viridian solar Catalogue 2016 www.viridiansolar.co.uk



Similar documents
Solar Collector Series. Product List

viridian solar Clearline fusion roof integrated solar PV

StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Electric Flow Boiler

Link-Up. Solid Fuel Association Guide to Central Heating.

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

UBBINK SOLAR IN-ROOF SYSTEM

Builder Specifications for Solar Ready Homes

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun

Plumbing and Electrical Installation Guide

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

maximise the sun s energy with warmflow solar Warmflow Solar

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Free electricity for your home, offices or factory with solar PV panels

ECOplus Solar Cylinder

Volther Hybrid PV-T Panels

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

UNDERSTANDING CENTRAL HEATING SYSTEMS

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

Session 2: Hot Water Supply

Solar power system installation for homes & businesses

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

SOLAR HEATING SYSTEMS.

Vacuum Tube Solar Water heater Non-pressure. User manual

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

Making Your Home Ready For Solar Water Heating

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Photo Kirklees IS SOLAR ENERGY FOR ME? A guide to going solar

Solar Water Heating and Photovoltaic Electrical Systems Installed on One or Two Family Dwellings

Installation Instructions for Contractors. Connection Sets. Solar Twin Tube. Inox 1/2" Inox 3/4" (2011/02) US/CA

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

MFP14, MFP14S and MFP14SS Automatic Pumps

Apartment and Communal Heating Solutions

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Sustainable Schools Renewable Energy Technologies. Andrew Lyle RD Energy Solutions

Model Number Electrical Compatibility Module Connector Type. M LL-S22 60 cell PV module MC-4 Type 2 Locking

SunMaxx Solar Filling Station Operating Instructions

Engage Coupler. Engage Coupler Chase

VOYAGER 570G. 744A Sprayer Control

Air Source Heat Pump Installation and Maintenance Manual

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

GUIDELINES FOR PLAN CHECK AND PERMIT REQUIREMENTS FOR SOLAR ENERGY SYSTEMS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Harvesting Solar Energy

Isotemp Basic, Slim/B & Slim Square

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Vaillant s plain English guide to. simple, concise and precise

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

GROENEVELD AUTOMATIC GREASING SYSTEMS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

High Output Boiler Systems

6 YEAR * PAYBACK A GUIDE TO DOMESTIC RENEWABLE HEAT INCENTIVE (RHI) SOLAR THERMAL SOLUTIONS

IEC Connectors. Introduction

Installation Instructions

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

TMS TANK MANAGEMENT SYSTEM

1 DESCRIPTION OF THE APPLIANCE

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

for solar domestic hot water and photovoltaic systems

PITCHED ROOF STRUCTURES

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

3/2-way Solenoid Valve, direct-acting, NC or NO

Fully Pumped Systems

What you can expect from your Solar Hot Water System

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

SELECTION, APPLICATION AND MAINTENANCE

Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized

00MK-MA0190-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Universal Light system with locking brackets, for sloped roof

Qualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation

Elson 10/15L Unvented Water Heater

RAIL FREE SOLAR ROOF MOUNT

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

REMOVAL AND INSTALLATION

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Chris & Brenda s Solar Water Heating System

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

ASME Packaged Indirect Fired Water Heater

Laddomat Charging unit

OKU SOLAR HEATING FOR SWIMMING POOLS

Transcription:

Catalogue 206 www..co.uk

About Us Viridian Solar Atlas Building 68 Stirling Way Papworth Cambridge, UK CB23 3GY T 0480 83 50 F 0480 83 83 Viridian Solar s aim is the widespread adoption of energy on our buildings and homes. In 2004, a team of innovative engineers and designers set themselves the challenge to design a system for the mainstream. Viridian sought partners from the building industry to help with the definition of the product and quicky realised that cost wasn t the only thing holding back from wider use. Aesthetics, durability and ease of installation were just as important. The result of the collaboration with developers, construction companies, and other building professionals is a product that transforms the attractiveness of this type of renewable energy. info@.co.uk www..co.uk Launched in 2007, the Clearline range of panels has helped Viridian Solar become established as a leading supplier in the UK, with growing exports. The story of innovation has continued, most recently with the development of Clearline Fusion - a cost effective photovoltaic roofing system, and The Pod - a radical new way to install heating. 2

