Fan Convector Technical Specifications January 2006 Rev A



Similar documents
IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Select Radiators Installation Guide

The space saving solution.

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

Low Profile Unit Cooler

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

REGULATORS 175/153 Series

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Cast Iron Radiator Heating Capacity Guide

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Installation Instructions - For the following HEATER model numbers: 200, 300, 400, 500 Series Hydronic Heaters

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

Light Duty Commercial Electric Water Heater

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Glossary of Heating, Ventilation and Air Conditioning Terms

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Electric Flow Boiler

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

MAC-120HE-01 Air-Cooled Chiller

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

High efficiency, cast-iron gas boiler

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

3Aftermarket Systems. Air Conditioners and Kombos Heater/Pressurizer System Matrix Aftermarket System Requirements...

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Explosion-Proof Electric Unit Heaters

Overview of Baseboard Heating

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

KONRAD. Hybrid Fancoil Series

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

NAVIEN AMERICA INC FITCH AVENUE

Stainless Steel Single and Dual Circulation Kits

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

ECOCIAT. Domestic hot water heat recovery unit

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

E2 Series Electric Furnaces

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Installation & Maintenance Instructions

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

Your safety and the safety of others are very important.

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

Water Pump Replacement

FOXAIR 60/50 ALL MODELS

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Installation Manual CLIFC Fan & Coil Variable Speed

Cooktop Low-Profile Ventilation Hoods

Boston, Venice, Kodiak. Enviro Wood Fireplace Inserts

STOVES & INSERTS PELLET. PELLET STOVES & INSERTS. woo

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

LOBOY 16 AIR CONDITIONERS

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Installation Instructions

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Technical Data. Installation

Condensing Boiler Efficiency

Electric Water Heater

SECTION HEAT PUMPS

Commercial Portable Air Conditioners

Cooling Capacity CFM in. w.c. (125 Pa)

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

SunMaxx Solar Filling Station Operating Instructions

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Commercial Semi-Instantaneous Water Heaters

1. Geo Vertical 2. Geo Horizontal

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

300 Series PA Pump and Cooler Assemblies

Commercial Gas Furnace Upflow

Nest Learning Thermostat Installation Guide. Installation step-by-step

Local Dealer:

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Chilled Water Fan Coil Unit

PRESSURE REDUCING CONTROL VALVE

Transcription:

Boost Off Normal Off Fan Convector Technical Specifications Boost Normal January 2006 Rev A Boost Off Normal Whispa II Whispa 50 Whispa E Hi-Line Lo-Line Lo-Line HC Slim-Line CSU

Hydronic Fan Convectors Fan Convectors are designed to provide heat in a minimum of space using forced convection. s efficient tangential fan design forces air uniformly across a low pressure drop heat exchanger, resulting in a high heat output from a very compact space. Fan Convectors all have several features in common: Fan bearings are porous bronze sleeves for longer life and quieter service Heat exchangers feature copper tubing expanded onto aluminum fins for greater heat transfer efficiency Each model has been certified by independent testing by ATL* to deliver 100% of the published heat output Each unit is manufactured to the high standards of s certification Each unit comes with at least a 3 year warranty; coverage for heat exchangers is extended to 10 years Technical specifications for the Fan Convector family are given on the following pages, showing specific dimensions and configuration, heat output, weights and head requirements. COMPARISON OF MAJOR FEATURES Whispa II Whispa II Whispa II Whispa 50 Whispa E Hi-Line Lo-Line Lo-Line HC Slim-Line CSU Kickspace Recessed Wall Recessed Floor Kickspace Kickspace Fan Fan Fan Fan Heater Heater Heater Heater Heater Convector Convector Convector Convector Page 1 3 4 5 6 7 8 9 10 11 Fan Unit Bearings Controls 2 Speed 2 Speed 2 Speed 2 Speed 2 Speed 2 Speed 3 Speed 3 Speed 3 Speed 2 Speed Heat Exchanger Construction Zinc-coated, Zinc-coated, Aluminum with Zinc-coated, Zinc-coated, Zinc-coated, Zinc-coated, Zinc-coated, Zinc-coated, Zinc-coated, painted steel, painted steel, mild steel grill & hardened painted steel painted steel painted steel painted steel painted steel epoxy/polyester hardened hardened epoxy/polyester aluminum grill, baked-on finish aluminum grill, aluminum grill, baked-on finish epoxy/polyester epoxy/polyester epoxy/polyester baked-on finish baked-on finish baked-on finish Water 1/2" Sweat 1/2" Sweat 1/2" Sweat 1/2" Sweat 1/2" Sweat 1/2" Sweat 1/2" Sweat 1/2" Compression 1/2" Sweat Connections Right Rear Corner Bottom Left Corner Side Right Rear Corner Upper Right Lower Left Corner Lower Left Corner Lower Left Corner Upper Left Corner Electric Rear 110V Rear 110V Rear 110V Rear 110V Left Rear 110V Right Rear 110V Right Rear 110V Right Rear 110V Right Rear 110V Connections 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz Tamper- Proof Cover Warranty 10 Year 10 Year 10 Year 10 Year 10 Year 10 Year 10 Year 10 Year 10 Year 10 Year Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, Heat Exchanger, 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor 3 Year Fan Motor Approvals Certifications ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* ATL Certified* BTU Range** 5000 5000W 5000 FM WH 50 EWH 20-14 19-15 HC 19-15 SL 16 CSU-10M 4,247-6,188 3,736-5,308 4,279-6,010 2,583-3,167 2,731-5,462 11,143-18,600 13,852-21,398 13,738-21,324 9,072-15,293 5,319-7,763 9000 9000W 15-10 14-10 HC 14-10 CSU-15M 8,639-10,875 6,522-9,571 8,688-15,542 11,873-17,458 11,896-17,504 7,317-10,331 10-6 9-6 HC 9-6 CSU-23M 6,461-9,640 8,917-11,363 9,038-11,506 9,518-16,947 7-4 6-4 HC 6-4 3,666-5,156 4,986-6,976 5,001-6,899 *ATL = Automated Test Labs, Philadelphia, PA **Based on entering water temperature of 180ºF @ 3GPM meets the highest quality manufacturing standards. Myson, Inc. 800-698-9690 www.mysoninc.com

