Flashover. Newsletter by Vincent Dunn-July 2000



Similar documents
December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference?

NEW SCIENCE FIRE SAFETY ARTICLE INNOVATING FIRE ATTACK TACTICS SUMMER 2013 UL.COM/NEWSCIENCE

SOUTH LYON FIRE DEPARTMENT Manual of Procedures 404

Fire and Rescue Service Operational Guidance. GRA 5.8 flashover, backdraught and fire gas ignitions

July, Aug, Sept, 2005, Newsletter. By VINCENT DUNN, DEPUTY CHIEF, FDNY. (RET) 50 Ways Firefighters Live

Fire Safety Risk Assessment Checklist for Residential Care Premises

FIRE SAFETY FOR OFFICE WORKERS

Workplace Fire Safety

Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases

Firefighter Review. Instructor Guide

On-Line Fire Extinguisher Training

Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include:

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

FIRE AND LIFE SAFETY TRAINING

EMERGENCY EVACUATION PLAN FOR LIFE AND FIRE SAFETY

Fire Development and Fire Behavior Indicators

Natural Gas Emergencies

IN CASE OF EMERGENCY. Emergency Telephone Number 112

FIRE EXTINGUISHER TRAINING

FIREFIGHTER SAFETY. Stay safe during substation fires

LESSON PLAN FIRE PREVENTION AND SAFETY

JOB DESCRIPTION. *-- Drives and operates ambulance or other apparatus as assigned and/or operates as a member of medic engine or medic truck company.

St. John s University Fire Safety Plan

LESSON PLAN 1. Fire Science. Key Terms and Concepts. ash chemical reaction combustion Consumer Product Safety Commission endothermic exothermic

Presented by: Rich Perry Marsh Risk Consulting

VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO USE

Fire Fighter Survival

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Hotel Fire Safety for staff

BROADCAST MESSAGE FROM THE SACRAMENTO FIRE MARSHALL

exit routes and fire protection

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection. OSHA Office of Training and Education 1

FIRE PREVENTION PLAN

DCSS (ACB) Data Center Fire Suppression Procedures

OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety

Sample Written Program. For. Flammable Liquids

RESIDENTS FIRE SAFETY INFORMATION PACK

Class A - Wood, paper, cloth, trash, plastics Solid combustible materials that are not metals. (Class A fires generally leave an Ash.

WEEKLY SAFETY MEETING All Euramax Subsidiaries WELDING SAFETY / HOT WORK SAFETY. Safety Meeting Contents. Meeting Notice.

Decree of the Ministry of the Environment. on fire safety of garages

Sable Altura Fire Department

St. John s University

Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers

Chippewa County Courthouse Security Emergency Procedures. Dial FIRE POLICE AMBULANCE

NFPA Hazard Class: * Physical Form: Solid. Health: 0 (Least) * Appearance: Yellow Flammability: 1 (Slight)

RESIDENTS FIRE SAFETY INFORMATION PACK

Smoke Alarms Save Lives!

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

HAZARD COMMUNICATION: NEW LABEL ELEMENTS AND SAFETY DATA SHEET (SDS) FORMAT

WHAT YOU NEED TO KNOW ABOUT INSURING A HOME WITH FIRE SPRINKLERS

CAREER OPPORTUNITY Brunswick Fire Department

CITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY

Director, National Institute for Occupational Safety and Health. California Fatality Assessment and Control Evaluation (CA/FACE) Program

RESIDENTS FIRE SAFETY INFORMATION PACK

GENERIC RISK ASSESSMENT 3.6 FIGHTING FIRES - USING POSITIVE PRESSURE VENTILATION

Material Safety Data Sheet

Living Arts School of Communication Arts Emergency Preparedness Plan. - Table of Contents -

ADMINISTRATIVE SERVICES MANUAL

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

Flammable Liquids Storage

Use Of Residential Fire Sprinklers In New Housing Projects

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Flammable Liquids Storage

Truck Company Operations

Fire Risk Assessment Safety Checklist

Emergency Response Guide

AIRCRAFT RESCUE AND FIRE FIGHTING GUIDE REVISION 0. AA Flight Safety Department.4601 Hwy 360; MD 849 GSWFA.Fort Worth Texas Phone