0022 Contents Clearline fusion oof Integrated PV pages 4-5 Clearline Matching Thermal and PV pages 6-7 Highline On-roof thermal pages 8-9 Solar Panel Insulated Hose page Solar Thermal Controls page 0 & 2 Clearline Boiler Solar PV Electrical Kits page 4-5 Solar Cylinders page 2-3 Spares and Accessories page 6 Technical Prices shown are list price and exclude VAT, which will be charged at 20%. Where you see these symbols click to download: Delivery is not included, please see page 6 for delivery charges to mainland UK. Datasheet Installation Manual The prices in this document are correct as at 4/07/206. Please check with Viridian Solar to ensure that you are working with the current price list. Technical Drawing Or visit our website just for installers: Solarsure.NET/WOK All you need, all in one place. 3

CETIFICATE BBA 0032 CETIFICATE BBA 0032 Clearline fusion PV oofing System Our flagship PV roofing system replaces roof tiles or slates for a sleek, modern aesthetic. High quality monocrystalline PV6 panels have a unique frame that combines with Clearline fusion flashing kits for a rapid, durable and beautiful installation. The system achieves industry-leading wind resistance and AA fire rating without modification to a standard roof construction. MCS 02 accredited. PV6 Series Photovoltaic Panels new PV6-250 PV6-270 250 Wp Clearline PV High Performance Monocrystalline Silicon Solar Photovoltaic Panel, complete with specialised frame for roof integration in combination with Clearline Fusion flashing kits. 270 Wp Clearline PV High Performance Monocrystalline Silicon Solar Photovoltaic Panel, complete with specialised frame for roof integration in combination with Clearline Fusion flashing kits. 22.40 26.37 MCS 4kWp Clearline fusion installation Clearline Fusion oof Integration Kits Universal roofing kit for integration of Clearline PV6 modules with tile and slate of thickness under 45mm. MCS02 accredited. t t<45mm t One kit per panel for rectangular arrays F6-TL Clearline Fusion F6 roofing kit, Left 66.62 F6-TC Clearline Fusion F6 roofing kit, Centre 66.62 F6-T Clearline Fusion F6 roofing kit, ight 66.62 F6-TY Clearline Fusion F6 roofing kit, ow 37.92 F6-J Clearline Fusion F6 roofing kit, Joining 25.62 VAT6 Clearline Fusion F6 roofing kit, single panel 02.50 Universal kits work with both slate and tile new Corner conversion kits for stepped-in or stepped-out arrays F6-CLT Clearline Fusion corner conversion kit, left top corner 56.37 F6-CT Clearline Fusion corner conversion kit, right top corner 56.37 F6-CB Clearline Fusion corner conversion kit, right bottom corner 37.92 F6-CLB Clearline Fusion corner conversion kit, left bottom corner (centre panel above) 87.2 F6-CLB-S Clearline Fusion corner conversion kit, left bottom corner (left panel above) 87.2 MCS Corner conversion kits for stepped arrays 4

CETIFICATE BBA 0032 Sarking Brackets for Scottish Slate For roofs with sarking boards and no battens (common in Scotland) add a conversion kit of brackets for each roofing kit. The only integrated with MCS02 for sarking. SB6-L Fusion sarking bracket kit, for use with F6-TL 7.68 SB6-C Fusion sarking bracket kit, for use with F6-TC 7.68 SB6- Fusion sarking bracket kit, for use with F6-T 7.68 SB6-Y Fusion sarking bracket kit, for use with F6-TY 7.68 SB6-J Fusion sarking bracket kit, for use with F6-J 7.68 SB6-AT Fusion sarking bracket kit, for use with VAT6 on roofs without tile battens 7.68 MCS fusion configurator software makes pricing jobs with fusion a snap, download the free excel workbook here: http://www..co.uk/configurator Clearline fusion Extends to any number of columns and rows Industry leading 5mm spacing Clearline PV6 Hidden fixings for clean aesthetic Aluminium push fit flashing for durability and high fire rating Works with all common tiles and slates including slates over sarking. obust corrugated lead resists wind uplift 5

