Communication Unit 560CMU05 Data sheet



Similar documents
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Waveguide Access Point WGA631. Product Guide

ABB RTU560A Series CMU & Modules

PCS0100en Persy Control Services B.V. Netherlands

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Manual Serial PCI Cards

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

TK C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router

TK800-Series Industrial GPRS / UMTS / LTE Router

Grid Automation Products. SAM600 Process Bus I/O System Cyber Security Deployment Guideline

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Rack mounted telephone- and leased line modem for industrial applications

Analog signal converters CC-E I/I Current / current isolators

Disturbance Recoder SPCR 8C27. Product Guide

TX OPEN RS232/485 module

Three-phase monitoring relay CM-PFE

Voltage Regulator SPAU 341 C. Product Guide

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

Foxboro Evo Process Automation System

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

DK40 Datasheet & Hardware manual Version 2

Telephone- and leased line modem for industrial applications TD-36

connecdim Gateway G1 Ethernet TCP/IP to DALI

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Cable Pinouts. SRP I/O Module

Universal Serial Bus (USB) to DH-485 Interface Converter

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

XPort Universal Demo Board User Guide

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Industrial Multi-port Serial Cards

AND8336. Design Examples of On Board Dual Supply Voltage Logic Translators. Prepared by: Jim Lepkowski ON Semiconductor.

Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3

LwLVision-USB 2.0. Installation Guide

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

TTL to RS232 Adapter User Guide

Indoor / Outdoor Antenna

A-307. Mobile Data Terminal. Android OS Platform Datasheet

T200, PTP/IEEE 1588 Grandmaster Clock and

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based

Using Xbee in Serial Communication

How To Run An Nport I5000A Device Server

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

Chapter 5 Cubix XP4 Blade Server

Product Brief. R7A-200 Processor Card. Rev 1.0

Overview of Cisco 2600 Series Routers

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

IP4220CZ6. 1. Product profile. Dual USB 2.0 integrated ESD protection. 1.1 General description. 1.2 Features and benefits. 1.

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

WIZ-Embedded WebServer User s Manual (Ver. 1.0)

THE EASY WAY EASY SCRIPT FUNCTION

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Advanced Data Capture and Control Systems

Products. CM-i586 Highlights. Página Web 1 de 5. file://c:\documents and Settings\Daniel\Os meus documentos\humanoid\material_o...

Communicate and view data from meters with one simple device

M3 Single-Slot Cradle. User Guide. Cradle Model: A-1CR-U R00, A-1CR-U00D-040-R00, A-1CR-US R00, A-1CR-U0ED-110-R00

ORION TELECOM NETWORKS INC. T1

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Alcatel-Lucent OmniPCX Enterprise Communication Server RMAB

LBNP RS-232/485/422 serial device server. User manual

ACR880 GPRS Portable Smart Card Terminal

Remote Terminal Unit RTU560. System Description Release 6.2

STRATO LED Drivers 70W, Single output

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

SyncLink GT2/GT4 Serial Adapter

MCR1900 Media Converter 19-Slot Chassis

SBC6245 Single Board Computer

PESDxU1UT series. 1. Product profile. Ultra low capacitance ESD protection diode in SOT23 package. 1.1 General description. 1.

Series Six Plus Programmable Controller

ProCurve Switch 8000m (J4110A) and Switch 8000m

USER GUIDE Programming Adapter Cable for Fujitsu Flash Microcontroller- F²MC-16LX/FR Family Fujitsu Microelectronics America, Inc.