Boost Off Normal Boost Off Normal WHISPATM II A New Generation in Kickspace Heaters WHISPA II KICKSPACE HEATER CERTIFIED BTU/HR OUTPUT ENTERING AIR @ 65 F MODEL FLOW RATE FAN AIR DELIVERY # GPM SPEED CFM WH II 5000 1.0 Boost 93 Normal 62 3.0 Boost 93 Normal 62 WH II 9000 1.0 Boost 134 Normal 95 3.0 Boost 134 Normal 95 reserves the right to make changes or improvements to our products which may affect these specifications. NOTE: For proper sizing, use the rating at normal speed. ENTERING WATER TEMPERATURE ( F), OUTPUT (BTU/hr) 110** 120** 130** 140 150 160 170 180 190 200 1,744 2,240 2,737 3,234 3,731 4,228 4,724 5,310 5,718 6,215 1,496 1,889 2,282 2,675 3,068 3,461 3,853 4,247 4,639 5,032 2,057 2,643 3,229 3,815 4,401 4,987 5,573 6,188 6,745 7,331 1,667 2,105 2,543 2,980 3,418 3,856 4,293 4,730 5,169 5,606 4,090 4,999 5,907 6,815 7,723 8,631 9,539 10,431 11,356 12,264 3,246 4,026 4,806 5,585 6,365 7,145 7,925 8,639 9,485 10,265 4,269 5,217 6,165 7,113 8,060 9,008 9,956 10,875 11,852 12,799 3,403 4,221 5,038 5,856 6,674 7,491 8,309 9,055 9,944 10,762 **For output at these water temperatures, optional 107 F low temperature cut-off required. HEAT OUTPUT COMPARISON @ 180 F WATER TEMP MODEL FLOW RATE FAN BASEBOARD C.I. RADIATORS # GPM SPEED (525 BTU/FT) (225 BTU/SQ FT) WH II 5000 3 Boost/Normal 11.7 ft / 9.0 ft 27 sq ft / 21 sq ft WH II 9000 3 Boost/Normal 20.8 ft / 17.4 ft 49 sq ft / 41 sq ft MODEL UNIT WEIGHT # WEIGHT PACKED WH II 5000 11 14 WH II 9000 15 20 MODEL FLOW RATE FT WG # GPM WH II 5000 1.0 / 3.0 0.13 / 1.20 WH II 9000 1.0 / 3.0 0.40 / 2.77 WH II 5000 Kickspace Heater Electrical Panel Cover WH II 9000 Kickspace Heater Electrical Panel Cover 12 1 /8" and return piping 16" and return piping 14 1 /4" Top View 17 3 /4" Top View 4" 19 3 /4" 4" Front View Grill 23 3 /4" Front View Grill 8" 12 1 /8/ " Side View " 16" Side View WHISPA II KICKSPACE FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. Controls... Units have a two-speed Boost/Off/Normal fan switch. For installations without a separate thermostat, all models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). from zinc-coated painted steel. The grill is hardened aluminum with a baked epoxy polyester finish for strength and durability. Available in black or white. Warranty... offers a full ten year Myson, Inc. 800-698-9690 www.mysoninc.com 1

Boost Normal MonoFlo Tees Simple and easy installation Off For installation detail, see MonoFlo or One Pipe System on page 13. EZ-HoseTM Kit Flexible Hose Connectors s EZ-Hose kit is specifically designed for installation with Fan Convectors. It allows the unit to be easily removed from the cabinet for quick connection and easy-access maintenance. These flexible hoses can save time and money, and they quickly solve those difficult access problems. EZ-Hose Kit... save time and money. s hose kit is so easy to use. The flexible hoses allow you to install the Fan Convectors from outside the cabinet. There s no need to remove the cabinet or cut ugly access doors in the bottom of the cabinet. EZ-Hose Kit... easy access installation. s two-hose system installs in minutes. Two MonoFlo tees (not included in kit) are installed in the heating loop. The hoses are then used to connect the convector to the heating loop. EZ-Hose Kit... maintenance is hassle-free. If you should need to service the Fan Convector, the EZ-Hose has an ample 30 inches of flexible hose so you can slide the unit completely out for maintenance. The Ball Valve with the slotted shut-off, enables you to disconnect the unit while maintaining the pressure of the system and you do not have to drain the system. Features: Flexible Designed with installation in mind, these 30" hoses with a 1 /2" female compression fitting on one end and a ball valve with screwdriver slot on the other end, provide enough length to allow installation outside of the cabinet. Tested Maximum operating temperature of 250 F and working pressure of 100psi. Easy Installation Installs in a fraction of the time required for conventional pipe installation... that saves time and money. Backed with confidence guarantees 100% satisfaction. Compatibility May be used with both water- and antifreezeprotected heating systems. 2 Myson, Inc. 800-698-9690 www.mysoninc.com

