Cylindrical Proximity Sensor



Similar documents
Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Cylindrical Proximity Sensor

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

How To Read A Pipe From A Sensor

Proximity Sensor with All-stainless Housing

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

Capacitive Prox E2K-X

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Absolute Rotary Encoder E6CP

SPST-NO SPDT DPST-NO DPDT

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Color Mark Sensor with Red or Green LED E3S-VS

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

Liquid Leakage Sensor Amplifier

Cross-beam scanning system to detect slim objects. 100 mm in

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

Multifunction Digital Timer

Surface Mounting Relay

Incremental Rotary Encoder E6B2

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Magnetic proximity switches

General-purpose Relay

Smart DeviceNet Remote I/O Terminals

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder. Accessories (Order Separately)

Solid-State Timer H3G

SPST-NO SPDT DPST-NO DPDT

Inductive sensor NI10-M18-Y1X-H1141

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Type Supply voltage Output Connection Sensing range Standard target Timer function Part number Polarized VDC NPN/PNP Pre-leaded 500 mm to 10 m

Model Number Structure

Inductive sensors. Compact, fast, reliable. Edition 2013

Model Number Structure

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Cable Plug acc. to DIN EN , Form A

Inductive Proximity Sensors

RY2 miniature industrial relays

U-shaped Micro Photoelectric Sensor

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Socket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY

Adjustment functions for both span and shift have been incorporated

How To Power A Schen

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Universal Voltage Terminal Photoelectric E3JM

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

CQM1-SF200/CS1W-SF200

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

pre-wired E3FC-TN11 2M *1 E3FC-TP11 2M *1

Solid State Relays with Built-in Current Transformer

NX safety stand-alone

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Fiber-Optic Photoelectric Sensor

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

3 Port Solenoid Valve

intelligent solutions

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Count input Display Time range h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black

LCD Readout Digital Pressure Switch

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

E2A Single Sensing Distance

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Preset Counter signo 721

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Transcription:

Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models with a Yellow Indicator New series of TL-X2C1-GE models with improved performance over the previous TL-X-E models. Also, in addition to the, the new series of E2E/E2E2 models are available. Ideal for a variety of applications. With a metal connector that can be tightened securely and a cord protector. With an easy-to-see yellow indicator, deeper mounting holes, and tightening flats for wrenches. The new series of models includes M8 plug-in connector models. Note: Detailed information is available for the replacement of conventional models. Ask your OMRON representative for a copy of OMRON s /E2E/E2E2 Conversion Guide. Ordering Information DC 3-wire/Pre-wired Shield Size Sensing Output Part number distance configuration NPN PNP Shielded M8 1.5 mm NO -X1R5C1 -X1R5B1 NC -X1R5C2 -X1R5B2 M12 2mm NO -X2C1 -X2B1 NC -X2C2 -X2B2 M18 5mm NO -X5C1 -X5B1 NC -X5C2 -X5B2 M30 10 mm NO -X10C1 -X10B1 NC -X10C2 -X10B2 Unshielded M8 2mm NO -X2MC1 -X2MB1 NC -X2MC2 -X2MB2 M12 5mm NO -X5MC1 -X5MB1 NC -X5MC2 -X5MB2 M18 10 mm NO -X10MC1 -X10MB1 NC -X10MC2 -X10MB2 M30 18 mm NO -X18MC1 -X18MB1 NC -X18MC2 -X18MB2 1

DC 3-wire/M12 Plug-in Shield Size Sensing Output Part number distance configuration NPN PNP Shielded M8 1.5 mm NO E 2E G -X 1R5C1-M 1 -X1R5B1-M1 NC -X1R5C2-M1 -X1R5B2-M1 M12 2mm NO -X2C1-M1 -X2B1-M1 NC -X2C2-M1 -X2B2-M1 M18 5mm NO -X5C1-M1 -X5B1-M1 NC -X5C2-M1 -X5B2-M1 M30 10 mm NO -X10C1-M1 -X10B1-M1 NC -X10C2-M1 -X10B2-M1 Unshielded M8 2mm NO -X2MC1-M1 -X2MB1-M1 NC -X2MC2-M1 -X2MB2-M1 M12 5mm NO -X5MC1-M1 -X5MB1-M1 NC -X5MC2-M1 -X5MB2-M1 M18 10 mm NO -X10MC1-M1 -X10MB1-M1 NC -X10MC2-M1 -X10MB2-M1 M30 18 mm NO -X18MC1-M1 -X18MB1-M1 NC -X18MC2-M1 -X18MB2-M1 DC 3-wire/M8 Plug-in Shield Size Sensing Output Part number distance configuration NPN PNP Shielded M8 1.5 mm NO -X1R5C1-M3 -X1R5B1-M3 Unshielded M8 2mm NO -X2MC1-M3 -X2MB1-M3 2

