OPERATING INSTRUCTIONS



Similar documents
PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790

Portable Holiday Detectors

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

12-Volt 10-Amp Regulated Power Supply

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Periodic Verification System Model 775PVS

AutoRanging Digital MultiMeter

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

7 FUNCTION DIGITAL MULTIMETER

Manual Ranging MultiMeter

Advantium 2 Plus Alarm

PowlVac Vacuum Integrity Tester

TS93 EMR T/PT/TDE. Surface applied door closer

ETZGAR CONVEYOR COMPANY Controls Section v12.05

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Water Leak Detection System

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

PART 1 - INTRODUCTION...

Secure Keypads for access control

ACL 800 MEGOHMMETER OPERATION MANUAL

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

V1504 Vertical Platform Lift OWNER S MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

User s Manual Before using the inverter, you need to read and save the safety instructions.

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Contractors Guide Central Inverter System Installation

±15 V Current-Limited Power Supply

V1504 Vertical Platform Lift OWNER S MANUAL

Hegel H1 High End Integrated Amplifier

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

ACL 395 Resistivity Meter

User's Guide. True RMS Industrial Multimeter

1 All safety instructions, warnings and operating instructions must be read first.

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

HM-W536 Install Guide

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

FAQ s on Siemens Magmeters

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Operating Instructions

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

16/32 Channel 1U Rack Mount CCTV Power Supply

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

BLOOD COLLECTION MIXER

Seven function digital multimeter

LIEBERT VNSA Installation Sheet

UniStream CPU-for-Panel

E-PDD Duct Smoke Detector Installation Sheet

AMPSEAL* Automotive Plug Connector and Header Assembly

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Building an Electrolysis Copper Cleaner Roy Seifert

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

SMS Alarm. User Manual

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

LINE POWERED ADA TELEPHONE USER S MANUAL Use With Part Numbers , , , , , and

Treasure Cove Metal Detector

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

What is a multimeter?

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Using and Wiring Light Emitting Diodes (LEDs) for Model Railroads

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

=============================== WARNING

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

UV100A Ultraviolet Air Treatment System

19 LED Tube Controller ORDERCODE 41003

Conventional Fire Detection and Extinguishant Control System Specification

WD-AMX Water Detection Controllers

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

PRODUCT MANUAL - M090

Tone Hammer 500. Owners Manual. Manual Version 1.0

CELO5. User & Installation Manual.

CONTIENTS. 1. SPECIFICATIONS (mm) CAUTIONS INSTALLATION INSTRUCTION

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Paint Test Equipment. Holitech DC Holiday Tester Data Sheet

Stage 112. Owner, s Manual P/N

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Odyssey of the Mind Technology Fair. Simple Electronics

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

MODEL 2202IQ (1991-MSRP $549.00)

Configuring the 930A for Common PBX Metallic Signaling Interfaces

Cover Page. Factory Radio Other Documents Available For This Vehicle:

Congratulations! Thank you!

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Transcription:

PIPELINE INSPECTION COMPANY LTD. OPERATING INSTRUCTIONS Wet Sponge Holiday Detectors 670,673, and MSRB Wet Sponge Holiday Detectors Portable and In-Plant Detectors

Table of Contents General Information.......................3 Completing a Circuit.....................4-5 Different Types of Electrodes.................6 Testing.................................7 Model 670 Specifications & Operations.......8-9 Model 673 Specifications & Operations.....10-11 Model MSRB Specifications & Operations...12-13 Model MSRB Station Chart.................14 2

General Information Wet Sponge Holiday Detectors are used for the detection of discontinuities (holidays) in thin film coatings (0-20mils) of paint, epoxy, or any non-conductive material applied to a conductive material. This type of detector uses 67 1 2 volts DC for a test voltage, which is applied to the test surface via a wet sponge. The fluid media (usually water) in the wet sponge fills the voids in the surface to be tested and allows low current (micro-amps) to flow into any holidays in the test area. The current moves through the holiday and into the conductive substrate which activates a horn, light or output to indicate the presence of the holiday. 3

