CCM.M-K3.1 comparison / 50 kg Mass



Similar documents
Calibration Certificate

Estimates of Uncertainty of the Calibration of Balances

User checks and maintenance of laboratory balances

OIML R RECOMMENDATION. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION , E 2. Weights of classes E 1 , F 2 , M 1 2 , M 1

EURAMET 1197 SUPPLEMENTARY BILATERAL COMPARISON OF HYDRAULIC GAUGE PRESSURE STANDARDS UP TO 50 MPa

Weight Calibration ComparatorPac TM Simple Calibration Efficient Workflow Reliable Results

Gravimetric determination of pipette errors

S Davidson, M Perkin, M Buckley

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Guidelines on the Calibration of Static Torque Measuring Devices

Key comparison CCM.M-K1 MEASURAND : Mass NOMINAL VALUE : 1 kg. x (rep) i :

Certificate of Calibration No

Balance Calibration A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance

Report of the Spectral Irradiance Comparison EURAMET.PR-K1.a.1 between MIKES (Finland) and NIMT (Thailand)

Training Material for Balances (1) Prepared by R&D Division 1. Marketing Department A&D Company, Limited

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Testing Your Laboratory Balance

How To Use A Corona Mdi 110

Activity P13: Buoyant Force (Force Sensor)

Determining Measurement Uncertainty for Dimensional Measurements

FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER

Activity P13: Buoyant Force (Force Sensor)

Case study Realistic and best uncertainties with humidity instruments

WEIGHTS AND MASS STANDARDS

Oilfield Services Measurement Solutions

Using Equotip Hardness Test Blocks Abstract 1. Introduction 2. Verification of Leeb hardness testers according to standards

The Analytical Balance

LAB14 EDITION 4 November 2006

Measurement and Calibration

Specific volume and absorption properties

Estimating Weighing Uncertainty From Balance Data Sheet Specifications

THE DETERMINATION OF THE MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT OF MATERIALS USING THE VIBRATORY HAMMER COMPACTION

Classic Balances NewClassic ML Precise results Compact and portable Affordable for all budgets

Chapter 16. Mensuration of Cylinder

INVESTIGATION OF FALLING BALL VISCOMETRY AND ITS ACCURACY GROUP R1 Evelyn Chou, Julia Glaser, Bella Goyal, Sherri Wykosky

Balance Accuracy. FlexiWeigh

Vandal-proof keypad series

GENERAL SCIENCE LABORATORY 1110L Lab Experiment 5 THE SPRING CONSTANT

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Address for Correspondence

Torque Key Comparison CCM.T-K1.3

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

Physics 40 Lab 1: Tests of Newton s Second Law

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Measuring equipment in a laboratory.

S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS. Final text for addition to The International Pharmacopoeia

Three Methods for Calculating the Buoyant Force Gleue: Physics

Pipette Calibration. Accurate Pipettes Day by Day. Ensure Operational Reliability With Service XXL. For more information

Experiment #4 Sugar in Soft Drinks and Fruit Juices. Laboratory Overview CHEM August 2010

CHAPTER 15 FORCE, MASS AND ACCELERATION

DENSITY MEASURING SYSTEMS

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards

Chapter 11. h = 5m. = mgh mv Iω 2. E f. = E i. v = 4 3 g(h h) = m / s2 (8m 5m) = 6.26m / s. ω = v r = 6.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

CHAPTER 6 WEAR TESTING MEASUREMENT

Negative gauge pressure comparison

ANSWER KEY. Work and Machines

Eco Green Labs India Pvt. Ltd., Ground Floor, Plot No. 100, New Sidco Industrial Estate, Srinagar, Hosur, Tamil Nadu

Physics Lab Report Guidelines

Establishment of the Gas Flow Calibration Facility at CSIR-NPL, India

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

PHYSICAL QUANTITIES AND UNITS

Test Report issued under the responsibility of:

Intercomparison in gauge pressure 0 25 MPa

Test equipment for temperature and its reduction

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Heating oven with mechanical control

Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory

Florida Method of Test for TESTING OF GROUND TIRE RUBBER Designation: FM 5-559

Check-list for auditors. Audit visit at candidate registered laboratories

Welcome to Physics 40!

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

The Determination of Uncertainties in Charpy Impact Testing

Freezers - Ultrafreezers. Platilab & Irilab Series

MATLAB AS A PROTOTYPING TOOL FOR HYDRONIC NETWORKS BALANCING

NIST Calibration Services for Liquid Volume NIST Special Publication

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Installation Detailed installation instructions are provided which should be strictly followed.

Kinetic Friction. Experiment #13

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration.

