Hydraulic Flow Control Valves



Similar documents
Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Unit 24: Applications of Pneumatics and Hydraulics

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Check Valves Valve locator

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Flow divider (flow distributor), type TQ

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

Example. Fluid Power. Circuits

PUMP AND MOTOR DIVISION

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

PART 2 FORKLIFT HYDRAULIC SYSTEM

Waste Oil Handling, Spill Containment & Lighting

3/2- and 2/2-way cartridge valve type BVE

COUNTERBALANCE VALVES

Chapter 5: Flow Valves

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Line rupture protection valves type LB

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

2/2 and 3/2 Way Size 6 Seat Valves

Pressure reducing valve, direct operated, Type ZDR 6 D

Pressure Relief and Regulating Valves

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Hydraulic Control Solutions

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Control block EDD Modular Directional Valve

Variable Displacement Pump AA10VSO

Pressure Relief Valves SPV, SPVF

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Series PVP Variable Volume Piston Pumps

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

ROTARY GEAR FLOW DIVIDERS

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Quiz On Information Learned From Chapter 1

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Data sheet ECC 12 and 22

15/40/80CN Series Medium Pressure Filters

Pressure relief valves Size 6

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

LOADER DIRECTIONAL CONTROL VALVE LV LV22RFSTKLB SHOWN T

Master Catalogue I August 2011

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Heating, air-conditioning, cooling

Proportional pressure regulators VPPE

Series TMM Axial Piston Motor. Technical Information

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

VOYAGER 570G. 744A Sprayer Control

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Chapter 6: Check Valves

V47 Series Temperature Actuated Modulating Water Valves

SOLENOID VALVES AND PNEUMATIC VALVES

The Secret of Hydraulic Schematics. BTPHydraulics

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Valve systems Base plates, according to standard ISO Brochure

SIMPLIFIED VALVE CIRCUIT GUIDE

Electro-hydraulic pressure switches type DG

OCTOPUS SELECTION & INSTALLATION GUIDE

Control blocks for two-hand start ZSB

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

MANTA Piston Distributor for Oil and Fluid Grease

2-way flow control valve Type 2FRM 6

Joystick PVRES and PVREL. Technical Information

PVH131/141 Variable Displacement Piston Pump - 11 Design

Directional Control Valve Equipment for Front End Loaders

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Valves. Sub-Base Mounted Valves to ISO 5599/2

Directional seated valves type VP 1

Vickers. Piston Pumps

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Open center control block in monoblock design MO-40

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

Electro-Pneumatic Bus Door Control Mechanism

Transcription:

Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range

CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series Variable Flow Pressure Compensated Control Valve 3 WPD Series Fixed Priority Flow Dividers 5 RFC Series Adjustable Throttle Valve 7 FV 120 Series Fixed Priority Flow Dividers 9 FV 126 Series Fixed Priority Flow Dividers 11 FV 200 Series Proportional Flow Dividers 13 VFD 50 Series Variable Priority Flow Dividers 15 2FV2V Series Variable Priority Flow Dividers 17 Continued over page

CONTENTS Continued from previous page DESCRIPTION PAGE No. 2FV2V Series Variable Priority Flow Divider with Motor Drive 21 FDM Series Variable Priority Flow Divider with Remote Proportional Control 23 2FV2V Series Manifold Mounted Variable Priority Flow Divider 25 MM80 Series Manifold Mounted Variable Priority Flow Divider 27 FVDVRV Series Variable Priority Flow Divider with Diverter Valve 29 FDC 60 Series Flow Divider Combiner 31

ILFC Series Fixed Flow Pressure Compensated Control Valve FLOW CONTROL VA LVES maintain the flow rate of hydraulic fluid to a specified value. Applications include hydraulic cylinders required to extend or retract at constant speeds and hydraulic motors required to rotate at constant speeds. When used with a fixed delivery pump the excess flow is bypassed across a relief valve. Specifications Maximum Pressure: 210 bar (working) Features Pressure compensated to ensure a constant flow rate under varying pressures. Pre-set in factory to customer requirements at any flow rate between 1.5 lpm - 16 lpm. Uncontrolled flow is permitted in reverse direction. Chemically blacked finished. Maximum Flow: 16 lpm Porting: BSP & NPT - see Table 1 Material: Exterior parts; Chemically blacked steel Interior parts; steel spool in aluminium sleeve Weight: see Table 1 Symbol 1