CETIFICATE BBA 000 CETIFICATE BBA 0032 Clearline Solar Panels Clearline thermal and PV panels are available in matching sizes and use the same roof-mounting details. You can install panels of the same size alongside one another for a combined PV-thermal system with a harmonious appearance. MCS 02 accredited. V series Thermal Panels V20 V30 2m² Clearline High Performance Solar Thermal Panel, (Aperture area 2.2m²), complete with specialised frame for roof integration in combination with Clearline flashing kits. 3m² Clearline High Performance Solar Thermal Panel, (Aperture area 3.m²), complete with specialised frame for roof integration in combination with Clearline flashing kits. 77.46 952.6 Solar heating panels for roof integration MCS PV series Photovoltaic Panels PV20-330 PV30-500 330 Wp Clearline PV High Performance Monocrystalline Silicon Solar Photovoltaic Panel, complete with specialised frame for roof integration in combination with Clearline flashing kits. 500 Wp Clearline PV High Performance Monocrystalline Silicon Solar Photovoltaic Panel, complete with specialised frame for roof integration in combination with Clearline flashing kits. 493.32 697.34 MCS Solar PV panels for roof integration Sizing Guide A PV system is normally sized based on roof space and aesthetics, but a thermal system should be sized to the average hot water demand of the building, which is driven by the average occupancy. Choose the top of the range for installations if orientation is not ideal. Combined installation comprising 2 V20 thermal panels (centre) and 4 PV20 photovoltaic panels. Solar Panel Area (m 2 ).0 2.0 3.0 4.0 5.0 6.0 Typical sizing based on average occupancy 6

Clearline oof Integration Kits (for 20, 30 series) Flashing kits are compatible with both V series thermal and PV series photovoltaic panels and are available in specialised kits to suit tile and slate roofs. Each flashing kit contains components to fit 20 or 30 series panels (see page 3 for PV6 panels). oofing kits are available for both tiled and slate roofs. Clearline roof integrated panels have been tested as a roofing material and are the only products to hold a BBA Agrément certificate. Weathertightness, external spread of flame and wind resistance have been confirmed and all Clearline panels and flashing kits are accredited to MCS02. Electrical or hydraulic connections can be made inside the building, leaving all connections accessible and allowing roofing works to be completely separated from plumbing or electrical works. Panels can be installed either joined together or singly on the roof. Choose the look that you prefer. T Series For tile roofing with profile height between 5mm and 45mm t>5mm t<45mm t t S Series For slate roofing up to 0mm thick Not for interlocking slate t<0mm C Series For tile roofing with profile height up to 20mm and interlocking slate t<20mm VAT Flashing for single Clearline 20 and 30 series panel, suitable for tiled roof. Panel fixing brackets 4.80 VAS Flashing for single Clearline 20 and 30 series panel, suitable for slate roof. Panel fixing brackets 4.80 VAC Flashing for single Clearline 20 and 30 series panel, suitable for pantile roof. Panel fixing brackets 240.87 VTL Flashing for Clearline 20 and 30 series panel, left position in single or bottom row. Tiled roof. Panel fixing brackets 90.20 VSL Flashing for Clearline 20 and 30 series panel, left position in single or bottom row. Slate roof. Panel fixing brackets 90.20 VCL Flashing for Clearline 20 and 30 series panel, left position in single or bottom row. Pantile roof. Panel fixing brackets 53.75 VTC Flashing for Clearline 20 and 30 series panel, centre position in single or bottom row. Tiled roof. Panel fixing brackets 90.20 VSC Flashing for Clearline 20 and 30 series panel, centre position in single or bottom row. Slate roof. Panel fixing brackets 90.20 VCC Flashing for Clearline 20 and 30 series panel, centre position in single or bottom row. Pantile roof. Panel fixing brackets 53.75 VT Flashing for Clearline 20 and 30 series panel, right position in single or bottom row. Tiled roof. Panel fixing brackets 90.20 VS Flashing for Clearline 20 and 30 series panel, right position in single or bottom row. Slate roof. Panel fixing brackets 90.20 VC Flashing for Clearline 20 and 30 series panel, right position in single or bottom row. Pantile roof. Panel fixing brackets 53.75 Tile flashing, single panel VAT Tile flashings, joined panels VTL, VTC, VT Slate flashing, single panel VAS Slate flashing, joined panels VSL, VSC, VS Single Pair un For a joined row of panels, you will need a left and a right flashing for the outside panels, plus a centre flashing kit for each panel between them. VA* Left V*L ight V* Left V*L Centre V*C Centre V*C ight V* 7