NITP 6.1 to 6.4 National Instrument Test Procedures for Non-automatic Weighing Instruments

Apr 17, 2000 LAB MANUAL

Operating Principle of the Sample Positioning Flaps

E X P E R I M E N T 8

Physics 121 Sample Common Exam 3 NOTE: ANSWERS ARE ON PAGE 6. Instructions: 1. In the formula F = qvxb:

INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999

Rotational Motion: Moment of Inertia

R&S ZCxxx Millimeter-Wave Converters Specifications

Sound Power Measurement

METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD

Calibration Service Selection Guide

(Equation 1) to determine the cord s characteristics. Hooke s Law represents the

75 Ω Transmission System

HAMBURG WHEEL-TRACKING TEST

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale


Transcription:

CCM.M-K3.1 comparison / 50 kg Mass The 7 th of April 2010 G. MANN - T. MADEC - P.A. MEURY Laboratoire Commun de Métrologie LNE-CNAM Abstract This comparison is a subsequent to the CCM.M-K3 comparison performed in 2001-2002 and published in 2005 [1]. This comparison is between the CEM (Spain) as participating laboratory and the LNE (France) as pilot laboratory. The aim of this comparison was to compare the results obtained by each laboratory when calibrating the same two 50 kg stainless steel mass standards, one provided by CEM and one by LNE. 1. Introduction The purpose of this document is to define the organisation of the subsequent comparison and to provide instructions on the transport of the transfer standards and the reporting of the measurement results. It is defined by applying the guidelines for CIPM key comparisons (appendix F to the MRA ). 2. Organisation Two travelling 50 kg standards circulated between the pilot and the participant of the comparison, one belongs to LCM and the other one belongs to CEM. The LCM standard was used to perform the loop 1. It was calibrated by LCM before and after the CEM calibration. The CEM standard was used to perform the loop 2. It was calibrated by the CEM before and after the LCM calibration. 2.1 Participating laboratories 2.1.1 Pilot Laboratory Country Laboratoire Commun de Métrologie LNE-CNAM LCM France 2.1.2 Participant Laboratory Country Centro Español de Metrología CEM Spain CCM.M-K3.1 comparison draft B 7 April 2010 page 1/10

2.2 Comparison scheme Two travelling 50 kg standards circulated among the participants. The travel of the standards was set up in a circular form with two loops: - Loop 1, using the first travelling standard (January 2009 to July 2009) from France to Spain, then return to France, - Loop 2, using the second travelling standard (January 2009 to November 2009) from Spain to France, then return to Spain. Comparison schedule: Dates January 09 January 09 February May 09 June 09 July 09 November 09 Activity By each laboratory, calibration of one s own travelling standard transfer CEM travelling standard from Spain to France then transfer LCM travelling standard from France to Spain By each laboratory, calibration of travelling standard of the other laboratory transfer LCM travelling standard from Spain to France then transfer CEM travelling standard from France to Spain New calibration of one s own travelling standard by LCM New calibration of one s own travelling standard by CEM Table 1 - Comparison schedule CCM.M-K3.1 comparison draft B 7 April 2010 page 2/10

2.3 Characteristics of the Mass standards Loop 1: travelling standard 6 The LCM travelling standard, used in loop 1, is in stainless steel X 18 M 25 W and was manufactured by the ZWIEBEL company. It is cylinder with a circular fork groove. This standard is called six comma (6 ) and identified by a serial number engraved on the top plane face. A handling fork was supplied with this standard. Parameter Value expanded uncertainty (95% coverage) Density at 20 C 7 987.2 kg.m -3 1.4 kg.m -3 Magnetic susceptibility 3.30 x10-3 0.60 x10-3 Height 224.8 mm 0.20 mm Diameter 190.0 mm 0.20 mm Height of centre of gravity above base 110.9 mm 0.40 mm Table 2: Characteristics of the LCM standard Picture 1 - the LCM travelling standard (n 6 ) CCM.M-K3.1 comparison draft B 7 April 2010 page 3/10

Loop 2 : travelling standard MP9 The CEM travelling standard, used in loop 2, is identified by a serial number engraved on the top plane face: number MP9. It has the following features: Parameter Value expanded uncertainty (95% coverage) Density at 20 C 8053.1 kg.m -3 1,5 kg.m -3 Height 306.9 mm 0.2 mm Diameter 185.0 mm 0.2 mm Height of centre of gravity above base 117.8 mm 2.0 mm Table 3 : Characteristics of the CEM standard Picture 2 - the CEM travelling standard (n MP9) CCM.M-K3.1 comparison draft B 7 April 2010 page 4/10

