Both variants can be used for measuring the positive sequence voltage Up or the negative sequence voltage Un.



Similar documents
Current and voltage measuring relays

Pilot-wire differential relay for lines with two or more terminals

Voltage Regulator SPAU 341 C. Product Guide

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Bus differential relay REB phase 1MRK BEN Page 1 Issued: September 2006 Revision: C Data subject to change without notice

Disturbance Recoder SPCR 8C27. Product Guide

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Capacitor Protection Relay SPAJ 160 C. Product Guide

47000 SERIES - ELECTRONIC TRANSFORMERS

DS 600. A contact free flux gate based current measurement sensor 600A rms

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Type SA-1 Generator Differential Relay

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

IAV. Time Delay Voltage. For AC and DC circuit applications. GE Multilin 1. Protection and Control. Features and Benefits.

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

RM4TG20 three-phase network control relay RM4-T - range V

Unified requirements for systems with voltages above 1 kv up to 15 kv

Trip circuit supervision relay. Type RXTCS

Automatic Voltage Regulator User s Manual

Hyperlinks are Inactive

Low Voltage Products. Switches Automatic Transfer Switches

FREJA 300 Relay Testing System

Quick Connect. quick - simple - efficient.

Three-phase monitoring relay CM-PFE

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Control Devices Catalogue. Control Devices. Preferred and Standard Products

SECTION VARIABLE FREQUENCY DRIVES

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

Electronic overload relay EF65, EF96 and EF146

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

SX460. Generator Automatic Voltage Regulator Operation Manual

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

THE INPUT/OUTPUT SYSTEM. Key Points

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Thermistor motor protection

UMEC International Corporation

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

How To Protect A Motor From Overcurrent

SURGE PROTECTIVE DEVICES

PSR The compact range Description

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Electronic overload relay EF19 and EF45

40 Series - Miniature PCB/Plug-in relays A. Features

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Three-phase AC circuits

Technical catalogue. Modular DIN rail components Installation contactors

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

DC TRANSMISSION BASED ON VOLTAGE SOURCE CONVERTERS

DS1 Diode-based transient-free capacitor switch

Safety technique. Emergency stop module BO 5988 safemaster

Digital Pressure Measuring Instrument MDR480

7. Reactive energy compensation

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Manual Motor Starter MS 116 up to 16 A Technical Data

Calculation of the Current Transformer Accuracy Limit Factor Application Note

Energy Management Energy Meter Type EM23 DIN

Power transformers. Special transformers Railway

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

What Is Regeneration?

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Busbar differential protection

60 Series - General purpose relays 6-10 A. Features

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

PNEUMATIC CONTROLS Selection and Description

Softstart. Changing of Printed Circuit Board PS S General...2 Please note!... 2

Medium voltage product. Instrument transformers for indoor applications Product overview

ELECTRONIC POWER SYSTEMS

The full wave rectifier consists of two diodes and a resister as shown in Figure

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

Electricity and Magnetism, Georgia, GEOSTM (Georgian National Agency for Standards and Metrology)

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

MIT510/2, MIT520/2 and MIT1020/2

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Circulating Current Relay. Type IRXm

Thyristor-controlled power supplies and battery chargers

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

A project to optimise quality and energy efficiency must include metering

Agilent 87421A/87422A Power Supply

Properties of electrical signals

Step Voltage Regulators

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

Pluggable interface relays CR-P Pcb relays

2SD315AI Dual SCALE Driver Core for IGBTs and Power MOSFETs

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

2.1 FOR Series 15i Servo Alarm TROUBLESHOOTING 2.ALARM NUMBERS AND BRIEF DESCRIPTIONS. Alarm No. SVM PSM Description Remarks

48 SERIES Relay interface modules 10 A

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM

Auxiliary Relay. Type P8n, PQ8n, PN8n

Product Data Bulletin

Technical Information Requirement for MV transformers and transformer for internal power supplies for SUNNY CENTRAL

Safety automation solutions

Transcription:

Rev. - 2004-10-22 Page 1(5) General RXTBA 1 is a three-phase phase sequence voltage filter built up by resistors and capacitors. The filter is available in two voltage variants; one for rated voltage 3x110 V 50 Hz and one for rated voltage 3x120 V 60 Hz. Both variants can be used for measuring the positive sequence voltage Up or the negative sequence voltage Un. The filter has two outputs adapted to supply the connected output relay with a voltage proportional to either the positive or the negative phase sequence component in the input voltage. The output voltage in volt is equal to the phase sequence voltage in percent of the rated voltage when the output is loaded with the recommended output relay type RXEDK 2H, e. g. the relay voltage is 80 V when the positive phase sequence voltage is 80 % of the filter rated voltage and with the filter connected for positive sequence measuring. Following operate values can be achieved together with the recommended output relays RXEDK 2H Positive sequence voltage Up: 25 150 % of the filter rated voltage Negative sequence voltage Un: 2,5 15 % of the filter rated voltage The filter RXTBEA 2 is phased out during 2005. The relay type RXEG 21 with scales 5-15 V and 40-120 V (used with RXTBEA 2) can also be used together with the RXTBA 1 filter to measure the negative and positive sequence voltages in the approximate ranges Un=9-27 % and Up= 38-115 % of the filter rated voltage. Application The filter RXTBA 1 is used when it is required to measure or check the positive sequence voltage Up or the negative sequence voltage Un in a three-phase network. RXTBA 1 for measuring the positive sequence voltage Up, and undervoltage relay RXEDK 2H or RXEG 21, are used for indicating the voltage drop in the three-phase voltage, e. g. in loadshedding protection. RXTBA 1 for measuring the negative sequence voltage Un, and overvoltage relay RXEDK 2H or RXEG 21, are used for indicating incorrect phase sequence or phase failure. If one phase to a motor is broken by a fuse, the back emf of the motor holds up the voltage in the open phase. Therefore an undervoltage relay may not surely be able to measure this abnormal condition, but a relay connected to a filter measuring the negative sequence component can do it. The per unit negative sequence component of the voltage resulting from an open conductor to a motor is equal to the ratio of the running to the starting currents of the motor. For example, a motor with a starting current of 6 per unit, the negative sequence voltage is approximately16 %of rated voltage if the motor was running at full load when the fuse blew. The voltage is less if the motor was lightly loaded before the fuse blew. 1MRK3-368 B