Highline TM Solar thermal on-roof panels VHL20 2m² Highline High Performance Solar Thermal Panel, (Aperture area.84m²). For external mounting 399.5 00 Anodised VHL support rails (pair) for 2 panels, portrait 56.25 0 Anodised VHL support rails (pair) for panel, portrait 32.53 VHL thermal panels for clean, frameless aesthetic combined with rapid, simple above-pitched-roof fixing system. The ceramic edge pattern on the cover glass combines with black enclosure and rails for a smart appearance. 02 VHL Support rail joining set: extension bar x2, M8 lock nut x 4, washer x4 05 Panel clamp set for VHL20, clamp x2, hammer head bolt x2, washer x2, lock nut x2 07 Clamp kit for each additional VHL20 : centre clamp, extended head hammer head bolt, M8 lock nut, mounting jig 08 Hammer head bolt 4 pack: hammer head bolt x 4, washer x 4, M8 lock nut x4 2000 Hydraulic connecting set: x 3/4 female end cap, x 3/4 male end cap, x blank, x air vent, x air vent key, 2 x fibre washers 200 Stainless U tube panel connector - DN6-3/4 male - for landscape installation 2002 Stainless U tube panel connector - DN6-3/4 female - for landscape installation 2003 3/4 Blanking disc - to control flow direction in long runs of panels. V227 Temperature sensor with 3m cable and J45 connection (suitable for VHL20 or cylinder) 0.72 9.29.30 7.43 24.92 5.82 0.20 0.97 32.80 V4520 oof Anchor (Large Format flat tile), 2 fixing screws 2.2 V452 oof Anchor, (Plain Tiles), 2 fixing screws 2.2 V4522 oof Anchor (Slates), 2 fixing screws 4.8 V4523 oof Anchor (Profile tile), 2 fixing screws 4.8 V4524 V4530 oof Anchor (slate on sarking without battens), 3 fixing screws Solar slate roof penetration - lead base flashing, single silicone boot 0.99 82.00 05 Panel clamp set for VHL20 07 Clamp kit & jig for each additional VHL20 08 Hammer head bolt 4 pk. 2000 Hydraulic connecting set V4523 oof Anchor for profiled tiles Double oman, Ashmore, Wessex, Mendip, Anglia, Grovebury, egent, enown, Norfolk Pantile, Landmark Pantile, Ludlow V4522 oof Anchor for slates 00 Pair of support rails for 2x VHL20 Portrait orientation 02 Support rail joining set V452 oof Anchor for plain tiles Natural and Fibre Cement Slates V4520 oof Anchor for large format plain tiles 0 Pair of support rails for x VHL20 Portrait orientation osemary Stonewold, Mini Stonewold, Modern Duo, Ludlow 8

Highline Kits Black thermal panels and rails for clean, simple installation above roof. Kits include panels, rails, fixings to rails, roof anchors and panel plumbing connections. Kit excludes pipes/hoses and roof penetrations. K032 6 m 2 thermal on roof 3.7 m K032T 6m2 thermal on-roof kit for pitched tiled roof. Includes 3 x VHL20.84m2 thermal panels, panel rails and fixings, 0 roof anchors (profiled tile), hydraulic connections,57.85 VHL20 VHL20 VHL20.8 m K032S 6m2 thermal on-roof kit for pitched slate roof. Includes 3 x VHL20.84m2 thermal panels, panel rails and fixings (00, 0, 02, 05, 07 x 2, 08 x 3), 0 x V4522 roof anchors (slate), hydraulic connections (2000),57.85 K03 4 m 2 thermal on roof 2.4 m K03T 4m2 thermal on-roof kit for pitched tiled roof. Includes 2 x VHL20.84m2 thermal panels, panel rails and fixings, 8 roof anchors (profiled tile), hydraulic connections,028.36 VHL20 VHL20.8 m K03S 4m2 thermal on-roof kit for pitched slate roof. Includes 2 x VHL20.84m2 thermal panels, panel rails and fixings (00, 05, 07, 08 x 2), 8 x V4522 roof anchors (slate), hydraulic connections (2000),028.36 K030 2 m 2 thermal on roof.2 m K030T 2m2 thermal on-roof kit for pitched tiled roof. Includes VHL20.84m2 thermal panel, panel rails and fixings, 4 roof anchors (profiled tile), hydraulic connections 530.04 VHL20.8 m K030S 2m2 thermal on-roof kit for pitched slate roof. Includes VHL20.84m2 thermal panel, panel rails and fixings (0, 05, 08), 4 x V4522 roof anchors (slate), hydraulic connections (2000) 530.04 Kit Code 2 Aperture Area (m ) Contents: VHL20 00 0 02 05 07 08 2000 V4523 K030T K03T K032T.9 3.82 5.73 - - - 2 - - 3 2 2 3 4 8 0 9