Specifications Ratings/Characteristics -XjCj/Bj DC 3-wire Models Item -X1R5 Cj/Bj -X2M Cj/Bj -X2 Cj/Bj -X5M Cj/Bj -X5 Cj/Bj -X10M Cj/Bj Size M8 M12 M18 M30 -X10 Cj/Bj -X18M Cj/Bj Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Sensing distance Supply voltage (operating voltage range) (see note) Current consumption Sensing object 1.5 mm!10% 2mm!10% 2mm!10% 5mm!10% 5mm!10% 10 mm!10% 10 mm!10% 18 mm!10% 12 to 24 VDC, ripple (p-p): 10% max., (10 to 40 VDC) 13 ma max. Magnetic metals (refer to Engineering Data for non-magnetic metals) Setting distance 0to1.2mm 0to1.6mm 0to1.6mm 0to4.0mm 0to4.0mm 0to8.0mm 0to8.0mm 0to14.0mm Standard object (mild steel) 8x8x1mm 12 x 12 x 1mm 12 x 12 x 1mm 15 x 15 x 1mm 18 x 18 x 1mm 30 x 30 x 1mm 30 x 30 x 1mm 54 x 54 x 1mm Differential travel 10% max. of sensing distance Response frequency 2.0 khz 0.8 khz 1.5 khz 0.4 khz 0.6 khz 0.2 khz 0.4 khz 0.1 khz Operation (with C1/B1 models: ON sensing object approaching) C2/B2 models: OFF Control output (switching capacity) Circuit protection Indicator Ambient temperature Ambient humidity Operating: 35% to 95% 200 ma max. 200 ma max. (300 ma max. at 55"C or less) NPN or PNP open collector Reverse connection protection, surge absorber, load short-circuit protection (yellow LED) Operating: --40"C to70"c (withnoicing) Temperature influence!15% max. of sensing distance at 23"C in temperature range of --40"C to 70"C!10% max. of sensing distance at 23"C in temperature range of --25"C to 70"C Voltage influence!1% max. of sensing distance in rated voltage range!15% Residual voltage M8: 2.0 V max. (under load current of 200 ma with cable length of 2 m) M12 to M30: 2.0 V max. (under load current of 300 ma with cable length of 2 m) Insulation resistance 50 M# min. (at 500 VDC) between current carry parts and case Dielectric strength Vibration resistance 1,000 VAC for 1 min between current carry parts and case Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z directions Destruction: Shock resistance Destruction: 500 m/s 2 (approx. 50G) for 10 times each in X, Y, and Z directions 1,000 m/s 2 (approx. 50G) for 10 times each in X, Y, and Z directions 500 m/s 2 (approx. 50G) for E2E-X5M Enclosure rating IEC IP67 Weight Pre-wired Approx. 45 g Approx. 120 g Approx. 160 g Approx. 270 g Connector --- Approx. 25 g Approx. 45 g Approx. 125 g Approx. 124 g Material Case Stainless steel Brass Sensing PBT surface Note: models with an M18 or M30 connector operate at a non-smoothed, all-wave rectified, mean voltage range of 24 VDC!20%. 3

Engineering Data Operating Range (Typical) Shielded Models -XjCj/Bj -XjCj/Bj Sensing distance X (mm) E2Ej-X2j Sensing distance X (mm) E2Ej-X10j E2Ej-X1R5j E2Ej-X5j Y (mm) Y (mm) Unshielded Models -XjMCj/Bj -XjMCj/Bj Sensing distance X (mm) E2Ej-X5Mj Sensing distance X (mm) E2Ej-X18Mj E2Ej-X2Mj E2Ej-X10Mj Y (mm) Y (mm) 4

Sensing Distance vs. Sensing Object (Typical) -X1R5Cj/Bj -X2Cj/Bj -X5Cj/Bj t=1mm t=1mm Sensing distance (mm) Brass Aluminum Mild steel Stainless steel (SUS304) Sensing distance (mm) Mild steel Stainless steel (SUS304) t=1mm Brass Aluminum Sensing distance (mm) Mild steel Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) Side length of sensing object d (mm) Side length of sensing object d (mm) -X10Cj/Bj -X2MCj/Bj -X5MCj/Bj t=1mm Sensing distance (mm) t=1mm Mild steel Stainless steel (SUS304) Brass Aluminum Sensing distance (mm) t=1mm Mild steel Stainless steel (SUS304) Brass Copper Aluminum Sensing distance (mm) Mild steel Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) Side length of sensing object d (mm) Side length of sensing object d (mm) -X10MCj/Bj -X18MCj/Bj t=1mm Mild steel Sensing distance (mm) t=1mm Stainless steel (SUS304) Brass Aluminum Sensing distance (mm) Mild steel Stainless steel (SUS304) Aluminum Brass Side length of sensing object d (mm) Side length of sensing object d (mm) 5