Notes. Material 1. Appropriate Flammable Liquids

Residential Fire Safety Policies

FIRE SAFETY HANDBOOK

Emergency Procedures

Using Class B Combustibles During Live Fire Training

EMERGENCY PROCEDURES

EMERGENCY PROCEDURES

FETC Services Training E-Blast. Snow Loaded Roof Considerations

TSA Conference Reducing the Risk of Fire to the Vulnerable Person through Telecare. London Fire Brigade

EMERGENCY ACTION PLAN. for

How To Write A Fire Risk Assessment

General Fire Code Requirements Within Commercial Tenant Spaces

Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

Safety Storage Cabinets

Consumer Product Safety Commission Smoke Alarms Why, Where, and Which CPSC Pub. 559

Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances

Portable Fire Extinguisher Presentation

Example risk assessment for a motor vehicle mechanical repair workshop

MATERIAL SAFETY DATA SHEET

FIRE DETECTION AND ALARM SYSTEMS

Define Fire Stream. A stream of water, or other extinguishing agent, after it leaves the fire hose and nozzle until it reaches the desired point

SOUTH DAKOTA FIRE SERVICE TRAINING PRACTICAL SKILLS TEST

FIRE SAFETY ONLINE TRAINING

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

Mesa Campus. Annual Fire Safety Report on Student Housing

Transcription:

Newsletter by Vincent Dunn-July 2000 Flashover Flashover! It is the most dangerous time of a fire. When the room bursts into flame, flashover has occurred. The scientific definition of flashover states it is caused by the radiation feedback of heat. Heat from the growing fire is absorbed into the upper walls and contents of the room, heating up the combustible gases and furnishings to their auto-ignition temperature. This build up of heat in the room triggers flashover. Flashover signals several major changes in a fire and is the end of an effective search and rescue in a room; It means the death of any person trapped in the blazing room - either civilians or firefighters. It signals the end of using a portable extinguisher to extinguish the fire; an attack hose-line is required after flashover occurs. It signals the end of the growth stage and that the fire is in the second stage of combustion - the fully developed stage. Finally, flashover signals the change from a contents to a structure fire. This is the beginning of the collapse danger. When operating at a fire, Chiefs and firefighters want to delay flashover inside a burning room. By delaying flashover you can "buy" several minutes which may be critical. For example, you may want to delay flashover to make a search and rescue of the burning room or allow a firefighter to go above a fire to make a rescue of a trapped victim. Or, you may want to delay flashover to gain several minutes when there is a delay in the placement of the first attack hose-line. Three ways to delay flashover: venting: By venting windows of a burning room you release the build up of heat in the room. This slows down flashover in addition to improving visibility in a smoke-filled room. not venting- by not venting and instead closing the door to the burning room, you can also delay flashover. By not venting, you starve the fire of oxygen, which slows down the combustion rate, which slows down the build up of heat in the room. (See chart on page 24 for when to vent and when not to vent.) This may be done when there is a delay in stretching a hose-line and all persons are out of the burning room. portable extinguisher: The discharge of a portable extinguisher can cool the heat down in a burning room temporarily and delay flashover. To avoid getting trapped by flashover, firefighters must know the warning signs of flashover. Warning signs of flashover There are two warning signs, which may signal the danger of flashover: heat mixed with smoke and "rollover." Flashover, Vincent Dunn 1 800 231-3388 www.vincentdunn.com

