Certificate of Conformity



Similar documents
ALTAIR 5X Multigas Detector Bid Specification

FGM 160 ATEX EC type examination certificate

Lockout Specification BW Clip Maintenance-free single gas detector

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Wolflite Safety Handlamp H-251E

Technical Data. Dimensions

Power Management: SCM

Inductive slot sensor

EX 2000/EX 2000 C/ GD 2000/GDP

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Technical Data. Dimensions

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

An easy and flexible way to do gas detection.

Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation


Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Boxes Series 8146

2.12. page Products for Explosion hazardous Environment

550-xx mm LED CBI. Circuit Board Indicator Square Back Housing, Quad Block x x x 4

Terminal Box. Specifications TNCN

DATA SHEET SURFACE-MOUNT CERAMIC MULTILAYER CAPACITORS General Purpose & High Capacitance Class 2, X7R

Plug and Socket Devices SolConeX 16 A Series 8570

SELECTION GUIDE. Nominal Input

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC

Specification. Li-ion Rechargeable Battery

Aluminum Electrolytic Capacitors Axial Miniature, Long-Life

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

EGSTON Standard E2xFxWx 12W

INTERNATIONAL STANDARD

Mini USB and USB 2.0-IP67 Connector System

ALTAIR Family Gas Detectors A Tough Bunch

Inductive sensor NI10-M18-Y1X-H1141

SIL Resistor Network. Resistors. Electrical. Environmental. L Series. Thick Film Low Profile SIP Conformal Coated Resistor Networks RoHS Compliant

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Optocoupler, Photodarlington Output, Dual Channel, SOIC-8 Package

Plug and Socket Devices CES 63 A Series 8579

GasAlertMax XT II H 2 O 2 LEL

EVERLIGHT ELECTRONICS CO.,LTD. Technical Data Sheet High Power LED 1W (Preliminary)

Optocoupler, Phototransistor Output, with Base Connection, 300 V BV CEO

KEYCHAIN SYNC CHARGE CABLE

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

INTERNATIONAL ATOMIC ENERGY AGENCY INSTRUMENTATION UNIT SMD (SURFACE MOUNTED DEVICES) REPAIR S. WIERZBINSKI FEBRUARY 1999

Build a Voltage and Current Peak Detector

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Aluminum Electrolytic Capacitors Radial Miniature, Low Impedance, High Vibration Capability

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Optocoupler, Phototransistor Output, with Base Connection

Optocoupler, Phototransistor Output, with Base Connection

handbook, 2 columns handbook, halfpage 085 CS

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Alkaline Manganese (Mercury free) IEC: LR03; JIS: AM-4; ANSI: AAA; MN2400; Micro chemical system: Zn / KOH-H 2 O / MnO 2

TC50 High Precision Power Thin Film chip resistors (RoHS compliant Halogen Free) Size 1206, 0805, 0603

SPEC NO: DSAJ8637 REV NO: V.6B DATE: JUL/01/2016 PAGE: 1 OF 5 APPROVED:

Optocoupler, Phototransistor Output, with Base Connection

2002 IS Catalog. Page

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate

Single-Gas Detector. Long-term solution. h Class I, Div. 1, Gr. A, B, C, D NCL-EN

Capacitive Prox E2K-X

Technical data sheet TDS0070

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

High Speed Infrared Emitting Diode, 940 nm, GaAlAs, MQW

Low Current SMD LED PLCC-2

LITHIUM BATTERY CR123A SPECIFICATION

Triple Waveband Infra-Red Flame Detection

EVERLIGHT ELECTRONICS CO.,LTD.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Handheld portable appliance testers

7 Lighting Technology

4N25 Phototransistor Optocoupler General Purpose Type

Aluminum Electrolytic Capacitors Power Economic Printed Wiring

Features. Applications. Truth Table. Close

HL-A-3528H308W-S1-13. Description. Applications. Recommended Soldering. Package Dimensions

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

3mm Photodiode,T-1 PD204-6C/L3

SMS : Surface Mount, 0201 Zero Bias Silicon Schottky Detector Diode

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Hand-held thermometer Model CTH7000

AC and Pulse Film Foil Capacitors KP Radial Potted Type

Preset Counter signo 721

DATA SHEET LEAD FREE CHIP RESISTORS RC_P series ±0.5%, ±1%, ±5% Sizes 0100/0201/0402/0603/0805/ 1206/1210/1218/2010/2512

