JUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules



Similar documents
Current and Energy. Measurement Technology

Process Automation. Food

Analog signal converters CC-E I/I Current / current isolators

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Contents. Document information

emobility WAGO Leading the Charge

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

SMD Terminal Blocks with Push-Buttons

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

48 SERIES Relay interface modules 10 A

Differential Charge Amplifier

NEW. EVEN MORE data acquisition and test stand automation

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

The Rail-Mounted Terminal Block System

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Modular I/O System Analog and Digital Interface Modules

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

49 Series - Relay interface modules A. Features

Safety technique. Emergency stop module BO 5988 safemaster

Actuator-Sensor-Interface

SMD TERMINAL BLOCKS. Small is Big!

SINEAX U553 Transducer for AC Voltage

MINI MCR-SL-R-UI(-SP)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Wahl C50 Calibrator FEATURES

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Voltage Regulator SPAU 341 C. Product Guide

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Disturbance Recoder SPCR 8C27. Product Guide

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Short information Parameters are programmed via front-side membrane keypad

80 Series - Modular timers 16 A. Features

DS 600. A contact free flux gate based current measurement sensor 600A rms

Pluggable interface relays CR-P Pcb relays

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Features, Benefits, and Operation

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Quick Connect. quick - simple - efficient.

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

FREJA 300 Relay Testing System

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

Rosemount 333 HART Tri-Loop

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Description Part-No. Type PU. Nominal voltage DC12V Relais-SNR 12V 1W 20 DC 24 V Relais-SNR 24V 1W 20

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

2002 IS Catalog. Page

60 Series - General purpose relays 6-10 A. Features

Measuring Temperature withthermistors a Tutorial David Potter

MLC TM Maximum Productivity and Versatility for Control without Compromise!

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

SIMADYN D Digital Control System. Interface module SE21.2. User Manual. Edition DK-Nr

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Number 1 in efficiency

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Installation manual. Generator Paralleling Controller GPC multi-line C

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relay CM-PFE

38 Series - Relay interface modules A

Thermistor motor protection

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

S-series Electronic Marshalling

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Frequency Converter Fv

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Safety automation solutions

Low and High Voltage Power Supplies

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

+5 V Powered RS-232/RS-422 Transceiver AD7306

Trip circuit supervision relay. Type RXTCS

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

40 Series - Miniature PCB/Plug-in relays A. Features

38 Series - Relay interface modules A

USB-AD16f Data acquisition system (USB)

Permissible ambient temperature Operation Storage, transport

Safety Relays ESM/ESM-F

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Panel Meters and Controllers Modular Panel Meter Type EDM 35

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

The Universal DAQ Device. Connect and measure immediately!

ABB Drives. User s Manual HTL Encoder Interface FEN-31

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Electric Rotary Actuator - On/Off or programmable control actuator

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Telephone- and leased line modem for industrial applications TD-36

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

Transcription:

0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27 32423 Minden Phone: Head Offi ce 0571/887-0 Sales 0571/887-222 Order Service 0571/887-333 Technical Support 0571/887-555 Fax 0571/887-169 E-mail info@wago.com nternet www.wago.com JUMPFLEX 857 Series Transducers / Relay and Optocoupler Modules

JUMPFLEX 857 Series A complete product line is available, bringing each signal into shape. The perfect match of housing and electronics is the key to a highly successful device. This goal has been achieved by WAGO with the new family of 857 Series Transducers and Relay Modules. solation Amplifiers Transducers W mv U, Millivolt Transducer Passive solators 1 1 Limit Switch 2 2 Repeater Supplies () () U U PT100 s for RTD Signal Splitter ϑ s for Thermocouples Relay and Optocoupler Modules W Optocouplers DC Relay Modules AC/DC Relay Modules DC AC/DC DC Relay Modules with Gold Contacts AC/DC Relay Modules with Gold Contacts JUMPFLEX - The ntelligent Solution!

Multi-Talented with High Profile Uniquely Compact True 6.0mm/0.236in width allows for space saving. For Extreme Applications Extended range of temperatures from -25 C to +70 C allows for wide application areas. Flexibility at ts Finest Configuration via DP switch. Temperature transducers can also be configured via software. Highest Safety All devices provide safe isolation with 2.5kV test voltage to EN 610. Clear dentification Clear marking using the WMB Multi marking system. Vibration-Proof, Fast and Maintenance-Free CAGE CLAMP S connection for all types of wires. Commoning, Not Discrete Wiring Same outline allows the use of a single inline jumper. solid flexible ferruled AWG 28... 12 AWG 28... 12 AWG 22... 0.08 mm 2... 2.5 mm 2 0.34 mm 2... 2.5 mm 2 0.25 mm 2... 1.5 mm 2