WHISPATM Recessed Wall Heaters WHISPA II RECESSED WALL HEATER CERTIFIED BTU/HR OUTPUT ENTERING AIR @ 65 F MODEL FLOW RATE FAN AIR DELIVERY # GPM SPEED CFM WH II 5000W 1.0 Boost 93 Normal 62 3.0 Boost 93 Normal 62 WH II 9000W 1.0 Boost 134 Normal 95 3.0 Boost 134 Normal 95 reserves the right to make changes or improvements to our products which may affect these specifications. NOTE: For proper sizing, use the rating at Normal speed. II ENTERING WATER TEMPERATURE ( F), OUTPUT (BTU/hr) 110** 120** 130** 140 150 160 170 180 190 200 1,728 2,139 2,555 2,976 3,400 3,827 4,257 4,689 5,125 5,562 1,393 1,721 2,051 2,384 2,719 3,056 3,396 3,736 4,079 4,422 2,008 2,472 2,939 3,409 3,881 4,354 4,830 5,308 5,786 6,267 1,619 1,988 2,359 2,731 3,104 3,478 3,853 4,229 4,605 4,983 3,068 3,805 4,553 5,309 6,072 6,842 7,618 8,400 9,186 9,977 2,417 2,988 3,566 4,149 4,736 5,328 5,923 6,522 7,123 7,728 3,558 4,396 5,244 6,098 6,958 7,825 8,696 9,571 10,451 11,335 2,717 3,356 4,001 4,652 5,307 5,966 6,628 7,294 7,963 8,635 **For output at these water temperatures, optional 107 F low temperature cut off required. HEAT OUTPUT COMPARISON @ 180 F WATER TEMP MODEL FLOW RATE FAN BASEBOARD C.I. RADIATORS # GPM SPEED (525 BTU/FT) (225 BTU/SQ FT) WH II 5000W 3.0 Boost/Normal 10.1 ft / 8.1 ft 24 sq ft / 19 sq ft WH II 9000W 3.0 Boost/Normal 18.2 ft / 13.9 ft 43 sq ft / 32 sq ft MODEL UNIT WEIGHT # WEIGHT PACKED WH II 5000W 18 21 WH II 9000W 21 25 MODEL FLOW RATE FT WG # GPM WH II 5000W 1.0 / 3.0 0.13 / 1.20 WH II 9000W 1.0 / 3.0 0.40 / 2.77 WH II 5000 Recessed Wall Heater WH II 9000 Recessed Wall Heater 17 3 /4" WH II 5000 Recessed Wall Heater 17 3 /4" WH II 9000 Recessed Wall Heater 3 5 /8" 14 3 /8" 3 /8" 3 5 /8" 17 15 /16" 3 /8" Top View Top View 14 1 /2" 18 1 /4" Wall Opening Wall Opening Air Vent Screw Additional Fixing Holes for 9000 Model (2 at top and bottom) Fixing Holes 3 each side Electrical Panel Cover Fixing Screws (8 offset) 19 1 /8" 16 1 /2" Front View Grill 19 1 /8" 19 1 /2" Front View Grill Piping Entry Wiring Entry 3 /4" 1 3 /8" 1 /8" 1 3 /8" Back View Front Cover 1" Piping 2 3 /4" 3 /4" Piping 2 3 /4" Wiring Bottom View Wiring Bottom View WHISPA II RECESSED WALL FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. Controls... Units have a two-speed Boost/Off/Normal fan switch. For installations without a separate thermostat, all models have low-limit thermostats which close at 129 and reopen at 109 ( ± 7 F). from zinc-coated painted steel. The grill is hardened aluminum with a white, baked epoxy polyester finish for strength and durability. Warranty... offers a full ten year Myson, Inc. 800-698-9690 www.mysoninc.com 3

WHISPATM II A Recessed Floor Fan Convector WHISPA II 5000 RECESSED FLOOR FAN CONVECTOR BTU/HR HEAT OUTPUT ENTERING AIR @ 65 F MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM (CFM) Whispa II 1.0 Boost 93 5000 FM Normal 62 Whispa II 3.0 Boost 93 5000 FM Normal 62 NOTE: For proper sizing, use the rating at Normal speed. ENTERING WATER TEMPERATURE ( F) 110* 120* 130* 140 150 160 170 180 190 200 1,995 2,473 2,957 3,447 3,941 4,440 4,942 5,448 5,957 6,469 1,597 1,972 2,350 2,731 3,115 3,601 3,889 4,279 4,671 5,064 2,200 2,728 3,262 3,803 4,348 4,898 5,462 6,010 6,572 7,136 1,762 2,175 2,592 3,013 3,436 3,862 4,290 4,721 5,153 5,587 *For output at these water temperatures, optional 120 F low temperature cut-off required. HEAT OUTPUT COMPARISON @ 180 F WATER TEMP MODEL FLOW RATE FAN SPEED BASEBOARD C.I. RADIATORS # GPM (525 BTU/FT) (225 BTU/SQ FT) WHISPA II 1 Boost/Normal 10.4 ft / 8.2 ft 24 sq ft / 19 sq ft 5000 FM 3 Boost/Normal 11.4 ft / 9.0 ft 26 sq ft / 21 sq ft MODEL UNIT WEIGHT # WEIGHT PACKED WHISPA II 5000 FM 15 lbs 18 lbs WHISPA II 5000 GAL/MIN (GPM) FT WG 1.0 0.3 3.0 3.5 15 13 /16" Flange Depth 9 5 /8" Flange Width 9 7 /16" 3 /4" Electrical Knockout 9 7 /16" 3 3 /4" 2 1 /4" 1 /2" Connection 1 /2" Connection 1 5 /8" 14 1 /4" 5 /8" 14 1 /4" Connections 1 5 /8" 8 1 /4" Dimensional View 9 3 /4" 15 7 /8" Grill NOTE: All connections accessible from the top of the unit. WHISPA II 5000 RECESSED FLOOR FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. Controls... Units may be wired to a wall switch or thermostat. All models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). Optional low temperature thermostat is available. from aluminum. The grill is mild steel with a baked epoxy polyester finish for strength and durability. Available in classic beige. Warranty... offers a full ten year 4 Myson, Inc. 800-698-9690 www.mysoninc.com

