VAV compact controller KNX / PL-Link



Similar documents
VAV compact controller KNX / PL-Link

Air damper actuators

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Digital input modules

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

RRV934. Multi-controller. Synco living

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

PC Software for VAV compact and modular controllers

TX OPEN RS232/485 module

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

OZW V2.0. Web server. Synco TM, Synco TM living

Duct Humidity Transmitter

PCS0100en Persy Control Services B.V. Netherlands

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Web-Server OZW V5.2

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

OZW30. Central Unit SYNERGYR

HCR3.2/.. Chipcard reader HOTEL SOLUTION

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Building Technologies

Quick running actuator

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

OZW V4.0. Web server. For Synco TM, Synco TM living

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Input module, input/output module

Telefon (+45) Telefax (+45) Installation and operating manual

Flush-mounted room thermostats

Series 6000 Torque measured metal bellow coupling

Actuator for modulating control AME 435

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Electronic Control Devices The European Product Catalogue 2007

OpenAir robust damper actuators for energy-efficient ventilation

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

KNX. Siemens Building Technologies HVAC Products. Synco Konnex bus. For devices of the Synco 700 / RXB ranges

Inwall 4 Input / 4 Output Module

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Electric Rotary Actuator - On/Off or programmable control actuator

EBDSPIR-PRM, EBDSPIR-PRM-IP

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Addendum to the Operating Instructions

Short information Parameters are programmed via front-side membrane keypad

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

OZW672...V5.2. Web-Server. For LPB/BSB plants

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Synco Central Communication Unit OZW771 Basic Documentation

Series 7500 Torque Sensor

Inductive sensor NI10-M18-Y1X-H1141

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

GREISINGER electronic GmbH

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

IntesisBox KNX Mitsubishi Heavy Industries AC

DC Electronic Loads 8500 series

Absolute Rotary Encoder E6CP

Product and functional description

Room Temperature Sensors

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

PXM20-E. Operator unit DESIGO PX

Givare NC-SRS 280 och 880

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

IntesisBox KNX Modbus TCP master

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

DALI RC BASIC SO. Control unit Operating instructions

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Drayton Digistat +2RF/+3RF

T7560A,B,C Digital Wall Module

Cross-beam scanning system to detect slim objects. 100 mm in

Panel Meters and Controllers Modular Panel Meter Type EDM 35

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

PHD User Manual. Table of Contents

Belimo Gateway MP to Modbus RTU - UK24MOD

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

ACS-30-EU-EMDR-10-MOD

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

1. SAFETY INFORMATION

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Reaction Torque Sensor

Inwall Room Temperature Unit

Thyristor-controlled power supplies and battery chargers

MINIMAT-EC-Servo Screwdriver Spindles

Engineering and service software For KNX and LPB plants

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Transcription:

s 3 547 OpenAir VAV compact controller KNX / PL-Link Series E GDB181.1E/KN GLB181.1E/KN Networked compact controller featuring KNX (S-mode / LTE-mode) and PL- Link capability for plants with variable air volume flow Integrated, highly precise differential pressure sensor, actuator as well as digitally configurable air volume controller Operating voltage AC 24 V Nominal torque 5 or 10 Nm; air damper angular rotation can be adjusted mechanically from 0 to 90 Can be configured as a stand-alone device per room or cascade control 1:1 pressure ratios; positive or negative pressure Pre-wired with a 0.9 meter power cable and 0.9 meter KNX cable Note Please refer to Technical Basics P3547 for a comprehensive description of safety, engineering and commissioning notes as well as mounting instructions for VAV compact controllers. CE1N3547en 2016-01-29 Building Technologies

