Gas Line Sizing. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system.



Similar documents
SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

I Gotta Know What? A Math Tutorial For Prospective CPO Students. FR = FA times FMR or FR = FA x FMR Volume (V)gallons = Volume (V)cubic feet x 7.

Natural Gas Glossary of Terms

Glossary of Gas Terms

Your safety and the safety of others are very important.

BOSTON GAS COMPANY d/b/a NATIONAL GRID. Residential Non-Heating Rate Classification No. R-1

Beware of Exaggerated Claims and Uncertified Manufacturers Ratings Regarding Commercial Boiler Efficiency

Basic Nameplate Information

UNDERSTANDING REFRIGERANT TABLES

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Saves time. Saves money. Up to 2 size for commercial gas piping.

An Introduction to Natural Gas

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

Rusty Walker, Corporate Trainer Hill PHOENIX

Overview of Baseboard Heating

2010 Residential Water Heater Replacement Check List

NAVIEN AMERICA INC FITCH AVENUE

Fuel and Energy Conversion and Equivalence Chart

Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Cast Iron Radiator Heating Capacity Guide

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

Energy and Cost Required to Lift or Pressurize Water

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Pressure Vessels (Air Compressors) and LPG Tanks

C I T Y O F S E L M A F I R E D E P A R T M E N T

CSST Flexible Gas Pipe. System Design and Installation Manual

Frequently Asked Questions Generators

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Pump Formulas Imperial and SI Units

Pipe Sizing for Commercial and Industrial Natural Gas at Operating Pressures 75 mbar

= 800 kg/m 3 (note that old units cancel out) J 1000 g = 4184 J/kg o C

White paper on the comparative energy efficiency of zoned electric heaters Convectair, Inc. / Convectair-NMT Inc. September 2004

Appendix C: Conversions and Calculations

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

Commercial Gas Water Heaters

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Steam System Best Practices Condensate System Piping

Comparing Fuel Costs of Heating and Cooling Systems

OIL & GAS PRODUCTION AUDITING

TARIFF APPLICABLE TO GAS SERVICE MOBILE GAS SERVICE CORPORATION. Original Volume 1. Superseding:

Commercial Kitchen Fire Safety

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

(Adopted December 1, 1978)(Amended July 8, 1983)(Amended November 6, 2009) (Amended September 5, 2014)

Energy Efficiency Business Rebates Natural Gas Catalog

SIZING OF WATER PIPING SYSTEM

Pacific Pump and Power

THE PROPANE TECHNICAL POCKET GUIDE

Units of Measure and Conversion Factors for Forest Products

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Glossary of Heating, Ventilation and Air Conditioning Terms

One basic concept in math is that if we multiply a number by 1, the result is equal to the original number. For example,

A Glossary of HVAC Terms:

How To Understand Evaporator

Slide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation.

Technical Information

CH. 2 LOADS ON BUILDINGS

Method to Determine PERFORMANCE OF INDIRECT-FIRED WATER HEATERS March 2003 Edition

Grounding & Bonding Why it is done And How to Install Properly

Recreational Vehicles

Measurements 1. BIRKBECK MATHS SUPPORT In this section we will look at. Helping you practice. Online Quizzes and Videos

HVAC Calculations and Duct Sizing

DIMENSIONAL ANALYSIS #2

CHAPTER 2 HYDRAULICS OF SEWERS

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

The Abingdon Co. Jackie. Product Information, Manual and Warranty

Automatic Door Selection Guide

ASX7-4-IOM-7 J

Type 1 dryers: Domestic dryers to be used primarily in a family living environment. Residences Individual apartments or condominiums

Contents and Nomenclature

William A. Lotz, PE, Direct Fired Heaters Can. Result in Excessive Moisture and Condensation. By William A. Lotz, PE Consulting Engineer Acton, ME

Selecting Energy Efficient New Windows in Florida

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Unit Conversions. Ben Logan Feb 10, 2005

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Home Heating Fuels. Should I switch to firewood or wood pellets?

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Centrifugal Fans and Pumps are sized to meet the maximum

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

A SOLAR GUIDE - EVERYTHING YOU NEED TO KNOW

Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less

Your safety and the safety of others are very important.

A Beginner s Guide to MIG Welding

Use Your Power To Choose. A PSC Guide

4 Installation Requirements

R-Value and Thermal Conductivity of PEX and PE-RT TR-48/2014

hp calculators HP 33S Unit Conversions Metric units and Imperial units Conversion keys Practice working problems involving conversions

VAV Laboratory Room Airflow The Lowdown on Turndown

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Characteristics of Evaporators

Originators of the Flexible Water Tube design

Pipe Sizes For Water Distribution System Design

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

Transcription:

Gas Line Sizing When sizing Gas piping systems certain factors must be considered. They are: Z It shall provide sufficient gas to meet the maximum demand of the gas equipment. Piping must be sized to supply enough fuel for all appliances to operate at the same time. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system. Z Gas piping should be sized in accordance with the tables in the Standard Gas Code or by other engineering methods approved by local Authority Having Jurisdiction.

