P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Diesel Engine Driven Generators Page 1 of 6

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

DIESEL GENERATOR SETS

Spark-ignited generator set

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

APS100 Rental Generator Set Specification

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Diesel Generating Set

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Atlas Copco Generators

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

TMS TANK MANAGEMENT SYSTEM

Annex-A TECHNICAL SPECIFICATION

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

General Dimensions and Weights - Non Loader

Industrial Generator Set Accessories

Industrial Generator Set Accessories

Technical Specification. Generating Set with Waukesha engine burning natural gas

GENERATOR SET, DIESEL ENGINE, MODEL MEP-903A

WHOLESALE DIRECT INC WEST 65TH STREET

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Power Generation. Power Control PCL System Generator Set Control

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

GENERATOR TRANSFER SWITCH

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Marine Generating Sets 3.7 to 50 kva

The kva RAnge

How To Use A Cat Diesel Engine

Oil and Coolant Circulating Heating System. Model - OCSM

C18 ACERT Fire Pump Tier bkw/ rpm

OPTIONAL FEATURES 30

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Midwest Industrial Tanks

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

Auxiliary Power Unit (APU) for Military Vehicles

Frequently Asked Questions Generators

How To Control A Power Command Powerplant

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

PEACH PACKAGED ELECTRIC AIR CONDITIONING & HEATING PATENT PENDING FIRST RESPONDER EMERGENCY EQUIPMENT

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Technical data. Danfoss DHP-A

Diesel Generator Set Model DGDK 60 Hz

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Industrial Generator Set Accessories

Diesel Generator Set Model DFHC 60 Hz

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

Utility Distribution Systems

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Industrial Generator Set Accessories

Photovoltaic Solar Energy Unit EESFB

Industrial Generator Set Accessories

Generator DoCKInG StatIonS

The Yachtmans Choice...

Commercial Electric Water Heater

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Industrial Generator Set Accessories

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Generator Parts List. GXi Part Number. Model Year. 5650,5650EL, 6500, 6500EL, 4550 Pro, 7550EL Pro DEK, STANLEY

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

JCB MIDI EXCAVATOR 8040 ZTS / 8045 ZTS

A/C-HEATER SYSTEM - AUTOMATIC

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SPP Pumps Inc. Atlanta

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Industrial Generator Set Accessories

Signature and ISX CM870 Electronics

OPL BASIC. Dosing System for Professional Laundry machines. Contents

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Product Specification instalert Rapid Messenger Variable Message Sign

Mini Hydraulic Excavator

USER S MANUAL HSC-24A

Diesel Generator Set Model DFMB 60 Hz

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

SWITCHGEAR. EGP Switchgear

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Transcription:

Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0 L displacement o Tier II approved Steel, single wall fuel tank o 113 gal. capacity o 26 hr. run time full load o Fuel tank built into skid of generator set Fuel consumption at prime: o 100% - 4.0 gph (15.1 Lph) o 75% - 3.0 gph (11.4 Lph) o 50% - 2.0 gph (7.6 Lph) Cooling system capable of operating at 120 F ambient Radiator and oil drains plumbed to exterior Rubber vibration dampers isolate engine/generator from frame Disposable air filter - paper element Air cleaner restriction indicator mounted on control panel 60 Hz engine/generator Electronic isochronous governing GENERATOR Marathon Electric o Brushless o 4 pole o Class H insulation Voltage regulation +/- 1% with Marathon SE350 Voltage Regulator SYSTEM OUTPUT 3 position selector switch o Single phase 120 / 240V Zig Zag o Three phase 120 / 208V Low Wye o Three phase 277 / 480V High Wye 49 kw / 49 kva standby, single phase 45 kw / 45 kva prime, single phase 52 kw / 65 kva standby, three phase 47 kw / 59 kva prime, three phase www.m-p-llc.com Page 1 of 5

