressure gauge that provides a manifold hydraulic pressure reading. Footswitch that allows manual pump activation. Air control kit that controls the module-actuating air for a manual manifold-mounted gun or a manual spray gun. Handgun hanger that provides a convenient and safe method for storing a handgun that is not in use. Pressure control valve knob that replaces the hex screw pressure adjustment with a hand knob. Refer to Section 7, Parts, for a complete list of optional equipment. 2010 Nordson Corporation