ORDERING CODES Typical Code ILFC 16 5 J ILFC - In-line (fixed) Flow Control Flow Size (see Table 1) Factory Preset Flow Rating in lpm Port Thread (see Table 2) Table 1: Dimensions Code Flow Range Port A B C A/F Weight kg Size Thread 14 1.5-14 lpm 1 / 4 BSP 64 57 25 22 0.20 16 1.5-16 lpm 3 / 8 BSP 77 57 25 22 0.20 16 1.5-16 lpm 3 / 8 NPT 77 57 25 22 0.20 Table 2 Code J A Thread BSP NPT INSTALLATION DETAILS Dimensions in millimetres A C A/F B Uncontrolled Flow Controlled Flow Section View * Other threads available to special order. 2

VFC Series Variable Flow Pressure Compensated Control Valve VARIABLE FLOW CONTROL VA LV E S maintain the flow rate of hydraulic fluid to a selected value. Applications include hydraulic cylinders requiring constant extension or retraction speeds and hydraulic motors requiring constant rotational speeds. When used with a fixed delivery pump the excess flow is bypassed across a relief valve. Specifications Maximum Pressure: 210 bar (working) Maximum Flow: 55 lpm Features Pressure compensated to ensure a constant flow rate under varying pressures. Knurled knob enables fast, accurate adjustment of flow rate in one direction (under pressure) from 1.5 lpm to 55 lpm. Knurled knob can be locked in position by a grub (set) screw and provides weatherproof sealing to prevent the adjusting screw from corroding or seizing. Free (uncontrolled) flow is permitted in reverse direction. Porting: BSP & NPT (see Table 1) Material: steel components in an aluminium body Weight: see Table 1 Symbol 3

ORDERING CODES Typical Code VFC 20 K J VFC - Variable Flow Control Flow Size (Table 1) Adjustment Method (knurled knob) Porting (Table 2) Table 1: Dimensions Code Flow Range Porting A B C D E F H Weight (lpm) Size Thread (kg) 20 1.5-20 1 / 4 BSP 59.9 17.5 32.8 25.4 44.4 84.8 28.4 0.2 40 2.0-40 3 / 8 BSP 74.6 23.8 43.9 35.1 57.1 107.1 38.1 0.4 55 2.0-55 1 / 2 BSP 77.7 23.8 47.5 38.1 63.5 119.1 41.1 0.5 20 1.5-20 1 / 4 NPT 59.9 17.5 32.8 25.4 44.4 84.8 28.4 0.2 40 2.0-40 3 / 8 NPT 74.6 23.8 43.9 35.1 57.1 107.1 38.1 0.4 55 2.0-55 1 / 2 NPT 77.7 23.8 47.5 38.1 63.5 119.1 41.1 0.5 Table 2 Code J A Thread BSP NPT INSTALLATION DETAILS Dimensions in millimetres B Knurled Knob Adjustment Locking Screw E A H D C Controlled Flow F Free Flow * Other threads available to special order. 4

WPD Series Fixed Priority Flow Dividers P R I O R I T Y TYPE FLOW DIVIDERS split a single input flow into a Priority (regulated) flow and a By- Pass (excess) flow which can be returned directly to the oil reservoir or used to power a second system. This often dispenses with the need for another pump to operate a second system. A typical application on mobile machinery is to use the P r i o r i t y (regulated) flow for power steering and the B y - P a s s (excess) flow for an implement or lift circuit. This ensures the power steering is satisfied first to keep the steering speed constant. Specifications Maximum Pressure: 140 bar Features P r i o r i t y flow rate is pre-set in factory. Flow through the Priority port will remain constant at the pre-set value as long as input flow equals or exceeds the Priority flow value. Pressure compensated permitting both Priority and By-Pass flows to be used simultaneously at varying pressures without affecting the Priority flow rate. Built-in pressure relief valve protects the Priority circuit from excess pressure. Total Flow Capacity: 113 lpm Regulated Flow Capacity: See Table 1 Porting: Inlet and By-Pass 3/4 BSP Priority and Relief 3/8 BSP Material: Steel components in Cast Iron Body Symbol P T BP R 5

ORDERING CODES Typical Code WPD 45 69 Series Priority Flow (Table 1) Relief Valve Pressure in bar (Table 2) Table 1: Priority Flow Code Priority Flow 05 2.3 lpm 10 4.5 lpm 17 7.73 lpm 20 9.1 lpm 30 13.6 lpm 35 15.9 lpm 40 18.2 lpm 45 20.5 lpm Table 2: R/V Settings Settings Flow Code 62 bar 30 17 69 bar 30 35 45 05 10 103 bar 20 30 40 INSTALLATION DETAILS Dimensions in millimetres 22 Relief Valve 3 / 8 BSP Port 3 / 4 BSP Inlet Port 3 / 4 BSP Secondary Port 3 / 8 BSP Priority Port 32 48 CRS 2 Mounting Holes, 7 dia. 26 130 6

