Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)



Similar documents
Technicaldata General

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM9 10(24VDC) Article No.:

Type: DILM32 10(24V50HZ) Article No.:

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

The complete range of consumer switchboards and switchgear

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

5SV Residual Current Protective Devices

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

8146/5 Series Breaker Panelboards

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Product Guide. Cable-in / cable-out miniature circuit breakers and supplementary protectors

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Three-phase monitoring relay CM-PFE

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Bimetallic Overload Relay Specifications

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

The power distribution board that sets new standards

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

R.C.C.B. s two-pole LEXIC

Standard-compliant switchgear and controlgear production

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Circuit Breakers. Next Generation of Protection Capabilities

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Safety technique. Emergency stop module BO 5988 safemaster

Manual motor starter MS116

SURGE PROTECTIVE DEVICES

RY2 miniature industrial relays

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Operating Manual UWAPS-TINY Series

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Actuator-Sensor-Interface

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Low Voltage Switchboards The Best Technical Solution for Your Ship

Power Supplies 3. SDN-P DIN Rail Series

Relés e Contatores de Estado Sólido SIRIUS

Bulletin 1489 Circuit Breakers. Selection Guide

Residual Current Protective Devices

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

RM4TG20 three-phase network control relay RM4-T - range V

Quick Connect. quick - simple - efficient.

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Pluggable interface relays CR-P Pcb relays

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Easy Multifunctional Safe

Thermistor motor protection

Securing your electrical installations Prisma,

Unified requirements for systems with voltages above 1 kv up to 15 kv

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

MOTOR PROTECTIVE DEVICES

Manual Motor Starter MS 116 up to 16 A Technical Data

Thermal-Magnetic Circuit Breaker M1-..

Catalog. Modular DIN rail components Installation contactors

DS 600. A contact free flux gate based current measurement sensor 600A rms

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

E-STOP relays, safety gate monitors

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

SIVACON The Versatile Low-Voltage Switchboard

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

MNS is Switchgear System Technical Overview

Technical catalogue. Modular DIN rail components Installation contactors

PHOENIX CONTACT Features

Preset Counter signo 721

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

FP2 Relay. The Best Relaytion

FAQs-Main switchboard design criteria

Redundancy Module QUINT-DIODE/40

Low Voltage Products. Switches Automatic Transfer Switches

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

Automation Solutions. LÜTZE LCOS empty housing for Industrial Automation

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

Plug and Socket Devices CES 63 A Series 8579

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Series 8146/5-V37 and Series 8150/5-V37

IEC & 2 standard. The reference for safe and reliable LV switchboards

Transcription:

Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic D Application Switchgear for industrial and commercial applications Rated current I n A 6 Rated switching capacity acc. to IEC/EN 60947-2 ka 15 Product range FAZ Technicaldata Electrical Standards IEC/EN 60947-2 IEC/EN 60898 Rated operational voltage U e V U e V AC 230/400 V DC 48 (per pole) Rated switching capacity acc. to IEC/EN 60947-2 ka 15 Operational switching capacity ka 7.5 Characteristic B, C, D Max. back-up fuse A gl/gg 125 Selectivity Class 3 Lifespan Operations > 10000 Direction of incoming supply as required Mechanical Standard front dimension mm 45 Enclosure height mm 80 Terminal protection Finger and back-of-hand proof to BGV A2 Mounting width per pole mm 17.5 Mounting IEC/EN 60715 top-hat rail Degree of Protection IP20, IP40 (when fitted) Terminals top and bottom Twin-purpose terminals Terminal capacities mm 2 mm 2 1 x 25 mm 2 2 x 10 Thickness of busbar material mm 0.8 2 Mounting position As required DesignverificationasperIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 6 Heat dissipation per pole, current-dependent P vid W 0 Equipment heat dissipation, current-dependent P vid W 2.9 Static heat dissipation, non-current-dependent P vs W 0 Heat dissipation capacity P diss W 0 Operating ambient temperature min. C -25 12/19/2015 278777 - HPL-ED2015 V18.0 EN 1 / 8

Operating ambient temperature max. C 75 linear, per +1 C, results in a 0.5% reduction of current carrying capacity IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM6.0 Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042) Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss8.1-27-14-19-01 [AAB905011]) Release characteristic D Number of poles (total) 2 Number of protected poles 2 Nominal rated current A 6 Nominal rated voltage V 400 Rated short-circuit breaking capacity Icn EN 60898 at 230 V ka 10 Rated short-circuit breaking capacity Icn EN 60898 at 400 V ka 10 Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V ka 15 Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V ka 15 Voltage type AC Current limiting class 3 Frequency Hz 50-60 Concurrently switching N-neutral No Suitable for flush-mounted installation No Over voltage category 3 Pollution degree 2 Width in number of modular spacings 2 Built-in depth mm 70.5 Additional equipment possible Yes Degree of protection (IP) IP20 12/19/2015 278777 - HPL-ED2015 V18.0 EN 2 / 8

Approvals Product Standards IEC/EN 60947-2; IEC/EN 60898; UL 1077; CSA-C22.2 No. 235; CE marking UL File No. E177451 UL Category Control No. QVNU2, QVNU8 CSA File No. 204453 CSA Class No. 3215-30 North America Certification UL recognized, CSA certified Conditions of Acceptability Supplementary Protector only Suitable for Branch Circuits; not as BCPD Current Limiting Circuit-Breaker No Max. Voltage Rating 480Y/277 VAC; 96 VDC Degree of Protection IEC: IP20; UL/CSA Type: - Characteristics 12/19/2015 278777 - HPL-ED2015 V18.0 EN 3 / 8

Let-through energy I 2 t According to IEC/EN 60898 12/19/2015 278777 - HPL-ED2015 V18.0 EN 4 / 8

12/19/2015 278777 - HPL-ED2015 V18.0 EN 5 / 8

12/19/2015 278777 - HPL-ED2015 V18.0 EN 6 / 8

Tripping characteristic at 30 C: B, C, D to IEC/EN 60898 12/19/2015 278777 - HPL-ED2015 V18.0 EN 7 / 8

Dimensions Additionalproductinformation(links) AWA1220-1755Circiut-breaker AWA1220-1755 Circiut-breaker ftp://ftp.moeller.net/documentation/awa_instructions/17550701.pdf 12/19/2015 Eaton Industries GmbH http://www.eaton.eu 12/2015 by Eaton Industries GmbH 278777 - HPL-ED2015 V18.0 EN 8 / 8