LSTED Transducers Technical Data for Transducers solation Amplifier Configurable solation Amplifier Fixed Setting Repeater Supply Repeater Supply HART Signal Splitter Passive solator 1 Channel Passive solator 2 Channels < 96 mm/3.76 in > < 94 mm/3.68 in > Module width: 6.0 mm/0.236 in Test voltage: 2.5 kv AC / 50 Hz / 1 min Transmission error: < 0.1 % of full scale value Supply Voltage: 16.8 V... 31.2 V Temperature range: -25 C... +70 C Approvals: 1, r, g* () () U U tem no. 857-400 857-411 / 857-412 857-420 857-421 857-423 857-451 857-452 Configuration DP switch DP switch DP switch nput signal 0... 20 ma, 4... 20 ma, 0... 5 V, 0(4)... 20 ma (857-411) 0... 20mA, 4... 20mA 4... 20 ma 0... 20 ma, 4... 20 ma, 0... 5 V, 0(4)... 20 ma 0(4)... 20 ma (switchable in a calibrated way) 0... 10 V, 2... 10 V, 1... 5 V 0(2)... 10 V (857-412) 0... 10 V, 2... 10 V, 1... 5 V Output signal 0... 20 ma, 4... 20 ma, 0... 5 V, 0(4)... 20 ma (857-411) 0... 20 ma, 4... 20 ma, 0... 5 V, 4... 20 ma 2 x 0(4)... 20 ma 0(4)... 20 ma 0(4)... 20 ma (switchable in a calibrated way) 0... 10 V, 2... 10 V, 1... 5 V 0(2)... 10 V (857-412) 0... 10 V, 2... 10 V, 1... 5 V Load impedance 600 Ω ( output) 600 Ω (857-411) 600 Ω ( output) 230 Ω... 600 Ω 2 x 300 Ω 600 Ω 600 Ω 2 kω (U output) 2 kω (857-412) 2k Ω (U output) Max. operating frequency 100 Hz / > 5 khz 100 Hz 100 Hz / 1 khz 100 Hz signal / > 2.5 khz HART 100 Hz / 5 khz 100 Hz 100 Hz 1 2 Voltage supply U N 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 1 2 1 2 * pending Bipolar solation Amplifier Millivolt Transducer Limit Switch for RTDs for RTDs for Thermocouples for Thermocouples ±, ±, ± U,U ± U,U mv U, PT100 PT100 ϑ ϑ tem no. 857-409 857-819 857-531 Configuration DP switch or DP switch or DP switch nput signal ±10 V, 0 (2)... 10 V, Range ± 100 mv 0 (2)... 10V (switchable in a calibrated way) ±20 ma, 0 (4)... 20 ma freely selectable 0 (4)... 20mA, 0... 30V Output signal ±10 V, 0 (2)... 10 V, 0 (4)... 20 ma, 0 (2)... 10 V, 1 changeover contact relay 6 A (switchable in a calibrated way) ±20 ma, 0 (4)... 20 ma 0 (1)... 5 V, 0 (2)... 10 ma 1 digital switch output Load impedance 600 Ω ( output) 600 Ω ( output) 2k Ω (U output) 2 kω (U output) Voltage supply U N 24 V DC 24 V DC 24 V DC tem no. 857-800 857-801 857-810 857-811 Configuration DP switch DP switch or DP switch DP switch or nput signal Pt 100, Pt 200, Pt 500, Pt 1000 Termocouple of type J, K 0 1 kω, 0 4.5 kω Sensor connection 2-wire, 3-wire, 4-wire Measuring range -200 C... +850 C Type J: -150 C... +1200 C Type K: -150 C... +50 C Cold junction compensation on / off (default: on) Output signal 0... 20 ma, 4... 20 ma, 0... 10 V, 2... 10 V, 0... 20 ma, 4... 20 ma, 0... 10 V, 2... 10 V, 0... 5 V, 1... 5 V, 0... 10 ma, 2... 10 ma 0... 5 V, 1... 5 V, 0... 10 ma, 2... 10 ma Output signal (can be inverted) via via Load impedance 600 Ω ( output) 2 kω (U output) 600 Ω ( output) 2 kω (U output) Step response 2- and 4-wire: 180 ms 2- and 4-wire: 60 ms... 3 s Cold junction off : 60 ms Cold junction off : 60 ms... 3 s 3-wire: 360 ms 3-wire: 120 ms... 6 s Cold junction on: 120 ms Cold junction on: 120 ms... 6 s Voltage supply U N 24 V DC 24 V DC Additional configuration options for 857-801/857-811 Series via configuration software Selection of additional sensor nversion of output signal Adjustable step response Configuration software - FDT frame application 759-370 - DTM (Device Tool Manager) WAGO USB Service Cable 750-923 For additional technical data, visit www.wago.com