RFC Series Adjustable Throttle Valve THROTTLE VA LV E S provide fine adjustment of flow rates and are particularly useful when accurate metering is required at low flow. Because these valves are not pressure compensated they should be used in systems where pressure fluctuations are minimal. Specifications Maximum Pressure: 320 bar (working) Maximum Flow: 120 lpm Features Neat in-line mounting. Fine adjustment at low flow rates is easily accomplished by rotating the valve body with respect to the valve stem. Models are available giving either restricted flow in both directions or restricted flow in one direction with full flow in reverse. Chemically blacked finish. Porting: see Table 2 Material: chemically blacked steel ( free reverse flow valve includes an aluminium poppet) Weight: see Table 2 Symbol Including by-pass check (Type I ) Without by-pass check (Type W ) 7

ORDERING CODES Typical Code RFC 30 W RFC - Rotary Adjustment Flow Control Flow Size (Table 2) Reverse Flow Condition (Table 1) Table 1: Reverse Flow Control Code I W Description Including by-pass Check Without by-pass Check 120 100 80 60 50 40 30 20 10 0 0 Throttle Characteristics at 7 bar 2.5 2.75 3 3.25 3.5 3.75 4 120 50 30 18 Setting (No. of turns) INSTALLATION DETAILS Dimensions in millimetres B Port Thread see Order Code C D A Table 2 Code Flow Size Porting (BSP) A B C D Weight kg 18 18 lpm 1 / 4 19 32 34 65 0.28 30 30 lpm 3 / 8 22 41 43 75 0.53 50 50 lpm 1 / 2 27 46 48 80 0.69 120 120 lpm 3 / 4 32 55 58 100 1.15 8

FV 120 Series Fixed Priority Flow Dividers P R I O R I T Y TYPE FLOW DIVIDERS split a single input flow into a Priority (regulated) flow and a By-Pass (excess) flow which can be returned directly to the oil reservoir or used to power a second system. This often dispenses with the need for another pump to operate a second system. A common application on mobile machinery is to use the Priority (regulated) flow for power steering and the B y - P a s s (excess) flow for an implement or lift circuit. This ensures the power steering is satisfied first to keep the steering speed constant. Specifications Maximum Pressure: 210 bar (working) Total Flow Capacity: 76 lpm Regulated Flow Capacity: see Table 1, ordering codes Porting: see Table 3, ordering codes Material: steel components in cast iron body Weight: 1.50 kg Mounting: two bolt Relief Valve: see Table 2, ordering code Features P r i o r i t y flow rate is pre-set in factory to customer specifications at any value between 3.78 lpm and 34.1 lpm in increments of 3.78 lpm. Flow through the Priority port will remain constant at the preset value as long as input flow equals or exceeds the Priority flow value. Pressure compensated permitting both Priority and By-Pass flows to be used simultaneously at varying pressures without effecting the Priority flow rate. Built-in pressure relief valve protects the Priority circuit from excess pressure and is adjustable from 34.5 bar to 210 bar (Factory set 82.7 bar unless otherwise specified). Can be used as unidirectional two port in-line flo w control by plugging the By-Pass flow port (NB: In this configuration a relief valve must be used on the inlet line). Symbol P T BP R 9

ORDERING CODES Typical Code FV 2 1 20 J FV - Valve Type Priority Flow Setting (Table 1) Relief Valve (Table 2) 20 - Basic Type Porting (Table 3) Table 1: Priority Flow Code Flow at Priority Port 1 3.78 lpm 2 7.57 lpm 3 11.4 lpm 4 15.1 lpm 5 18.9 lpm 6 22.7 lpm 7 26.5 lpm 8 30.3 lpm 9 34.1 lpm Table 2: Relief Valve Code Description 0 Without Relief Valve 1 With Relief Valve Table 3: Porting Code Inlet and By-Pass Port Priority and Relief Port J 1 / 2 BSP 3 / 8 BSP G 7 / 8-14 SAE 9 / 16-18 SAE Note: Relief Valve can be adjusted between 34.5 bar and 210 bar. Please specify required setting when ordering otherwise setting will be 82.7 bar. INSTALLATION DETAILS Dimensions in millimetres 48.8 2 Mtg Holes Ø7.1 Thru By-Pass Port Inlet Port Priority Port 19.8 49.5 96.8 30.2 Relief Valve Drain Port * Other threads available to special order. 10