Clearline Clearline Clearline Solar Thermal Control and Installation Drainback Pressurised V200 Simple drain-back plumbing kit. Wall-mounting drainback pump station with controller and integral overpressure catch tank, cylinder sensor. For up to 6m² panel array. 563.75 V260 Pressurised plumbing kit. Wall-mounting pressurised pump station with controller and integral overpressure catch tank, cylinder sensor, 8 litre expansion vessel. 65.00 Clearline h B h A A m 2 Panel Area (m 2) 2 3 4 6 Maximum A+B (m) Clearline Highline 38 3 32 n/a 26 2 4 n/a Maximum h (m) 4.5 A Panel Area (m 2 ) 3 6 9 >9 h Vertical Height (m) 8 2 5 5+ Drainback systems are quick to install and simple to maintain, but must be installed within 4.5m vertical height of the top of the panel and connecting pipes must fall downhill with a slope greater than in 30. Pressurised systems can be installed in a wider range of situations but are more involved to install and maintain. You will also need V223 First Fix Kit. 20m plug-and-play panel sensor cable with in-line connector block. 25.62 V225 Viridian Solar System Fluid. eady to use, 0 litres. 34.72 V227 Temperature sensor with 3m cable and J45 connection (suitable for VHL20 or cylinder) 32.80 650mm Both drainback and pressurised pump sets come in a smart white steel case for wall-mounting. A controller and catch tank for overpressure discharge is integrated into the unit, saving time and reducing clutter in the cylinder cupboard. Clearline heating panels are supplied with a factory-fitted temperature sensor, purchase V223 to connect between sensor and controller. An installation of Highline panels requires a V227 sensor plus V223 cable. Purchase additional V223 to extend the cable run in units of 20m. System fluid - allow at least 8 litres for a V200 drainback installation and 6 litres for a pressurised V260 installation. 340mm 200mm 0

Pre-insulated Pipe 20059 Pre-insulated twin pipe, soft copper 0mm diameter, 25 m length. 3mm PEX insulation. Twin core sensor cable V50 V55 V525 Pre-insulated twin pipe, stainless steel DN6 0m length. 3mm EPDM insulation. Twin core sensor cable Pre-insulated twin pipe, stainless steel DN6 5m length. 3mm EPDM insulation. Twin core sensor cable Pre-insulated twin pipe, stainless steel DN6 25m length. 3mm EPDM insulation. Twin core sensor cable 07.62 33.25 205.00 333.2 Insulated DIN6 stainless steel hose V502 DN6 3/4" to 3/4" nipple VHL VHL 3/4 female flat end connector 3/4 male flat end connector V50 DN6 3/4" to 0mm standpipe 6.57 V500 DN6 3/4" to 5mm standpipe 7.43 Vseries Vseries V504 DN6 3/4" to 22mm standpipe 6.06 V502 DN6 3/4" to 3/4" nipple 5.2 V505 3/4" to 3/4" parallel socket 3.89 V506 DN6 hose sealing washer (pack of 4).46 0mm stainless steel stand pipe V503 Nut, washer, circlip for terminating DN6 pipe 3.0 Note: it is recommended that for Clearline panel installation V223 first fix kit is used for plug and play sensor connection. 0mm straight compression fitting (or sized to suit pipe with compression tee to suit pipe V50 DN6 3/4" to 0mm standpipe to suit pipe V500 DN6 3/4" to 5mm standpipe V504 DN6 3/4" to 22mm standpipe V50 V500 DN6 3/4" to 0mm standpipe DN6 3/4" to 5mm standpipe 0mm compression V200 5mm compression V260 & POD Pre-insulated pipe is available as soft rolled 0mm copper (suitable for drainback installation) and DN6 stainless steel pipe (suitable for pressurised systems) Insulated 0mm copper pipe V50 VHL VHL DN6 3/4" to 0mm standpipe 0mm straight V505 compression fitting 3/4" to 3/4" parallel socket V50 DN6 3/4" to 0mm standpipe Vseries Vseries 0mm stainless steel stand pipe 0mm straight compression fitting 0mm compression tee 5-0mm reducing set 0mm compression V200 5mm compression V260 & POD