Completing A Circuit 1st METHOD: The first method of completing a circuit is by connecting the ground of the holiday detector to the conductive substrate of the test piece. Which thereby allows the circuit to complete directly from detector through the holiday into the substrate back into the detector. This method is most often used when testing with a portable unit. Battery Covertwist and pull to remove (please note polarity when inserting battery) Pin Hole Holiday on / off ohm test 30 K 100 K Ground Bare Metal Surface Wetted Sponge Ground Cable Non-Conductive Paint Clip 2nd METHOD: The second method of completing a circuit is by grounding the conductive substrate of the test piece by means of a water pipe, conduit, water quenching tank, or other electrically grounded device. This method is usually used when testing with an in-plant unit. Care should also be taken to ensure that the AC power supplied to the inplant units is properly wired and grounded as these units use the ground in the AC circuit to make ground contact. This method completes a circuit from the detector through the holiday into the conductive substrate into the earth ground and back into the detector. 4

NOTE! Wet sponges used by Pipeline Inspection Company, Ltd. are cellulose sponges. Rubber or urethane sponges will not work. While the sponge must be damp to the touch or moist, it should not be so saturated that water runs from the sponge. This can result in the water migrating and causing the current to flow away from the sponge down the test piece to holidays further down the test piece or even to a support piece causing false holiday indications. When the coating thickness is between 11 mils and 20 mils, a low sudsing wetting agent such as those made by KODAK, EDWAL, or PEBEO should be applied to the water (test media). This will allow for a lower surface tension, which will help the test media to penetrate the thicker coatings. (NOTE: PALMOLIVE brand liquid dish soap can be substituted) In general when using a Model 670 or 673 sponge wand electrode, several passes should be made over a given area to ensure that moisture has penetrated any possible holiday. In order to pinpoint a given area, the edge or end of a sponge wand electrode can be used to decrease the area in contact with a test surface. CAUTION! DO NOT use Rubber or Urethane Sponges. Use only Cellulose Sponges. 5

Different Types of Electrodes Different types of electrodes can be used with different units. The most common electrode is a flat sponge electrode wand. This type of wand utilizes a 2 x 4 x 8 (51mm x 102mm x 203mm) size flat sponge. Roller sponges are also available to increase the surface area in contact and the speed also which the test piece can be tested. Roller sponge assemblies are also utilized when using the Rebar Roller System (RBRS) that is used when testing multiple pieces of coated rebar in a rebar coating plant. NOTE! Care should be made to ensure that the sponge stays as clean as possible. Dirt or other contamination of the test surface adds resistance, which impedes the current flow capability of the sponge. This can result in missing holidays in the test piece. Roller Sponge Assembly Flat and Roller Sponge 6

Testing No signal adjustment is necessary with the Wet Sponge Holiday Detector. The unit can easily be tested by means of test buttons located on the front of the portable (Model 670) unit and on the rear of the in plant (Model 673) unit. The test is performed by turning the appropriate detector on and then pressing the 80Kohm button. The signal should actuate. Release the 80Kohm button. Then press the 100Kohm button. The signal should NOT actuate. Release the 100Kohm button. This test indicates the unit is in calibration. The Model MSRB multi station in plant unit is not configured for individual line verification due to the multiple lines involved. To verify its output, it must be returned to the factory for re-certification. While the Model 673 can easily be moved from application to application, the model MSRB cannot, thereby minimizing the need to retest in between factory re-certifications. 7

Model 670 Specifications Model 670 Dimensions: 13 X 2.5 X 2 (maximums) 330 mm X 64 mm X 51mm Weight: 2lbs (0.9 kg) Power Supply: (1) 9VDC Alkaline Battery Output: Audible Tone and Red light on detection of Holiday and positive indication of test result. Continuous tone for low battery indication. Wand Dimensions: (Flat Sponge) 25 (635mm) from base to forward tip of Sponge Wand Weight: (Flat Sponge) 1 lb. (0.45kg) Wand Dimensions: (Roller) 25 (635mm) from base to top of Roller Sponge Wand Weight: (Roller) 1 lb. (0.45kg) Enclosure: Plastic Non Conductive Ground: via side mount connection with wire and alligator clip 8