SYSTEM CONTROLS Microprocessor-based controller o Backlit, 128x64 pixel resolution display o -40 F to 185 F operating temperature range o Thermostatically controlled LCD heater o Six LED indicators w/ lamp test Alarm / Fault (Red) Ready / Manual (Red) Running (Green) Warning (Yellow) Ready / Auto (Green) Supplying Load (Green) Push buttons for easy operation o Manual or Auto Start o Engine Start or Stop o Alarm Cancel & Fault Reset o Scrolling Arrows for Diagnostic Information System kw output display Line output & frequency display Engine diagnostic display Oil pressure Engine temperature Fuel level Battery System hours Running hours kw hours Time to service o Alarm list warnings / shutdowns are date & time stamped Fuel level: warning 15%; shutdown 5% Overspeed protection: shutdown 115% Oil pressure: warning 25 psi; shutdown 20 psi Coolant temperature: warning 220 F; shutdown 230 F Battery voltage: over 15VDC; under 11VDC Generator over voltage: warning 110%; shutdown 111% Generator under voltage: warning 87%; shutdown 86% Generator over frequency: warning 105%; shutdown 110% Generator under frequency: warning 95%; shutdown 90% Over current shutdown ELECTRICAL CONTROLS Remote start / stop contacts located next to lug box Lockable control box door with diagnostics window Lockable lug box with safety switch o Trips main breaker when door is opened o Disables voltage regulator www.m-p-llc.com Page 2 of 5

Cable entry guides to the lug box o Provides separation for cables o Restricts access of foreign objects Output ground connection lug inside lug box 225A main breaker with shunt trip Convenience receptacles with individual breakers (restricted use in high wye mode) o (2) 120V 20 Amp GFCI duplex outlets (Nema 5-20R type) o (2) 125 / 250V 50 Amp, 3 pole, 4 wire twistlock (Non-Nema 6369) Panel mounted rheostat for voltage adjustment - +/- 10% 720 CCA wet cell battery ENCLOSURE TRAILER Aluminum, sound attenuated enclosure o UV & fade resistant, high temperature cured, white polyester powder paint o Insulated and baffled o 68 db(a) at 23 feet prime power Fully lockable enclosure including doors and fuel fill Stainless steel hinges on doors Emergency stop switch located on outside of enclosure Central lifting point Multi-lingual operating/safety decals Document holder with operating/parts manuals including AC/DC wiring diagrams DOT approved tail, side, brake, and directional lights o Recessed rear lights Transportation tie downs Safety chains with spring loaded safety hooks 2 ball hitch 5000 lb. axle 3000 lb. tongue jack with footplate P205/75R15 tubeless tires 6 ply WEIGHTS & DIMENSIONS Skid mounted Dry weight: 2345 lbs (1064 kg) Operating weight: 3180 lbs (1442 kg) 95 x 35 x 56 in (2.41 x 0.89 x 1.42 m) Trailer mounted Dry weight: 2860 lbs (1297 kg) Operating weight: 3700 lbs (1678 kg) 143 x 57 x 72 in (3.63 x 1.45 x 1.83 m) www.m-p-llc.com Page 3 of 5

WARRANTY Engine and generator covered under OEM warranty consult factory for details. CERTIFICATIONS CSA certified ENGINE OPTIONS MMG55 Options In-line engine block heater (Kim Hotstart) Fuel transfer pump Low coolant shutdown ELECTRICAL CONTROLS OPTIONS 720 CCA gel cell battery Battery disconnect Battery charger 2A trickle GENERATOR OPTIONS PMG Generator - critical grade power quality Super Start Generator - motor starting applications VOLTAGE OUTPUT OPTIONS 4 position phase switch Single phase 120 / 240V Zig Zag Three phase 120 / 208V Low Wye Three phase 277 / 480V High Wye Three phase 120 / 240V Delta Dedicated voltage configurations Buck Transformer kit Provides 120V at GFCI outlets when in 277/480V SYSTEM CONTROLS OPTIONS Analog gauges Auxiliary strobe/audible indication for soft & hard alarm conditions COOLANT OPTIONS 60/40 Coolant - cold weather applications ENCLOSURE OPTIONS Fire extinguisher Interior cabinet light Control panel light www.m-p-llc.com Page 4 of 5

FUEL TANK OPTIONS 36 hr. single wall fuel tank (requires tandem axle trailer) 24 hr. double wall fuel tank 120% Containment TRAILER OPTIONS Single axle trailer w/ surge brakes Single axle trailer w/ electric brakes Tandem axle trailer w/ surge brakes Tandem axle trailer w/ electric brakes 6 pin or 7 spade electrical connectors Spare tire/wheel kit HITCH OPTIONS 3 lunette ring 2 5/16 ball Adjustable height options: 2 ball 2 5/16 ball www.m-p-llc.com Page 5 of 5