The pod The biggest challenge when installing heating isn t fitting the panels on the roof, it s the work inside the home to interface heating with the existing heating system. The Pod is a game-changing new approach that simplifies installation of heating and reduces disruption in the home to an absolute minimum. panel The Pod fits through a standard loft hatch and its horizontal format means it will slide into the tightest corner. The only work inside the house is to run pipework to feed the heated water to the existing heating system. pod Pod PV has an immersion heater which can be powered with excess electricity from a photovoltaic installation. It s a superior approach compared to using the immersion heater in an existing cylinder and Pod PV also makes possible the implementation of PV water heating for homes that have a combi-boiler. cylinder Boiler V240 POD-PV. Horizontal format thermal store for PV pre-heated domestic hot water,03.57 V24 POD-ST. Horizontal format thermal store for thermal pre-heated domestic hot water, with built in controller, pump and over-pressure catch tank,48. Where the household already has a hot water cylinder, the Pod heats the water feed into the cylinder. V24 Pressurised loop kit for Pod-ST. Includes expansion vessel, filling port with flow indicator and check valve 27.0 V243 Combi-diverter valve set. Three valve kit to integrate POD pre-heated water with combi boiler. 227.90 panel You will also need pod V223 First Fix Kit. 20m plug-and-play panel sensor cable with in-line connector block. 25.62 V225 Viridian Solar System Fluid. eady to use, 0 litres. 34.72 Boiler V227 Temperature sensor with 3m cable and J45 connection (suitable for VHL20 or cylinder) 32.80 diverter valve Clearline heating panels are supplied with a factory-fitted temperature sensor, purchase V223 to connect between sensor and controller. An installation of Highline panels requires a V227 sensor plus V223 cable. Purchase additional V223 to extend the cable run in units of 20m. System fluid - allow at least 5 litres for a drainback installation and 0 litres for a pressurised installation with Pod-ST. Where the household has a combi boiler and no hot water cylinder, the Pod heats the water feed to the boiler via a thermostatic by-pass valve. 2

Stelflow Solar Hot Water Cylinders Twin Coil Solar-optimised cylinder with generous dedicated volume to maximise the energy yield. WAS approved stainless steel, dual-coil unvented domestic hot water cylinder. Safety and hot water controls, remote expansion vessel. S50T S80T S20T S250T S300T Stelflow 50T. 50 litre twin coil hot water cylinder, 50 litre dedicated volume. WAS approved, stainless steel unvented cylinder with safety and hot water controls, remote expansion vessel. Diameter 545mm, height 00mm. Stelflow 80T. 80 litre twin coil hot water cylinder, 60 litre dedicted volume. WAS approved, stainless steel unvented cylinder with safety and hot water controls, remote expansion vessel. Diameter 545mm, height 280mm. Stelflow 20T. 20 litre twin coil hot water cylinder, 75 litre dedicted volume. WAS approved, stainless steel unvented cylinder with safety and hot water controls, remote expansion vessel. Diameter 545mm, height 470mm. Stelflow 250T. 250 litre twin coil hot water cylinder, 85 litre dedicted volume. WAS approved, stainless steel unvented cylinder with safety and hot water controls, remote expansion vessel. Diameter 545mm, height 720mm. Stelflow 300T. 300 litre twin coil hot water cylinder, 00 litre dedicted volume. WAS approved, stainless steel unvented cylinder with safety and hot water controls, remote expansion vessel. Diameter 545mm, height 980mm. 870.6 92.35 960.36 997.95,064.73 Solar-Electric Cylinder Solar-optimised electric cylinder with generous dedicated volume to maximise the energy yield. WAS approved stainless steel unvented hot water cylinder. Dual electric immersion heaters plus indirect coil. Safety and hot water controls, remote expansion vessel. S50DS S80DS S20DS S250DS S300DS Stelflow 50DS. 50 litre electric hot water cylinder, 50 litre dedicted volume. WAS approved, stainless steel unvented cylinder with safety and hot water controls, remote expansion vessel. Diameter 545mm, height 00mm. Stelflow 80DS. 80 litre electric hot water cylinder, 60 litre dedicted volume. WAS approved, stainless steel unvented cylinder with safety and hot water controls, remote expansion vessel. Diameter 545mm, height 280mm. Stelflow 20DS. 20 litre electric hot water cylinder, 75 litre dedicted volume. WAS approved, stainless steel unvented cylinder with safety and hot water controls, remote expansion vessel. Diameter 545mm, height 470mm. Stelflow 250DS. 250 litre electric hot water cylinder, 85 litre dedicted volume. WAS approved, stainless steel unvented cylinder with safety and hot water controls, remote expansion vessel. Diameter 545mm, height 720mm. Stelflow 300DS. 300 litre electric hot water cylinder, 00 litre dedicted volume. WAS approved, stainless steel unvented cylinder with safety and hot water controls, remote expansion vessel. Diameter 545mm, height 980mm. 839.30 872.70 895.66 966.62,048.05 Sizing Guide Choose a cylinder where the volume heated by the back-up heat source (e.g. boiler) is greater than or equal to the estimated daily hot water use of the building and the volume is more than 25 litres per square metre of panel installed. Cylinder Size (litres) 50 80 20 250 300 Back-up heated volume (litres) Dedicated Solar volume (litres) 00 20 35 65 200 50 60 75 85 00 Typical sizing based on average occupancy 3