2.4 Travelling conditions Staff from CEM was in charged of standards transportation between institutes. The travelling standards were examined on receipt and any scratches or other marks, if any, were recorded on the Travelling standard visual inspection form. This form was sent by fax or e-mail to LCM within 24 hours after the inspection. 2.5 Measurement 2.5.1 Cleaning No cleaning is applied to the standards. If necessary a light brushing was made with a soft-haired sable brush. 2.5.2 Ambient conditions The measurements were made under ambient conditions of air. The parameters contributing to air density were recorded for each weighing and the air density was calculated using the CIPM 2007 formula. 2.5.3 Weighing procedure The laboratory applied its own weighing procedure. 3. Results of the comparison 3.1 Stability of the travelling mass standards Each laboratory compared its one s own travelling standards before and after calibration made by the other laboratory. The results of these comparisons are given in tables 4a and 4b below. travelling standard 6 LCM travelling standard MP9 CEM Date value Date value Jan 2009 + 18.50 mg Jan 2009-80.50 mg July 2009 + 16.80 mg Nov 2009-82.06 mg Table 4a: Deviations d of the travelling standards from the nominal value CCM.M-K3.1 comparison draft B 7 April 2010 page 5/10

travelling standard 6 travelling standard MP9 d u( d) d u( d) - 1.70 mg 0.92 mg - 1.56 mg 0.84 mg Table 4b: drift d of the travelling standards during the comparison and standard uncertainty u( d) of this drift These results show that the mass of the two travelling standards did not change significantly during the comparison. 3.2 Results reported by the CEM Table 5 shows the results and combined uncertainties as given by the CEM. Reported results of the participant (m: mass of the travelling standard - m 0 ; nominal value of the standard) are as follows: u (m-m 0 ) standard uncertainty reported. Loop 1 Date Laboratory m-m 0 u(m-m 0 ) Travelling Standard 6 May 09 CEM + 17.64 mg 3.96 mg Loop 2 Date Laboratory m-m 0 u c Travelling Standard MP9 January 09 November 09 CEM - 80.50 mg 3.96 mg CEM - 82.06 mg 3.96 mg Table 5 - Results reported by the CEM CCM.M-K3.1 comparison draft B 7 April 2010 page 6/10

3.3 Reference value coming from CCM.M-K3 comparison The two travelling standards (n 6 and n MP9) were calibrated each by two mass standards (n 9 and n 7) used in the previous CCM.M-K3 comparison [1]. According to this comparison, the reference value mc ref and its expanded uncertainty are as follows: Reference CCM.M-K3 reference standard Value Expanded uncertainty (95% coverage) n 9 + 42.65 mg 2.10 mg n 7 + 51.25 mg 2.10 mg Table 6 - Reference values coming from CCM.M-K3 comparison 3.4 Reference value of the travelling standards Results of the LCM, coming from the calibration, are given in table 7. The reference value of n 6 travelling standard is the mean value of calibration before and after CEM (see table 4a). Reference Travelling standard Value Expanded uncertainty (95% coverage) Calibrated vs n 6 + 17.6 mg 3.0 mg n 9 and n 7 n MP9-84.1 mg 3.0 mg Table 7 - Reference value of the travelling standards CCM.M-K3.1 comparison draft B 7 April 2010 page 7/10

Graph 1 Calibration results of 50 kg n 6 Graph 2 Calibration results of 50 kg MP9 3.5 Degree of equivalence of the CEM The degree of equivalence deq A of the CEM laboratory (noted A) is equal to the difference mc A mc ref between the participant s corrected value and the reference value. For the 6 travelling standard, mc ref is the mean value of the calibration before and after CEM. For the MP9 travelling standard, mc A is the mean value of the calibration before and after LCM. The uncertainty of the degree of equivalence u(deq A ) takes into account the uncertainty components coming from the result given by the laboratory u(m A ), the CCM.M-K3.1 comparison draft B 7 April 2010 page 8/10

correction applied to this result u d, the drift of the travelling standard d (with the assumption of a rectangular distribution) and the uncertainty u(mc ref ) of the reference value : u 2 2 d deq u m u d A A 12 2 u 2 mc ref (1) Table below gives the degree of equivalence deq A of each laboratory with the assigned expanded uncertainty U(deq) (95% coverage). (mg) reference value calibration by n 7 and n 9 from CCM.M-K3 comparison deq A U(deq A ) MET6-0.08 mg 8.70 mg MP9-2.83 mg 8.40 mg Table 8 - Degree of equivalence of the CEM Graph 3 degree of equivalence of the CEM CCM.M-K3.1 comparison draft B 7 April 2010 page 9/10

4. Mass Comparator used by participant Laboratory Manufacturer Type Resolution Standard deviation (1) Degree of freedom CEM Mettler Toledo AX64004 0,1 mg 0.4 mg (1) Standard deviation of repeatability or reproducibility of the result of one comparison process Table 9 - Mass Comparator used by CEM 5. References [1] CCM.M-K3: Metrologia, 2005, 42, Tech. Suppl., 07003 CCM.M-K3.1 comparison draft B 7 April 2010 page 10/10