Model 670 Operations 1. Remove the Battery Cover at the base of the 670 handle. 2. Install a fresh 9 volt Alkaline Battery (noting to ensure the proper connection to the snap fitting) and secure the cover to the handle. 3. Test the unit for proper operation. Turn the unit on. Press the 80K test button. The horn should sound. Release the 80K test button and press the 100K test button. The horn should not sound. Upon passing this test the unit is verified as being in calibration and ready for use. 4.Attach the ground cable to the black Banana Jack coming out of the side of the unit. Attach the clip end to the exposed conductive substrate or ground (if the test surface is properly grounded). 5.After the sponge is properly wetted, move it slowly and repeatedly over the surface area to be tested to ensure the moisture penetrates any holiday. 6.If a holiday is detected the horn will sound and the light will glow. 7.If the battery discharges to a low level, the detector will begin to tone continuously. 9

Model 673 Specifications Model 673 Dimensions: 7.7 X 3.25 X 7.5 196 mm X 83 mm X 190 mm Weight: 2lbs (0.9 kg) Power Supply: 110 VAC 50/60Hz Outputs: Red Light on the front Panel and Horn on detection of holidays are positive test indication. Rear Panel output switched 110 VAC supplies (2) for remote counter, horn, auto-marker, bell, or control system. Power switch light to indicate power on/off condition. Wand Dimensions: (Flat Sponge) 25 (635mm) Wand Weight: (Flat Sponge) 2 lbs. (0.9kg) Enclosure: Plastic Top and Bottom with metal front and back panels. 10

Model 673 Operations 1. Ensure that the pipe or surface to be tested is properly grounded via water bath, water pipe, conduit, or other electrically grounded device. 2.Attach the appropriate wet sponge wand with roller or flat sponge to the unit via the Banana Jack in the rear of the unit. 3. Turn the unit on. The light on the ON/OFF switch will glow if power is present and ON. Push the 80K test switch and verify the front panel horn sounds and the front panel red light glows. Push the 100K test switch and verify that neither the horn or light indicates. 4.Ensure that the Wet Sponge stays appropriately wet and in contact with the test surface. Make sure that the sponge passes over the test surface slowly enough to allow the moisture to penetrate any holidays on the surface. 5.If a holiday is detected, the light on the front panel will glow and the horn on the front panel will sound. 6.The 110 VAC Signal Outlets on the back can be attached to remote horns, bells, relays or counters. They will provide power in concert with the front panel red light and horn. 11

Model MSRB Specifications Model MSRB Dimensions: 15.5 X 6 X 9 394 mm X 152 mm X 229mm Weight: 13 lbs (6 kgs) Power Supply: 110 VAC 50/60Hz Number of Channels: 3 standard positions, optional add on 4th, 5th, and 6th station. Outputs: Front Panel Lights and Rear Panel output switched 110 VAC supplies (2) for remote counter, horn, auto-marker, bell, or control system which activate on detection of a holiday on each individual circuit. Power switch light to indicate power on/off condition. One overall system output is available if you wish to know if any holiday is detected without concern for which individual line the holiday was on. Sensing System: RBRS rebar roller system - dimensions vary depending on application. Flat Sponge wands are also available. NOTE! The RBRS Rebar Roller System is custom designed for each Rebar coating plant. The mounting and spacing requirements for each system will be different due to your unique application needs. 12

Model MSRB Operations 1. The MSRB operates the same way as the Model 673 except that it includes multiple outlets. The Red power switch indicates a glow when the unit is turned on and in the presence of power. No test calibration switches are provided for the MSRB due to the fact that this unit is installed and not moved. Recalibration verification can only be provided at the factory. 2.Ensure that you are careful to note the number of each wand as you attach it to the appropriate Banana Jack on the back of the unit. 3.The Signal Outlet underneath each Banana Jack provides power to activate any remote horn, bell, counter or relay relating specifically to the presence of a holiday on that test line only. 4.The Signal Outlet located above the power supply input provides a positive indication when any line in the MSRB indicates the presence of a holiday. 5.The MSRB provides no internal horn to audibly indicate the presence of a holiday. 6.The Red Lights on the front panel will indicate the presence of a detection of holiday on the individual indicated line. RBRS Sponge Electrodes Drive OR Guide Rollers MSRB Detector Recirculating Water Tank Coating Machine Signal Output to Indication Recording Devices 13

MSRB / RBRS Station # Location Description 1 2 3 4 5 6 Front View Back View 14

NOTES 15

Pipeline Inspection Co., Ltd. Shipping Address: 1919 Antoine Houston, Texas 77055 www.picltd.com Tel: 713/681-5837 Fax: 713/681-4838 E-mail: sales@picltd.com 11.10.03