Operation Output Circuits -XjCj NPN Open Collector Output Brown -XjBj PNP Open Collector Output Brown 100 # Main circuit Black Output Main circuit Black Blue 0V 100 # Blue 0V Operating Chart -XjCj/Bj NPN/PNP Open Collector Output Sensing object Red indicator Control output Yes No Lit Not lit ON OFF 6

Dimensions Note: All units are in millimeters unless otherwise indicated. Type Part number DC 3-wire Pre-wired Shielded M8 -X1R5Cj/Bj 1 M12 -X2Cj/Bj 3 M18 -X5Cj/Bj 5 M30 -X10Cj/Bj 7 Unshielded M8 -X2MCj/Bj 2 M12 -X5MCj/Bj 4 M18 -X10MCj/Bj 6 M30 -X18MCj/Bj 8 Connector (M12) Shielded M8 -X1R5Cj-M1/Bj-M1 9 M12 -X2Cj-M1/Bj-M1 11 M18 -X5Cj-M1/Bj-M1 13 M30 -X10Cj-M1/Bj-M1 15 Unshielded M8 -X2MCj-M1/Bj-M1 10 M12 -X5MCj-M1/Bj-M1 12 M18 -X10MCj-M1/Bj-M1 14 M30 -X18MC1-M1/B1-M1 16 Connector (M8) Shielded M8 -X1R5C1-M3/B1-M3 17 Unshielded -X2MC1-M3/B1-M3 18 Figure no. 7

Pre-wired Models (Shielded) Fig. 1 : -X1R5Cj/Bj Pre-wired Models (Unshielded) Fig. 2 : -X2MCj/Bj 15 dia. 15 dia. Operation M8 x 1 indicator Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 3 cores 6.1 dia. M8 x 1 Operation indicator Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 3 cores Fig. 3 : -X2Cj/Bj Fig. 4 : -X5MCj/Bj 21 dia. 21 dia. Operation indicator Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 3 cores 9dia. Operation indicator Two clamping nut Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 3 cores Fig. 5 : -X5Cj/Bj Fig. 6 : -X10MCj/Bj 29 dia. 29 dia. Operation M18 x 1 indicator Round vinyl-insulated cable 6 dia. (0.12 dia. x 45), 3 cores 14.8 dia. M18 x 1 Operation indicator Round vinyl-insulated cable 6 dia. (0.12 dia. x 45), 3cores Fig. 7 : -X10Cj/Bj Fig. 8 : -X18MCj/Bj 42 dia. 42 dia. M30 x 1.5 Round vinyl-insulated cable 6 dia. (0.12 dia. x 45), 3 cores 26.8 dia. M30 x 1.5 Operation indicator Two clamping nut Round vinyl-insulated cable 6 dia. (0.12 dia. x 45), 3 cores 8

Connector Models (Shielded) Connector Models (Unshielded) Fig. 9 : -X1R5Cj-M1/Bj-M1 Fig. 10 : -X2MCj-M1/Bj-M1 15 dia. 15 dia. M8 x 1 6.1 dia. M8 x 1 Fig. 11 : -X2Cj-M1/Bj-M1 Fig. 12 : -X5MCj-M1/Bj-M1 21 dia. 21 dia. 9dia. Fig. 13 : -X5Cj-M1/Bj-M1 Fig. 14 : -X10MCj-M1/Bj-M1 29 dia. 29 dia. M18 x 1 14.8 dia. M18 x 1 Fig. 15 : -X10Cj-M1/Bj-M1 Fig. 16 : -X18MCj-M1/Bj-M1 42 dia. 42 dia. 26.8 dia. M30 x 1.5 M30 x 1.5 9

M8 Connector Models (Shielded) M8 Connector Models (Unshielded) Fig. 17 : -X1R5C1-M3/B1-M3 Fig. 18 : -X2MC1-M3/B1-M3 15 dia. M8 x 1 15 dia. M8 x 1 M8 x 1 6.1 dia. M8 x 1 Mounting Holes F Dimensions 4 dia. M5 5.4 dia. M8 M12 M18 M30 F (mm) 4.2 +0.5 / 0 dia. 5.5 +0.5 / 0 dia. 5.7 +0.5 / 0 dia. 8.5 +0.5 / 0 dia. 12.5 +0.5 / 0 dia. 18.5 +0.5 / 0 dia. 30.5 +0.5 / 0 dia. 10

Installation Connection -XjCj DC 3-wire Models Brown Black Blue 24 VDC Pin Arrangement -XjCj/Bj-M1/M3 Connector Output configuration Applicable models M12 NO -XjC1-M1 Pin arrangement Note: Terminal 2 is not used. -XjB1-M1 Note: Terminal 2 is not used. NC -XjC2-M1 Note: Terminal 4 is not used. -XjB2-M1 Note: Terminal 4 is not used. M8 NO -XjC1-M3 Note: Terminal 2 is not used. -XjB1-M3 Note: Terminal 2 is not used. 11