Heat: When heat mixes with smoke, it forces a firefighter to crouch down on hands and knees to enter a room to perform search and rescue. This must be considered a warning sign that flashover may occur. Heat is the triggering event for flashover. If the heat in the smoke filled room causes us to crouch down near the floor, we must consider the danger of flashover. Rollover: Rollover is defined, as sporadic flashes of flame mixed with smoke at ceiling level. Rollover is caused by heated combustible gases in smoke, which ignites into flashes of flame when mixed with oxygen in the air. Rollover precedes flashover. Rollover is another warning sign of flashover, which may be seen in the smoke coming out of the tops of doorways or window openings of burning rooms before flashover occurs. When searching for the location of a fire and there is no discernible heat in the smoke or signs of rollover, firefighters may enter and proceed for some distance into a fire area. However, If one of these warning signs is discovered and a flashover danger exists, defensive search procedures must be used by firefighters. Standard tactics and procedures must be curtailed and defensive search and rescue procedures substituted when there is a danger of flashover. Defensive search procedures: There are two defensive search procedures that can reduce the risk of death and injury from flashover: At a doorway: A firefighter should check behind the door for the victim, then enter the hallway or room not more than five feet, sweep the floor, look for unconscious persons, call out and listen for a response. If no response is forthcoming, close the door and wait for the hose-line. As the attack hoseline advances, conduct a search and rescue behind the line, searching room and space outward from the hose-line. At a window: When climbing a ladder placed at a window and the window breaks from either the heat of the fire or because it is opened by the firefighters at the top of the ladder, and smoke and signs of rollover are seen in the smoke, the firefighter should not enter the burning window. Instead the firefighter should crouch down below the heat and sweep the area below the windowsill with a tool. In some instances a person may collapse at the window and fall right below the sill. If a victim is found, a firefighter on the ladder might be able to crouch below the heated smoke and flashes of flames mixed with smoke coming out the window and pull the victim to safety on the ladder. Flashover, Vincent Dunn 1 800 231-3388 2

Point of no return After a flashover occurs, firefighters may have past the point of no return. The point of no return is a distance inside a burning room beyond which a searching firefighter will not escape and will not reach the door or window entered. How far inside a burning room can a firefighter be and still escape back out the door alive and not suffer serious bums after a flashover occurs? How far into the burning room that appears about to flashover should a firefighter go? Five feet is the point of no return after the room explodes into a flashover. We can figure this distance out by putting together several facts. For example, tests conducted in 1960 in California discovered that fire temperatures of 280'-320' F cause intense pain and damage to exposed skin. Also the average temperature in a room that flashes over is 1000' to 1500' F. And, time and motion tests in the Handbook of Fire Protection reveal that the average person moves 2-1/2-feet per second when walking. Now, the question is how long can a firefighter take 1000'-1500' F on the neck, ears, wrists and any other exposed portion of the body? I say two seconds. If there is 1000' F flame in a burning room that has just flashed over and a firefighter is five feet inside the room, and crawls back to the doorway at 2-1/2-feet per second, he will feel 1000'-1500' F on exposed portions of skin not covered by fire gear for two seconds. If you say you can enter 10 feet into a room about to flashover and it does, and you try to escape you will experience 1000' -1500' F on the exposed portions of your body for four seconds. Think about it. Lessons learned Firefighters should know the definition of flashover. They should know the warning signs of this danger heat in smoke and rollover. Also firefighters must know how to delay flashover - a room bursting into flames. And most important for firefighters' safety and survival, they must know defensive firefighting procedures - how to search and stay alive. Flashover, Vincent Dunn 1 800 231-3388 3

Firefighting questions True or False Flashover is the most dangerous phase of a fireís growth. According to fire protection engineers flashover is caused by which one of the following? Radiation heat Radiation feedback heat Conduction heat None of the above 3.Flashover signals major changes at a fire, which one of the following is not one of them? The end of the search and entry The end of using a portable extinguisher to fully extinguish the blaze The end of the growth stage of fire The end of the collapse danger 4.Which one of the following is not a method used by firefighters to delay flashover? Venting to release heat Not venting to starve the fire of oxygen and thus slow down heat generation Use a portable extinguisher on the fire to cool it down Remove combustible from the fire area 5.Which one of the following is not a warning sign of flashover? Heat in smoke Rollover-flashes of flame mixed with smoke Black smoke Flashover, Vincent Dunn 1 800 231-3388 4

Answers: Flashover Newsletter by Vincent Dunn-July 2000 Answers: 1-True; 2-B; 3-D; 4-D; 5-C. Flashover, Vincent Dunn 1 800 231-3388 5