Application VAV compact controllers are primarily used for controlling a variable or constant air volume flow. System environments: Building automation systems using the Siemens peripheral bus PL-Link (Desigo Total Room Automation) Building automation systems using KNX LTE-mode (Synco 700 Step 3 and newer) Building automation systems using KNX S-mode (third-party integration and freely programmable devices) Application fields: Supply air control Extract air control Supply/extract cascade control with Ratio control 1:1 Ratio control (positive/negative pressure) Differential control (positive/negative pressure) Air dampers with a nominal torque of up to 5 or 10 Nm VAV compact controllers are not suitable for environments where the air is saturated with sticky or fatty particles or contain aggressive substances. Type summary Type Torque Application range Operating voltage GDB181.1E/KN 5 Nm 0...300 Pa AC 24 V GLB181.1E/KN 10 Nm 0...300 Pa AC 24 V Please refer to data sheet N4698 for information on accessories and spare parts. Equipment combinations VAV compact controllers are KNX certified and may be connected to all KNX devices compatible with S-mode data points. Device Type Data sheet Controllers and room units Room thermostat with controller RDG400KN 3192 Room thermostat RDU341 3172 Universal controller RMU7.. 3144 Web server OZW7.. 5702 PL-Link automation station PXC3.. 9203 Tools for configuration and service Handheld tool AST10* 5851 Interface converter AST11 5852 PC software for service ACS941 v3.0 or later* 5854 Service kit (ACS941 + AST11) AST21 - Tools for engineering and commissioning (partially suitable for device configuration) Tools for PL-Link Desigo ABT / SSA Tool for KNX LTE-mode Synco ACS790 Tools for KNX S-mode ETS3 / ETS4 * AST 10 / ACS941 v2.x: limited functionality for VAV compact controllers 2 / 10

Design Main device parts 1 2 3 4 3547J01 10 9 8 1 Shaft attachment screw 2 LED 3 Push button 4 Configuration and maintenance interface (below cover) 5 Connection nozzle for measuring differential pressure in the VAV box 6 Connection nozzle for measuring differential pressure in the VAV box ("+": Side with higher pressure) 7 2 connecting cables (power and communications), 2-core each 8 Disengagement of gear 9 Rotation angle display 10 Rotation angle check screw 7 6 5 Human-Machine- Interface (HMI) The HMI consists of an LED (1) and a push button (2). Push button Push button operation Description Short key press (<0.5 s) Middle key press (>2 s and <20 s) Long key press (>20 s) Switch to programming mode or cease display of connection test results Execute connection test (Note: Only available with PL-Link) Reset to factory settings LED state display LED display off / dark orange (flashing) (1x) orange (flashing) red red green Description a) Device not connected to power source b) Device is connected to power source and operates without failure Feedback for middle key press Wait (connection test or reset to factory settings) Connection test not successful Device in programming mode Connection test successful 3 / 10

Note For further information on settings, operating modes, and engineering and commissioning workflows in the available system environments, please refer to Technical Basics P3547. Settings and operating mode Parameterization OEM generally provide the basic configuration to VAV compact controllers, especially the parameter V n. Configuration depends on the system environment were the VAV compact controllers are used (i.e. PL-Link, KNX LTE-mode, KNX S- mode). Overall system engineering and commissioning is based on this basic configuration; accomplished using tools listed under equipment combinations (p. 2). The following parameters must be checked or set prior to commissioning: Parameter Setting Description Siemens factory setting V n 1 3,16 Characteristic value for the air volume flow; set by the manufacturer (OEM) V max 20 120 % Maximum air volume flow 100 % V min -20 100 % Minimum air volume flow 0 % Dir r or L Air damper rotation (opening direction) r = Clockwise (CW) L = Counter clockwise (CCW) ADP Off or on Standard mode for air damper position display (Mapping 0...90 0 100 %) Adaptive mode for air damper position display (Mapping e.g. 0 60 0 100 %) Altitude 0 5000 m (Resolution 500 m) Altitude level for differential pressure sensor 1 r Off 500 meters Variable air volume control (VAV) VAV compact controllers operate in VAV mode when connected to the specified power supply. The setpoint signal determines the operating range V min V max. Vmin [%] Vmax [%] 1 Setpoint point 2 Actual value 3 Controlled area 3 Constant air volume control (CAV) The VAV compact controllers can be operated in CAV mode by setting the setpoint value accordingly. 4 / 10