Boost Off Normal WHISPATM 50 Kickspace Heaters from WHISPA 50 FAN CONVECTOR BTU/HR HEAT OUTPUT ENTERING AIR @ 65 F MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM CFM WH 50 1.0 Boost 46 Normal 38 3.0 Boost 46 Normal 38 reserves the right to make changes or improvements to our products which may affect these specifications. NOTE: For proper sizing, use the rating at Normal speed. KICKSPACE COMPARISON @ 180 F WATER TEMP MODEL GPM SPEED BASEBOARD C.I. RADIATORS # (525 BTU/FT) (225 BTU/SQ FT) WH 50 3 Boost / Normal 6.0 ft / 5.3 ft 14 sq ft ENTERING WATER TEMPERATURE ( F) 110** 120** 130** 140 150 160 170 180 190 200 210 1,135 1,372 1,606 1,839 2,070 2,299 2,527 2,754 2,980 3,204 3,428 917 1,145 1,377 1,612 1,850 2,093 2,336 2,583 2,833 3,083 3,336 1,305 1,578 1,847 2,115 2,380 2,644 2,906 3,167 3,427 3,685 3,942 931 1,225 1,473 1,725 1,980 2,239 2,500 2,764 3,031 3,299 3,570 **For output at these water temperatures, optional 107 low temperature cutoff required. MODEL UNIT PACKED # WEIGHT WEIGHT WH 50 9 11 GAL/MIN(GPM) FT. WG 1.0 0.9 3.0 3.3 Electrical Panel Cover and return piping 7 1 /2/ " 14" Top View 3" Grill 7 1 /2/ " Side View WHISPA 50 KICKSPACE FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. Controls... Units have a two-speed Boost/Off/Normal fan switch. For installations without a separate thermostat, all models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). from zinc-coated painted steel. The grill is hardened aluminum for strength and durability. Warranty... offers a full ten year Myson, Inc. 800-698-9690 www.mysoninc.com 5

DO NOT COVER DO NOT COVER IMMEDIATELY DISCONNECT FROM THE MAINS BEFORE REMOVING THIS COVER WHISPATM E Electric Kickspace Heater from WHISPA E KICKSPACE HEATER COMPARISON TO BASEBOARDS & RADIATORS* BASEBOARD C.I. RADIATORS MODEL SETTINGS V/Hz WATTS BTUs AMPS (525 BTU/FT) (225 BTU/SQ FT) EWH High 110V/60Hz 1600 5,462 13 10.4 ft. 24.3 sq. ft. Low 110V/60Hz 800 2,731 6.5 5.2 ft. 12.1 sq. ft. *For comparison, a water temperature of 180 F has been assumed. NOTE: For proper sizing, use the rating at Medium or Low speeds. A Width 20" B Height 4" (min.) C Depth 16" D Base Shelf Overhang 1" INSTALLATION DIMENSIONS A B D Be sure to provide sufficient space around the unit to allow for adequate air circulation. C UNIT WEIGHT UNIT WEIGHT MODEL WEIGHT PACKED EWH 8.1 lbs 10 lbs CONTROLS Power/Fan Settings: OFF ON Indicated by red light. Heater Settings: OFF LOW (Either Position) HIGH WHISPA E KICKSPACE HEATER DIMENSIONS Model # EWH 15 1 2" 14" WHISPA-E FACE 4" 8 7 8" WHISPA-E 19 11 16" WARNING PLINTH HEATER WHISPA-E VOLTS-120VAC. 60 HZ AMPS-13 WATTS-1600 MADE IN THE U.K. USE ONLY ON 20 AMPERE BRANCH CIRCUIT Front view with unit height 19 11 16" Top view WHISPA E ELECTRIC KICKSPACE HEATER SPECIFICATIONS Engineered to be efficient. Fan Unit... A highly efficient 110 cfm tangential fan extends the full width of the heating element, giving extremely quiet, trouble-free operation. All units have aluminum fans, sealed motor bearings, and permanently lubricated bearings. Controls... Units have a lighted fan switch to indicate power ON. Heat is controlled using a dual rocker switch both switches OFF for fan only, either switch ON for 800 Watts (Low), and both switches ON for 1600 Watts (High). Each unit has a high temperature limit switch to shut off power in the event of excessive temperature resulting from restricted airflow. 6 Myson, Inc. 800-698-9690 www.mysoninc.com from zinc-coated painted steel. The grill is hardened aluminum for strength and durability. Electrical connections... Wiring connections are supplied through the rear of each unit. Motor is 110V, 60Hz and is ETL listed. Dual heating elements draw a total of 15 amps on the high setting.