Precautions Mounting Do not tighten the nut with excessive force. A washer must be used with the nut. Shielded Model Unshielded Model Note: The table below shows the tightening torques for part A and part B nuts. In the previous examples, the nut is on the sensor head side (part B) and hence the tightening torque for part B applies. If this nut is in part A, the tightening torque for part A applies instead. Type Part A Part B Length Torque Torque M8 Shielded 9mm 9NS m 12 N S m Unshielded 3mm (91 kgf S (120 kgf S cm) cm) M12 30 N S m (310 kgf S cm) M18 M30 70 N S m (710 kgf S cm) 180 N S m (1,800 kgf S cm) Part B Part A Part B Part A Effects of Surrounding Metal When mounting the within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the sensor. ddia. -XjCjj j -XjBj DC 3-wire Type Item M8 M12 M18 M30 Shielded l 0mm 0mm 0mm 0mm d 8mm 12 mm 18 mm 30 mm D 0mm 0mm 0mm 0mm m 4.5 mm 8mm 20 mm 40 mm n 12 mm 18 mm 27 mm 45 mm Unshielded l 6mm 15 mm 22 mm 30 mm d 24 mm 40 mm 55 mm 90 mm D 6mm 15 mm 22 mm 30 mm m 8mm 20 mm 40 mm 70 mm n 24 mm 36 mm 54 mm 90 mm Relationship between Screw Sizes and Models Type Part number M8 Shielded -X1R5Cj/Bj Unshielded -X2MCj/Bj M12 Shielded -X2Cj/Bj Unshielded -X5MCj/Bj M18 Shielded -X5Cj/Bj Unshielded -X10MCj/Bj M30 Shielded -X10Cj/Bj Unshielded -X18MCj/Bj 12

Mutual Interference When installing two or more Sensors face to face or side by side, ensure that the minimum distances given in the following table are maintained. A B -XjCjj j -XjBj DC 3-wire Type Item M8 M12 M18 M30 Shielded A 20 mm 30 mm 50 mm 100 mm B 15 mm 20 mm 35 mm 70 mm Unshielded A 80 mm 120 mm 200 mm 300 mm B 60 mm 100 mm 110 mm 200 mm! Caution Item Power supply Do not impose an excessive voltage on the, otherwise it may explode or burn. Do not impose 100 VAC on any DC model, otherwise it may explode or burn. Sensor Brown Blue Black Incorrect Examples short-circuit Do not short-circuit the load, or the may explode or burn. The s short-circuit protection function is valid if the polarity of the supply voltage imposed is correct and within the rated voltage range. Brown Sensor Blue Black Incorrect Wiring Be sure to wire the and load correctly, otherwise it may explode or burn. Brown Sensor Blue Black Incorrect Sensor Brown Black Blue Incorrect Connectionwithnoload Make sure to connect a proper load to the in operation, otherwise it may explode or burn. Sensor Brown Blue Incorrect Correct Use Installation Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Power OFF The Proximity Sensor may output a pulse signal when it is turned off. Therefore, it is recommended to turn off the load before turning off the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Sensing Object Metal Coating: The sensing distances of the Proximity Sensor vary with the metal coating on sensing objects. Wiring High-tension Lines Wiring through Metal Conduit If there is a power or high-tension line near the cord of the Proximity 13

Sensor, wire the cord through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Environment Water Resistivity Cord Tractive Force Do not pull cords with the tractive forces exceeding the following. Do not use the Proximity Sensor underwater, outdoors, or in the rain. Diameter Tractive force Operating Environment 4dia.max. 30 N max. Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so 4 dia. min. 50 N max. that its reliability and life expectancy can be maintained. Although Mounting The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its water-resistivity. the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). Connection type Method Description AND (serial connection) OR (parallel connection) Correct Correct The Sensors connected together must satisfy the following conditions. i L +(N--1)xi Upper-limit of control output of each Sensor V S -- N x V R operating voltage N: No. of Sensors V R : Residual voltage of each Sensor V S : Supply voltage i: Current consumption of the Sensor i L : current If the MY Relay, which operates at 24 VDC, is used as a load for example, a maximum of two Proximity Sensors can be connected to the load. A minimum of three Sensors with current outputs can be connected in parallel. The number of Sensors connected in parallel varies with the Proximity Sensor model. 14

15

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. D060-E1-1 OMRON Corporation Systems Components Division H.Q. 28th Fl., Crystal Tower Bldg. 1-2-27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 06-949-6012 Fax: 06-949-6021 In the interest of product improvement, specifications are subject to change without notice. Printed in Japan 0796-2M (0796) a 16