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

1 Form A Solid State Relay

David O Brien, CMP Products (David.OBrien@cmp-products.com)

type V46, solenoid or pneumatic operated

Problem / Solution. The problem:

Multi-Function Ground

Low Current SMD LED PLCC-2

Transcription:

Applicant: Mine Safety Appliances Co. 1000 Cranberry Woods Drive Cranberry Township PA 16066 United States of America Electrical Apparatus: Altair 4 / 4X Diffusion Multi-gas Detector Type of Protection: Ex ia s Zone 0 Marking Code: Altair 4: Altair 4X: Ex ia s Zone 0 I IP54 (Ta = 50 C) Ex ia s Zone 0 IIC T4 IP54 (Ta = 50 C) Ex ia I IP67 Ex ia mb d IIC T4 IP67 - When Combustible XCell Sensor is installed Ex ia IIC T4 IP67 - When Combustible XCell Sensor is not installed. Manufacturer: Manufacturing Location(s): Mine Safety Appliances Co. 1000 Cranberry Woods Drive Cranberry Township PA 16066 United States of America As above The EPEE certification database located at http://www.anzex.com.au shows the validity of this Certificate. Certificate issued by: TestSafe Australia 919 Londonderry Road, Londonderry NSW 2753 Australia Phone: +61 2 4724 4900 Fax: +61 2 4724 4999 http://www.testsafe.com.au www.jas-anz.org/register EPF019_17 Page 1 of 6

This certificate is granted subject to the conditions as set out in Standards Australia/Standards New Zealand Miscellaneous Publication MP87.1:2008. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0:2004 Electrical apparatus for explosive atmospheres Part 0: General requirement IEC 60079-11:2006 Explosive atmospheres Part 11: Equipment protection by intrinsic safety i AS 1826:2006 Electrical equipment for explosive gas atmospheres Special Protection Type of protection s IEC 60529:2001 Degrees of protection provided by enclosure (IP Code) This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standard(s) listed above. ASSESSMENT & TEST REPORTS: The equipment listed has successfully met the assessment and test requirements as recorded in: Test Report and Issuing Body: 33787, TestSafe Australia Quality Assessment Report and Issuing Body: FR/INE/QAR08.0011/03, INERIS File Reference: 2012/012031 Ujen Singh 02/08/2012 Signed for and on behalf of issuing body Date of Issue Quality & Certification Manager Position This certificate is not transferable and remains the property of the issuing body and must be returned in the event of it being revoked or not renewed. EPF019_17 Page 2 of 6

EQUIPMENT: Schedule The Altair 4 Multi-gas Detector is a 4 Gas instrument. It contains one dual toxic electrochemical cell, one combustible cell, and one oxygen electrochemical cell. It measures 75 mm by 120 mm by 35 mm. The body is made of ABS and the overmoulding is conductive, of the same material as the Altair single gas detector. The display is a mono-colour LCD (Philips PCF8533 series). The rechargeable battery is Lithium polymer (Sony battery) one cell. The battery is encapsulated in a plastic container with soft polyurethane based encapsulant. CONDITIONS OF CERTIFICATION: It is a condition of safe use that the input parameters for the battery charger, which may be connected only in a safe area, are shown below: Maximum Charger Voltage U m Maximum Charger Current I m 6.7 V 1.7 A DOCUMENTS: SK3098-1038 21 4-Gas Detector, 4GD, Altair4, TestSafe 0 2007-11-29 SK3098-1059 1 Label, AS/NZS and IEC Approvals, Altair4 0 2008-03-06 EPF019_17 Page 3 of 6