FV 126 Series Fixed Priority Flow Dividers P R I O R I T Y TYPE FLOW DIVIDERS split a single input flow into a Priority (regulated) flow and a By-Pass (excess) flow which can be returned directly to the oil reservoir or used to power a second system. This often dispenses with the need for another pump to operate a second system. A common application on mobile machinery is to use the Priority (regulated) flow for power steering and the B y - P a s s (excess) flow for an implement or lift circuit. This ensures the power steering is satisfied first to keep the steering speed constant. Specifications Maximum Pressure: 172 bar (working) Total Flow Capacity: 227 lpm Regulated Flow Capacity: see Table 1, ordering codes Porting: see Table 3, ordering codes Material: steel components in cast iron body Weight: 5.22 kg Mounting: two bolts Relief Valve: see Table 2, ordering codes Symbol Features P r i o r i t y flow rate is pre-set in factory to customer specification between 7.57 lpm and 121 lpm in increments of 7.57 lpm. Flow through the Priority port will remain constant at the pre-set value as long as input flow equals or exceeds the Priority flow value. Pressure compensated permitting both Priority and By-Pass flows to be used simultaneously at varying pressures without effecting the Priority flow rate. Cartridge type relief valve protects the Priority circuit from excess pressure and is adjustable from 34.5 bar to172 bar. (Factory set at 68.9 bar unless otherwise specified). Can be used as unidirectional two port in-line flo w control by plugging the By-Pass flow port (NB: In this configuration a relief valve must be used on the inlet line). Choice of two Priority port connections. Inlet P T BP By-Pass R Priority Regulated Flow 11

ORDERING CODES Typical Code FV 2 1 2 6 FV - Flow Divider Valve Priority (regulated) Flow (Table 1) 1 - Priority Type valve Relief Valve (Table 2) 6 - Nominal Flow Capacity Table 1: Priority (regulated) Flow Code Priority Flow Code Priority Flow 1 7.5 lpm 9 68.13 lpm 2 15.14 lpm 10 75.70 lpm 3 22.71 lpm 11 83.27 lpm 4 30.28 lpm 12 90.84 lpm Table 2: Relief Valve Code Description 0 No Relief Valve 1 Adjustable Brute Force (Direct acting) 2 Adjustable Pilot Operated Table 3: Porting 5 37.85 lpm 13 98.41 lpm 6 45.42 lpm 14 105.98 lpm 7 53.00 lpm 15 113.55 lpm 8 60.56 lpm 16 121.12 lpm Port Description Inlet and by-pass Regulated, Alternate Regulated and Relief Valve Drain Thread 1 5 /8-12 UNF 7 /8-14 UNF INSTALLATION DETAILS Dimensions in millimetres 64.2 76.2 33.3 57.1 PR 27.9 BP RET REG REG 12

FV 200 Series Proportional Flow Dividers P R O P O R T I O N A L FLOW DIVIDERS split a single input flow into two output flows, each output being a fixed proportion of the input. For example, a 50/50 flo w divider will always split a single input flow into two equal output flows which could be used to operate two motors at equal speeds. The actual rate of flow from each output is not fixed but will vary as the input flow rate varies. Specifications Maximum Pressure: 207 bar (workings) Features Pressure compensated to keep each output flow at a fixed percentage of the input flow, regardless of pressure variations between the output ports. Three standard models are available giving proportional splits of 25%/75%, 50%/50% and 40% / 60%. Other proportional splits are available up to 10%/90% (see ordering codes). Three flow ranges are available; 10-30 lpm, 20-50 lpm, 40-76 lpm (see ordering codes). Total Flow Capacity: 76 lpm Porting: see Table 3, ordering codes Materials: steel components in cast iron body Weight: 1.47 kg Mounting: two bolt Symbol 13

ORDERING CODES Typical Code FV200 30 2 J FV 200 - Valve Type Flow Range (Table 1) Output Flow Proportions (Table 2) Porting (Table 3) Table 1: Flow Range Code Recommended Flow Range 30 10-30 lpm 50 20-50 lpm 70 40-76 lpm Table 3: Porting Table 2: Flow Rates Code A/B Ratio % 1 25/75 2 50/50 3 40/60 other ratio available up to 10/90 Code Inlet Port Outlet Ports J 1/ 2 BSP 3/ 8 BSP S 3/ 4 BSP 3/ 4 BSP NOTE: S Ported Valve This valve is produced from a 2FV2V body casting. For installation details see page 17 INSTALLATION DETAILS Dimensions in millimetres 2 Mtg Holes Ø 7.1 Thru (.28 dia) Outlet Port Inlet Port Outlet Port 19.1 49.5 48.8 * Other threads available to special order. 14

VFD 50 Series Variable Priority Flow Dividers P R I O R I T Y TYPE FLOW DIVIDERS split a single input flow into a Priority (regulated) flow and a By-Pass (excess) flow which can be returned directly to the oil reservoir or used to power a second system. In many instances this dispenses with the need for another pump to operate a second system. Specifications Maximum Pressure: 250 bar (working) Total Flow Capacity: 50 lpm Regulated Flow Capacity: see Table 1, ordering codes Porting: see Table 2 ordering codes Features Clearly marked hand-dial permits fast visual adjustments to pre-determined Priority flow and fast easy adjustment of Priority circuit to meet varying requirements. Pressure compensated permitting both Priority and By-Pass flows to be used simultaneously at varying pressures without effecting the Priority flow rate. Can be used as uni-directional two port in line flow control by plugging the By-Pass flow port. (NB: in this configuration a relief valve must be used on the inlet line). Manifold Mounted type available, please consult sales office. Material: steel components in cast iron body: aluminium knob. Weight: 0.75 kg Mounting: 2 Bolt - BSP Ported 4 Bolt - Manifold Symbol Inlet By-pass Priority Regulated Flow 15

