146-1977. Looking For A High Power, Low Profile Power Supply? KEPCO. Has More Than One Way To Help Make Your Decision Easier! AN ISO 9001 COMPANY



Similar documents
DCS Series 1 kw, 1.2 kw, & 3 kw

1.44 kw Programmable DC Power Supplies XLN Series

High Power Programmable DC Power Supplies PVS Series

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Multi-Range Programmable DC Power Supplies 9115 Series

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

Power Supplies 3. SDN-P DIN Rail Series

SL Series AC and DC Electronic Loads

KONSTANTER SPL / SPL Programmable Electronic Load

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent E3633A and E3634A DC Power Supplies

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

DC Electronic Loads 8500 series

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

650W Single Output Power Supply

Considerations When Specifying a DC Power Supply

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Thyristor-controlled power supplies and battery chargers

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Programmable Power Supplies

MODEL 1211 CURRENT PREAMPLEFIER

User manual Rev. 1.2 (17/04/2015)

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Single Output Switching Power Supply

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Low and High Voltage Power Supplies

Instruction Manual. This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E E 50-20E E

ST Series POWER SUPPLIES USER INSTRUCTIONS

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

DC POWER SUPPLY ALIMENTATION C.C.

Watts SHP Series

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Uninterruptible Power Supply

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Mobile Communications DC Sources W

Agilent 87421A/87422A Power Supply

55K SERIES 28 Vin DC/DC Converter 75 Watt Single & Triple Outputs

Agilent E3633A and E3634A DC Power Supplies

Power Meter Series 700

Chassis, Power Supply, and Element Management

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Research RF Sputtering Packages

AC-DC Single Output Power Module

APD / Outputs 19" DC/DC Converter, 50 Watt

DP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.

I STAR COMPUTER CO., LTD

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

MLC TM Maximum Productivity and Versatility for Control without Compromise!

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

Voltage Regulator SPAU 341 C. Product Guide

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

7-41 POWER FACTOR CORRECTION

DS 600. A contact free flux gate based current measurement sensor 600A rms

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Quick Connect. quick - simple - efficient.

Specification of 5 Wire Analog Touch Panel

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

R&S ZNBT8 Vector Network Analyzer Specifications

Model #: SMART2200CRMXL

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

BITMAIN. APW PSU Series User Guide

Physical Specifications (Custom design available.)

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

XHR 1000 Watt Series Programmable DC Power Supply

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

Antec TruePower User's Manual

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

UMEC International Corporation

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Datasheet. Arrant-Light Oy. 120W DR Series

Telephone- and leased line modem for industrial applications TD-36

E-STOP relays, safety gate monitors

Maximum Input Current Vin=18V, 100% Load A

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CompactLogix Power Supplies Specifications

Transcription:

Looking For A High Power, Low Profile Power Supply? 146-1977 KEPCO Has More Than One Way To Help Make Your Decision Easier! AN ISO 9001 COMPANY