Hi-LineTM Fan Convector from HI-LINE FAN CONVECTORS BTU/HR HEAT OUTPUT ENTERING AIR @ 65 F MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM1 CFM 20-14 3.0 Boost 197 Normal 102 15-10 3.0 Boost 164 Normal 90 10-6 3.0 Boost 106 Normal 64 7-4 3.0 Boost 55 Normal 34 ENTERING WATER TEMPERATURE ( F) 110** 120** 130** 140 150 160 170 180 190 200 6,940 8,569 10,213 11,870 13,538 15,217 16,904 18,600 20,303 22,013 4,141 5,118 6,104 7,099 8,101 9,109 10,123 11,143 12,168 13,197 5,778 7,140 8,516 9,903 11,300 12,706 14,120 15,542 16,970 18,405 3,224 3,985 4,755 5,531 6,313 7,100 7,892 8,688 9,488 10,292 3,578 4,422 5,276 6,137 7,005 7,878 8,757 9,640 10,528 11,419 2,397 2,963 3,535 4,112 4,694 5,280 5,869 6,461 7,056 7,654 1,912 2,364 2,821 3,281 3,746 4,213 4,683 5,156 5,631 6,108 1,357 1,678 2,003 2,331 2,662 2,994 3,329 3,666 4,004 4,345 1 NOTE: Correction factor for 1.0 gpm, multiply by 0.87 **For output at these water temperatures, optional 107 low temperature cut-off required. NOTE: For proper sizing, use the rating at Normal speed. reserves the right to make changes or improvements to our products which may affect these specifications. FAN CONVECTOR COMPARISON @ 180 F WATER TEMP MODEL FLOW RATE FAN SPEED BASEBOARD C.I. RADIATORS # GPM (525 BTU/FT) (225 BTU/SQ FT) 20-14 3.0 Boost/Normal 35/21 ft 83/50 sq ft 15-10 3.0 Boost/Normal 30/17 ft 69/39 sq ft 10-6 3.0 Boost/Normal 18/12 ft 43/29 sq ft 7-4 3.0 Boost/Normal 10/7 ft 23/16 sq ft MODEL UNIT WEIGHT # WEIGHT PACKED 20-14 33.5 37.5 15-10 27.0 31.0 10-6 18.5 22.0 7-4 14.5 17.5 MODEL FT WG # 1 GPM 3 GPM 20-14 0.58 2.68 15-10 0.45 2.08 10-6 0.27 1.57 7-4 0.22 1.36 4 7 / 8 " 2 DIMENSIONS Water Connection 2" MODEL # A B 20-14 46 1 4" 43 1 2" 15-10 36" 30 3 4" 3 1 /8/ " Wiring Connection Top View 10-6 25 1 2" 20 3 16" 7-4 20 5 8" 15 3 8" 2 1 8" Wiring 1 1 /8" 1 /4/ " 5" 2 1 /4/ " 4 3 / 4 " 2 /4/ " 3 " 5" 7" Mounting Holes 14 1 /4/ " Pipe Wiring Pipe B NOTE: For surface mounting application only. A 5" Front View Side View NOTE: Piping and wiring openings are accessible from either top or back. Controls... Units have a two-speed Boost/Off/Normal fan switch. For installations without a separate thermostat, all models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). HI-LINE FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. from zinc-coated painted steel. Warranty... offers a full ten year Myson, Inc. 800-698-9690 www.mysoninc.com 7

Lo-LineTM Fan Convector from LO-LINE FAN CONVECTORS BTU/HR HEAT OUTPUT ENTERING AIR @ 65 F MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM 1 (CFM) Boost 221 19-15 3.0 Medium 179 Low 132 Boost 186 14-10 3.0 Medium 138 Low 94 Boost 96 9-6 3.0 Medium 69 Low 52 Boost 60 6-4 3.0 Medium 42 Low 28 1 NOTE: Correction factor for 1.0 gpm, multiply by 0.87 NOTE: For proper sizing, use the rating at Medium or Low speeds. FAN CONVECTOR COMPARISON @ 180 F WATER TEMP MODEL FAN SPEED BASEBOARD C.I. RADIATORS # (525 BTU/FT) (225 BTU/SQ FT) 19-15 Boost/Med/Low 41/33/26 ft 95/77/61 sq ft 14-10 Boost/Med/Low 33/27/23 ft 78/64/53 sq ft 9-6 Boost/Med/Low 22/20/17 ft 51/46/40 sq ft 6-4 Boost/Med/Low 13/11/10 ft 31/26/22 sq ft ENTERING WATER TEMPERATURE ( F) 110** 120** 130** 140 150 160 170 180 190 200 8,715 10,560 12,392 14,212 16,021 17,821 19,613 21,398 23,176 24,948 7,026 8,513 9,989 11,454 12,912 14,361 15,805 17,242 18,674 20,101 5,647 8,841 8,027 9,204 10,374 11,539 12,698 13,852 15,002 16,148 7,118 8,624 10,118 11,602 13,077 14,544 16,004 17,458 18,908 20,352 5,812 7,041 8,260 9,471 10,674 11,872 13,063 14,250 15,432 16,610 4,846 5,870 6,885 7,893 8,896 9,893 10,885 11,873 12,857 13,838 4,637 5,617 6,589 7,554 8,513 9,488 10,417 11,363 12,305 13,244 4,196 5,081 5,959 6,831 7,698 8,559 9,417 10,271 11,122 11,969 3,642 4,410 5,173 5,930 6,682 7,431 8,175 8,917 9,856 10,392 2,815 3,418 4,017 4,614 5,207 5,799 6,388 6,976 7,562 8,146 2,382 2,885 3,383 3,878 4,370 4,859 5,345 5,830 6,313 6,793 2,040 2,470 2,896 3,319 3,739 4,157 4,572 4,986 5,398 5,809 **For output at water temperatures below 140 F, optional 107 F low temperature cut-off required. MODEL UNIT WEIGHT # WEIGHT PACKED 19-15 35.5 38.5 14-10 30.0 33.0 9-6 21.0 24.5 6-4 16.5 20.0 MODEL FT WG # 0.5 GPM 1.25 GPM 19-15 0.6 3.0 14-10 0.4 2.4 9-6 0.4 2.3 6-4 0.4 2.1 DIMENSIONS A 2 1 /16" MODEL # A 19-15 45 1 8" 14-10 35 9 16" 18 1 /2" 14 13 /16" 9 7 /16" Water Connections 9-6 25" 6-4 20 3 16" Front View 3 3 /16" 6" Side View Pipe Entry 1 7 / 8 " 5 1 /2" Cable Entry 1 11 /16" 2 9 /16" 4 5 /8" NOTE: For surface mounting application only. Bottom View Controls... Units have a three-speed Boost/Medium/Low fan switch and built-in thermostat. All models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). LO-LINE FAN CONVECTOR SPECIFICATIONS - Engineered to be efficient. from zinc-coated painted steel. Tamper-Proof Controls Cover... All units include a tamper-proof controls cover which conceals all electrical controls from unauthorized usage. Warranty... offers a full ten year 8 Myson, Inc. 800-698-9690 www.mysoninc.com