Page 2(5) Output relays Measuring of the positive sequence voltage Up: The recommended relay is RXEDK 2H, 1MRK 000 841-RA, set for scale constant Us = 1,0 x Ur and connected for Ur = 100 V 50-60 Hz according to Fig. 1, giving the scale ranges: U1 = 50-100 V and U2 = 25-150 V. The filter output is calibrated so the voltage to the connected recommended relay RXEDK 2H is 100 V when the filter is energized with a positive sequence voltage equal to 100 % of the filter rated voltage. Then the output voltage is directly proportional to the positive sequence voltage in to the filter. Thus the setting ranges in positive sequence voltage are U1=50-100 % and U2=25-150 % of the filter rated voltage. The filter can also be used together with RXEG 21, RK 411 101-DD or RK 411 102-DD, scale range 40-120 V. The setting range in positive sequence voltage is approximately 38-115 % of the filter rated voltage. Measuring of the negative sequence voltage Un: The recommended relay is RXEDK 2H, 1MRK 000 841-KA, set for scale constant Us = 0,2 x Ur and connected for Ur = 50 V 50-60 Hz according to Fig. 2, giving the scale ranges: U1 = 6-12 V and U2 = 3-18 V. The filter output is calibrated so the voltage to the connected recommended relay RXEDK 2H is 100 V when the filter is energized with a negative sequence voltage equal to 100 % of the filter rated voltage. Then the output voltage is directly proportional to the negative sequence voltage in to the filter. Thus the setting ranges in negative sequence voltage are U1=6-12 % and U2=3-18 % of the filter rated voltage. The filter can also be used together with RXEG 21, RK 411 101-DA or RK 411 102-DA, scale range 5-15 V. The setting range in negative sequence voltage is approximately 9-27 % of the filter rated voltage. Check of the operate value The operate value of the relay connected to the filter can be checked by using a single phase voltage source. Disconnect the ordinary 3-phase voltage source from the filter input terminals 11, 21 and 22. Then connect the terminals 11 and 22 together and connect an adjustable AC voltage to the terminals 11 and 21. This AC voltage is to be three times the voltage to neutral for 3-phase systems to produce the corresponding output voltage. A relay which is to operate at 10 % of the rated voltage 3x110 V, should operate at approximately 3 x 0,10 x 110/3 = 19 V single phase.

Page 3(5) Technical data Rated voltage Ur Overload capacity continuously during 10 s Output voltage to the recommended output relay Setting ranges with RXEDK 2H, 1MRK 000 841-RA stage U1 stage U2 RXEDK 2H, 1MRK 000 841-KA stage U1 stage U2 RXEG 21, scale 40-120 V RXEG 21, scale 5-15 V 3x110 V 50 Hz and 120 V 60 Hz 120 % of Ur 150 % of Ur 1 V per positive or negative sequence voltage in % of the rated voltage Ur 50-100 V, equal to Up=50-100 % of Ur 25-150 V, equal to Up=25-150 % of Ur 5-10 V, equal to Un=5-10 % of Ur 2,5-15 V, equal to Un=2,5-15 % of Ur Equal to approximate Up=38-115 % of Ur Equal to approximate Un=9-27 % of Ur Power consumption 0,4-0,6 VA per phase at U=Ur Nominal operative temperature range -25 ºC to +55 ºC Dielectric test Impulse voltage test Dimension Weight 2,0 kv, 50 Hz, 1 min 5,0 kv, 1,2/50 s, 0,5 J 2U 6C 153 g

Page 4(5) Fig. 1. Terminal diagram for measuring the positive sequence voltage Up Fig. 2. Terminal diagram for measuring the negative sequence voltage Un

Page 5(5) Ordering Specify Phase sequence filter RXTBA 1 Voltage relay RXEDK 2H DC/DC converter RXTUG 2H Quantity Ordering No. according to below RXTBA 1, Ur= 3x110 V 50 Hz 1MRK 002 261-AA RXTBA 1, Ur= 3x120 V 60 Hz 1MRK 002 261-BA RXEDK 2H, Ur=20/50 V 50-60 Hz (sharp) 1MRK 000 841-KA RXEDK 2H, Ur=100/200 V 50-60 Hz (standard) 1MRK 000 841-RA RXTUG 2H, 24-250 V DC / ±24 V DC 1MRK 000 592-A References Time over/under voltage relay RXEDK 2H DC-DC converter RXTUG 22H Connection and installation components Relay mounting systems 1MRK 509 004-BEN 1MRK 513 001-BEN 1MRK 513 003-BEN 1MRK 514 001-BEN ABB Power Technologies Substation Automation Products Nätverksgatan 3, Västerås, Sweden Phone: +46 21 342000, Fax: +46 21 324223 www.abb.com/substationautomation