KLP MODEL TABLE MODEL (3) KLP 10-150 KLP 20-120 KLP 36-60 KLP 75-33 KLP 150-16 KLP 300-8 KLP 600-4 (1) 0-10V 0-20V 0-36V 0-75V 0-150V 0-300V 0-600V FOR 120A@10V 60A@20V 33.3A@36V 16A@75V 8A@150V 4A@300V 2A@600V MINIMUM PROGRAMMABLE 1.9A 1.5A 0.8A 0.4A 0.2A 0.1A 0.05A (1) 0-150A 0-120A 0-60A 0-33.3A 0-16A 0-8A 0-4A FOR 8V@150A 10V@120A 20V@60A 36V@33.3A 75V@16A 150V@8A 300V@4A RIPPLE AND NOISE (2) p-p 125 mv 150 mv 150 mv (1) The maximum current and voltage are constrained by the 1200 watt power limitation. (2) Bandwidth: 20MHz; low frequency ripple may be higher at loads less than 30 Watts. (3) Standard models (no suffix) include built-in GPIB and RS-232 interfaces. E-series models (Suffix E) include built-in GPIB and LAN interfaces. EFFICIENCY @ 115V a-c 80% 82% 83% 84% 86% 87% 88% KEPCO SERIES KLP Using high-frequency switch-mode topology for high efficiency and small size, the KLP provides 1200 watts of well-regulated, controllable d-c power in a 1U (1.75 inch high) by 19 inch rack-mountable package. KLP replaces the need for multiple power supplies by expanding the operating region. The breakthrough of a hyperbolic power limit delivers a full 1200 Watts over an expanded operating range, not just the conventional rectangular operating area. www.kepcopower.com/klp.htm VOLTS 75 36 V ADDITIONAL OPERATING REGION CONVENTIONAL POWER SUPPLY S POWER POINT A CONVENTIONAL OPERATING REGION B ADDITIONAL OPERATING REGION KEPCO KLP S 1200 WATT EXTENDED POWER A THRU C C 0 16 33 AMPERES I KEPCO SERIES KLR Kepco introduces Series KLR, offering 2400 Watts of stable, controllable d-c power in the industry standard 1U package. Five models from 20 Volts to 300 Volts are available with a conventional rectangular operating area. Input is 180-264V a-c, single phase. GPIB, RS232 and isolated analog programming are all standard. www.kepcopower.com/klr.htm KLR MODEL TABLE MODEL (1) MINIMUM PROGRAMMABLE RIPPLE AND NOISE (2) p-p EFFICIENCY @ 230V a-c KLR 20-120 0-20V 1.5A 0-120A 100 mv 87% KLR 40-60 0-40V 0.8A 0-60A 80 mv 88% KLR 75-32 0-75V 0.4A 0-32A 80 mv 87% KLR 150-16 0-150V 0.2A 0-16A 100 mv 88% KLR 300-8 0-300V 0.1A 0-8A 150 mv 89% (1) Standard models (no suffix) include built-in GPIB and RS-232 interfaces. E-series models (Suffix E) include built-in GPIB and LAN interfaces. (2) Bandwidth: 20MHz; low frequency ripple may be higher at loads less than 30 Watts. KEPCO, INC. 131-38 Sanford Avenue Flushing, NY 11355 USA Tel: (718) 461-7000 Fax: (718) 767-1102 Data subject to change without notice. 2013 KEPCO, INC. Litho in USA

FEATURES KLP: Provides 1200W output power over a hyperbolic output power envelope, resulting in full output power availability over the range of 8V, 150A to 600V, 2A KLR: Provides up to 2400W output power via a conventional rectangular output power envelope, resulting in full output power at model limits only Switch mode topology for cool, efficient operation GPIB and isolated analog programming included on all models Standard models have an RS-232 interface E-Series models replace the RS-232 interface with an Ethernet (RJ-45) connector supporting LAN (LXI certified for KLP) KLP: 1U panel height at 1200 watts KLR: 1U panel height at 2400 watts Front to back air flow allows full power operation without spacers between supplies KLP: Operates over universal a-c mains voltage range of 90-264V a-c with PFC KLR: Operates over a-c mains voltage range of 180-264V a-c with PFC KLP: Stud-style output power terminals for LV models (10V, 20V, 36V), and Euroblock output power terminals for HV models (75V, 150V, 300V, 600V) KLR: Stud-style output power terminals for LV models (20V, 40V), and Euroblock output power terminals for HV models (75V, 150V, 300V) MARKETS AND APPLICATIONS Aerospace and Satellite Test Telecom and IT Industry Automated Test Equipment Factory Automation QC Testing Burn-in Solar Water Purification Thermal Process Control Chemical Processing Semiconductor Manufacturing Battery Charging and Testing Electroplating, Sputtering and Coating New Energy R&D KLP/KLR INPUT SPECIFICATIONS SERIES KLP SERIES KLR a-c Nominal 100-240V a-c 200-240V a-c Single phase Range 90-265V a-c 180-265V a-c Wide range Input Nominal Range 50-60 Hz 50-60 Hz Frequency Maximum 45-440 Hz 45-440 Hz Increased leakage above 66 Hz Power Factor (PF) Typical 0.99 0.99 Meets EN 61000-3-2 Maximum 120V a-c 13A rms N/A Rated load (1200W) Input 240V a-c 6.5A rms N/A Rated load (1200W) 230V a-c N/A 12A rms Rated load (2400W) Inrush 265V a-c 40A 40A Peak 132V a-c 20A N/A Peak Input Fusing Circuit breaker Circuit breaker 2-line Low a-c Protection 87V a-c self protected 175V a-c self protected User-selectable recovery (1) Output Holdup Typical 10 milliseconds 5 milliseconds Ride through Leakage 115V a-c, 60 Hz 1.2mA max N/A 230V a-c, 50 Hz 2.3mA max 2.3mA max (1) Either PROTECTED (output disabled and locked until source power recycled) or SAFE (output disabled with unit programmed to last setting; power recycling not needed for recovery) or AUTO (when fault clears, unit automatically recovers to programming setpoints and output state (enabled/disabled) as before fault was detected. NOTE: Contact Kepco Applications Engineering for d-c input. KEPCO, INC. 131-38 Sanford Avenue Flushing, NY 11355 USA Tel: (718) 461-7000 Fax: (718) 767-1102