Lo-LineTM HC Heating and Cooling from a Single Convector LO-LINE HC FAN CONVECTORS BTU/HR HEAT OUTPUT ENTERING AIR @ 65 F MODEL FLOW RATE POWER FAN SPEED AIR DELIVERY ENTERING WATER TEMPERATURE ( F) # GPM 1 WATTS (CFM) 110** 120** 130** 140 150 160 170 180 190 200 Boost 221 7,817 9,654 11,525 13,429 15,357 17,316 19,305 21,324 23,372 25,448 HC 19-15 3.0 60 Medium 179 6,381 7,871 9,385 10,924 12,487 14,074 15,683 17,315 18,969 20,645 Low 132 5,064 6,246 7,447 8,668 9,908 11,166 12,443 13,738 15,049 16,374 Boost 186 6,383 7,886 9,418 10,979 12,569 14,187 15,832 17,504 19,203 20,928 HC 14-10 3.0 60 Medium 138 5,237 6,468 7,722 8,999 10,299 11,618 12,954 14,309 15,685 17,080 Low 94 4,376 5,399 6,440 7,498 8,573 9,664 10,772 11,896 13,036 14,191 Boost 96 4,209 5,198 6,207 7,233 8,279 9,342 10,416 11,506 12,613 13,735 HC 9-6 3.0 40 Medium 69 3,836 4,732 5,644 6,572 7,514 8,471 9,442 10,427 11,426 12,438 Low 52 3,331 4,109 4,900 5,703 6,519 7,346 8,186 9,038 9,902 10,775 Boost 60 2,518 3,110 3,714 4,329 4,956 5,593 6,241 6,899 7,569 8,246 HC 6-4 3.0 25 Medium 42 2,133 2,635 3,147 3,668 4,199 4,739 5,288 5,846 6,413 6,985 Low 28 1,821 2,250 2,688 3,134 3,589 4,052 4,522 5,001 5,487 5,981 1 NOTE: Correction factor for 1.0 gpm, multiply by 0.87 **For output at water temperatures below 140 F, optional 107 F low temperature cut-off required. NOTE: For proper sizing, use the rating at Medium or Low speeds. FAN CONVECTOR COMPARISON @ 180 F WATER TEMP MODEL FAN SPEED BASEBOARD C.I. RADIATORS # (525 BTU/FT) (225 BTU/SQ FT) HC 19-15 Boost/Med/Low 41/33/26 ft 95/77/61 sq ft HC 14-10 Boost/Med/Low 33/27/23 ft 78/64/53 sq ft HC 9-6 Boost/Med/Low 22/20/17 ft 51/46/40 sq ft HC 6-4 Boost/Med/Low 13/11/10 ft 31/26/22 sq ft MODEL UNIT WEIGHT # WEIGHT PACKED HC 19-15 35.5 38.5 HC 14-10 30.0 33.0 HC 9-6 21.0 24.5 HC 6-4 16.5 20.0 MODEL FT WG # 0.5 GPM 1.25 GPM HC 19-15 0.6 3.0 HC 14-10 0.4 2.4 HC 9-6 0.4 2.3 HC 6-4 0.4 2.1 18 1 /2" Pipe Entry 1 7 / 8 " 5 1 /2" A Front View Cable Entry Bottom View 1 11 /16" 2 9 /16" 4 5 /8" 2 1 /16" 14 13 /16" 3 3 /16" 9 7 /16" Side View Water Connections 6" NOTE: For surface mounting application only. DIMENSIONS MODEL # A HC 19-15 45 7 8" HC 14-10 35 7 8" HC 9-6 25" HC 6-4 20 1 4" COOLING MODE: ENTERING WATER/AIR TEMP. DIFF. ºF Model Flow Fan Latent* BTU/hr Sensible BTU/hr # Rate Speed 25ºF 35ºF 45ºF 25ºF 35ºF 45ºF HC 19-15 3 gpm Boost 6,430 10,638 15,488 5,239 6,263 7,157 Medium 6,080 10,035 14,588 4,774 5,806 6,719 Low 5,466 8,995 13,042 4,333 5,163 5,886 HC 14-10 3 gpm Boost 4,932 8,088 11,706 4,166 5,075 5,882 Medium 4,034 6,588 9,503 3,449 4,132 4,731 Low 3,359 5,485 7,853 2,934 3,608 4,211 HC 9-6 3 gpm Boost 2,662 4,314 6,187 2,169 3,013 3,849 Medium 2,218 3,585 5,132 1,961 2,324 2,638 Low 1,822 2,939 4,204 1,626 1,943 2,218 HC 6-4 3 gpm Boost 1,810 2,921 4,178 1,459 2,026 2.590 Medium 1,409 2,271 3,243 1,275 1,561 1,816 Low 1,147 1,845 2,633 1,047 1,300 1,527 *These figures are at 50% relative humidity. LO-LINE HC FAN CONVECTOR SPECIFICATIONS - Engineered to be efficient. Fan Unit... A highly efficient tangential fan extends the full width of the heat exchanger, giving extremely quiet, trouble-free operation. All units have aluminum fans, sealed motor bearings, and permanently lubricated porous bronze sleeve fan bearings. Controls... The Lo-Line Heater Cooler has a three speed fan, best controlled by a 110V AC heat/cool thermostat with 3-speed sub-base. (By others.) Heat Exchanger... Fin tube heat exchanger is a manifold design with copper water conduits expanded to create firm contact with the surrounding aluminum fins. Special air turbulator design maximizes the rate of heat transfer. All units are hydraulically tested to 300 psi. Tamper-Proof Controls Cover... All units include a tamper-proof controls cover which conceals all electrical controls from unauthorized usage. from zinc-coated painted steel. Water Connections and return are 1 /2" copper to compression isolation valves in the lower left corner of the unit. An air vent(s) for bleeding the convector is easily accessed through the front of the unit with a screwdriver. No special key is needed. Warranty offers a full ten year Myson, Inc. 800-698-9690 www.mysoninc.com 9