Commissioning Commissioning variants Three commissioning procedures are available. System / network environment PL-Link KNX LTE-mode Engineering and commissioning tool(s) Desigo ABT, SSA Synco ACS790 KNX S-mode ETS3, ETS4 Basic knowledge of the tools required. An interface converter, e.g. OCI700 required to connect a PC with USB interface to a KNX network, Number and type of parameters may vary depending on the system environment. Commissioning requirements Operating mode and display Prior to commissioning, all VAV compact controllers must be mounted according to the mounting instruction M3547 as well as all other devices as per the corresponding mounting instructions. All devices must be connected to the power supply and bus cabling. Power supply and bus cabling must be tested. After power-up, the device can assume the following states: State / desired behavior User action Device response (LED) Functionality available in all system environments Power-up / device starts up Connect device to power supply Faultless operation none LED is off LED is orange / goes off after power-up is completed Set device to programming / addressing mode Reset device to factory settings Short key press (<0.5 s) Long key press (>20 s) LED is red (no time limit) LED flashes orange until reset is completed Additional functionality available in PL-Link environments only Execute connection test Middle key press (>2 s and <20 s) LED flashes orange Then (each for 60 seconds or prior cancellation by key press): a) LED is green connection test successful b) LED flashes red (1s interval) connection test failed Acknowledge connection test Short key press (<0.5 s) LED is off 5 / 10

PL-Link commissioning Multiple VAV compact controllers can be connected simultaneously to the power supply or individually. For Plug&Play commissioning, the PL-Link capable controller must be preconfigured as per the recommended engineering and commissioning workflow described in Technical Basics P3547. The PL-Link controller is online. The VAV compact controllers are not connected to the power supply. Simultaneously connect all VAV compact controllers to the power supply (or individually as applicable) PL-Link controller and VAV compact controllers execute registration and address assignment. Configuration is uploaded from the controller to the VAV compact controllers. Optional: Press middle key for connection test (>2 sec and <20 sec). KNX LTE-mode commissioning VAV compact controllers, KNX LTE-mode controller and operating units are connected to the power supply; ACS790 is started. In ACS790, open Applications / Device list a) Set a VAV compact controller to addressing mode (Push button on device LED shines red) b) In ACS790, click button Programming mode Address assignment enter physical address click Write or a) Select a VAV compact controller from the device list by ID (IDs are collected during mounting), b) Double click the selected row to open the dialog box Address assignment, Enter a physical address and short description for the selected VAV compact controller, Click Write to close dialog box, Repeat steps for all VAV compact controllers for commissioning. Continue: Further configuration with ACS790. KNX S-mode commissioning For KNX S-mode, the general S-mode commissioning procedures apply for ETS3 or ETS4. The HMI (push button and LED) conforms to the KNX standard. Ordering through the VAV box manufacturer (OEM) As a rule, documentation provided by VAV box manufacturers (OEM) contains detailed information on VAV compact controller ordering information. The OEM generally configures and assembles VAV compact controllers as VAV box units. This facilitates commissioning at the construction site considerably. Use service kit AST21 (PC software for service ACS941 and interface converter AST in a transport case) should changes nevertheless be required on site. OEM always sets V n (nominal air volume flow) as a matter of principle. 6 / 10