PV Equipment Inverter Installation Kits PV electrical installation kits include: string inverter, DC isolator, two AC isolator switches and warning stickers. Order a generation meter separately. V605 does not include AC isolators, which should be ordered in addition. V605 0.7kWp Inverter Kit for Photovoltaic system (0.5-0.9 kwp). DC isolation switch, label sheet. 48.7 V6-nm.0kWp Electrical Installation Kit for Photovoltaic system (0.83 -.25 kwp). Inverter, isolation switches, label sheet. 447.78 V66-nm.6kWp Electrical Installation Kit for Photovoltaic system (.3-2.0 kwp). Inverter, isolation switches, label sheet. 496.94 V620-nm 2.0kWp Electrical Installation Kit for Photovoltaic system (.7-2.5 kwp). Inverter, isolation switches, label sheet. 559.27 V623-nm 2.5kWp Electrical Installation Kit for Photovoltaic system (2. - 3. kwp). Inverter, isolation switches, label sheet. 649.76 V630-nm 3.0kWp Electrical Installation Kit for Photovoltaic system (2.4-3.6 kwp). Inverter, isolation switches, label sheet. 68.02 V637-nm 4.0kWp Electrical Installation Kit for Photovoltaic system (3.0-4.6 kwp). Inverter, isolation switches, label sheet. 760.50 DC Cables and Accessories DC cables in set lengths with snap-fit connectors make installation on site rapid. Order V6802 link cables for making connecting between close coupled panels PV20 and PV30. Order V680 for making PV6 connections in the roof space. Add a pair of longer cables to connect from each end of the string to the DC isolation switch. V680 DC cable..2m long with push fit couplings. To connect PV6 to adjacent close coupled panel 9.08 V6802 DC cable. 2m long with push fit couplings. To connect PV20 or PV30 to adjacent close coupled panel. 9.44 V6804 DC cable. 4m long with push fit couplings 0.86 V6806 DC cable. 6m long with push fit couplings 2.27 V6808 DC cable. 8m long with push fit couplings 3.70 V680 DC cable. 0m long with push fit couplings 5.4 V682- Single phase electrical energy meter (kwh) 25.52 V684-GSM Single phase electrical energy meter (kwh) with remote logging 65.68 30035 DC Isolation Switch 25A, 000V 2 pole 42.36 300 Dual DC Isolation Switch 6A, 000V 2 pole 58.36 30036 AC Isolation Switch 20A, 440V 4 pole 20.7 Choosing the ight Electrical Kit Panel Type Number of Panels 2 3 4 5 6 7 8 250 Wp 500 Wp 750 Wp 000Wp 250Wp 500Wp 750Wp 2000Wp PV6/250 30079 30079 x 2 V605 V6 V6 V66 V66 V620 330Wp 660Wp 990Wp 320Wp 650Wp 980Wp 230Wp 2640Wp PV20/330 3009 V605 V6 V66 V66 V620 V623 V630 500Wp 000Wp 500Wp 2000Wp 2500Wp 3000Wp 3500Wp 4000Wp PV30/500 V605 V6 V66 V620 V623 V630 V630HF V637 Electrical kits are recommended based on panels having good orientation, between SSE and SSW. Less favourable orientations may be better served with a smaller inverter, please contact us for guidance. 4