2100 POS System User Guide

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Huawei NE5000E 400Gbps Flexible Line Processing Unit

MVME162P2. VME Embedded Controller with Two IP Slots

udrive-usd-g1 Embedded DOS micro-drive Module Data Sheet

Data sheet SLIO CPU 015 (015-CEFPR00)

Allen-Bradley/Rockwell

DCS Data and communication server

1 Port RS232 Serial over IP Device Server

User manual Compact Web PLC WP240 series IEC-line

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

ewon COSY 141 Installation Guide

CPB. Doc. N MO-0279-ING MODBUS/PROFIBUS DP CONVERTER TYPE CPB. Microener - Copyright 2010 Date Rev. 0

38 Series - Relay interface modules A

CompactLogix Power Supplies Specifications

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

Introduction. Features. Industrial 2 ports RS-422/485 with Surge PCI-Express Low Profile Serial Card

QuickSpecs. HP Compaq t5525 Thin Client. Overview

IntesisBox Modbus Server Fidelio IP

Transcription:

RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory Application The 560CMU05 communication unit is one of the CMU modules of the RTU560 product line. The essential tasks are: Managing and controlling of the I/O modules via the interface to the serial I/O bus. Reading Process events from the input modules. Send commands to the output modules. Communicating with control systems and local HMI systems via the serial interfaces (RS232) and the Ethernet 10/100BaseT interfaces. Communication with Sub-RTU s, IED s or multimeter devices via the interfaces (RS485) and the Ethernet interfaces. Managing the time base for the RTU560 station and synchronizing the I/O modules. Handling the dialog between RTU560 and Web-Browser via the LAN interfaces. Within the RTU560 racks the board occupies two slots. The communication unit is able to handle Ethernet-, UART- and all non UART character based communication protocols. Figure 1: Block diagram 560CMU05 Characteristics SLC CPA, CPB RS232C, RS485 or SPB The two microprocessors are the essential hardware parts of the module, which share themselves in the tasks: MPU: 32 Bit Main Processing Unit SLC: 8 Bit Serial Line Controller One task of the SLC is to work as master for the SPB I/O bus (serial peripheral bus). In addition the SLC is the time base for the I/O modules and does the periodical time synchronization of the I/O modules. Depending on the configuration also serial protocols can be handled via the SLC. The MPU is responsible for the other tasks. The MPU handles the absolute time and date for the RTU. The real time clock 560RTC0x can be used for the time reference or the time may be set and synchronized from the central system via the serial lines or via the Ethernet LAN interface. RTU560 synchronizes it-

self to the time references supplied by 560RTC0x. The time information of the 560RTC0x is provided to the 560CMU05 on the backplane of the sub-rack. System relevant configuration files are stored in the non-volatile flash memory card in order to guarantee a valid system configuration after Power on Reset (PoR). The communication unit provides the following interfaces: Communication Port 1 and 2 (CP1 & CP2): serial interfaces according RS232C or RS485 with connectors. Communication Port A and B (CPA & CPB): serial interfaces according RS232C or RS485 with connectors. If configured as SPB I/O bus the interface CPB is connected to the front side and parallel to the backplane connector. Ethernet Interface 1 and 2 (E1 & E2) Ethernet interface 10/100BaseT with connector. 2 1KGT 150 619 V004 1 - Communication Unit 560CMU05

Technical data Serial interfaces CPA and CPA In addition to the RTU500 series general technical data, the following applies: Signal lines GND TxD RxD E2/102 D1/103 D2/104 Main Processing Unit MPU RTS CTS S2/105 M2/106 CPU ELAN520 @ 133 MHz DTR S1.2/108 (incorporating an Intel 586TM class DCD M5/109 32 bit processor) 64 MByte RS485: Serial Line Controller SLC CPU 80C251 600 bit/s - 38.4 kbit/s 32 kbyte Ethernet interface E1 and E2 Dual ported 16 kbyte CompactFlash card IEEE 802.3, 10/100BaseT CompactFlash card slot CF-Typ I (36,4 mm 42,8 mm 3,3 mm) Capacity 128 MByte Current consumption for power supplied via RTU560 backplane 5 V DC 1060 ma 24 V DC Serial interfaces CP1 and CP2 RS232C or RS485 Signaling by LEDs ERR (red) ON: RTU in error state Flashing: RTU in warning state For more details see RTU500 series RS232C: Function Description Signal lines 50 bit/s - 38.4 kbit/s GND E2/102 TxD D1/103 RxD D2/104 Tx (green) Rx (green) Transmit data on serial communication ports CP Receive data on serial communication ports CP RTS S2/105 A (green) Activity on Ethernet interface E CTS DTR M2/106 S1.2/108 L (green) Link up on Ethernet interface E RS485: DCD M5/109 Mechanical layout Dimensions 160 mm x 100 mm, 3HE euro card format 50 bit/s - 38.4 kbit/s 8R (40 mm) front panel Housing type Printed circuit board Mounting for mounting in RTU560 racks Serial interfaces CPA and CPA Weight 0.3 kg RS232C or RS485 Connection type RS232C: 600 bit/s - 38.4 kbit/s RTU560 backplane connector 48 pole type F DIN 41612 Immunity test Electrostatic discharge IEC 61000-4-2 8 kv air (level 3) / 4 kv contact (level 2) Communication Unit 560CMU05-1KGT 150 619 V004 1 3