LSTED Pluggable Relay and Optocoupler Modules Technical Data for Relay Modules Relay Modules with Plugged Miniature Switching Relay Relay Modules with Plugged Miniature Switching Relay Relay Modules with Plugged Miniature Switching Relay Relay Modules with Plugged Miniature Switching Relay < 94 mm/3.68 in > < 81 mm/3.18 in > (1 changeover contact (1u) for normal switching power) U N N tem no. U N N tem no. 12 V DC 17 ma 857-303 24 V AC/DC 8.5 ma 857-354 24 V DC 10 ma 857-304 115 V AC/DC 4 ma 857-357 48 V DC 6.5 ma 857-305 230 V AC/DC 3.5 ma 857-358 60 V DC 5.2 ma 857-306 110 V DC 3.5 ma 857-307 220 V DC 3.2 ma 857-308 DC AC/DC DC AC/DC with gold contacts (1 changeover contact (1u) for normal switching power) U N N tem no. U N N tem no. 24 V DC 10 ma 857-3 24 V AC/DC 8.5 ma 857-364 110 V DC 3.5 ma 857-317 115 V AC/DC 4 ma 857-367 220 V DC 3.2 ma 857-318 230 V AC/DC 3.5 ma 857-368 Module width: 6.0 mm/0.236 in nput voltage range: U N -15 %... +20 % Max. switching voltage: AC 250 V Max. continuous current: 6 A Ambient operating temperature: -25 C... +60 C Approvals: 1, r LSTED Max. continuous current 6 A 6 A Max. switching voltage 250 V AC 250 V AC Nominal operating mode 100 % ED 100 % ED Mechanical life 5 x 10 6 switching operations 5 x 10 6 switching operations Max. continuous current 50 ma* / (6 A ) 50 ma* / (6 A ) Max. switching voltage 36 V DC* / (250 V AC/DC) (250 V AC/DC)* Nominal operating mode 100 % ED 100 % ED Mechanical life 5 x 10 6 switching operations 5 x 10 6 switching operations * n order to prevent the gold layer from being damaged, these values should not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the housing may cause sparkovers between the coil and the contact. n case of damaged gold layer, the values in brackets apply. Technical Data for Optocoupler Modules Optocoupler Modules with Plugged Solid State Relay Optocoupler modules with plugged solid state relay Optocoupler Modules with Plugged Solid State Relay 857-724 < 94 mm/3.68 in > < 81 mm/3.18 in > DC AC/DC DC AC/DC DC AC/DC Max. switching voltage 48 V DC Max. switching voltage 230 V AC Max. switching voltage 24 V DC Max. continuous current 0.1 A Max. continuous current 1 A Max. continuous current 2 A Nominal input voltage tem no. Nominal input voltage tem no. Nominal input voltage tem no. 24 V DC 857-704 24 V DC 857-7 24 V DC 857-724 115 V AC/DC 857-707 115 V AC/DC 857-717 115 V AC/DC 857-727 230 V AC/DC 857-708 230 V AC/DC 857-718 230 V AC/DC 857-728 Module width: 6.0 mm/0.236 in Ambient operating temperature: -25 C... +60 C Approvals: 1, r* * pending For additional technical data, visit www.wago.com

Parameterization of a JUMPFLEX Transducer Select JUMPFLEX transducers can also be parameterized with software (WAGOframe). WAGOframe is FDT/DTM-based software used for parameterization, start-up and diagnostics of fi eld devices. DTM device drivers are required to use the WAGOframe FDT frame application. The WAGOframe FDT frame application provides a wizard, which simplifi es the operation of components such as WAGO JUMPFLEX DTMs. This wizard guides the user through the diff erent operating modes of DTM device drivers. Depending on the PC communication interface used, an appropriate communication cable including DTM is required. Application Examples for Avoiding Corruption of Analog Signals n industrial applications, there are several requirements for safe and economical signal matching that demand appropriate solutions. This is precisely where the strengths of analog technology lie. For several years it has been used successfully in all branches of industry, including factory automation and process technology. Potential Difference The main cause of analog signal corruptions are potential diff erences that arise. With increasing length of the transmission, the ground resistance increases. Thus, diff erences of up to 200V can arise. With signals having ground reference, these ground loops can cause corruptions since particular parts of the signal are not transmitted via analog line, but via the ground. Thus, there is a faulty signal assessment. n this instance, an isolation amplifi er helps since it prevents the arising of a ground current loop. The galvanic isolation of the input circuit from the output circuit breaks up this ground loop and enables perfect signal transmission. Smaller overvoltages with a lower energy level that can arise due to switching operations are dissipated safely. n addition, the output side downstream controller is protected by galvanic isolation. Signal Filtering f the signal to be processed is burdened with disturbances, it is freed of the disturbances by the signal fi ltering with an internal fi lter in the input of the isolation amplifi er. The signal is then transmitted to the superior controller. This way, the devices can be readily adapted to the frequency range in which the disturbance lies using DP switches. The disturbances are thus fi ltered out safely. Linked Measurement Circuits A frequent cause of potential diff erences is linked measurement circuits for which the reference voltage is raised by combining several signal circuits. Thanks to the use of isolation amplifi ers, this problem is eliminated since galvanic isolation of the isolation amplifi er eliminates the infl uence of various reference voltages. The 857 Series JUMPFLEX Transducers off er the series off er a solid contribution to system safety for many problems that occur by realizing a continuous galvanic 3-way isolation with test voltages of 2.5kV between all channels (input/output/supply).