Slim-LineTM Fan Convector from MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM CFM SL 16 1.0 Boost 186 Medium 127 Low 97 SL 16 3.0 Boost 186 Medium 127 Low 97 Slim-Line Fan Convector SLIM-LINE FAN CONVECTOR BTU/HR HEAT OUTPUT ENTERING AIR @ 65 F reserves the right to make changes or improvements to our products which may affect these specifications. NOTE: For proper sizing, use the rating at Medium or Low speeds. FAN CONVECTOR COMPARISON @ 180 F WATER TEMP MODEL FLOW RATE FAN SPEED BASEBOARD C.I. RADIATORS # GPM (525 BTU/FT) (225 BTU/SQ FT) SL 16 1.0 Boost 22 ft 52 sq ft Medium 20 ft 46 sq ft Low 17 ft 40 sq ft SL 16 3.0 Boost 29 ft 68 sq ft Medium 26 ft 60 sq ft Low 23 ft 53 sq ft ENTERING WATER TEMPERATURE ( F) 120* 130* 140 150 160 170 180 190 200 210 5,663 6,657 7,661 8,664 9,668 10,572 11,678 12,680 13,684 14,687 4,881 5,887 6,745 7,651 8,559 9,567 10,374 11,281 12,186 13,096 4,207 5,018 5,829 6,639 7,450 8,261 9,072 9,883 10,694 11,504 7,404 8,719 10,034 11,349 12,663 13,978 15,293 16,608 17,923 19,237 6,457 7,646 8,831 10,023 11,411 12,399 13,588 14,776 16,280 17,153 5,510 6,572 7,634 8,696 9,758 10,820 11,882 12,944 14,005 15,068 *For output at these water temperatures, optional 107 F low temperature cut-off required. MODEL UNIT WEIGHT # WEIGHT PACKED SL 16 35 38 FLOW RATE FT WG GPM 0.5 0.66 1.0 1.84 1.5 3.81 2.0 5.81 2" 3 /4" 6 11 /16" 15 9 /16" 31 7 /8" 3 1 /4" 6 7 /8" NOTE: For surface mounting application only. 1 7 /8" 1 3 /8" Side View 5" Centerlines of pipe entry Minimum space required (floor to bottom of Slim-Line) 2 5 /16" C L Centerline of pipe entry Front View Controls... Units have a three-speed Boost/Medium/Low fan switch and built-in thermostat. All models have low-limit thermostats which close at 129 F and reopen at 109 F (±7 F). SLIM-LINE FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. from zinc-coated painted steel. Tamper-Proof Controls Cover... All units include a tamper-proof controls cover which conceals all electrical connections from unauthorized usage. 10 Myson, Inc. 800-698-9690 www.mysoninc.com Warranty... offers a full ten year

CSUTM Economical Fan Convector from MODEL FLOW RATE FAN SPEED AIR DELIVERY # GPM1 CFM CSU-10M 3.0 Boost 99 Normal 62 CSU-15M 3.0 Boost 91 Normal 66 CSU-23M 3.0 Boost 129 Normal 92 1 Note: Correction factor for 1.0 gpm, multiply by 0.87 reserves the right to make changes or improvements to our products which may affect these specifications. CSU FAN CONVECTOR BTU/HR HEAT OUTPUT ENTERING AIR @ 65 F FAN CONVECTOR COMPARISON @ 180 F WATER TEMP MODEL FLOW RATE FAN SPEED BASEBOARD C.I. RADIATORS # GPM (525 BTU/FT) (225 BTU/SQ FT) CSU-10M 3.0 Boost/Normal 11/16 ft 27/38 sq ft CSU-15M 3.0 Boost/Normal 16/23 ft 37/53 sq ft CSU-23M 3.0 Boost/Normal 21/36 ft 48/85 sq ft ENTERING WATER TEMPERATURE ( F) 120** 130** 140 150 160 170 180 190 200 210 2,437 3,226 4,173 5,195 6,040 6,852 7,763 8,659 9,500 10,341 1,190 1,954 2,529 3,165 3,823 4,481 5,319 5,973 6,609 7,245 1,928 3,886 4,994 6,102 7,203 8,715 10,331 11,947 14,000 15,053 1,524 2,484 3,452 4,418 5,385 6,352 7,317 8,282 9,240 10,198 4,400 6,481 8,573 10,665 12,750 14,838 16,947 19,027 21,000 23,235 2,018 3,461 4,687 5,751 6,983 8,260 9,518 10,813 12,262 13,771 **For output at these water temperatures, optional 107 low temperature cut-off required. NOTE: For proper sizing, use the rating at Normal speed. MODEL UNIT WEIGHT # WEIGHT PACKED CSU-10M 17 22 CSU-15M 22 28 CSU-23M 30 38 MODEL FT WG # 1 GPM 3 GPM CSU-10M 0.45 2.58 CSU-15M 0.70 3.22 CSU-23M 0.78 3.66 CSU Fan Convector DIMENSIONS A MODEL # A B CSU-10M 21 3 8" 17 1 4" CSU-15M 28 7 8" 24 7 8" Top View CSU-23M 41 3 8" 37 1 2" 4 23 /32" 1 1 /2" 3 3 /4" A B Air Out 6 1 /4" Back panel mounting holes 13 1 /4" 2 9 /16" Optional legs provided with unit Air In Wall Side Front View Side View Water connections 7 /8" conduit hole 3" 5 /8" NOTE: For surface or floor mounting application only. 9 /16" 1 9 /16" Bottom View 1 9 /16" Controls... Units have a two speed Boost/Normal fan switch and built-in thermostat. All models have low-limit thermostats which close at 129 F and open at 109 F (± 7 F). Optional low temperature thermostat is available. CSU FAN CONVECTOR SPECIFICATIONS Engineered to be efficient. from zinc coated steel with a baked epoxy polyester. Warranty... offers a full ten year Myson, Inc. 800-698-9690 www.mysoninc.com 11