Immunity test Radiated Radio-Frequency Electromagnetic Field IEC 61000-4-3 Electrical Fast Transient / Burst IEC 61000-4-4 Surge IEC 61000-4-5 Conducted Disturbances, induced by Radio-Frequency Fields IEC 61000-4-6 10 V/m (level 3) 2 kv (level 3) 2 kv (level 3) 10 V (level 3) Environmental conditions Nominal operating temperature range: EN 60068-2-1, -2-2, -2-14 Relative humidity EN 60068-2-30-25 C... 70 C 5... 95 % (non condensing) Ordering information 560CMU05 R0002 1KGT012700R0002 4 1KGT 150 619 V004 1 - Communication Unit 560CMU05

ABB AG Power Systems Division P.O. Box 10 03 51 68128 Mannheim, Germany www.abb.com/substationautomation Note: The specifications, data, design or other information contained in this document (the Brochure ) - together: the Information - shall only be for information purposes and shall in no respect be binding. The Brochure does not claim to be exhaustive. Technical data in the Information are only approximate figures. We reserve the right at any time to make technical changes or modify the contents of this document without prior notice. The user shall be solely responsible for the use of any application example or information described within this document. The described examples and solutions are examples only and do not represent any comprehensive or complete solution. The user shall determine at its sole discretion, or as the case may be, customize, program or add value to the ABB products including software by creating solutions for the end customer and to assess whether and to what extent the products are suitable and need to be adjusted or customized. This product is designed to be connected to and to communicate information and data via a network interface. It is the users sole responsibility to provide and continuously ensure a secure connection between the product and users or end customers network or any other network (as the case may be). The user shall establish and maintain any appropriate measures (such as but not limited to the installation of firewalls, application of authentication measures, encryption of data, installation of anti-virus programs, etc) to protect the product, the network, its system and the interface against any kind of security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB AG is not liable for any damages and/or losses related to such security breaches, any unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB AG shall be under no warranty whatsoever whether express or implied and assumes no responsibility for the information contained in this document or for any errors that may appear in this document. ABB AG's liability under or in connection with this Brochure or the files included within the Brochure, irrespective of the legal ground towards any person or entity, to which the Brochure has been made available, in view of any damages including costs or losses shall be excluded. In particular ABB AG shall in no event be liable for any indirect, consequential or special damages, such as but not limited to loss of profit, loss of production, loss of revenue, loss of data, loss of use, loss of earnings, cost of capital or cost connected with an interruption of business or operation, third party claims. The exclusion of liability shall not apply in the case of intention or gross negligence. The present declaration shall be governed by and construed in accordance with the laws of Switzerland under exclusion of its conflict of laws rules and of the Vienna Convention on the International Sale of Goods (CISG). ABB AG reserves all rights in particular copyrights and other intellectual property rights. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in part - is not permitted without the prior written consent of ABB AG. Copyright ABB 2014 All rights reserved Communication Unit 560CMU05-1KGT 150 619 V004 1 5