ORDERING CODES Typical Code VFD50 30 T Valve Type Regulated Flow Capacity (Table 1) Porting (Table 2) Table 1: Regulated Flow Table 2: Porting Code Regulated Flow Code Port Type 15 0-15 lpm 30 0-30 lpm TYPICAL PRESSURE DROP VFD 50 SERIES Curve established using hydraulic mineral oil ISO 32 with viscosity of 21 centistokes at 50 C T M A 3 / 8 BSP x 3 Ports Manifold Mounted 3/8 NPT x 3 Ports 30 20 10 0 10 20 30 Input Flow (lpm) 40 50 INSTALLATION DETAILS Dimensions in millimetres By-Pass Port 50.0 Inlet 15 15 70 2 Mtg Holes Ø 5.56/5.57 thru Ø 9.5 mm S/Face Priority Port * Other threads available to special order. 16

2FV2V Series Variable Priority Flow Dividers P R I O R I T Y TYPE FLOW DIVIDERS split a single input flow into a Priority (regulated) flow and a By-Pass (excess) flow which can be returned directly to the oil reservoir or used to power a second system. In many instances this dispenses with the need for another pump to operate a second system. Specifications Maximum Pressure: 250 bar (working) Total Flow Capacity: 114 lpm Regulated Flow Capacity: see Table 2, ordering codes Porting: see Table 3, ordering codes Features Clearly marked hand-dial permits fast visual adjustments to pre-determined Priority flow and fast easy adjustments of Priority circuit to meet varying requirements. Pressure compensated permitting both Priority and By-pass flows to be used simultaneously at varying pressures without affecting the Priority flow rate. Can be used as unidirectional two port in line flo w control by plugging the By-Pass flow port. (NB: in this configuration a relief valve must be used on the inlet line). All models can be supplied with an adjustable Pressure Relief Valve on Priority flow. Material: steel components in cast iron body; aluminium knob (steel knob optional) Weight: 2.10 Kg Mounting: two bolt Relief valve: (optional) adjustable between 35-207 bar - Max. Priority flow : 50 lpm Symbol See Installation Details 17

ORDERING CODES Typical Code 2FV2V 125 J ( ) Valve Type (Table 1) Regulated Flow Capacity (Table 2) Porting (Table 3) Pressure Setting (bar, if Relief Valve required) Table 1: Valve Type Code 2FV2V RV2FV2V RVXD2FV2V Table 3: Porting Description No Relief Valve Relief Valve between Priority and Excess Flow Port Externally Drained Relief Valve Table 2: Regulated Flow Code Regulated Flow 030 0-11 lpm 050 0-19 lpm 080 0-30 lpm 125 0-47 lpm 200 0-76 lpm 250 0-95 lpm 300 0-114 lpm Code Port Threads Inlet Regulated Relief Valve External Drain Flow and Excess Flow where fitted J 3 / 4 BSP 1 / 4 BSP A 3 / 4 NPT 1 / 4 NPT M M22 x 1.5 M14 x 1.5 G 1.1/16-12 SAE 9 / 16-20 SAE H 1 / 2 BSP 1 / 4 BSP T 3 / 8 BSP 1 / 4 BSP TYPICAL PRESSURE DROP2FV2V SERIES Curve established using hydraulic mineral oil ISO 32 with viscosity of 21 centistokes at 50 C 12 10 8 6 4 2 0 20 40 60 80 100 120 Input Flow (lpm) * Other threads available to special order. 18

INSTALLATION DETAILS Dimensions in millimetres 2FV2V (No Relief Valve) By-Pass Flow Port 77.8 Inlet SYMBOL P Inlet By-pass Priority Regulated Flow 96.8 2 Mtg Holes Ø7.1 Thru 25.9 49.5 Regulated Port RV2FV2V (Internal Relief Valve between Priority and Excess Flow Ports) Minimum Adjustment 121.6 118.8 46.4 77.8 By-Pass Flow Port SYMBOL P Inlet Inlet By-pass Priority Regulated Flow Priority Port 49.5 2 Mtg Holes Ø7.1 Thru RVXD2FV2V (Externally drained Relief Valve) By-Pass Flow Port 96.8 77.8 Inlet 21.1 P Inlet SYMBOL External Drain From Relief Valve 49.5 22.9 Regulated Port 2 Mtg Holes Threaded M8 x 1.25 By-pass Priority Regulated Flow 19