KLP/KLR OUTPUT CHARACTERISTICS KLP/KLR GENERAL SPECIFICATIONS Stabilizer Type CV/CC / Adjustment Range 0-100% of rated voltage min-100% of rated current (1) No minimum load required Source Effect 0.01% Emax Over full 0.01% lmax source range Load Effect 0.02% Emax Over full 0.05% lmax Temperature Effect Time Effect (drift) 0.01%/ºC 0.01%/ºC 0.02%/24hr 0.02%/24hr 0-50ºC After 30 minute warmup Error Sensing 0.25 volts per wire Above rated output Isolation Transient Recovery for Load Change Turnon/turnoff Overshoot Rise Time Fall Time Overvoltage Protection Overcurrent Protection Output Load Wire Protection Excursion Recovery Parallel Operation No Load (2) Rated Load 10-40V: 100V d-c or peak 75-600V: 600V d-c or peak 1% of Emax 50% load step 2A/ microsecond max 2 msec 10% min load, Return to 0.1% of setting 2% max 10V: 475 msec 20V: 525 msec 36V: 825 msec 40V: 975 msec 75V: 2820 msec 150V: 4850 msec 300V: 4400 msec 600V: 3150 msec Programmable 20-120% of Emax Programmable 72-120% of Imax Shutdown Active load sharing within 5% of I0 rated Either output terminal to ground Rated output, any load 0-Emax 0-Imax Emax-0, no load (open circuit) Emax-0 Imax-0 User selectable recovery (3) User selectable recovery (3) User selectable recovery (3) Up to 5 units maximum (4) (1) See Model Table for minimum programmable current. (2) For improved fall time performance consult factory for "R" (Rapid Output Discharge) option. (3) Either PROTECTED (output disabled and locked until source power recycled) or SAFE (output disabled with unit programmed to last setting; power recycling not needed for recovery). (4) E-series are not Master/Slave capable. KEPCO, INC. 131-38 Sanford Avenue Flushing, NY 11355 USA Tel: (718) 461-7000 Fax: (718) 767-1102 Temperature Operating -10 to +50 C Rated load +50 to +70 C Derate current 3% per C over 50 C Storage -40 to +85 C Cooling 3 internal d-c fans Exhaust to the rear Humidity 10 to 90% RH Non-condensing Shock 20g, 11msec ± 50% Non-operating half sine Vibration 5-10Hz 10mm double amplitude 3-axes, non-operating 10-55 Hz 2g 3-axes, non-operating Altitude sea level to 10,000 ft. 0-3,000 ft: 100%, linear derating to 70% of power at 10,000 ft. Loss of Shutdown User selectable Source Power recovery (1) Overtemperature Shutdown User selectable Protection recovery (1) Fan Failure Shutdown Recovery requires power recycling Withstand Input- 2121V d-c 25 C, 65% RH Chassis (all models) Output- Chassis Input- Output 1250V d-c (10V-40V models) 2121V d-c (75V-600V models) 2500V d-c (10V-40V models) 4242V d-c (75V-600V models) (1) Either PROTECTED (output disabled and locked until source power recycled) or SAFE (output disabled with unit programmed to last setting; power recycling not needed for recovery) or AUTO (when fault clears, unit automatically recovers to programming setpoints and output state (enabled/disabled) as before fault was detected. KLP/KLR PHYSICAL SPECIFICATIONS Weight English 15 lbs Shipping: 20 lbs Metric 6.82 Kg Shipping: 9.07 Kg Dimensions English 19" x 1.735" x 17.5" Depth excluding W x H x D connectors and Metric 482.6mm x 44.45mm terminal blocks x 443.7mm Source Power IEC 320-C19 250V a-c, Connector appliance inlet 16A (VDE) 125V a-c, 20A (UL) Load 10-40V Nickel-plated copper Provision for Connections models busbar with integral safety covers threaded stud (1/4-20-1/2in.) 75-600V Shock-safe Euroblock, models single conductor size: 20-10 AWG (0,5-5,0 mm 2 ) Analog 15 pin D-sub Programming Port Digital Primary Standard GPIB IEEE 488.2 (GPIB) Programming connector Ports Secondary 9 pin D-sub RS 232 (standard models only) Secondary RJ45 LAN (E-Series models only) Feedback/ 5 position low profile Control Input Euroblocks