Disposal The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Technical Data Power supply AC 24 V Operating voltage / frequency AC 24 V ±20 % / 50/60 Hz (SELV/PELV) G (core 1, red) and Power consumption at G0 (core 2, black) Actuator holds 1 VA/0.5 W Actuator rotates 3 VA/2.5 W Damper actuator Nominal torque 5 Nm (GDB) / 10 Nm (GLB) Maximum torque Nominal rotation angle / maximum rotation angle 90 / 95 2 Running time for nominal rotation angle 90 Direction of rotation (adjustable with ACS941) <7 Nm (GDB) / <14 Nm (GLB) 150 s (50 Hz) / 125 s (60 Hz) Clockwise / counter clockwise KNX-Bus Connection type KNX, TP1-256 (el. insulated) Configuration and Bus load Bus topology 5 ma Refer to Technical Basics P3547 maintenance interface Terminal strip 7-pin, grid 2.00 mm Connection cable Cable length 0.9 m Number of cores and cross-sectional area 2 x 0,75 mm 2 Degree of protection and safety class Degree of protection acc. to EN 60529 (Refer to mounting instruction) Safety class acc. to EN 60730 Environmental conditions Operation / transport IEC 721-3-3 / IEC 721-3-2 Standards and Regulations IP54 Temperature 0...50 C / 25 70 C Humidity (non-condensing) Product safety III <95% r.h. / <95% r.h. Automatic electric controls for household and similar use EN 60730-2-14 (mode of action type 1) Electromagnetic compatibility (Application) EU Conformity (CE) RCM Conformity For residential, commercial and industrial environments GDB181.1E/KN GLB181.1E/KN A5W00003842 1) A5W00000176 1) GDB181.1E/KN GLB181.1E/KN A5W00003843 1) A5W00000177 1) Product environmental declaration 2) CM2E4634E 1) Dimensions W x H x D 71 x 158 x 61 mm Suitable drive shafts Type of drive shaft Round Round, with centering element Square Min. drive shaft length Max. shaft hardness 8...16 mm 8...10 mm 6...12.8 mm 30 mm <300 HV Weight Without packaging 0.6 kg Air volume controller 3-position controller with hysteresis V max, adjustable (resolution 1 % / factory setting 100 %) 20 120 % V min, adjustable (resolution 1 % / factory setting 0 %) -20 100 % V n, adjustable (resolution 0.01 / factory setting 1.00) 1 3,16 V n = 1 300 Pa at nominal air volume flow 7 / 10

V n = 3,16 30 Pa at nominal air volume flow Differential pressure sensor Connection tubes (Interior diameter) 3 8 mm Measuring range Operating range Precision at 23 C, 966 mbar and optional mounting position Zero point Amplitude Drift Max. permissible operating pressure Max. permissible overload on one side 0 500 Pa 0 300 Pa ± 0.2 Pa ± 4.5 % of the measured value ± 0.1 Pa / Year 3000 Pa 3000 Pa 1) The documents can be downloaded from http://siemens.com/bt/download 2) The product environmental declaration contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Internal diagrams The VAV compact controller is supplied with two prewired connecting and communication cables. All interconnected devices must be connected to the same G0. Internal diagram (Applies to all types) 1 1 2 (G) (CE+) (CE-) Tool = Configuration and maintenance interface (7-pin) p (G0) 2 Tool 3547G01 Power supply and bus cable (color coded and labeled) Core designation Core color Terminal code Description Cable 1: Power / black sheathing 1 red (RD) G System voltage AC 24 V 2 black (BK) G0 System neutral AC 24 V Cable 2: Bus / green sheathing 1 red (RD) CE+ Bus (KNX / PL-Link) 2 black (BK) CE- Bus (KNX / PL-Link) 8 / 10

Wiring diagram VAV Connection to the KNX TP1-Bus 3547A01 G X1 M U1 D1 GND CE+ CE- G CE+ CE- G0 Y10 Y1 Y2 N2 G0 N1 N1 G..B181.1E/KN N2 RDG400KN (Example of a VAV enabled room unit) Application examples Note Please refer to the Technical Basics P3547 for VAV compact controller and to the Technical Basics on the attached devices for application examples. Terminal layout may differ for each device. Devices with twin-terminals or internally connected terminals may be encountered as well as bus connection in junction boxes. Please refer to the technical basic documentation for product specific information. The operating voltage at terminals G and G0 must comply with the requirements under SELV or PELV. Safety transformers with twofold insulation as per EN 61558 required; they must be designed to be on 100 % of the time. Dimensions 8 20 min. 6 5 4.15 ø7 71 180 26.5 14 x 12 43 87 137 158 min. 100 Ø 3...8 41.3 61 2 3547M01 min. 200 min. 80 9.6 X X = 8-16 mm 12.8 mm 15 mm Measurements in mm 9 / 10

Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2011 Technical specifications and availability subject to change without notice. 10 / 10