SECTIONED VIEW Circuit 1 2FV2V Variable Flow Dividers Priority Regulated Flow Hydraulic Motor INLET By-pass Circuit 2 Hydraulic Motor CIRCUIT SUGGESTIONS 1 Variable Speed of Hydraulic Motor Drive on Agricultural Tractor This circuit gives the capability to vary the speed of a hydraulic motor as required. Also, for a given control knob setting, the hydraulic motor speed stays constant regardless of the tractor speed. 2 Two Circuits From a Single Pump Using only one pump, this circuit gives speed control of the hydraulic motor and powers a hydraulic cylinder. Each function can be used either simultaneously or independently because pressure variations between regulated and by-pass flows do not effect the flow on the regulated circuit. INLET 2FV2V Variable Flow Divider Regulated By-pass Hydraulic Cylinder 3 Multiple Circuits From a Single Pump Using one pump, this circuit gives independently variable speed drive from three hydraulic motors. Motors can be used simultaneously or independently. INLET Reg. By-pass Circuit 3 Reg. Hydraulic Motors By-pass Reg. 2FV2V Variable Flow Divider By-pass 20

2FV2V Series Variable Priority Flow Divider with Motor Drive P R I O R I T Y TYPE FLOW DIVIDERS split a single input flow into a Priority (regulated) flow and a By-Pass (excess) flow which can be returned directly to the oil reservoir or used to power a second system. In many instances this dispenses with the need for another pump to operate a second system. Specifications Maximum Pressure: 250 bar Total Flow Capacity: 114 lpm Regulated Flow Capacity: see Table 2, ordering codes Porting: see Table 1 Features Min. to full Priority flow in 15 seconds. Powered from Nom. 12 VDC (12-16 VDC). Electric motor drive permits adjustment from a position away from the valve such as a cab or a control panel. Pressure compensated permitting both Priority and By-Pass flows to be used simultaneously at varying pressures without effecting the Priority flow rate. Can be used as unidirectional two port in line flo w control by plugging the By-Pass flow port. (NB: in this configuration a relief valve must be used on the inlet line). Material: Steel components in cast iron body Weight: 2.75 kg Power Supply: 12V Peak Current: 1.0 Amp Symbol M Inlet By-pass Priority Regulated Flow 21

ORDERING CODES Typical Code 2FV2V 125 J E Valve Type Regulated Flow Capacity (Table 2) Porting (Table 1) Motor Drive Table 1: Porting Code Port Threads J 3 / 4 BSP M M22 x 1.5 T 3 / 8 BSP Table 2: Regulated Flow Code Regulated Flow 030 1 / 2-11 lpm 050 1 / 2-19 lpm 080 1 / 2-30 lpm 125 1 / 2-47 lpm 200 1 / 2-76 lpm 250 1 / 2-95 lpm 300 1 / 2-114 lpm INSTALLATION DETAILS Dimensions in millimetres 85.0 217.0 80 2 Core PVC Insulated Cable. Power supply to Blue Brown Cable Cable Function -ve +ve Valve opens +ve -ve Valve closes * Other threads available to special order. 22

FDM Series Variable Priority Flow Divider with Remote Proportional Control THE FDM REMOTE CONTROL FLOW DIVIDER is ideally suited for the agricultural and industrial user seeking a cost-effective method of controlling hydraulic motor speed. The priority flow port gives an output independent of load pressure while the bypass port can be used to power a secondary circuit. Specifications Maximum pressure: 250 bar Total flow capacity: 114 lpm Regulated flow capacity: see Table 2 Porting: see Table 1 Material: Steel components in a cast iron body. Drive mechanism mounted on aluminium supports Weight: 2.75 kg Power supply: 9-28 V Peak current: 2.5 A Average current: < 100 ma Features Minimum to maximum priority flow in less than 3 seconds (at full pressure) 9-28 V D.C. supply enables unit to be powered from a vehicle supply Remote control using: Potentiometer 4-20 maloop CAN Bus Remote operating distance: up to 40 m Pressure compensated permitting both priority and bypass flow to be used simultaneously at varying pressures without affecting the priority flow rate Automatic current limiting to prevent overheating and motor overload Valve settings immune to power failure Tolerant to vibration and oil contamination Valve cover zinc plated and Teflon coated for corrosion resistance Teflon is a Registered Trademark of DuPont Dust / water protected to IP 675 CE Marked Symbol M Inlet By-pass Priority Regulated Flow 23