String Inverters 30034 Inverter, 0.7kWp (0.5-0.9 kwp). Solis 376.95 30 Inverter, kwp (0.83-.25 kwp). Growatt 000S 369.63 302 Inverter,.5kWp (.3-2.0 kwp). Growatt 500S 48.79 303 Inverter, 2kWp (.7-2.5 kwp). Growatt 2000 483.63 304 Inverter, 3kWp (2.4-3.6 kwp). Growatt 3000 602.87 305 Inverter, 4kWp (3.0-4.6 kwp). Growatt 4000 682.36 Enphase Microinverters 30079 Enphase M25-60-230-S22 Micro Inverter (0.8-0.27 kwp) 53.2 3005 Enphase ENV-230-UK-M Envoy COMMC Gateway - UK Power Cord (Mo 49.73 3006 Enphase ET7-230 Trunk Cable - Portrait or Landscape 32.85 3007 Enphase ET-TEM-0 Branch Terminator 7.78 3008 Enphase ET-SEAL-0 Sealing Cap 5.44 3009 Enphase ET-DISC Disconnect Tool 8.27 Power-One Microinverters 3009 Power-One Aurora Micro Inverter 0.3- OUTD (0.25-0.37 kwp) 74.04 30200 Power-One PVI-CDD Aurora CDD Wireless communication Gateway 262.3 3020 Power-One ACT-B-.05M-4PLUGS AC Trunk Bus.05m 4 plugs 3x4m 06.25 30202 Power-One ACT-PLUGCAP AC Trunk Plug Cap 4.0 30203 Power-One ACT-EXTCAP-FEM-3P AC Trunk Extension Cap Female 3P 4.23 30204 Power-One ACT-BE-FEM-3P AC Trunk Bus Extension Female 3 Pins.25 30205 Power-One ACT-BE-MAL-3P AC Trunk Bus Extension Male 3 Pins.25 30206 Power-One ACT-ULTOOL AC Trunk Unlock Tool 2.9 5

Spares and Accessories oofing VBS Clearline panel fixing bracket - pitched roof without battens 2.77 Bracket for fixing panel to a roof where no battens are used. For example where the panel is fixed to a sarking board. Use 8 per 5 or 20 series panel or 0 per 30 series panel. Solar Thermal V20 eplacement electronic controller without sensors 53.75 V222 5m sensor extension cable with in-line connector block. V223 First Fix Kit. 20m plug-and-play panel sensor cable with in-line connector block. 25.62 V225 Viridian Solar System Fluid. eady to use, 0 litres. Allow 9 litres/v200 and 5 litres/v260. 34.72 V226 In-line connector block for first fix kit 7.94 V227 Temperature sensor with 3m cable and J45 connection (suitable for VHL20 and cylinder) 32.80 V228 Solar panel temperature sensor 22.55 20065 Low energy ErP compliant replacement circulating pump from V200/V260 7.87 V230 8 litre rated expansion vessel 35.79 V23 3 Bar pressure relief valve,, /2 BSP f x 3/4 BSP f 5.65 Cylinders V500 2 litre potable water expansion vessel plus mounting kit and 22mm connection 45.02 V5002 8 litre potable water expansion vessel plus mounting kit and 22mm connection 50.58 V5003 24 litre potable water expansion vessel plus mounting kit and 22mm connection 54.28 V5004 Cylinder high limit thermostat 28.02 V5005 Cylinder dual thermostat 32.46 V5006 Immersion heater, 230V 3kW, Incalloy 34.78 V5007 Inlet control set 4.50 V5008 Two-port motorised valve 55.02 V5009 Tundish 5.87 V500 Temperature and pressure relief valve 3.68 V50 Immersion heater, 230V 3kW, Titanium 68.40 V502 Pressure relief valve, 6 bar, for inlet set 33.89 Delivery D20 6 or 20 series size pallet delivered to mainland UK. 20.00 D30 30 series size pallet delivered to mainland UK. 70.00 DC Single cylinder pallet delivered to mainland UK. 75.00 DC2 Four cylinder pallet delivered to mainland UK. 20.00 Note: each panel sized pallet can accomodate up to (a) 9 panels and flashings (b) 5 panels and flashings plus plumbing kits as follows: D20-8, D30-2, (c) Plumbing kits alone as follows: D20-6, D30-24.. 6

Also Available Communal Solar Kits for communal heating up to very large scale are available, including systems that can distribute heating to individual apartments in a block. Swimming Pool Kits Swimming pool heating is an ideal application for thermal, because the low temperatures mean that the panel is operating at high efficiency for the entire heating season. A range of kits are available to transfer heat into the circulation circuit of the swimming pool, with optional prioritisation of hot water for showers. Viridian Solar Atlas Building 68 Stirling Way Papworth Cambridge UK CB23 3GY info@.co.uk www..co.uk Tel 0480 83 50 Fax 0480 83 83 7