KLP/KLR PROGRAMMING CHARACTERISTICS - LOCAL Local Control Rotary encoders Panel mounted Local Control Coarse ~100 LSB/step Depress control for fine resolution Resolution Fine 1 LSB/step Setting Range 0-100% of rating KLP will automatically adjust limit to maintain 1200W maximum Power Up Defaults to zero Last setpoint values may be saved for voltage and current Settings Defaults to min value prior to unit shutdown, and recall them when unit is next turned on Protection Overvoltage 20-120% of E max Programmable; accessed via front panel Limits Overcurrent 72-120% of I max protect switch or SCPI command over digital bus KLP/KLR PROGRAMMING CHARACTERISTICS - DIGITAL Supported Standard GPIB and RS 232 Supports SCPI command set for Interfaces Models GPIB and RS 232 E-Series GPIB and LAN Support SCPI command set for Models Support four interfaces for LAN: GPIB and LAN Web interface, port 80 SCPI Telnet, port 5024 SCPI Sockets, port 5025 VXI 11, port 1024 GPIB GPIB address range: 1 to 30 Factory default is 6 RS 232 Standard Baud rate range: 2400, 4800, Factory default is 38,400 Models Only 9600, 19,200 or 38,400 Digital Remote Isolation Safety Extra Low (SELV) Control Format Compatible with SCPI protocols W98 SE and later operating systems Programming Resolution Programming Accuracy Readback Resolution Readback Accuracy Status Reporting 0.024% of E max and I max 0.05% of E max and I max 0.024% of E max and I max 0.1% of E max and I max OVP, OCP, OTP, Output Lead Fault (OLF), fan failure, source power loss KLP/KLR PROGRAMMING CHARACTERISTICS - ANALOG Analog Remote Selection Activate with jumper at analog Recognized during power up Control programming connector Isolation Safety Extra Low (SELV) Analog Input 2Hz (0.5 Second) applies to programming by Analog input voltage digitized (12-bit resolution), optically Update Rate voltage/resistance and readback specifications isolated, then processed by digital section Programming 0-10V equivalent to Full Scale By can be reduced by the user 0-10V See Model Table for minimum programmable current. equivalent to Full Scale can be reduced by the user Programming 0-10K ohms Resistance equivalent to Full Scale By Resistance can be reduced by the user 0-10K ohms See Model Table for minimum programmable current. Resistance equivalent to Full Scale can be reduced by the user Readback 0-10V proportional signal Proportional to analog control voltage/resistance Remote inhibit TTL compatible Dual polarity, can be active (inhibit the output) for either a TTL high or low Composite Status Flag Isolated form C contacts Programmable. Flags system fault. Additional user selectable flag: a) transition from CV to CC mode or b) transition from CC to CV mode.

RODC Rapid Output Discharge Circuit Option The Rapid Output Discharge Circuit (RODC) option (suffix R) is available on all KLP/KLR models. This circuit rapidly discharges the output capacitance, thus significantly reducing response time to reductions in output voltage. The circuit consists of a voltage detector that compares the programmed and actual values of output voltage. The discharge circuit is activated only when the actual voltage exceeds the programmed value. Without the RODC circuit, discharge of the total output capacitance (internal and external) is achieved through a combination of the external load resistance and an internal current sink. For high load resistance or open circuit conditions at the output, response time (fall time) can vary from hundreds of milliseconds to seconds depending upon the magnitude of the high-to-low voltage transition. With the RODC option, output fall time is reduced to approximately the same value as rise time, even with external capacitance equal to 50% of the nominal internal output capacitance. Please see the website for details about this option. Visit www.kepcopower.com/klp.htm and www.kepcopower.com/klr.htm for more information Looking For More High Power, Low Profile Power Supplies? SERIES KLN The Kepco Series KLN is a new family of automatic crossover, low-profile, high-performance, low-cost programmable power supplies. The KLN Series offers stable d-c power in a 1U high, half-rack package for 750W, a 1U high, full-rack package for 1500W and a 2U high, full-rack package for 3000W. A total of 39 voltage-current combinations are offered. Output voltages range from 0-6 Volts to 0-600 Volts and output currents range from 0-400 Amps down to 0-1.25 Amps. Speed-controlled fans limit acoustic noise for bench-top applications when full power is not needed. Precise programming of voltage, current and their limits may be achieved from the front panel, or by analog means or by RS 485 digital control. GPIB or LAN interfaces are factory-installed options. KLN Series Programmable Power Supply: 750W 1U, Half-Rack (top), 1500W 1U, Full Rack (middle), 3000W 2U, Full Rack (bottom) For more information visit www.kepcopower.com/kln.htm KEPCO, INC. 131-38 Sanford Avenue Flushing, NY 11355 USA Tel: (718) 461-7000 Fax: (718) 767-1102