Use of Code Book Sizing Tables How to size gas piping. Z The Gas Code contains sizing tables and information that must be used to size most gas systems. Some large commercial and industrial systems fall outside the scope of this book and must be sized by other engineering practices. There are software programs available that will design and size fuel gas piping systems. Z When sizing piping you must first determine the gas pressure at point of delivery. Calling the gas supplier is the quickest way of checking gas pressure at the meter. You must know this information to use the correct sizing table in the Gas Code. The gas pressure delivered to residential buildings systems is 1/2 pounds per square inch (psi) or less. Since most gas appliances operate on 1/4 pounds pressure (psi) this is more than enough. In most cases high pressure (2 psi and up) is reserved for commercial and industrial applications. The supplier marks the meter to alert of high pressure.

Use of Code Book Sizing Tables Each table in the Gas code has a header that describes the system to which it applies. Always make sure that the information in this header matches the system you are installing. An example of a table header is shown below. All of the information listed in the Header of the Table must be used to size pipe. Table 402.3.(2) MAXIMUM CAPICITY OF PIPE IN CUBIC FEET OF GAS PER HOUR FOR GAS PRESSURES OF 0.5 PSI OR LESS AND A PRESSURE DROP OF 0.5-INCH WATER COLUMN (Based on a 0.60 Specific Gravity Gas)

Use of Code Book Sizing Tables The sizing tables are based on a number of factors. The main factor is gas pressure of the system. The tables cover pressures up to 50 pounds(psi) for schedule 40 pipe materials and up to 5 pound for semi-rigid tubing and Corrugated Stainless Steel Tubing (CSST) The table on the previous page is for gas pressure of 0.5 pounds(1/2 psi). This is a common pressure for residential systems. You will notice on the table also that the words Water Column is used in the headers above the tables. One inch of water column is equal to.036 psi. When 1/2 pound pressure is delivered to the meter you have 14 inches of water column. The tables listed in the Gas Code show pressure drop of the gas pressure in water column or in pounds per square foot (psi) or a certain percentage of pressure. Pressure drop is the loss of pressure of the gas as it travels through the system. It is caused by friction on the interior surface of the pipe, fittings etc.. For instance the table header shown below has a pressure drop of 0.5 inch water column. Since one inch of water column is equal to.036 psi or less than 4% of a pound of pressure You see that this is a very small loss. You also see a Specific Gravity of.60. Specific Gravity is the weight of a volume of gas compared to the weight of the same amount of air. Natural gas is always 0.60 Specific Gravity.

Use of Code Book Sizing Tables Z When determining the total load of the systems you need to know the type appliances to be connected. Gas appliance manufacturers always attach a metal plate in a visible location on each appliance. This data plate shows the Btu input rate (the maximum gas demand). Btu is the abbreviation for British thermal unit, the quantity of heat required to raise the temperature of 1 pound of water 1 degree Fahrenheit. While the appliances are rated in Btu, the gas code tables list the size of piping in cubic feet per hour (cfh). So you ll have to convert each Btu input rating to cubic feet of gas before sizing the distribution piping. Z You can assume that each cubic foot of natural gas releases 1,000 Btu per hour. Some gas has Btu ratings that vary slightly, but 1,000 Btu per cubic foot is generally a safe assumption. Assume you re sizing pipe for a gas range with a maximum demand of 68,000 Btu per hour. Divide the value in Btu by 1,000 to find the demand in cubic feet per hour: Example - 68,000 Btu 1,000 = 68 cfh

Gas Piping Problem Z Z Now lets work through sizing a sample gas piping system. Remember the thing you must know is the pressure of the gas delivered by the supplier to the meter (This will tell you which table to use), Total of the Btuh for all the appliances connected to the system and the distance gas will travel through the pipe to the farthest appliance connected. For this problem we will use the following factors: Z Size pipe in Sections 1-7 on the piping diagram using the specifications listed in the next paragraph. Z Gas is delivered at 0.5 (1/2) pound pressure with a pressure drop of 0.5 water column. The gas delivered has a 0.60 Specific Gravity. Use the Typical Piping Plan shown on the next slide to determine the size of all natural gas piping in the system.

Z Gas Piping Problem The other factor one must know to properly size a system is the distance the gas must travel (in feet) through the pipe from the point of delivery to the most remote appliance. This is called sizing by the Longest Length Method. When the footage is determined, it will be the only distance used to size piping in that system. For instance if a furnace is the most remote appliance and the pipe length is 50 feet then you would use the table column listed under 50 feet to size all pipes. If you distance exceeds the amount of footage listed in a column you must use the next column to size your pipes. For example if you had 44 feet you would go to the next column which is 50 feet and use the values listed under that column.

Sizing 0.5 PSI Gas Piping System

Use of Code Book Sizing Tables How to size gas piping. Table 402.3.(2) MAXIMUM CAPICITY OF PIPE IN CUBIC FEET OF GAS PER HOUR FOR GAS PRESSURES OF 0.5 PSI OR LESS AND A PRESSURE DROP OF 0.5-INCH WATER COLUMN (Based on a 0.60 Specific Gravity Gas)

Sizing a 2-psi system

Sizing table 2 psi system Gas Piping Sizing Table 2 psi System

Gas Piping Sizing Table 2 psi System (Tubing size from regulator to appliance cut off)

Gas Piping Sizing Table 5 psi System

Gas Piping Sizing Table 5 psi System (Tubing size from regulator to appliance cut off)

Course Complete ****Congratulations, You have completed this course. Make sure you complete the next page. It certifies the completion of this course and one (1) hour of credit. Click Here