Schedule of Variations Variations Permitted by Issue 1: Adding an alternate case overmuold material RTP 2099E X 118617 B (Black) to the apparatus. This change has been assessed in Test Report 30309. Condition of Certification Relating to Issue 1: 1. The previous conditions are still applicable. Drawings Relating to Issue 1: SK3098-1038 11 of 21 4-Gas Detector, 4GD, Altair4, TestSafe 0A 2008-05-05 Variations Permitted by Issue 2: The drawing SK3098-1038 Rev.0 is replaced by drawing SK3098-1038 Rev.1. The changes are: 1. Sheet 1, 2 & 5: Added illustration of missing non-protective resistor R94 (unmarked) in the combustible associated schematic. (Note: This information was accidentally left out on this schematic, but, the part was previously already on p.c. board artwork drawing sheet 19 which has remained unchanged, thus spacing analysis still remains unaffected). 2. Sheet 3: Added maximum capacitance and minimum voltage rating of C12 in the BATT SAFETY SCHEMATIC (Note: This information was previously already noted on sheet 12). 3. Sheet 4: Added R94, its specifications and its analysis of missing non-protective resistor R94 to the COMB CIRCUIT schematic. 4. Sheet 11: Corrected ratings of 5 resistors to 0.125W for a typographical error. (Note: The correct values were previously already noted in the analysis contained within preceding sheets). 5. Sheet 11: Corrected dimension of minimum wall (non-floor) thickness of the battery tray/carrier from 0.86 mm to 0.50 mm. (Note: The correct dimension was previously already noted on sheet 20). 6. Sheet 11: Corrected revision of printed circuit board artwork from revision 2 to revision 4. (Note: The correct artwork revision was previously already noted on sheets 14 through 19). 7. Sheet 11: Added the calibration cap anti-static material type. 8. Sheet 12: Corrected quantities of components from 3 to 5 in two places for typographical errors. (Note: There were previously already noted 5 parts for Q1, Q3, Q4, Q12, Q13 and D2, D6, D7, D12, D13). EPF019_17 Page 4 of 6

9. Sheet 12: Added missing non-protective resistor R94. (Note: As in 1. above, this information was accidentally left out on this schematic, but, the part was previously already on p.c. board artwork drawing which has remained unchanged, thus spacing analysis still remains unaffected). 10. Sheet 21: Added optional double-sided adhesive tape between optional clip and instrument. 11. Sheet 21: Added illustration for optional calibration cup. 12. Sheet 11: Added RoHS compliant Littelfuse 0466.200 0.2A SMT alternate fuse having the same UL and CSA approval file numbers as the previous 0433.200 fuse. 13. Sheet 11: Added alternate static dissipative overmold material RTP2099 EX 118617 B BLK/BLK in two places and removed "IP 64 Minimum" in five places. These changes have been assessed in Test Report 30699. Condition of Certification Relating to Issue 2: The previous conditions are still applicable. Drawings Relating to Issue 2: SK3098-1038 21 4-Gas Detector, 4GD, Altair4, TestSafe 1 2008-07-18 Variations Permitted by Issue 3: Added new model Altair 4X to the certificate. Altair 4X is identical to Altair 4 only Altair 4X uses XCell sensors and has a different sensor circuit. Altair 4X has been assessed in Test Report 32207. Quality Assessment Report has been updated Condition of Certification Relating to Issue 3: The previous conditions are still applicable. EPF019_17 Page 5 of 6

Drawings Relating to Issue 3: SK3098-1134 22 Altair4X, TestSafe, ANZEx 0 2010-07-21 SK3098-1157 1 Label, AS/NZS and IEC Approvals, Altair4X 0 2010-09-01 SK3098-1085 24 Approval, XCell Ex Combustible Sensor, FTZU - 2010-03-30 Variations Permitted by Issue 4: The drawing SK3098-1134 Rev.0 is replaced by drawing SK3098-1134 Rev.1. The changes are: 1. The IR Transceiver (component designator U1) Sharp GP2W0110YP0F is being replaced by a similar device Vishay TFBS4650. 2. Associated capacitor C6 decreased in nominal capacitance from 1.0 µf to 0.1µF. 3. Protective resistor R7 36.5 Ω nominal, ±1% tolerance, 1 W rating, 2512 SMD has changed to 100 Ω nominal, ±5% tolerance, 1 W rating, 2512SMD. However, in the design requirement drawing, it is still described as 36.135 with no change. 4. A label with battery capacity and other information was added to the internal battery pack. 5. Corrections (no design changes) were made in regards to infallible via designations (circle-i) and colours used to describe the plated through holes for connecting to the gas sensors sockets as shown on new sheets 15, 16, 17, 18, 19, & 20. These changes have been assessed in Test Report 33787. Quality Assessment Report has been updated Condition of Certification Relating to Issue 4: The previous conditions are still applicable. Drawings Relating to Issue 4: SK3098-1134 22 Altair4X, TestSafe, AS/NZS 1 2012-06-06 EPF019_17 Page 6 of 6