ORDERING CODES Typical Code FDM 125 J P Valve Type Regulated Flow Capacity (Table 2) Porting (Table 1) Control (Table 3) Table 1: Porting Table 2: Regulated Flow Table 3: Control Code Port Threads Code Regulated Flow Code Control T 3 / 8 BSP 030 1 / 2-11 lpm P Potentiometer H 1 / 2 BSP 050 1 / 2-19 lpm J 3 / 4 BSP 080 1 / 2-30 lpm 125 1 / 2-47 lpm 200 1 / 2-76 lpm 250 1 / 2-95 lpm 300 1 / 2-114 lpm INSTALLATION DETAILS - VALUE Dimensions in millimetres Ø76 REG PR Cable entry at base 63 150 102 85 Mounting holes Ø 4 3 2 1 0 4 5 6 7 8 9 10 Webtec Products Limited 114 150 *Other threads available to special order. 24

2FV2V Series Manifold Mounted Variable Priority Flow Divider P R I O R I T Y TYPE FLOW DIVIDERS split a single input flow into a Priority (regulated) flow and a By-Pass (excess) flow which can be returned directly to the oil reservoir or used to power a second system. In many instances this dispenses with the need for another pump to operate a second system. Specifications Maximum Pressure: 250 bar (working) Total Flow Capacity: 114 lpm Regulated Flow Capacity: see Table 1 ordering codes Features Pressure compensated permitting both Priority and By-Pass flows to be used simultaneously at varying pressures without affecting the Priority flow rate. Can be used as uni-directional two port in line flow control by plugging the By-Pass flow port. (NB: in this configuration a relief valve must be used on the inlet line). Available with:- Knob Adjustment (Page 17) Electric Motor Drive (Page 21) Positional control (Page 23) Manifold Mounted. Material: steel components in cast iron body Weight: 2.75 kg Mounting: 4 Bolt Manifold Symbol Inlet By-pass Priority Regulated Flow 25

ORDERING CODES Typical Code M 2FV2V 125 E Manifold Mounted Valve Type Regulated Flow Capacity (Table 1) Control Type (Table 2) Table 1: Regulated Flow Code Control Type K Control Type Electric Table 2: Control Type Code Control 030 0-11 lpm 1 / 2-11 lpm 050 0-19 lpm 1 / 2-19 lpm 080 0-30 lpm 1 / 2-30 lpm 125 0-47 lpm 1 / 2-47 lpm K E P ma Knob Electric Motor Drive Potentiometer 4-20mACurrent Loop INSTALLATION DETAILS ( K TYPE) Dimensions in millimetres 77.8 Inlet Port 9.5 dia 77.8 Excess Flow Port 12.7 dia Priority Port 9.52 dia. 4 Mounting Holes 7.15 dia 96.7 49.5 NOTE: Other Installation Details For electric motor type see page 22 For potentiometer current loop type see page 24 26

MM80 Series Manifold Mounted Variable Priority Flow Divider P R I O R I T Y TYPE FLOW DIVIDERS split a single input flow into a Priority (regulated) flow and a By-Pass (excess) flow which can be returned directly to the oil reservoir or used to power a second system. In many instances this dispenses with the need for another pump to operate a second system. Specifications Maximum Working Pressure: 250 bar Total Flow Capacity: 80 lpm Features Clear hand-dial permits fast visual adjustment to pre-determined Priority flow and fast easy adjustments of Priority circuit to meet varying requirements. Pressure compensated permitting both Priority and By-Pass flows to be used simultaneously at varying pressures without affecting the Priority flow rate. Manifold mounted. Regulated Flow Capacity: 47 lpm Material: steel components in cast iron body Weight: 3 kg Mounting: 4 bolt manifold Symbol Inlet By-pass Priority Regulated Flow 27

ORDERING CODES Typical Codes MM 80 47 Valve Type Flow Capacity Regulated Flow (Table 1) Table 1: Regulated Flow Code Regulated Flow INSTALLATION DETAILS Dimensions in millimetres 180.0 12 1-12 lpm 30 1-30 lpm 47 1-47 lpm 36 100.8 70.6 84.0 46 Inlet Port 12.7 dia Regulated Port 10 dia By-pass Port 12.7 dia 100.8 46 114 4 Holes 11.5 dia. 28