Kickspace Fan Convector Installation 1. A kickspace heater must have a free flow of air through the unit. We have designed our grills to allow for sufficient airflow. The opening in the kickspace must allow unrestricted airflow. (See drawing below.) Looking at the grill, you should not be able to see any part of the kickboard. Failure to do so will cause the motor to overheat and void the warranty. 2. The kickspace heater needs to be sized appropriately for the job. For proper sizing, use the ratings at normal speed. If the unit needs to be in the boost or high setting to heat the room adequately, then the kickspace heater is too small. Running the unit in boost or high for extended periods of time will shorten the motor fan assembly life. If the heating unit is below the main or more than 4 1 /2 feet horizontally from the main, install two MonoFlo tees with the supply arrows facing each other. Keep and Tees 12" apart Water Flow Water Flow 12" Water Flow Mounting Screws Cut cabinet kick plate so make up air can get in. Cabinet Kick Plate Cool Air Intake Fan Motor Assembly Cool Air Intake Cut cabinet kick plate so make up air can get in. WH II 5000 rough opening is 18 3 /4" WH II 9000 rough opening is 22 3 /4" Cabinet Kick Plate Cool Air Intake Cool Air Intake ON/OFF Switch Hot Air EZ-Hose Kit The EZ-Hose Kit is designed specifically for use with the WH II 5000 and WH II 9000 Kickspace Heaters. While it may be used for other hydronic products, will not be responsible for compatibility. Components: 2-30" braided stainless steel hoses, 1 /2" compression x 1 /2" MPT 2 - Screwdriver slot ball valves, 1 /2" compression x 1 /2" FPT Assemble the male end of the hose to the female end of the ball valve using the recommended Loctite #565 thread sealant. Connect the compression end of the hoses to the stub-outs on the kickspace unit. Make sure that the return side hose is connected to the top stub-out so that air will be forced through the heat exchanger to where it can be removed at the air vent. Connect the compression ends of the ball valves to the appropriate supply and return pipes from the heating system. Copper Pipe Copper Pipe 12 Myson, Inc. 800-698-9690 www.mysoninc.com

and Fan Convector Installation Optional Piping Arrangements The following drawings are general examples. Consult a certified heating professional for your specific application. recommends TRV valves on all layouts except series loop system for maximum comfort and control of radiators. This does not apply to Fan Convectors. General information on the use of MonoFlo tees: Scoop type is installed on the supply Venturi type is installed on the return Boiler MonoFlo Tee Circulation Pump 12" Regular MonoFlo or Tee Venturi Tee Loop pipe size varies with load MonoFlo or One Pipe System Acceptable for all heating applications, balancing valves required. If heating unit is below the main or more than 4 1 /2 feet horizontally from the main, install two MonoFlo tees with the supply arrows facing each other Fan Convectors and Cast Iron s have different heating characteristics. Therefore, it is recommended that the Fan Convector be on a separate controlled heating zone. Circulation Pump Boiler Boiler Circulation Pump Circulation Pump Regular Tee 12" MonoFlo Tee Series Loop System Not compatible with fan convectors. Limited to 15K btuh on panel radiators. A single Fan Convector may be added using MonoFlo tees as shown. Two Pipe Reverse System Acceptable for all heating applications, balancing valves required when a Fan Convector is used with radiators. Radiant Manifold Circulation Pump Boiler Circulation Pump Regular Tee Boiler Two Pipe Direct System Acceptable for all heating applications, balancing valves required. Home Run System Myson, Inc. 800-698-9690 www.mysoninc.com 13

The Limited Warranty warrants the original purchaser that products manufactured and/or supplied by them will be free from defects in materials and workmanship under normal conditions of use, when properly installed and maintained in accordance with s instructions for a period of 36 months. During this warranty period, will, at its option, repair or replace any product, or part thereof, which shall be returned to the factory and determined by to be defective. THE PARTS WARRANTY: warrants replacement parts, when properly installed and maintained for a period of 120 days from the date of purchase. There are no warranties, expressed or implied, that extend beyond this warranty description. In no event will be liable for labor or consequential damages. HEATING PRODUCTS Myson, Inc. 948 Hercules Drive Colchester, VT 05446 800-698-9690 Fax: 802-654-7022 www.mysoninc.com 10M 260021 1/2006