FVDVRV Series Variable Priority Flow Divider with Diverter Valve P R I O R I T Y TYPE FLOW DIVIDER split a single input flow into a Priority (regulated) flow and a By-Pass (excess) flow which can be returned directly to the oil reservoir or used to power a second system. In many instances this dispenses with the need for another pump to operate a second system. Specifications Maximum Pressure: 210 bar (working) Total Flow Capacity: 80 lpm Regulated Flow Capacity: see Table 2, ordering codes Porting: see Table 3, ordering codes Features Adjusting knob permits fast easy adjustment of Priority flow to meet varying requirements. Pressure compensated permitting both Priority and By-Pass flows to be used simultaneously at varying pressures without affecting the Priority flow rate. Can be supplied with a pressure relief valve which is fitted between the Inlet and By-Pass ports. In this case the By-Pass circuit should not be pressurised, i.e. the excess flow should be returned to tank. Diverter valve enables the Priority flow to be switched on or off with the full flow being redirected through the By-Pass port. Material: steel components in cast iron body; aluminium knob (steel knob available) Weight: 4 kg Mounting: two bolt Relief valve: (optional) adjustable to 210 bar - max. flow 50 lpm. Symbol P BP R 29

ORDERING CODES Typical Code FVDVRV 80 010 J 100 Valve Type (Table 1) 80 - Maximum Input Flow 80 lpm Regulated Flow (Table 2) Porting (Table 3) Pressure setting in bar - 210 bar max (if optional relief Valve is required) Table 1: Valve Type Table 2: Regulated Flow Code FVDV FVDVRV Description Variable Flow Divider with Diverter Valve Variable Flow Divider with Diverter Valve and Relief Valve Code Range 010 0-10 lpm 020 0-20 lpm 030 0-30 lpm 050 0-50 lpm Table 3: Porting Code Inlet and by-pass Priority J 1 / 2 BSP 3 / 8 BSP INSTALLATION DETAILS Dimensions in millimetres 95.0 max Diverter Lever shown in Valve Closed position Flow Control Knob 350 Rotation 120 2 Mounting Holes 10.0 dia thru 121 CRS 10 38 166.0 26 Relief Valve Regulated Port 39 31 26 Inlet By-pass 30

FDC 60 Series Flow Divider Combiner A FLOW DIVIDER-COMBINER will divide a single flo w into two separate flows which will always be in the same ratio to each other regardless of any pressure d i fferential between the two lines. If the flow is reversed (e.g. return stroke of two cylinders) the return flows are held in the same ratio to each other and combined into a single flow, regardless of individual loads on the cylinders A common application is to keep two cylinders (or motors) in close unison when loads on them are unequal. The valves may also be used in series to operate more than two circuits. Specifications Maximum Pressure: 310 bar (working) Features Pressure compensated to keep the two divided flow rates at the same ratio regardless of pressure variations between them. Flow ratios are pre-set at factory from 50%/50% up to 10%/90%. Flow ranges are available from 5 lpm to 70 lpm. Cast iron/hardened steel construction (no aluminium) makes it suitable for mining applications. Total Flow Capacity: 70 lpm Porting: see Table 2, ordering codes Materials: steel components in cast iron body Weight: 2.05 kg Mounting: three bolt Symbol Port P Port A Port B 31

ORDERING CODES Typical Code FDC 60 10 3 A40% B60% FDC 60 - Valve Type Recommended Flow Range (Table 1) Porting (Table 2) Divider Ratio (Table 3) Table 1: Recommended Flow Range Code Flow Range 05 2-5 lpm 10 5-10 lpm 20 8-20 lpm 30 16-30 lpm 40 25-40 lpm 50 35-50 lpm Table 3: Divider Ratio A B 50% 50% thru 90% 10% NB: Either outlet port (Aor B) may be designated to take either leg of the ratios. The example shown designates 40% at Aand 60% at B. Any ratio from 50% 50% to 90% 10% may be specifie d. 60 45-60 lpm 70 55-70 lpm Table 2: Porting (choose from following codes) Code Port P Port A Port B 1 M18 x 1.5 M18 x 1.5 M18 x 1.5 2 M22 x 1.5 M18 x 1.5 M18 x 1.5 3 3 / 8 BSP 3 / 8 BSP 3 / 8 BSP 4 1 / 2 BSP 3 / 8 BSP 3 / 8 BSP 5 1 / 2 BSP 1 / 2 BSP 1 / 2 BSP 6 7 / 8-14 SAE 3 / 4-16 SAE 3 / 4-16 SAE 7 M27 x 2 M22 x 1.5 M22 x 1.5 8 1 / 2 NPT 1 / 2 NPT 1 / 2 NPT INSTALLATION DETAILS Dimensions in millimetres 50 64 3 Mtg Holes 6.75 dia 32 45 * Other threads available to special order.

Manufacturers of Hydraulic Components and Test Equipment for the Mobile, Industrial and Agricultural Industries Your Webtec Products representative: Webtec Products Limited Nuffield Road, St. Ives, Cambridgeshire, PE27 3LZ, UK Tel: +44(0)1480 397400 Fax: +44(0)1480 466555 E-mail: sales@webtec.co.uk See us at: www.webtec.co.uk Certificate No.8242 Webtec Products Limited reserve the right to make improvements and changes to the specification without notice.